CS Paper Radar

Digital Twin Enabled Talkative Power Conversion

Peter A. Hoeher, Yang Leng, Maximilian Mewis-Noll, Rongwu Zhu

eess.SY ·submitted 2026-11-16 14:58 UTC · v1
unusual

Abstract

Talkative Power Conversion (TPC) is a paradigm in which communication is integrated directly into switched-mode power electronic converters (PECs) by modulating their inherent switching ripple. TPC enables simultaneous power transfer and information exchange without dedicated transmitter-side communication hardware, and avoids additional wiring. This paper combines, for the first time, the Digital Twin (DT) concept with the TPC paradigm. By establishing interaction between one or several physical power converters and their virtual counterpart(s), the DT framework enables enhanced modeling, prediction, and optimization of individual or networked PECs. We distinguish three coupling architectures--embedded DT, remote DT, and networked DT--and demonstrate the added value of combining DT and TPC concepts when the DT and PEC are not co-located. The proposed framework is based on state-space modeling in conjunction with Kalman filtering and facilitates joint treatment of data transmission, parameter estimation, and system operation, thereby improving robustness, adaptability, and power efficiency. The presented approach highlights the potential of DT-enhanced TPC as a key enabler for future cyber-physical energy systems with tightly integrated power and communication functionalities.

Closest papers

Nearest neighbours by meaning across the whole index.

Tutorial on Closed-Loop and Application-Aware Digital Twins for Future Wireless Networks

cs.NI ·2026-10-10 ·Yuchen Liu, Sara Garcia Sanchez, Mingzhe Chen, Xingqin Lin, Berk Canberk +1 more
surveyhot direction similarity 0.53
Abstract

To support emerging applications such as extended reality, autonomous systems, and large-scale cyber-physical infrastructures, next-generation wireless networks must evolve beyond traditional communication paradigms toward tightly integrated and closed-loop systems. Digital Twin Networks (DTNs) have recently emerged as a key enabler of this transformation by bridging the physical and digital worlds through real-time, bidirectional interactions and adaptive control mechanisms. In this tutorial, we provide a comprehensive overview of DTN design and optimization across multiple system dimensions. Specifically, we first introduce the fundamental design principles of DTN creation, including high-fidelity twin modeling, telemetry integration, and cyber-physical synchronization. We then present resource optimization and semantic-driven DTNs, where application-aware objectives and semantic abstractions guide efficient data processing, communication, and decision-making. Subsequently, we explore physical-layer optimization techniques for DTNs, emphasizing joint sensing, communication, and adaptive wireless resource control. Furthermore, we examine DTN-guided network management and feedback optimization, focusing on closed-loop learning, real-time control, and reinforcement-driven adaptation between digital twins and physical networks. Finally, we review ongoing standardization efforts and enabling tools that support the practical deployment of DTNs in real-world systems. This tutorial aims to provide a unified perspective on DTNs as an emerging paradigm for application-aware, AI-native, and closed-loop wireless systems, and to highlight key challenges and future research directions in this rapidly evolving field.

0.24

The PUR-1 Cyber-Physical Digital Twin

cs.CE cs.LG ·2026-08-31 ·Vasileios Theos, Jonah Lau, Konstantinos Gkouliaras, Zachery Dahm, Konstantinos Vasili +5 more
similarity 0.53
Abstract

Digital twin technologies have the potential to improve operational flexibility and responsiveness capabilities of nuclear systems. To provide decision support, cyber event characterization, state estimation, predictive control, and real-time dynamic processing of operational data, however, an efficient digital twin needs to integrate multiple models (data-driven as well as physics-based) with explainability while at the same time maintain two-way synchronization with the physical facility at a time constant less than its operational cycle. In this work, we present the Purdue University Reactor One Digital Twin (PUR-1 DT), a cyber-physical digital twin with a complete high-fidelity physics-based and AI-driven virtual model stack (neutronics, thermal-hydraulics, point kinetics) which provides closed-loop explainable diagnostics, forecasting, predictive control, and action recommendation back to the reactor via two-way communications and a cyber-physical testbed. We demonstrate real-time synchronized state estimation and short-term forecasting over a full reactor operational cycle and conduct a series of benchmarking experiments to validate accuracy and latency. Our results show good agreement with experimental results and lay the groundwork for further development and experimental demonstration of DT-enabled functionalities in real-world facilities.

