CS Paper Radar

Experimental and Signal Processing Techniques for Fault Diagnosis on a Small Horizontal-Axis Wind Turbine Generator

Francesco Natili, Francesco Castellani, Davide Astolfi, Matteo Becchetti

eess.SP ·submitted 2026-08-28 09:11 UTC · v1
publishedunusual

Abstract

Small HAWT is a technology characterized by non-trivial critical points, basically because it is targeted for domestic use and therefore cheap manufacturing and control must conjugate with good efficiency under possibly complex flow conditions (especially in urban environment). Therefore, dynamical control optimization and noise and vibration mitigation are pressing issues for this kind of technology. Despite it is peculiar of small HAWTs that the generator constitutes a non-negligible fraction of the total mass and therefore the electromechanical coupling is relevant, condition monitoring of small HAWT generators is an overlooked topic. The present work is a test case study of damage diagnosis on a permanent magnet generator of a HAWT having 3 kW of maximum power and 2 meters of rotor diameter. The experimental analysis is conducted through wind tunnel tests and on a generator test rig where a damaged and an undamaged generators have been driven at different rotational speeds. Vibration measurements are collected in the wind tunnel through radial accelerometers near the rear bearing of the shaft and in the test rig through uni-axial accelerometers (fixed in radial positions, in order to be aligned with front and rear bearings). The test rig data result being particularly useful for studying the low-frequency tail of the vibration spectrum, where the characteristic frequencies of the bearing are located. The experimental data are analyzed in the time and frequency domain for feature extraction: a fault in the cage of the bearing supporting the generator is diagnosed using in particular the spectral coherence analysis.

Journal ref
Vibration 2019, 2(2), 187-200
DOI
10.3390/vibration2020012

Closest papers

Nearest neighbours by meaning across the whole index.

Energy-Based Fault Detection and Isolation Framework for Flat Port-Hamiltonian Mechanical Systems

cs.RO eess.SY ·2026-10-24 ·Johnny Garcia, Nicolas Salguero, Naveed Iqbal, Brahim Brahmi, Ramy Rashad
unusual similarity 0.47
Abstract

Fault diagnosis during regulated motion requires informative signals even when feedback attenuates tracking deviations. This paper develops an energy-based diagnostic framework that constructs mechanical port-power residuals without a dedicated dynamic observer. Spectral Hamiltonian Algebraic Power Evaluation (SHAPE) combines port-Hamiltonian variables and differential flatness to generate nominal power references from planned motion for fully actuated mechanical systems with collocated actuation. Subtracting these references from commanded effort multiplied by measured flow yields residuals whose final evaluation requires neither recursive observer updates nor measured-state dynamics calculations. Continuous wavelet transform (CWT) scalograms and a shared-encoder convolutional neural network are used to distinguish nominal operation, actuator loss of effectiveness, anomalous friction, and vibration from complete trajectories. Evaluation uses a simulated six degree of freedom Kinova manipulator under model predictive control and fixed plant-model mismatch, with single faults at a specified joint. Across five training seeds and 3000 held-out test runs, SHAPE-CWT achieves a mean accuracy of 84.69 percent, versus 81.67 percent for torque residuals and 97.17 percent for the generalized momentum observer under common CWT processing. The respective sample standard deviations are 0.70, 0.70, and 0.37 percentage points. These results demonstrate useful fault-type discrimination from algebraic power residuals, while severity-excitation profiles and offline velocity perturbations reveal limits to their diagnostic capability.

0.24

A Harmonic-Regression ARMA model for rotating machinery dynamics identification and fault detection under varying conditions

eess.SP ·2026-09-23 ·Dimitrios M. Bourdalos, John S. Sakellariou, Spilios D. Fassois
published similarity 0.46
Abstract · Accepted for publication in the Proceedings of the International Conference on Noise and Vibration Engineering (ISMA 2026), Leuven, Belgium,…

Fault detection in rotating machinery under varying operating conditions remains a challenging problem. Existing approaches are mainly based either on non-parametric vibration signal representations, parametric deep learning models, or on parametric ARMA-type models. While deep learning approaches often lack transparency and require large training datasets, ARMA-type models rely on the assumption of a purely rational spectrum, which can be restrictive for rotating machinery vibration signals exhibiting mixed spectral characteristics. To address these limitations, a novel Harmonic Regression ARMA (HR-ARMA) model is presented for rotating machinery dynamics identification, which combines an explicit harmonic regression part for representing the dominant deterministic cyclical components with an ARMA part for the remaining broadband stochastic dynamics. Based on this model and within a Multiple Model framework, fault detection is achieved under varying operating conditions. The HR-ARMA modelling performance is validated through simulation and experimental studies on a single-stage gearbox, demonstrating accurate representation of both cyclical and broadband dynamics, improved parsimony and significantly higher fault detection performance compared with conventional ARMA models, achieving at least 98% True Positive Rate at 5% False Positive Rate in the experimental study.

