Channel Modeling of Single Wire Earth Return Networks for Narrowband Power Line Communication and Sensing: A Field-Validated High-Frequency Digital Twin

Wania Anoosh, Cagil Ozansoy, Douglas Gomes, Mike Faulkner, Kristi Beqirllari

eess.SP eess.SY ·submitted 2026-08-21 04:20 UTC · v1

Abstract

Upgrading Single-Wire Earth Return (SWER) networks for smart grid capabilities requires a reliable communications technology. Narrowband Power Line Communication (NB-PLC) is a potential low cost solution. Real-world deployment is challenging due to the severe, frequency-dependent attenuation caused by complex earth-return paths and heterogeneous network infrastructure. To accurately characterize the communication channel, this paper develops a high-frequency (up to 300 kHz) digital twin of an operational SWER network. The digital twin integrates a segment-by-segment transmission line model with Vector Network Analyzer (VNA) measurements of physical grid hardware, replacing standard uniform assumptions with empirical component responses. Parametric sensitivity analysis demonstrates that distributed environmental factors, such as soil moisture and line sag, act as uniform magnitude offsets. Conversely, the conductor's magnetic permeability and local injection-transformer impedances dictate the channel's resonant spectral shape. Furthermore, cross-brand analysis proves that utilizing generic transformer models introduces significant prediction errors, confirming that accurate simulation requires manufacturer- and tap-specific data. Validated against in-situ field measurements from three transmitters, this digital twin replicates the path loss and dominant frequency-selective fading of the physical grid. Yielding a Root Mean Square Error (RMSE) between 4.65 dB and 9.73 dB across the three transmit paths, the model provides a practically reliable framework for deploying NB-PLC across rural SWER infrastructure.

Comment
14 pages, 16 figures, 4 tables

Closest papers

Nearest neighbours by meaning across the whole index.

Limitations of RMS-based Stability Assessment of Converter-based Grids: A Case Study

eess.SY ·2026-08-19 ·Pol Jane-Soneira, Ognjen Stanojev, Francisco Canales Perez, Qian Long, Mario Schweizer +1 more
similarity 0.55
Abstract

The increasing penetration of power electronic converters in industrial grids introduces stability challenges at frequencies well above the electromechanical range of traditional power systems. Commercial software tools typically perform eigenvalue-based stability analysis using root-mean-square (RMS) models that assume a quasi-stationary network, thereby neglecting electromagnetic dynamics of assets --- which is standard practice in power system analysis. This paper presents a case study of an industrial grid where the conventional RMS-based eigenvalue analysis predicts stable operation, while a detailed electromagnetic transient (EMT) simulation reveals growing oscillations, indicating instability. To bridge this gap, we introduce an alternative modeling approach that formulates the network dynamics in the rotating $dq$ reference frame, retaining the differential equations of electromagnetic dynamics. The resulting model enables eigenvalue analysis that correctly identifies the unstable modes, consistent with the EMT simulation results. Our findings highlight a fundamental limitation of RMS-based stability assessment for converter-dominated grids and demonstrate that dynamic impedance models in the dq frame provide a viable path toward accurate small-signal analysis encompassing high-frequency converter-network interactions.

0.32

GridForge: A Tractable Network-Flow Method for Constructing Open, Continental-Scale Synthetic Power Grids

eess.SY ·2026-11-12 ·Jonathan M. Snodgrass, Thomas J. Overbye, Christopher L. DeMarco, Bernard C. Lesieutre
similarity 0.52
Abstract · 30 pages, 10 figures, 7 tables; supplementary material as an ancillary file. Submitted to the International Journal of Electrical Power & En…

