CS Paper Radar

Parameter Estimation of Power Electronic Converters with Differentiable Physics Simulation

Pingjunjin Tan, Chunlin Lv, Jinjun Liu, Yang Li

eess.SY ·submitted 2026-08-31 14:57 UTC · v1

Abstract

This article proposes a differentiable physics simulation (DP simulation)-based parameter estimation method for the condition monitoring of power electronic converters. In the proposed method, the time-domain simulation of converter dynamics is embedded into a differentiable computational graph, directly linking device parameters to observed voltage and current trajectories. By formulating differentiable time-stepping operators, the nonlinear dynamics of the converter across different circuit topologies are simulated in a unified, differentiable manner. A dc-dc buck converter is used as a representative case study. Using sparse transient samples from existing sensing channels, the method enables noninvasive parameter estimation without additional sensing hardware. Comprehensive simulation studies are conducted to evaluate the impacts of time-stepping schemes, regularization constraints, and various uncertainty sources on estimation accuracy and robustness. Subsequently, 30 distinct hardware configurations are experimentally tested for validation. The results show that the proposed method can effectively track the relative variations of health-related parameters across the critical components. This DP simulation framework provides a novel perspective for physics-informed machine learning in power electronic applications.

Closest papers

Nearest neighbours by meaning across the whole index.

Uncertainty-Aware Parameter Estimation for Condition Monitoring of Power Converters

eess.SY ·2026-08-31 ·Tomas Monopoli, Jiahong Liu, Shuai Zhao
similarity 0.75
Abstract

Changes in circuit parameters can indicate component degradation in power converters, but measurement noise and limited parameter observability can make these changes difficult to detect reliably. This paper proposes an uncertainty-aware parameter estimation framework to distinguish genuine parameter changes from variations caused by estimation uncertainty. Using a differentiable switched converter model, the method requires only one or two samples per switching period. Model-derived residual whitening and a Bayesian posterior approximation quantify estimation uncertainty and reveal poorly identifiable parameters. Simulations demonstrate improved estimation accuracy over least-squares and physics-informed neural-network benchmarks, with uncertainty estimates consistent with repeated noise realizations. Experiments on a laboratory buck converter validate the estimated parameters against independently derived references and demonstrate the detection of a controlled output-capacitance reduction. The proposed framework provides a basis for reliable parameter-change detection in power converter condition monitoring.

0.34

Sequential Learning-Based Physics-Informed Neural Network Modeling for Parameter Estimation on a Power Converter

cs.LG eess.SY ·2026-10-14 ·Samuela Rokocakau, Panagiotis Kakosimos, Giulia Tresca, Pericle Zanchetta
similarity 0.71
Abstract · IEEE ECCE 2026

A staged physics-informed neural network (PINN) is proposed for identifying the inductance, capacitance and parasitic resistances of a DC buck converter from time-domain data. Gradients are released in the order of L to C to rL to rC, a sequence derived from sensitivity analysis. The five-stage schedule recovers L and C to within 5% and the series ESR to 10%, while a three-stage variant attains the same accuracy 11% faster. An 84 factorial sweep confirms that the trained PINN remains accurate for simultaneous 8% perturbations of all four components, achieving a waveform RMSE of 2.6 x 10-2 over 5 ms-an order-of-magnitude better than a simultaneous-training baseline.