0.39

Stagewise Anomaly Detection for E-Transaxle Quality Monitoring Using Wavelet and STFT Features

eess.SP cs.LGstat.OT ·2026-08-27 ·Mohammad N. Bisheh, Rajesh Gupta, Qian Wang, Mohammad Babakmehr, Colin Brady +3 more
similarity 0.44
Abstract

This paper presents two interpretable machine-learning frameworks for quality screening of e-transaxle assemblies in electric vehicles: a Stagewise Wavelet Isolation Forest (SWIF) framework and a short-time Fourier transform (STFT)-based diagnostic framework. High-dimensional vibration signals acquired from front and back accelerometers are analyzed across multiple operating stages to capture stage-dependent vibration behavior. In the SWIF framework, signals are decomposed using a five-level Daubechies-4 discrete wavelet transform, and blockwise mean-squared coefficients are extracted from the selected wavelet detail level to obtain compact multiscale features. In the STFT-based framework, dominant-frequency trends are extracted from time-frequency representations and summarized through regression coefficients with respect to instantaneous motor speed. Anomaly detection models are trained using accepted production units under the assumption that only a small fraction of accepted assemblies contain latent defects, and their performance is evaluated using road-tested units with validated quality outcomes. Experiments on production and road-tested e-transaxle units show that both approaches provide interpretable diagnostic information, while SWIF achieves the most favorable balance between defect detection and false-positive control. Compared with the STFT-based method and alternative anomaly detectors, SWIF combined with Isolation Forest yields lower anomaly rates within the Accept population while identifying high-risk units from the Reject population. The stagewise structure further localizes anomalous behavior to specific operating conditions, supporting root-cause analysis and targeted process improvement.

0.44

Understanding the limits of snapshot-based fault diagnosis in distribution networks

cs.AI ·2026-11-13 ·Ba Tu Phung, Huy Hoang Le, Kim-Anh Nguyen
similarity 0.42
Abstract

Inverter-based resources weaken fault currents in distribution networks, and snapshot-based diagnosis, which classifies a fault from voltage phasors at a few buses at one instant, offers a cheap first-stage screen. Its published accuracies, however, rest on different noise assumptions and do not show whether the error comes from the classifier, the features, the measurement error, or the fault resistance. This paper separates these sources on three IEEE test feeders and a public data set with distributed generation, using four feature sets, thirteen classifiers, and measurement error defined by total vector error classes. The classifier is not the limiting factor, because the full phasor snapshot classifies every fault correctly without noise, and the remaining error comes from measurement error on high-impedance faults. Three voltage sensors classify 90-96% of faults at the 1% accuracy class and 96-99% with distribution micro phasor measurement units (micro-PMUs). A discriminability-margin placement selects them from simulations alone in under one second and matches the best of twelve placement methods. The results show when snapshot-based diagnosis can be trusted.

0.25

A Time-Frequency-Condition Multimodal Fusion Foundation Model for Universal Rotating-Machinery Fault Diagnosis under Multi-Element Heterogeneous Scenarios

cs.CL cs.AI ·2026-11-11 ·Xinyu Zou, Jian Ma, Liang Ma, Chen Lu, Tao Peng +1 more
similarity 0.42
Abstract

Intelligent fault diagnosis models are typically developed for a single machine under a specific set of operating conditions, such that each new machine or condition requires retraining from scratch. This one-machine-one-model paradigm scales poorly. Although transfer learning and domain generalization can reduce the labeling burden, they primarily seek domain-invariant commonality, potentially discarding machine-specific characteristics that are critical for diagnosis. This paper proposes TFC-MMFD, a time-frequency-condition multimodal fusion foundation model for rotating-machinery fault diagnosis under multi-element heterogeneous scenarios. Statistical indicators, time-frequency images, vibration sequences, and textual machine and condition descriptions are tokenized into a unified language-like space, allowing inputs of different physical origin to be represented as a single sequence. A LLaMA backbone, together with cross-modal bidirectional attention and a Q-Former, then distills this sequence into fault-mode queries. Diagnosis is performed by matching these queries against natural-language fault-mode anchors rather than fixed class indices, while regression-adversarial condition disentanglement and condition-conditioned masked pre-training improve robustness to changing conditions. Across four progressive tasks on ten public bearing datasets spanning diverse bearing types, speeds, and loads, TFC-MMFD attains 99.40% accuracy and 99.16% macro-F1, maintains over 80% accuracy on most interpolated unseen conditions without adaptation, and improves from 20.26% to 95.63% accuracy on an unseen machine with only five labeled samples per class. It outperforms the strongest of eight domain-generalization baselines by 10.57 percentage points and compares favorably with a recent bearing foundation model while using less than half of its fine-tuning data.

