CS Paper Radar

A Three-phase and Single-phase Compatible Dual-Mode EV On-Board Charger with Integrated Active Power Decoupling

Bitan Joydhar, Shimul K. Dam

eess.SY ·submitted 2026-09-01 07:21 UTC · v1
unusual

Abstract

Onboard charger (OBC) is essential part of Electric Vehicle (EV). High-performance EVs are preferring three phase charging to achieve higher power level. However, the ability to charge from a single phase supply is also required. A dualmode OBC for EVs is proposed, which is capable of operating from both three-phase supply and single-phase supply. The single phase charging comes with the requirement of bulky DC link capacitance due to double frequency current in DC link. The proposed topology eliminates this by achieving Active Power Decoupling (APD) using only one additional relay switch and a small capacitor. The proposed topology is verified under different conditions in a detailed simulation, which shows more than an order of magnitude reduction in DC link capacitance during single phase operation.

Closest papers

Nearest neighbours by meaning across the whole index.

A Modulation Strategy for Bidirectional Integrated Onboard and Wireless EV Charging

eess.SY ·2026-11-12 ·Manveer Aujla, Gavin Feher, Caniggia Viana
published similarity 0.67
Abstract · 7 pages, 9 figures. Accepted version of a paper presented at the 2026 IEEE Energy Conversion Congress and Expo (ECCE), Vancouver, Canada

Integrated electric vehicle chargers reduce cost by sharing power conversion hardware between the onboard charger (OBC) and the wireless charger (WC). A previously proposed dual active bridge (DAB)-based OBC/WC shares the rectification stage between the OBC and WC; however, the modulation required to realize its wireless operation has not yet been reported. This paper details a modulation strategy that enables the operation of the integrated OBC/WC topology. Differential-mode operation is used for the OBC, and common-mode operation is used for the WC. In OBC mode, the shared full-bridge produces differential-mode voltage for wired power transfer while ideally generating zero common-mode voltage on the wireless charging path. In WC mode, the same full-bridge produces common-mode voltage for wireless power transfer while ideally generating zero differential-mode voltage on the onboard charging path. The method preserves conventional DAB phase-shift power control and enables bidirectional power transfer in wired and wireless charging modes without additional contactors. Design considerations for the OBC transformer and WC coils are derived based on the resulting square-wave voltage amplitudes. Offline PLECS simulations demonstrate power tracking and decoupled charger operation at $\pm$7.4 kW. Hardware-in-the-loop simulations using a PLECS RT Box and an external Texas Instruments microcontroller further validate the proposed modulation method.

0.34

Control of Isolated Four-Quadrant Single-Stage Three-/Single-Phase X-Rectifier for EV On-Board Chargers

eess.SY ·2026-10-20 ·Sven Weihe, Jonas Huber
similarity 0.63
Abstract · Submitted to an IEEE journal

The single-stage isolated eXtended-functionality rectifier (X-Rectifier) electric vehicle (EV) on-board charger (OBC) employs 650V GaN monolithic bidirectional power transistors (M-BDS) in the input stage, provides sinusoidal input currents and four-quadrant operation in three-phase and split/single phase grids without power derating, operates from asymmetrical three-phase mains, provides reactive power if needed, and supports extremely asymmetric phase loading in standalone vehicle-to-load (V2L) mode. This paper presents a new improved phase-modular control method for the X-Rectifier that enables tracking of arbitrary and independent phase current references regardless of the instantaneous grid voltage (i.e., enables four-quadrant operation). The method supports grid-tied (i.e., grid-to-vehicle, G2V, or vehicle-to grid, V2G) and grid-forming (i.e., V2L) operation. Further, aiming towards a practical realization of the X-Rectifier, the paper addresses implementation aspects of the M-BDS half-bridges, like commutation logic around the grid-voltage zero crossing, fault handling, and soft-switching behaviour. Finally, a realized 5.5 kVA hardware demonstrator of the X-Rectifier is used to validate the proposed control method experimentally for all operating modes, including grid-tied three- and single-phase four-quadrant operation (G2V, V2G, and full reactive power modes). Further, robust V2L operation is verified with real-world loads, i.e., in three-phase mode with asymmetrical loading of the phases including a woodworking power tool, and in single-phase mode with a high-power vacuum cleaner with high inrush current and hence momentary overload of the X-Rectifier demonstrator.

