CS Paper Radar

Operation of Unshielded Kinetic-Inductance Traveling-Wave Parametric Amplifiers in Multi-Tesla Fields

Christian Boutan, Erik Lentz, Corwin Shiu, Deniz Erdag, Stephen Jones, Joseph Van Vlack, Logan Howe, Andrea Giachero, Paul Szypryt, Michael Vissers, Jason Austermann, Johannes Hubmayr, Stefan Knirck, Douglas Bennett, Joel Ullom

eess.SY hep-ex ·submitted 2026-08-26 03:22 UTC · v1
unusual

Abstract

Cryogenic parametric amplifiers are used to amplify radio-frequency signals for a range of applications in basic and applied science. Both Josephson Parametric Amplifiers and Josephson Traveling-Wave Parametric Amplifiers have been used as first-stage amplifiers enabling readout chains operating within a few quanta of the quantum limit. However, these devices are highly sensitive to magnetic fields, having critical current suppressed by the Fraunhofer effect, requiring substantial field-free zones. In a dark matter axion search experiment, axions convert to detectable microwave photons in the presence of a strong magnetic field, necessitating amplifiers that can reliably operate close to these environments. Kinetic-inductance Traveling-Wave Parametric Amplifiers (KTWPAs) may be the ideal candidate for this type of application having high critical magnetic field of the materials used throughout their construction. In this letter we demonstrate that KTWPAs can provide high gain (>20dB) over a multi-GHz bandwidth in spite of from multiple exposures to multi-Tesla fields. Further, we explore operational characteristics of these devices under harsh conditions as a function of overall field strength, device orientation within the field, applied bias current, and pump power & frequency. In so doing, we find KTWPA gain vanishes in devices oriented perpendicularly to a field of 0.02T, but gain values >10dB are achievable in fields over 1T when oriented near~parallel to the device plane, with peak gain achieved with an applied 0.25T to 0.5T field. It is our expectation that KTWPAs will expand the accessibility of quantum-limited RF measurements in the presence of Tesla-scale fields.

Comment
10 pages, 5 figures, supplementary information included as appendix

Closest papers

Nearest neighbours by meaning across the whole index.

OpenULF: A Modular Toolkit Enables Data-Driven Ultra-Low-Field MRI with both Classical and Quantum Sensors

eess.IV cs.CVphysics.med-ph ·2026-11-01 ·Hanhan Wu, Yuchen Yuan, Weiwen Jiang
publishedcode/data similarity 0.50
Abstract · 8 pages, 6 figures, 3 tables. Accepted for publication in the 44th IEEE International Conference on Computer Design (ICCD 2026). Code availa…

Ultra-low-field (ULF) Magnetic Resonance Imaging (MRI) offers a portable, low-cost alternative to conventional scanners by operating at field strengths below 10 mT. At these fields, two sensor technologies compete: quantum SQUID (Superconducting Quantum Interference Device) sensors, which provide high sensitivity but require cryogenic cooling, and classical induction coils, which are inexpensive and room-temperature but produce weaker signals. With conventional physics-based imaging, both suffer from low signal-to-noise ratios (SNR). Data-driven reconstruction has overcome similar limits in related inverse problems, but its use for ULF-MRI has been hindered by a lack of open datasets, benchmarks, and flexible simulators. To close this gap, we present OpenULF, a modular, open-source simulation toolkit that generates paired training data and supports end-to-end machine-learning (ML) reconstruction. OpenULF integrates a Bloch-equation-validated physics simulator, calibrated SQUID and coil receiver models, reconstruction ML networks, and an automated design-space exploration engine. Architecturally, a receiver abstract base class, a typed HDF5 contract that decouples physics from learning, and a resumable sweep engine make sensors, models, and datasets independently substitutable. Using OpenULF, we train 774 models across four anatomical datasets and conduct three design-space explorations. The effectiveness of ML reconstruction depends strongly on the dataset and the sensor. We identify a SQUID-to-coil crossover near 450 $μ$T and demonstrate that sensor hardware and ML model capacity can be traded off during system design. Sensor and reconstruction choices must therefore be co-designed: the best sensor is set by the dataset and field strength, not by SNR.