0.15

A Systematic Evaluation of Machine Learning Methods for Fault Detection and Line Identification in Electrical Power Grids

cs.LG eess.SP ·2026-09-15 ·Julian Oelhaf, Georg Kordowich, Paula Andrea Pérez-Toro, Tomás Arias-Vergara, Andreas Maier +2 more
publishedhighly cited similarity 0.40
Abstract · Accepted at ICASSP 2025. 5 pages, 4 figures. Published version: DOI 10.1109/ICASSP49660.2025.10890544

The integration of renewable energy sources into the electrical grid introduces complex challenges in fault detection and coordination of grid recovery mechanisms. Traditional relay protection systems, which operate based on static rules and predefined thresholds, are inadequate for addressing these challenges, particularly in detecting and isolating faults such as short circuits. Consequently, the conventional methodologies applied to electrical network protection frequently fail to achieve optimal performance in fault detection, especially in terms of adherence to safety standards and the selective limitation of damage. Recent research indicates that machine learning (ML)-based approaches can effectively tackle these issues; however, variations in grid configurations and analysis windows have impeded consistent comparative assessments. In this study, we assess the efficacy of various ML models in detecting electrical faults and pinpointing defective transmission lines within a 10 ms measurement interval - a critical time-frame for real-time operational viability, for the first time. The most effective model attained an F1 score of 0.991 +/- 0.018 and demonstrated a processing time of 0.342ms +/- 0.509ms.

0.52

Lightweight Time-Frequency Vibration Sensing for Consumer Device Condition Monitoring

eess.SP cs.LG ·2026-10-09 ·Po-Heng Chou, Jen-Yu Chiu, Chun-Yu Yeh, Wei-Lung Mao, Walid Saad
benchmark similarity 0.40
Abstract · 6 pages, 3 figures, and 4 tables. Submitted to the 2027 IEEE International Conference on Consumer Electronics (ICCE 2027)

Consumer rotating devices, including washing machines, air conditioners, electric fans, robotic vacuum cleaners, and home fitness equipment, increasingly rely on vibration sensing for intelligent condition monitoring and predictive maintenance. Ensuring reliable operation in these resource-constrained appliances requires efficient, lightweight artificial intelligence (AI) solutions capable of processing non-stationary signals under real-world operational interference. This paper proposes a lightweight AI-assisted vibration sensing framework that employs continuous wavelet transform (CWT) and Hilbert-Huang transform (HHT) to convert one-dimensional (1-D) vibration time-series signals into two-dimensional (2-D) time-frequency representations. These representations are subsequently analyzed using lightweight deep learning architectures, specifically MobileNetV3-Small, ConvNeXt-Tiny, and the You Only Look Once version 11 classification model (YOLOv11-cls). Public bearing benchmark datasets, including Case Western Reserve University (CWRU), Paderborn University (PU), and Intelligent Maintenance Systems (IMS), are utilized as representative rotating components to investigate model generalization. The proposed framework is designed with eventual embedded deployment in consumer electronics in mind. Experimental results demonstrate that CWT combined with YOLOv11-cls achieves high diagnostic accuracy, while MobileNetV3-Small provides an attractive low-latency alternative for computationally constrained edge platforms. Conventional random splitting is also compared with dataset-specific structured isolation. The results highlight the importance of avoiding data leakage and quantify tradeoffs in classification accuracy, parameter count, floating-point operations (FLOPs), model footprint, preprocessing cost, and central processing unit (CPU) inference latency.

0.23

Improved Closed-Form Identification of the Air-Gap Permeance in Magnetic Equivalent Circuits of Rotor-Eccentric Electric Motors

eess.SY ·2026-11-13 ·Philip Desenfans
unusual similarity 0.40
Abstract · This work has been submitted to the IEEE for possible publication. Copyright may be transferred without notice, after which this version may…

Fast and accurate simulation of electric motors is essential for their design, fault diagnosis and control. Magnetic equivalent circuits (MECs) offer a computationally efficient alternative to the finite element method (FEM), yet their flux tube representation poorly captures the air-gap field. This creates a challenge, as the air gap stores most of the magnetic energy and governs the electromagnetic torque and, in rotor-eccentric motors, the unbalanced magnetic pull (UMP). Existing air-gap permeance expressions vary widely in their results for torque ripple and UMP and account for tooth-normal eccentricity only. This paper proposes the dual-term air-gap permeance (DTAP) model, a closed-form expression for the air-gap permeance between a stator and a rotor tooth that accounts for tooth-normal and tooth-tangential eccentricity, with and without rotor skew. Its parameters are identified from a FEM model of the air gap and the complete set of tooth heads, which includes the shielding by the neighbouring teeth. For three motors, DTAP reproduces the FEM air-gap permeance with a 2.8-4.8 times smaller error than the state of the art, at a comparable computational cost. Implemented in the MEC of an eccentric induction motor, it reproduces the torque ripple within 1.6% and the peak UMP within 1.3% of the reference, i.e., with 2.8 and 27 times smaller deviations than the state of the art. DTAP thereby enables MEC to predict the torque pulsations and bearing loads of eccentric motors more accurately without sacrificing computational speed.

0.26