CS Paper Radar

Effective Range and Optimal Frequency of Through-the-Earth Magnetic Induction Communication

Honglei Ma, Erwu Liu, Wei Ni, Jun Zhu, Zhijun Fang, Rui Wang, Xinyu Qu

eess.SY ·submitted 2026-09-02 11:53 UTC · v1
published

Abstract

Magnetic induction communication (MIC) is a promising technology for through-the-earth (TTE) communication. Previous studies on the MIC range have often overlooked the impact of eddy losses caused by underground materials. For TTE MIC, significant eddy losses complicate the analysis of the effective MIC range, which is vital for optimizing performance but has never been addressed in the literature. Accounting for the conductivity and permittivity of the underground medium, this paper derives the effective MIC range in TTE MIC, along with a closed-from expression that predicts the optimal carrier frequency to maximize this range. Finite element simulations validate the analysis, demonstrating that the optimal carrier frequency can significantly enhance the MIC range. It is also revealed that optimizing the antenna radius is effective in extending the MIC range for TTE and vehicle MIC applications.

Comment
This work has been accepted by IEEE Transactions on Vehicular Technology for publication, DOI: 10.1109/TVT.2026.3721188
DOI
10.1109/TVT.2026.3721188

Closest papers

Nearest neighbours by meaning across the whole index.

A Diffusive T-Matrix Unifying the Electric and Magnetic Polarizability Tensors in Conducting Layered Media

eess.SP physics.comp-phphysics.geo-ph ·2026-11-11 ·Fraser Williams, Dhammika Jayalath, Clinton Fookes, Ajay Pandey
unusual similarity 0.47
Abstract · 30 pages, 4 figures

Electromagnetic induction is used to detect and classify buried and submerged objects, such as unexploded ordnance in soil and on the seabed. A small object is commonly described by its magnetic polarizability tensor (MPT), which is independent of its position and of the sensor. The MPT assumes that the surrounding medium does not conduct. In seawater at extremely low frequency, or in clay at kilohertz frequencies, this assumption fails at depths comparable to the skin depth. The object then also diverts the current induced in the medium, a galvanic response that the MPT omits. We describe the object instead by its transition matrix (T-matrix), which keeps the independence from position and sensor and includes both responses. It is computed once per medium and frequency from a single finite element problem, for any shape and materials. Its inductive block reduces to the MPT when the medium conducts weakly, and its galvanic block reduces to the electric polarizability tensor in the static limit. We test the model against full finite element solutions for a conducting box, non-magnetic and permeable, in a layered sea and in clay over bedrock. Two orders beyond the dipole, it is accurate to within 1.4% over two decades of frequency and for sizes up to 0.7 of the depth, whereas the error of the MPT carried into the conducting medium reaches 91%. Blocks coupling the two responses, contained in neither tensor, contribute up to 13%.

0.28

Wireless Power Transfer in Titanium Implants

eess.SY ·2026-08-20 ·R. W. Porto, L. Murliky, F. R. de Sousa, A. S. de Almeida, H. M. de Albuquerque +1 more
unusual similarity 0.46
Abstract

This work addresses the problem of applications that require wireless power transfer to devices embedded within conductive blocks. The emergence of eddy currents tends to generate a magnetic field opposing that of the transmitter, drastically reducing the coupling coefficient and, consequently, the efficiency of the process. A case study involving a titanium implant is presented and analyzed with a load designed to ensure a constant current of 1 mA. An experimental setup is assembled and evaluated to compare differences in the measured electrical parameters when the receiver is embedded in the implant, considering several solutions that mitigate or avoid the effects of eddy currents. The results show that such a system may be technically unfeasible if careful attention is not paid to the geometry of the cavity in which the receiver is positioned.

0.27

Gradient-Field Frequency Encoding for 1D Localization of Magneto-Mechanical Resonators

eess.SP eess.SY ·2026-10-05 ·Fabian Mohn, Martin Möddel, Tobias Knopp
similarity 0.44
Abstract · 4 pages, 3 figures

Magneto-mechanical resonators (MMRs) have emerged as promising passive sensors for wireless localization and remote inductive sensing in industrial and medical environments. However, fundamental limits on achievable localization accuracy using the spatial sensitivity profiles of receive coils remain a key challenge. In this work, we demonstrate that an MMR - comprising two permanent magnets in an anti-parallel arrangement - exhibits a measurable shift in its mechanical resonance frequency in response to an externally applied magnetic field, a property we exploit for spatial encoding. We derive and experimentally validate a method that maps frequency shifts of 1D positions within a known magnetic gradient field, demonstrating accurate localization along a linear trajectory. This gradient-field frequency encoding approach constitutes a conceptually distinct alternative to conventional sensitivity encoding with receiver coil arrays, with the potential to simplify hardware requirements while improving localization accuracy.