0.21

An Optimal Power-Flow Grouping Topology for Single-Isolation-Stage Multi-Output Solid-State Transformers

eess.SY ·2026-11-06 ·Yi Hao, Krzysztof Puczko, Levy Ferreira Costa, Liangcai Shu, Dongsheng Yang
similarity 0.47
Abstract · 13 pages, 19 figures. Submitted to IEEE for possible publication

Electric-vehicle dc fast-charging stations and data centers require multiple high-power dc outputs with independently varying demands. Conventional multi-output solid-state transformers typically establish a common dc bus and use downstream dc/dc converters for port-level regulation and, where required, galvanic isolation. A single-isolation-stage solid-state transformer can eliminate this additional high-power interface stage by directly forming multiple isolated outputs from its submodule dc/dc stages. However, because one submodule is generally insufficient for an individual output port, multiple submodules must be connected in parallel, while inter-submodule balancing circuits redistribute power under unbalanced loading. The submodule grouping therefore determines the internal balancing-power paths. Sequential grouping can create long transfer paths and accumulated balancing power, increasing current stress and losses. This paper proposes an optimal power-flow grouping topology that interleaves submodules assigned to different output ports, thereby localizing power redistribution and reducing the power processed by the balancing circuits. Analytical models quantify the required balancing power and its reduction relative to sequential grouping. A coordinated submodule-bypass strategy is also developed, and the remaining output-power capability under different fault scenarios is evaluated. A six-submodule prototype validates the proposed topology. Under the same highly unbalanced operating conditions, the proposed topology reduces the maximum submodule dc-link voltage difference by 63\% and the peak balancing current by 14.5%, while improving the measured efficiency by approximately 5.6% at rated power. Stable post-fault operation is also experimentally demonstrated.

0.40

Co-Optimization of Scheduling, Control, and Incentivization of Electric Vehicles for Improving Power System Stability

eess.SY ·2026-10-10 ·Amit Kumer Podder, Tomonori Sadamoto, Aranya Chakrabortty
similarity 0.45
Abstract

We present a finite-horizon, greedy heuristic-based co-optimization and optimal control framework that jointly determines the optimized charging rates, charging times, and an optimal charging control law for electric vehicles (EVs) to improve both voltage stability and small-signal dynamic performance of a power distribution system. The proposed strategy encourages EV drivers to be flexible in choosing their charging rates and times through monetary incentivization under a fixed budget. The design is validated using the IEEE 33-bus distribution system model with ten EV charging stations (EVCSs). Results show that incentivizing drivers to settle for lower charging rates, implemented by a wait-and-save strategy, and rescheduling their charging times strategically can significantly improve the voltage stability index (VSI) of the system as well as the damping factors for the mid-frequency oscillation modes seen in the DC-link bus voltage.

0.20

DC-Link Voltage Regulation in a Single-Isolation-Stage Multioutput Solid-State Transformer for Wide-Range DC Outputs

eess.SY ·2026-11-06 ·Yi Hao, Levy Ferreira Costa, Krzysztof Puczko, Liangcai Shu, Dongsheng Yang
unusual similarity 0.44
Abstract · Submitted to IEEE Transactions on Power Electronics (TPEL) for possible publication

Single-isolation-stage solid-state transformers with balancing circuits eliminate an additional downstream dc--dc conversion stage. However, the remaining isolated converters must directly accommodate a wide output-voltage range. This paper investigates variable dc-link voltage operation of a single-isolation-stage multioutput SST to ease this requirement. Coordinated cascaded H-bridge modulation and embedded four-switch balancing circuits support intentionally unequal submodule dc-link voltages, allowing the isolated-converter input voltages to be adjusted according to the output requirements. The achievable voltage range is determined by relating the required balancing power to the BC transfer capability within the available CHB switching windows, subject to modulation and peak and rms current limits. The analysis quantifies the range extension provided by BC operation beyond modulation alone. For a single-phase-shift dual-active-bridge converter, input-voltage following within this range reduces the calculated peak current and extends the ideal zero-voltage-switching region compared with fixed input. Experiments on a six-submodule SST prototype demonstrate unequal dc-link voltage operation and inter-submodule power exchange. Experiments result on DAB demonstrate reduced current stress and improved efficiency with voltage following.