0.49

A Control Philosophy for Multiplexed Power Converters in Active Distribution Systems

eess.SY ·2026-09-06 ·Matthew Deakin, Mahmood Jamali, Nail Tosun, Shafiq Odhano
published similarity 0.52
Abstract · Accepted for presentation at ECCE 2026, Vancouver, Canada

Reconfigurable, multiplexed power electronic devices (M-PEDs) can provide more effective, flexible operation for applications in active distribution networks, enabling the mitigation of thermal constraints and voltage violations. To-date, operational approaches of these M-PEDs have not been described, a significant issue as a result of their relative complexity as compared to conventional PEDs. This work proposes a state machine-based control philosophy that can be used to manage the mutually exclusive selector- and current-control signals for M-PEDs. Two control approaches are described using this philosophy: an Off-Load approach, suitable for systems without time-critical network constraints; and a Hot-Swap approach, implemented when the impact of transients must be minimized. Simulations illustrate the evolution of the state machine for a back-to-back voltage source converter topology. It is concluded that the proposed state machine-based control philosophy enables M-PED operation whilst managing the additional complexity of this promising converter topology.

0.33

Digital Twin for Pre-Deployment Validation of AI-Driven Safety-Critical Industrial Edge Control Loops

cs.NI cs.RO ·2026-10-08 ·Sara Cavallero, Federico Tonini, Tony Chahoud, Giampaolo Cuozzo, Davide Borsatti +3 more
similarity 0.50
Abstract · submitted to journal publication

Industrial environments are increasingly characterized by the tight interaction among physical processes, communication infrastructures, and intelligent applications. In this context, Digital Twins (DTs) have emerged as a key technology for system analysis and optimization. However, existing DT solutions typically focus either on industrial processes or communication networks, while lacking an integrated and application-aware perspective. To fill this gap, this paper proposes a modular DT framework for industrial environments that jointly models physical processes, wireless communications, and application logic within a unified architecture. The feasibility of the proposed framework is experimentally validated through a real-world Proof-of-Concept (PoC) implemented in the BI-REX pilot line, involving a 5G-connected Autonomous Mobile Robot (AMR) transporting hazardous liquids and remotely controlled by an AI-driven application. The proposed DT is used to reproduce the behaviour of the real deployment and to investigate the impact of different placements of the AI application, including on-premise, edge, and remote cloud execution scenarios. Experimental results demonstrate a close agreement between DT predictions and PoC measurements in terms of both network-level metrics, such as Reference Signal Received Power (RSRP) and latency, and end- to-end application metrics, including application-level Round- Trip-Time (RTT). Moreover, the analysis shows how inaccuracies of network modeling can critically affect the feasibility of latency-sensitive industrial control loops, highlighting the potential of integrated DTs as tools for the pre-deployment design and validation of next-generation industrial systems.

0.32

Dynamic Modeling of Transmission Networks, Grid-Following Inverters, and UPS-Based AI Data Centers

eess.SY ·2026-11-02 ·Muhammad Hamza Ali, Amritanshu Pandey
similarity 0.49
Abstract

This document presents dynamic models of a transmission network and average models of power-electronic devices and loads in the synchronous $dq$ frame. We model the network in the positive sequence and its synchronous generators with the classical swing equation and a first-order turbine governor. The power-electronic models cover grid-following inverters and AI data centers. Each inverter has a phase-locked loop, a power controller, and a current controller. Each data center connects to the grid through two step-down transformers. Its low-voltage bus feeds an IT load, an induction-motor cooling load, and a constant-impedance load. A double-conversion uninterruptible power supply (UPS) serves the IT load. We model its rectifier, grid-forming output inverter, battery, and bidirectional DC-DC converter. A measured GPU power trace drives the IT demand. We replace every non-smooth operation with a smooth surrogate. This keeps the discretized model continuously differentiable for the nonlinear solver. We also show how we initialize each model at its power-flow operating point.

