Uncertainty-Aware Parameter Estimation for Condition Monitoring of Power Converters

Tomas Monopoli, Jiahong Liu, Shuai Zhao

eess.SY ·submitted 2026-08-31 18:29 UTC · v2

Abstract

Changes in circuit parameters can indicate component degradation in power converters, but measurement noise and limited parameter observability can make these changes difficult to detect reliably. This paper proposes an uncertainty-aware parameter estimation framework to distinguish genuine parameter changes from variations caused by estimation uncertainty. Using a differentiable switched converter model, the method requires only one or two samples per switching period. Model-derived residual whitening and a Bayesian posterior approximation quantify estimation uncertainty and reveal poorly identifiable parameters. Simulations demonstrate improved estimation accuracy over least-squares and physics-informed neural-network benchmarks, with uncertainty estimates consistent with repeated noise realizations. Experiments on a laboratory buck converter validate the estimated parameters against independently derived references and demonstrate the detection of a controlled output-capacitance reduction. The proposed framework provides a basis for reliable parameter-change detection in power converter condition monitoring.

Closest papers

Nearest neighbours by meaning across the whole index.

Parameter Estimation of Power Electronic Converters with Differentiable Physics Simulation

eess.SY ·2026-08-31 ·Pingjunjin Tan, Chunlin Lv, Jinjun Liu, Yang Li
similarity 0.75
Abstract

This article proposes a differentiable physics simulation (DP simulation)-based parameter estimation method for the condition monitoring of power electronic converters. In the proposed method, the time-domain simulation of converter dynamics is embedded into a differentiable computational graph, directly linking device parameters to observed voltage and current trajectories. By formulating differentiable time-stepping operators, the nonlinear dynamics of the converter across different circuit topologies are simulated in a unified, differentiable manner. A dc-dc buck converter is used as a representative case study. Using sparse transient samples from existing sensing channels, the method enables noninvasive parameter estimation without additional sensing hardware. Comprehensive simulation studies are conducted to evaluate the impacts of time-stepping schemes, regularization constraints, and various uncertainty sources on estimation accuracy and robustness. Subsequently, 30 distinct hardware configurations are experimentally tested for validation. The results show that the proposed method can effectively track the relative variations of health-related parameters across the critical components. This DP simulation framework provides a novel perspective for physics-informed machine learning in power electronic applications.

0.32

Sequential Learning-Based Physics-Informed Neural Network Modeling for Parameter Estimation on a Power Converter

cs.LG eess.SY ·2026-10-14 ·Samuela Rokocakau, Panagiotis Kakosimos, Giulia Tresca, Pericle Zanchetta
similarity 0.62
Abstract · IEEE ECCE 2026

A staged physics-informed neural network (PINN) is proposed for identifying the inductance, capacitance and parasitic resistances of a DC buck converter from time-domain data. Gradients are released in the order of L to C to rL to rC, a sequence derived from sensitivity analysis. The five-stage schedule recovers L and C to within 5% and the series ESR to 10%, while a three-stage variant attains the same accuracy 11% faster. An 84 factorial sweep confirms that the trained PINN remains accurate for simultaneous 8% perturbations of all four components, achieving a waveform RMSE of 2.6 x 10-2 over 5 ms-an order-of-magnitude better than a simultaneous-training baseline.

0.13

A New Index for Quantifying Stability Adaptation Effort in Power Electronics-Dominated Power Systems Based on Frequency-Domain Impedance Identification

eess.SY ·2026-10-02 ·Luis A. Garcia-Reyes, Macarena Martin-Almenta, Edgar Nuño-Martínez, Javier Renedo, Antonio Cordón-Rodríguez +2 more
published similarity 0.54
Abstract · Paper in Proceedings of CIGRE Paris Session, C4-PS1, Paper ID 11553

The increasing use of converter based resources has made stability assessment in modern power systems more challenging, particularly because many devices are available only as black box models. Conventional eigenvalue based methods require full dynamic representations, while frequency domain impedance techniques based on the Generalized Nyquist Criterion (GNC) provide stability insight but do not quantify how much a converter must be retuned to restore stability. This paper introduces the Adaptation Effort Index (AEI), a metric that measures the sensitivity of dominant modes to parameter variations and quantifies the effort required for a converter to reconfigure itself under unstable operating conditions. The AEI combines the Nyquist Stability Margin obtained from frequency domain screening with a modal sensitivity index derived from fitted state space models synthesized from black box impedance data. The method is applied to a system comprising a grid forming and a grid following converter. Results show that, although both units can be tuned to stabilize the system, the grid following converter requires significantly less adaptation effort. The AEI therefore provides a practical and model agnostic tool for identifying which converter should be reconfigured in converter dominated grids, offering valuable guidance for system operators and manufacturers.