The goal of this paper is to construct open, continental-scale synthetic transmission grids with an optimization method that stays tractable. Security restrictions keep models of the real grid out of open research and machine-learning datasets, and optimization-based construction is hard at scale: the number of candidate lines grows combinatorially, so electrically faithful methods prune the candidates in advance. This paper presents GridForge, which keeps every bus pair within physical length limits as a candidate, selects lines with Garver's length-weighted network-flow linear program instead of binary decisions, and resizes them with a sequential direct-current (DC) power flow. Two stages of 13 regional networks are evaluated. Their node-degree distributions are nearly as strongly log-linear as those of the real Eastern and Western Interconnections ($R^2$ of 0.92 to 0.98 against 0.971 and 0.981), although the areas under the fitted lines differ from the real ones by 39.9% on average. On the upper Midwest and Tennessee Valley footprints, resizing lowers the DC power-flow loss from 5.89% to 4.14% and from 14.55% to 7.05%, and the DC optimal power-flow loss from 4.03% to 2.02% and from 5.54% to 2.47%. Without relaxing any line limit, the DC optimal power flow is feasible in 78.81% and 0.82% of the scenarios. Most lines are built at 69 kV. The models span 250 to 78,484 buses, were built on single machines, and are freely redistributable.

0.62

Time Distribution Principle Using Measured Traveling Waves in Power Grid

eess.SY ·2026-08-13 ·Haozong Wang, Yayu Yang, Jiahui Yang, Muhamman Umar Afzaal, Yuru Wu +3 more
similarity 0.51
Abstract · 6 pages, 4 figures, 4 tables

Accurate time synchronization is essential for distributed systems. Conventional methods, such as satellite-based synchronization and communication-based approaches, face challenges including signal vulnerability and dependence on communication delay symmetry. This paper proposes a novel time synchronization principle based on traveling wave (TW) measurements in power grids. By leveraging the inherent symmetry of forward and backward TW propagation, the proposed method achieves high-precision time distribution without relying on external time references. The methodology is validated through electromagnetic transient simulations on a modified IEEE 14-bus system. The results demonstrate that under normal conditions, the proposed approach achieves microsecond-level synchronization accuracy. These findings suggest that the TW-based time synchronization principle is a potential alternative to traditional methods, offering improved security and reduced dependence on communication quality.

0.07

Co-Optimization of Network Topology and Variable Impedance Devices under Dynamic Line Ratings Using Iterative McCormick Relaxation

eess.SY ·2026-10-27 ·Junseon Park, Hyeongon Park, Rahul K. gupta
benchmark similarity 0.50
Abstract

Grid Enhancing Technologies (GETs), such as Network Topology Optimization (NTO), Dynamic Line Rating (DLR), and Variable Impedance Devices (VIDs) are increasingly deployed in power transmission grids to address congestion and improve grid utilization. However, their growing adoption necessitates coordinated operation to fully exploit their benefits. This paper presents a unified co-optimization framework that integrates NTO, DLR, and VID to alleviate congestion and minimize operational costs. NTO is modeled using a node-breaker formulation to provide enhanced switching granularity, while DLR incorporates weather-dependent parameters, including wind speed and ambient temperature, to dynamically adjust transmission limits. The resulting formulation is a mixed-integer nonlinear program due to power flow constraints with bilinear VID terms, and discrete topology decisions. To improve tractability, we propose using a McCormick relaxation approach to linearize bilinear terms. Furthermore, we propose an iterative refinement of the McCormick relaxation scheme to enhance solution accuracy. The proposed framework is validated through detailed analyses on the IEEE 118-bus system, along with additional case studies on other benchmark systems to assess scalability. Results demonstrate that the proposed approach improves solution accuracy compared to standard McCormick relaxation, achieves solution quality close to the nonlinear formulation, and maintains computational efficiency.

0.29

Generalized and Unified Power Flow Framework for Converter-Dominated AC/DC Power Grids

eess.SY ·2026-10-18 ·Hamin Chang, Fei Teng, Gyu-Sub Lee, Jae-Won Chang
code/data similarity 0.50
Abstract · Submitted to IEEE Transactions on Power Systems. 10 pages + 10-page appendix (Appendices A-C included at the end). Code: https://github.com/…

Modern power grids increasingly rely on power electronic interfaces, requiring steady-state power flow analysis to accommodate diverse operating modes and network structures. Conventional approaches often rely on system-specific formulations and sequential approaches to handle such complexity. However, these approaches may limit applicability to diverse grid configurations and lead to convergence and computational issues. To address these limitations, this paper proposes a generalized and unified Newton-Raphson (NR) power flow framework for AC/DC hybrid grids. For generalized operational modeling, conventional and droop operating modes of generators and interlinking converters are represented through a common set of coefficients. For generalized structural modeling, models of AC transformers and DC/DC converters accommodate different transformer winding configurations and converter operating modes. For a unified solution, augmented variables are introduced to incorporate droop deadbands, output limits, and converter station losses into a single NR formulation, eliminating the need for sequential outer loops. To validate the effectiveness of the proposed framework, its results are compared with those obtained from existing power flow methods and electromagnetic transient simulations across transmission networks, distribution networks, and microgrids. The implementation is made publicly available to facilitate its use in analyzing AC/DC hybrid grids.