0.25

Data-Driven Generator Transient Prediction for Digital Twin Decision Support

eess.SY eess.SP ·2026-09-04 ·Emad Sadeghi, Emerson Miller, Kerry Sado, Adel Nasiri
similarity 0.49
Abstract · In submission for possible publication in IEEE Transactions on Power Systems

This paper develops a calibrated transient forecasting surrogate model for generator digital twin (DT) decision support that evaluates planned active- and reactive power load commands before they are applied. The proposed event-conditioned Hankel Dynamic Mode Decomposition with Control (Hankel-DMDc) model combines delay-coordinate lifting, command-event memory features, and an event-weighted Hankel basis so that sparse load-transition dynamics influence the reduced representation and fitted dynamics. This design targets intervals where voltage/frequency deviations and recovery behavior determine whether a candidate load command keeps the system within acceptable limits. To provide operator-facing confidence information, a split-conformal calibration layer is applied to the frozen surrogate model to form event-conditioned joint prediction bands for voltage and frequency. The experimental results show event-window root-mean-square errors of 1.058 V and 0.155 Hz. For a nominal 90% target, the bands attain 90.17% pointwise joint voltage-frequency coverage, with mean band widths of 3.55 V and 0.566 Hz. A 50-s open-loop rollout is computed in 181 ms on a single CPU core, approximately 280 times faster than real time, with forecast accuracy evaluated over horizons up to 5 s. These results demonstrate a computationally efficient advisory framework for generator DTs that combines transient prediction with calibrated uncertainty.

0.25

Channel Modeling of Single Wire Earth Return Networks for Narrowband Power Line Communication and Sensing: A Field-Validated High-Frequency Digital Twin

eess.SP eess.SY ·2026-08-21 ·Wania Anoosh, Cagil Ozansoy, Douglas Gomes, Mike Faulkner, Kristi Beqirllari
similarity 0.49
Abstract · 14 pages, 16 figures, 4 tables

Upgrading Single-Wire Earth Return (SWER) networks for smart grid capabilities requires a reliable communications technology. Narrowband Power Line Communication (NB-PLC) is a potential low cost solution. Real-world deployment is challenging due to the severe, frequency-dependent attenuation caused by complex earth-return paths and heterogeneous network infrastructure. To accurately characterize the communication channel, this paper develops a high-frequency (up to 300 kHz) digital twin of an operational SWER network. The digital twin integrates a segment-by-segment transmission line model with Vector Network Analyzer (VNA) measurements of physical grid hardware, replacing standard uniform assumptions with empirical component responses. Parametric sensitivity analysis demonstrates that distributed environmental factors, such as soil moisture and line sag, act as uniform magnitude offsets. Conversely, the conductor's magnetic permeability and local injection-transformer impedances dictate the channel's resonant spectral shape. Furthermore, cross-brand analysis proves that utilizing generic transformer models introduces significant prediction errors, confirming that accurate simulation requires manufacturer- and tap-specific data. Validated against in-situ field measurements from three transmitters, this digital twin replicates the path loss and dominant frequency-selective fading of the physical grid. Yielding a Root Mean Square Error (RMSE) between 4.65 dB and 9.73 dB across the three transmit paths, the model provides a practically reliable framework for deploying NB-PLC across rural SWER infrastructure.

0.33

Hybrid STAR-RIS Architecture for Joint Localization, Communication, and Power Transfer

eess.SP ·2026-08-12 ·Haoran Ni, Mohammadali Mohammadi, Xidong Mu, Hien Quoc Ngo, Michail Matthaiou
top venue similarity 0.49
Abstract · Accepted for publication in IEEE Transactions on Wireless Communications, Aug. 2026

We propose a hybrid simultaneously transmitting and reflecting reconfigurable intelligent surface (STAR-RIS) architecture with dynamically switched active and passive elements to support joint localization, communication, and wireless power transfer (WPT). We first pursue a parallel factor analysis with the alternating least squares (PARAFAC-ALS)-based tensor decomposition approach that decouples the base station (BS)-reconfigurable intelligent surface (RIS) and RIS-user channels, thereby enabling low-overhead channel acquisition. Based on this, we formulate a system energy efficiency (EE) maximization problem, subject to the spectral efficiency (SE) requirements of communication users, sensing signal-to-interference-plus-noise ratio constraints, and the nonlinear energy harvesting requirements of energy-harvesting users. The optimization problem is nonconvex since the transmit power allocation, STAR-RIS coefficients, and active/passive mode assignments are tightly coupled in both the objective and constraints. We address this issue by alternating between two subproblems, and solving them via fractional programming, successive convex approximation and a multi-seed greedy strategy employed as an initialization step. Numerical results demonstrate that selectively activating a small, well-chosen subset of STAR-RIS elements achieves 1.5 to 3 times EE improvements compared with fully passive/active architectures, while satisfying communication, sensing, and power-transfer requirements.

0.63