0.48

Highly Scalable Selectorless Cryogenic Memory Array Using Ferroelectric Josephson Field-Effect Transistors

cs.ET ·2026-09-25 ·Saheeb Ahmad, Shamiul Alam
similarity 0.49
Abstract · 8 pages, 4 Figures, 1 Table

Scalable memory systems that satisfy the temperature, speed, and energy requirements of cryogenic environments are essential for the development of large-scale quantum computers. They may also benefit high-performance computing and space applications. However, existing cryogenic memory technologies often suffer from limited scalability, low operating speed, and/or high power consumption, restricting the scalability of target applications. Ferroelectric Josephson field-effect transistors (Fe-JoFETs), which combine ferroelectric polarization with the superconducting properties of Josephson junctions, offer a promising solution. The ferroelectric layer enables nonvolatile storage capability, while the Josephson junction supports high-speed, energy-efficient operations. In this work, we leverage Fe-JoFETs to develop a highly scalable, ultra-low-power, nonvolatile cryogenic memory array that does not need additional selector devices for random access. Moreover, the superconducting component of Fe-JoFET provides a binary decision during read, eliminating the need for sensing peripheral circuitry. We first develop a physics-based Verilog-A compact model for Fe-JoFETs and use it to verify the functionality of the proposed memory array. By eliminating both selector and sensing circuitry, the proposed memory architecture offers higher scalability than existing technologies. The ultra-low-power operation of this memory also makes it compatible with strict power budgets of cryogenic applications.

0.35

A Study on THz Plasmonics in a CMOS Continuum Transistor Array

eess.SY ·2026-08-21 ·Hossein Naghavi, Shruti Chakraborty, Zainulabideen Khalifa, James Gruber, Aditya Varma Muppala +4 more
similarity 0.44
Abstract

This work addresses the limitations of CMOS at terahertz (THz) frequencies, where charge transit time and parasitic capacitances restrict the maximum operating frequency, fmax. As transistor dimensions shrink, reduced current handling capabilities further challenge CMOS, necessitating novel circuit design approaches for the THz domain. By leveraging the plasma characteristics of electron channels in CMOS transistors, this study explores a potential solution for THz signal amplification. Key mechanisms in plasma wave amplification within a continuum transistor array (CTA) formed by 28 nm fully depleted silicon-on-insulator (FD-SOI) CMOS transistors are investigated. A hydrodynamic transport model combined with Pierce's theory is presented to describe plasma wave propagation along the CTA. Simulations of gated amplifiers demonstrate the potential for THz signal amplification in advanced fabrication nodes. Finally, a proof-of-concept plasma wave amplifier operating at 700 GHz has been designed and fabricated, exhibiting amplification along the plasma wave propagation path.

0.23

Super-resolution ranging using a sub-terahertz self-injection-locked frequency-modulated radar

eess.SP ·2026-08-18 ·Hossein Naghavi, Zainulabideen Khalifa, Hamad Alotaibi, Farzad Khoeini, James Gruber +7 more
similarity 0.39
Abstract

Sub-terahertz (sub-THz) and terahertz (THz) frequency-modulated continuous-wave (FMCW) radars have opened a plethora of scientific and industrial applications, especially in the imaging field. While strong candidates for sub-THz/THz FMCW radar imagers are implemented using photonic methods, there is a desire to achieve the full integration and portability that only electronics can offer. However, integrated electronic sub-THz/THz FMCW radars have significantly lower bandwidth (< 100 GHz) than photonic-based radars, restricting the radar range resolution to the millimeter scale (> 1.5 mm). In addition, the electronic FMCW radar's broad bandwidth comes with increased transmitter phase noise, consequently degrading the radar range accuracy. Here, we present a sub-THz fully-integrated autodyne frequency-modulated (AFM) radar utilizing a self-injection locking (SIL) mechanism that fundamentally overcomes the aforementioned challenges of FMCW radars. The AFM radar supports an exceptionally wide effective bandwidth extending into the terahertz sweep range by forming an intermediate frequency comb spectrum in a quadratic receiver, unlocking the path for super-resolution ranging. Furthermore, SIL significantly reduces the transmitter's phase noise, allowing high-accuracy range measurements. We theoretically describe and experimentally demonstrate the SIL operation of the AFM radar. The proposed radar experimentally achieves sub-millimeter range resolution and a range accuracy of < 0.002%, enabling the imaging of covered printed letters with micrometer features.