0.30

PowerModels-ACOPF-AI: On-the-Fly Machine Learning Approach for Solving AC Optimal Power Flow Integrating Renewable Energy Sources

eess.SY ·2026-09-16 ·Bhuban Dhamala, Jose Tabarez, Anup Pandey
benchmark similarity 0.53
Abstract

The increasing complexity of modern power systems, driven by high renewable penetration, load variability, and operational uncertainty, demands fast and reliable solutions to the AC optimal power flow problem (AC-OPF). Traditional optimization methods, though accurate, often struggle with scalability and high computational burdens, making them impractical for real-time use in large networks. This paper introduces PowerModels-ACOPF-AI, a two-stage Bayesian Neural Network (BNN) surrogate designed to predict generator set points, bus voltages, and phase angles with uncertainty. The framework integrates a performance-sensitive on-the-fly learning mechanism that identifies regions of degraded prediction accuracy and dynamically retrains with additional AC-OPF solutions generated by PowerModels.jl. This self-adaptive loop ensures robust performance, enabling the model to maintain accuracy under novel or highly variable operating conditions. Validation on benchmark test systems of different sizes, namely the 30-bus, 200-bus, and 500-bus networks, demonstrates strong generalization capability, efficient handling of stochastic renewable injections, and the ability to provide rapid, uncertainty-aware predictions. Beyond predictive accuracy, the proposed approach offers practical value as both a real-time advisory tool for system operators and a fast initializer for conventional solvers, thus supporting resilient and efficient grid operation in future power systems.

0.16

Preliminary Exploration of Large Models Based on Self-Supervised Learning for Health Monitoring of Power Electronic Converters

eess.SY ·2026-10-13 ·Xinyuan Liao, Xiangtian Deng, Yang Liu, Zhaobing Cai, Haoran Wang +1 more
top venue similarity 0.53
Abstract · Accepted by Proceedings of the 2nd Electrical Artificial Intelligence Conference, EAIC 2025

Current artificial intelligence (AI) methods for power electronics converters make limited use of the abundant unlabeled data generated during real-world operation. This underexplored resource holds significant potential for advancing model performance. To address this gap, this paper presents PE-TSFM, a time-series foundation model tailored for power module health monitoring. The model adopts the PatchTST architecture combined with self-supervised learning and is trained on more than 143 million timestamps, where over 98\% of this training data is unlabeled and collected directly from an operating traction converter. In degradation classification tasks, PE-TSFM achieves an accuracy of 87\%, considerably surpassing five conventional time-series AI models whose performance ranges from 27\% to 45\%. These results demonstrate the model's strong few-shot learning capability and generalization across different operating conditions. This work promotes a shift from narrowly focused models in power electronics toward unified, scalable foundation models that can unlock value from large-scale unlabeled operational data.

0.31

A Bayesian Adaptive Spectral Surrogate Model for Efficient Probabilistic Optimal Power Flow Evaluation

eess.SY ·2026-09-01 ·Xiaoting Wang, Xiaozhe Wang, Gregory Kish, Yunwei, Li
top venue similarity 0.52
Abstract · 18 pages, 15 figures. To appear in IEEE Transactions on Power Systems