0.13

Preliminary Exploration of Large Models Based on Self-Supervised Learning for Health Monitoring of Power Electronic Converters

eess.SY ·2026-10-13 ·Xinyuan Liao, Xiangtian Deng, Yang Liu, Zhaobing Cai, Haoran Wang +1 more
top venue similarity 0.60
Abstract · Accepted by Proceedings of the 2nd Electrical Artificial Intelligence Conference, EAIC 2025

Current artificial intelligence (AI) methods for power electronics converters make limited use of the abundant unlabeled data generated during real-world operation. This underexplored resource holds significant potential for advancing model performance. To address this gap, this paper presents PE-TSFM, a time-series foundation model tailored for power module health monitoring. The model adopts the PatchTST architecture combined with self-supervised learning and is trained on more than 143 million timestamps, where over 98\% of this training data is unlabeled and collected directly from an operating traction converter. In degradation classification tasks, PE-TSFM achieves an accuracy of 87\%, considerably surpassing five conventional time-series AI models whose performance ranges from 27\% to 45\%. These results demonstrate the model's strong few-shot learning capability and generalization across different operating conditions. This work promotes a shift from narrowly focused models in power electronics toward unified, scalable foundation models that can unlock value from large-scale unlabeled operational data.

0.31

Closed-loop domain generation enhances battery health diagnosis

eess.SY ·2026-10-09 ·Yue Wu, Ziyu Mo, Jinze Dai, Ziqing Xia, Shengyu Tao +2 more
similarity 0.57
Abstract

Reliable electrode-level degradation diagnosis is essential for accurate health estimation and non-destructive monitoring in advanced battery management. Diagnosis models developed under controlled laboratory conditions can fail when operating conditions change, while acquiring sufficient full-lifespan data in new target domains remains prohibitively time-consuming and practically unfeasible. Here, we propose a closed-loop domain generation framework to enable cross-domain battery health diagnosis under dynamic conditions. Physics-constrained domain generation is achieved through Variational Autoencoder-based latent extrapolation, which maps the source data and few-shot early-life target domain data into a shared latent space and generates cross-domain samples within physical boundaries. Bayesian optimization closes the generation-diagnosis loop by automatically calibrating the sampling, latent regularization, extrapolation, perturbation, and generation-volume hyperparameters using leakage-free development validation, thereby strictly excluding later-life target data from optimization and ensuring the quality and quantity of generated data. Numerical results demonstrate that, across four cross-domain cases, the proposed framework achieves average root mean square errors of 1.53%, 2.15%, and 2.02% for positive electrode active material loss, negative electrode active material loss, and lithium inventory loss, respectively, whereas traditional methods suffer from notably higher errors or even complete failure. This framework provides a general pathway for onboard and physics-consistent electrode-level degradation diagnosis, independent of downstream diagnosis models.

0.17

Relative Discharge Stage (RDS) Classification: A Practical Indicator of Battery Discharge Progress

cs.LG ·2026-09-23 ·Khoa Tran, Tri Le, Hung-Cuong Trinh, Hung Tran-Nam
similarity 0.56
Abstract

Accurate remaining discharge time (RDT) prediction is challenging in real-world battery applications because future load profiles are unknown and highly dynamic. To address the uncertainty of continuous RDT regression, this paper introduces Relative Discharge Stage (RDS), a battery-management indicator that represents the remaining discharge condition using five interpretable classes: Normal, Good, Moderate, Low, and Recharge Required. Unlike state of charge (SOC), which reflects the current charge level, RDS characterizes the remaining discharge process without requiring future-current information during inference. A physics-informed RDS classification framework is proposed, combining SOC estimation with lightweight temporal learning. The SOC-estimation component includes second-order ECM state and terminal-voltage prediction, hysteresis and OCV temperature correction, core-temperature estimation, and AEKF state correction, supported by OCV evaluation, online STC-ECM parameter adaptation, and pretrained neural residual-voltage correction. The measured current, terminal voltage, surface temperature, and estimated SOC are arranged into a sliding observation window and processed by a lightweight temporal convolutional network. Experiments on two public lithium-ion battery datasets demonstrate robust RDS classification, with accuracy exceeding 80% under varying load and thermal conditions.