0.22

Giant Resonant Reflection Gain from Injection-Induced Quenching in a Tunnel Diode

eess.SY physics.app-phphysics.ins-det ·2026-09-16 ·Darmindra Arumugam, Jack Bush, Brook Feyissa
unusual similarity 0.38
Abstract

Negative-resistance microwave oscillators can simultaneously sustain autonomous oscillations and coherently scatter electromagnetic waves, enabling active reflection beyond conventional linear amplification. Here we demonstrate giant resonant reflection gain from synchronization-induced phase localization in a self-sustained tunnel diode oscillator operating near 2.96 GHz. Weak resonant RF injection drives a transition from a broadband free running state to a phase localized narrowband reflected carrier. The resulting reflected enhancement reaches 83.1dB relative to the injected signal and is accompanied by greater than order of magnitude linewidth collapse, nonlinear injection pulling, and a synchronization bandwidth of 15.84 kHz. Time resolved spectrograms directly resolve injection locking and frequency entrainment, while noisy Stuart Landau simulations reproduce the observed spectral concentration and detuning dependent gain roll off near the Hopf instability. Artificially increasing phase diffusion with broadband bias noise suppresses the reflected enhancement, confirming synchronization-induced quenching of phase fluctuations as the origin of the giant coherent reflection gain.

0.24

Short-Range Microwave Interprobe Coupling in a Brain-Mimicking Phantom and Ex-Vivo Brain

eess.SP ·2026-10-12 ·Pouya Faeghi, Xiaoting Jia, Jeffrey S. Walling
similarity 0.38
Abstract · 8 pages, 10 figures, 3 tables

Objectives: Short-range wireless links (microwave range) between closely spaced devices in brain tissue are relevant to neural interfaces and intracranial sensing, yet the change in coupling between two such devices caused by a finite volume of brain-like tissue has rarely been measured directly. Technology or Method: This work characterizes a printed, microstrip-fed, parasitic-strip-loaded tapered-slot coupling probe in which only a partially inserted 12-mm wire enters the medium, while the printed structure remains outside. Results: Two fabricated probes showed a measured free-space -10-dB reflection band of 5.78 to 6.86 GHz and a fractional bandwidth of approximately 17.1%, consistent with full-wave simulation. In a controlled two-probe experiment, a homogeneous agar-gelatin-saline brain-mimicking phantom was introduced and removed while the probe arrangement and measurement conditions were retained. Introducing the phantom increased the measured transmission coefficient near 6.3 GHz by approximately 16 dB, and this differential was reproduced across repeated trials. More than five measurements in ex vivo goat brain followed the phantom transmission response within approximately 1.5 dB across the 5.78-6.86-GHz band. Time-domain analysis of the phantom-present link gave a system root-mean-square delay spread of approximately 210 ps. Full-wave dosimetry predicted a peak 1-g-averaged specific absorption rate of 1.05 W/kg for approximately 0.49 W accepted power. Conclusions and Clinical or Biological Impact: These results provide an experimentally validated reference for short-range probe coupling in brain-like media and support phantom-based bench evaluation of minimally invasive intracranial probes before in vivo studies.

0.23

Generation of entanglement statistics with a large-scale integrated photonic-electronic circuit

eess.SP quant-phphysics.optics ·2026-09-06 ·Volkan Gurses, Ali Hajimiri
similarity 0.37
Abstract · 12 pages, 3 figures

Continuous-variable quantum processors scale with the modes they can transform, and each transformation adds loss. We demonstrate optoelectronic quantum information processing, moving the mixing into radio-frequency electronics after homodyne detection. Squeezed vacuum falls on a large-scale integrated photonic-electronic circuit, a 32-channel coherent receiver array whose radio-frequency network mixes the analog photocurrents. A local-oscillator ramp reconstructs the two-mode covariance at the aperture, which is physical, and its partial transpose has smallest symplectic eigenvalue 0.99270, three standard deviations below the separability bound. Mode transformation becomes a circuit function whose scale follows integrated electronics. With electro-optic transducers in place of the photodiodes, the same receiver would transfer optical modes into superconducting circuits and back, toward a photonic-electronic quantum computer spanning the optical and microwave bands.

0.26

Hybrid Variational Quantum Circuits for Multivariate Regression and High-Dimensional Data Reconstruction

cs.LG stat.ML ·2026-09-15 ·Koffi Ognandon Ayena, Frédéric Holweck, Serge Iovleff, Amah S d'Almeida
publishedbenchmark similarity 0.37
Abstract

Variational quantum circuits (VQCs) are parameterized quantum circuits optimized classically. We propose a hybrid variational quantum circuit (HVQC) extending VQCs with a classical affine post-measurement layer, enabling vector-valued regression without the linear overhead of independent scalar circuits. Theoretically, we show that elementary one-and two-qubit circuits can approximate quadratic functions and products via data re-uploading and entanglement, providing the foundations of the full architecture. Experimentally, on two synthetic image reconstruction datasets and the Friedman1 benchmark (40,568 test samples), our HVQC matches Gaussian Process Regression and outperforms XGBoost and Random Forest. An ablation study confirms that both quantum and classical components are essential, and results highlight the central role of the feature map in hybrid quantum-classical models.

0.35