This paper presents an adaptive stochastic spectral embedding (ASSE) method to solve the probabilistic AC optimal power flow (AC-OPF), a critical aspect of power system operation. The proposed method can efficiently and accurately estimate the probabilistic characteristics (e.g., mean, variance, median, and quantile-based metrics) of AC-OPF solutions while minimizing power losses. Based on estimated AC-OPF decisions (i.e., generator outputs), the confidence interval (CI)-based production cost index can be determined. Specially, an adaptive domain partition strategy is adopted to guide refinement domain selection and partition. The Bayesian compressive sensing-based coefficient calculation algorithm is integrated to enhance its performance. Numerical studies on modified IEEE 9-bus and IEEE 118-bus systems demonstrate that the proposed ASSE method offers accurate and fast evaluations compared to Monte Carlo simulations. Comparisons with a sparse polynomial chaos expansion, Gaussian process regression, and deep neural networks, further illustrate its efficacy in accurately assessing the responses with strongly localized behavior and non-symmetric distributions, providing practical decision-making bounds for generator outputs and operating costs under uncertainty.

0.42

When voltage sensors fail: Electrochemically constrained fault-tolerant state estimation for flat-plateau LFP batteries

eess.SY eess.SP ·2026-10-05 ·Feng Guo, Luis D. Couto, Hamid Hamed, Khiem Trad, Dong Zhang +3 more
published similarity 0.50
Abstract · Published in Energy Storage Materials, Volume 91 (2026), Article 105553. This is the authors' accepted manuscript. Please cite the Version o…

The flat voltage plateau of lithium iron phosphate (LFP)/graphite cells makes electrochemical-state errors and voltage-measurement abnormalities produce similar innovations, complicating state-of-charge (SOC) estimation. This work proposes an electrochemically constrained residual-bias compensation dual extended Kalman filter (RBC-DEKF) with uncertain-initialization commissioning. A thermal control-oriented parameter-grouped single-particle model (CPG-SPMT) provides paired-electrode dynamics and terminal-voltage prediction, while a separately configurable voltage-discrepancy state accommodates systematic residuals. When the initial SOC is uncertain, residual adaptation is suspended over a verified-healthy startup window. Buffered data support electrochemically constrained trajectory matching, followed by calibrated state replay and residual-channel reactivation. Frozen cross-cycle healthy-residual calibration supports commissioning and remains in the voltage prediction after handover. Evaluation covers 216 additive-bias and 168 multiplicative-gain profiles over 24 A123 temperature-drive-cycle trajectories. Relative to Single-EKF, the original RBC-DEKF reduces mean SOC RMSE from 7.646 to 0.170 percentage points for additive bias and from 22.646 to 0.356 percentage points for gain faults. Separately, 18 nonzero-initial-error profiles on three representative 50%-SOC-anchored segments give a full-record mean SOC RMSE of 1.747 percentage points, including startup, for the commissioned realization, versus 11.192 and 11.400 for the always-on RBC-DEKF and conventional joint EKF. Representative delayed bias, 10-s ramp, and gain tests show that the corrected SOC trajectory remains stable after fault introduction. The central contribution is electrochemically constrained temporal coordination of uncertain-state recovery and subsequent voltage-discrepancy accommodation.

0.66

Compositional Data-Driven Small-Signal Stability Assessment of Power Systems via Output Differential Passivity

eess.SY ·2026-11-16 ·Peng Yang, Xiaohui Zhang, Xi Ru, Feng Liu
similarity 0.50
Abstract · 14 pages

This paper proposes a compositional data-driven small-signal stability assessment framework for interconnected power systems based on output differential passivity (ODP). Without requiring explicit device models, local ODP matrices and scalar indices are estimated directly from measurement trajectories. When internal states are available, trajectory-based linear matrix inequalities (LMIs) are constructed from input-state measurements to estimate the local ODP matrices and scalar indices. When internal states are unavailable, an extended-state representation is constructed from input-output measurements, enabling the same assessment using only external signals. The estimated ODP matrices are combined with the network coupling matrix for compositional assessment of power system stability, while their scalar indices enable decentralized assessment. To address the computational and numerical challenges of trajectory-based LMIs, we introduce right-inverse whitening (RIW) to remove redundant behavioral coordinates and improve computational efficiency, and apply instrumental-variable (IV) preprocessing to alleviate numerical ill-conditioning and mitigate noise effects. Case studies on a modified IEEE 39-bus power system show that ambient measurements satisfy the required informativity conditions and that both formulations yield estimates close to model-based references under the tested noise levels. The reusable local ODP estimates also enable modular stability reassessment after controller updates.

0.30