0.04

Bayesian Bias Learning-Enabled Probabilistic Voltage Estimation with Unknown Uncertainty Modeling of DERs in Distribution Grids

eess.SY ·2026-11-20 ·Yuanshuo Zhang, Ying Zhang, Fei Ding, Jiahao Chen
similarity 0.55
Abstract

One key challenge in distribution system state es- timation is unknown input statistics from the growing inte- gration of distributed energy resources (DERs), which may largely deviate from Gaussian uncertainty. Existing model-based estimators often rely on the assumption that all inputs follow known Gaussian distributions, while data-driven methods suffer from overfitting and failure in out-of-distribution scenarios. This paper proposes a Bayesian bias learning (BBL)-enabled probabilistic voltage estimation method in distribution systems with unknown DER generation statistics. The proposed learning- enabled method consists of two stages: probabilistic uncertainty inference and computationally efficient voltage estimation. First, a physics-constrained probabilistic density inference network is developed to learn Gaussian mixture representations of DER generation from historical data. Then, the resulting probabilistic representations, treated as pseudo-measurements, are integrated into a BBL-enabled voltage estimator via a decomposition- and-parallelization mechanism. Furthermore, utilizing a linear analytical solution, the proposed BBL-enabled voltage estimator efficiently captures linearization-induced biases and attains ac- curate probabilistic estimation. By integrating learning-enabled probabilistic uncertainty modeling into the parallel estimation structure, the proposed method achieves uncertainty-aware scal- able voltage estimation. Case studies on two unbalanced IEEE distribution networks show that the proposed estimator achieves significantly higher accuracy and computational efficiency under unknown uncertainty, outperforming recent data-driven and model-based methods.

0.18

Beyond Accuracy: Physics-Informed Evaluation of ANN-based Power Flow Solvers under System Shift

eess.SY ·2026-11-10 ·Dong Liu, Jochen Stiasny, Jochen Cremer, Pedro P. Vergara
similarity 0.55
Abstract

Recent advances in artificial deep learning-based power flow (PF) solvers have primarily focused on improving estimation accuracy, while their physical feasibility and operational reliability under realistic system variations remain insufficiently evaluated. This paper proposes a physics-informed evaluation framework for deep learning-based PF solvers under topology and load distribution shifts. Beyond conventional voltage-domain errors, the framework incorporates KCL gaps, branch-flow gaps, KVL residuals, continuous feasibility scores, and strict, practical, and relaxed PF feasibility rates. Four case studies are designed to investigate topology shifts, mixed topology training, load distribution shifts, and combined topology distribution shifts. Eight ANN architectures, including graph input models, load-only baselines, and physics-informed neural networks, are evaluated under consistent settings. The results demonstrate that low estimation errors do not necessarily correspond to physically feasible or operationally reliable PF solutions, particularly under combined system shifts. The proposed framework establishes an initial foundation and analysis for the development and verification of trustworthy deep learning-based PF solvers, providing support for their reliable deployment in future AI-enabled power system analysis.

0.09

A simulation based dataset of faults and events for machine learning in power systems

eess.SY ·2026-08-20 ·Georg Kordowich, Jonathan Loebel, Julian Oelhaf, Andreas Maier, Siming Bayer +2 more
similarity 0.54
Abstract

The integration of inverter-based renewable energy sources into electric grids challenges conventional power system protection. Machine learning-based solutions can address these challenges by utilizing available data in modern smart grids. However, the lack of open datasets prevents reproducibility and fair comparisons between different approaches and their results, which hinders further progress. Therefore, this paper presents EvEMTBench, a synthetic dataset of faults and events generated using electromagnetic transient simulations. The physical plausibility of the power system simulation is ensured by validating the simulation parameters against established literature and providing comprehensive documentation of the simulation procedure. The dataset is designed for training, fine-tuning, and benchmarking machine learning models by providing synchronized point-on-wave voltage and current measurements at 9600 Hz across a diverse set of topologies and voltage levels. The inclusion of a wide range of fault and operating events allows the utilization of EvEMTBench for different tasks like incipient fault detection, fault localization, or event detection.

0.50