0.38

EMT Modeling and Coordinated Mode-Transition Ride-Through Control of Modern Data Centers

eess.SY ·2026-11-05 ·Junyuan Zheng, Salish Maharjan, Min Lwin, Soummya Roy, Zhaoyu Wang +3 more
similarity 0.43
Abstract

Large data centers are emerging as power-electronic loads whose response to grid voltage disturbances can affect bulk-system stability. This paper presents the composition and control characteristics of a proprietary electromagnetic transient (EMT) model of a modern data center comprising an uninterruptible power supply (UPS) with battery energy storage, induction-motor cooling loads, a computer room air handler (CRAH) driven by a variable-frequency drive (VFD), and an aggregated server load. A voltage-based state machine coordinates three aspects of the facility response: the UPS operating mode (eco, double conversion, or battery), the supply path of the CRAH, and a ramped reconnection of the grid-side UPS converter after the disturbance clears. A 100 MW facility is implemented in PSCAD/EMTDC and benchmarked against the PSSE PERC1 aggregate data center model under a symmetrical three-phase fault and low- and high-voltage ride-through (LVRT/HVRT) events. The two models agree closely in their voltage and active-power trajectories, while the EMT model also resolves the converter and motor-reacceleration transients that the phasor-domain model cannot.

0.50

EMT Assessment of SCR and X/R Effects on Current-Priority-Dependent LVRT Response of a Grid-Following BESS

eess.SY ·2026-10-30 ·Dileep Cheerla, Amirthagunaraj Yogarathnam, Divya Jain, Satish Natti
similarity 0.42
Abstract · 6 pages, 4 figures. Submitted to the 2027 IEEE Texas Power and Energy Conference (TPEC 2027)

Low-voltage ride-through (LVRT) forces a grid-following inverter to allocate finite converter current between active- and reactive-current objectives. This paper uses a PSCAD electromagnetic-transient (EMT) representation of an aggregated battery energy storage system (BESS) to quantify how short-circuit ratio (SCR) and grid impedance X/R ratio alter that tradeoff. Active-current priority and reactive-current priority are compared for five paired grid conditions under the same 150-ms balanced three-phase fault, with pre-fault active power approximately 0.84 pu, POI reactive-power exchange near 0 pu, and a 1.0-pu dq-current limit. Fundamental positive-sequence voltage and power are reconstructed from 100-$μ$s three-phase EMT outputs. Across the fixed-fault SCR sweep, the Q-priority late-fault voltage advantage increases from 0.046 pu in the strongest tested grid to 0.129 pu in the weakest; the weakest P-priority case also shows active-power reversal and a pronounced controller-frequency excursion. At fixed SCR, changing X/R produces a smaller increase from 0.092 to 0.112 pu, mainly through reduced P-priority voltage support. Because the common physical fault also deepens the passive retained-voltage condition as SCR decreases, the SCR result is interpreted as a fixed-fault grid-strength sensitivity rather than a constant-sag comparison. Grid strength is the larger sensitivity in the tested matrix, while X/R remains an additional modifier under the studied fault conditions.

0.37

Analysis and Demonstration of a Current-Stiff, Isolated Capacitive Bridge Transformer

eess.SY ·2026-11-10 ·Patrick Nowakowski, Cameron Little, Mahima Gupta, Daniel C. Ludois
similarity 0.42
Abstract · 10 pages, 17 figures

The traditional Voltage Source Inverter (VSI) based Dual Active Bridge (DAB) utilizes a transformer at its center to provide galvanic isolation and a turns ratio for step up/down functionality. However, the transformer is often the limiting factor of the DAB, especially as semiconductor switching speeds improve, given steel core losses, winding losses, etc. This paper presents a new DAB architecture based on Current Source Inverters (CSIs) coupled through, and isolated by, an AC capacitive bridge, yielding a system called a Capacitive Bridge Transformer (CBT). The CBT architecture eliminates all magnetic components in the AC portion of the isolated DAB circuit, reducing frequency scaling barriers normally present in DABs. The paper introduces the CBT from the perspective of duality and then develops the DC-DC power flow equations, the internal apparent power equations, and effective turns ratio. The analytical models are verified by steady state and detailed time domain measurements on a 2 kW experimental prototype.

0.30