0.36

Digital Twin Enabled Talkative Power Conversion

eess.SY ·2026-11-16 ·Peter A. Hoeher, Yang Leng, Maximilian Mewis-Noll, Rongwu Zhu
unusual similarity 0.49
Abstract

Talkative Power Conversion (TPC) is a paradigm in which communication is integrated directly into switched-mode power electronic converters (PECs) by modulating their inherent switching ripple. TPC enables simultaneous power transfer and information exchange without dedicated transmitter-side communication hardware, and avoids additional wiring. This paper combines, for the first time, the Digital Twin (DT) concept with the TPC paradigm. By establishing interaction between one or several physical power converters and their virtual counterpart(s), the DT framework enables enhanced modeling, prediction, and optimization of individual or networked PECs. We distinguish three coupling architectures--embedded DT, remote DT, and networked DT--and demonstrate the added value of combining DT and TPC concepts when the DT and PEC are not co-located. The proposed framework is based on state-space modeling in conjunction with Kalman filtering and facilitates joint treatment of data transmission, parameter estimation, and system operation, thereby improving robustness, adaptability, and power efficiency. The presented approach highlights the potential of DT-enhanced TPC as a key enabler for future cyber-physical energy systems with tightly integrated power and communication functionalities.

0.28

Comparison of Open-Source PSCAD EMT Models for Large-Scale AI Data Centers in Smart Grids

eess.SY ·2026-11-17 ·Alex Chen, Ahmad Mohammad Saber, Deepa Kundur
similarity 0.49
Abstract · 5 pages, 2 figures, submitted to PESGM 2027

The rapid deployment of artificial intelligence data centers (AIDCs) introduces gigawatt-scale, highly nonlinear, and fast-varying electronic loads that challenge grid voltage regulation, frequency stability, and disturbance ride-through. Capturing their transient behavior during grid faults and rapid computational workload swings requires high-fidelity electromagnetic transient (EMT) simulations rather than root mean square models. However, limited methodologies exist to audit the component-level adequacy of EMT AIDC models. This paper proposes a software-agnostic, 41-point fidelity framework spanning 11 categories that synthesizes 37 criteria from an existing modeling guideline with four novel requirements: frequency ride-through compliance, disaggregated fan and chiller cooling loads, temperature-dependent thermal response, and DC information technology (IT) load representations. Applying this framework to the four publicly available AIDC models in PSCAD/EMTDC reveals varying degrees of completeness: while the models capture IT load transitions, uninterruptible power supplies, and transfer switches for bulk stability studies, critical gaps remain in electro-thermal cooling coupling, internal protective relaying, and site-level controls. Addressing these gaps will enable comprehensive protection coordination and ride-through compliance studies.

0.22

Electrical Power Grid Reliability Assessment Exposed to Straight Line Winds

eess.SY ·2026-10-14 ·Satish Adhikari, Md Abul Hasnat
published similarity 0.48
Abstract · Accepted at the 2026 North American Power Symposium (NAPS)

Maintaining the resilience and reliability of electrical power grids under weather driven disturbances is a critical challenge for modern power system planning and operation. Among weather driven hazards, tornadoes and hurricanes are mostly considered for research purpose overlooking straight line winds despite its significant contribution to transmission line outages and cascading effects. Accurate modeling of these events is essential for operational decision making, and long term infrastructure planning and investment. This research explores the probabilistic risk assessment of transmission lines under straight line winds and their impacts on system level performance. The approach examines the probability of transmission towers failure, transmission lines outages, cascading effects, and identify critical transmission lines. The IEEE 118 bus system was utilized to validate the proposed approach and to demonstrate how wind induced component failures propagate throughout the network, affecting power grid reliability.

0.30