0.27

Vertical Assessment of RF-EMF Exposure in a Building Adjacent to a Multi-Operator Shared Base Station

cs.NI ·2026-09-11 ·Ricardo Q. de F. H. Silva, Marcio E. C. Rodrigues, Fred S. R. Pinheiro, Gutembergue S. da Silva, Halysson B. Mendonça +1 more
published similarity 0.44
Abstract

This paper extends a previously published proposed approach for estimating worst-case exposure scenarios in buildings using publicly available Base Station (BS) parameters, applying it to a critical case involving a multi-operator shared site. Radiofrequency Electromagnetic Fields (RF-EMF) exposure was assessed on every floor of a 20-story building facing the site, revealing significantly higher levels near the center of the antennas' estimated vertical zone of interest, with a peak of 31.86 V/m, 23.95 times higher than the street-level peak value. However, due to uncertainties in the input parameters, measurements across all locations within the zone of interest are required to accurately identify the floor of maximum exposure. The results demonstrate the usefulness of the proposed estimation approach and highlight the need for improved methods that consider BS antenna configurations and current technical information to ensure accurate assessments of exposure to RF-EMF.

0.39

A Quad Beam Variable Height Antenna System for Reliable Underground Mine Tunnel Communications

eess.SY eess.SP ·2026-10-15 ·Sihua Shao, Charles Fent, Matthew Dodd, Atef Elsherbeni
unusual similarity 0.43
Abstract

Mine accidents can damage the wired backbone supporting underground wireless networks, forcing rescue teams to deploy temporary mesh nodes to maintain communication with the surface. Although higher carrier frequencies can support bandwidth-intensive applications such as live video, multimode propagation within mine tunnels produces severe, spatially localized fading. Movable antennas can mitigate these fades by adjusting antenna position; however, moving all antennas on a multi-link relay node simultaneously may improve one link at the expense of another. This paper introduces QuadBeam, a compact mesh node antenna system comprising four independently positionable 2.4~GHz patch antennas mounted on the side faces of a central hub, together with a 900~MHz monopole for backup voice communication. A preliminary prototype incorporates one motor-driven patch mount and three manually adjustable mounts. Bench measurements show interelement coupling below $-46$~dB between patches on adjacent faces. Measurements at five carrier frequencies from 2.40~GHz to 2.48~GHz in the Edgar Experimental Mine reveal 19~dB to 26~dB received-power variations across transmitter and receiver separations of 8.3~m to 18.3~m. Adjusting the receiver height over approximately 20~cm yields received-power improvements of up to 22~dB. Repositioning neighboring patches and removing or reinstalling the monopole produce no noticeable change in the active link. These results demonstrate the potential of independently positioned antennas to alleviate spatial fading in underground mesh communications.

0.24

Curved Monopoles and Yagi-Uda Arrays for Low-Angle HF Skywave Radiation over Lossy Ground: Analysis, Hybrid Bayesian Optimization, and Validated Full-Wave Design

eess.SP physics.app-ph ·2026-10-17 ·Masoud Salmani Arani, Reza Shahidi, Lihong Zhang
unusual similarity 0.42
Abstract

High-frequency (HF) skywave radars require high gain at take-off angles of 3 degrees-30 degrees, where vertically polarized monopoles and Yagi-Uda arrays over lossy land suffer from pseudo-Brewster cancellation. This paper shows that curving the elements of HF monopoles and Yagi-Uda arrays converts radiation from this soil-limited transverse-magnetic route into a transverse-electric route that is nearly insensitive to soil conditions. Closed-form half-space bounds quantify both routes and yield design rules; a separability result extends the soil insensitivity to arrays. A hybrid design method combines Bayesian optimization on analytical and method-of-moments models with full-wave simulations of a screened site on moist soil; current extraction differs by at most 5.1% RMS, and Fresnel post-processing agrees with independent perfect-ground results within 0.16 dB in pointwise gain for four arrays. At 15 MHz, a self-matched 2-element curved Yagi-Uda array and a Bayesian-optimized 3-element array achieve realized forward-sector gains of 6.8 and 8.3 dBi over moist soil, 6.4 and 6.3 dB above straight quarter-wave Yagi-Uda arrays optimized by the same procedure, with 92%-95% efficiency. Their gain changes by about 1 dB from a perfect ground to very dry soil, whereas that of the straight arrays falls by 9 dB. Bayesian optimization, confirmed by full-wave simulation, identified a design 0.2 dB above the sweep optimum and a gain-bandwidth Pareto front that offers up to twice the matched bandwidth. The results also show that the native far field of full-wave solvers can overestimate the low-angle gain of vertical arrays over soil by more than 4 dB.

0.23

Can An Array of Magnetometers Replace a DVL - A Cramér-Rao Bound Analysis

eess.SP ·2026-10-22 ·Ludvig Lindström, Isaac Skog, Magnus Lundberg Nordenvaad, Andreas Gällström
similarity 0.42
Abstract · Submitted to IEEE Journal of Ocean Engineering, 9 pages, 5 figures

Underwater vehicles rely on noisy dead-reckoning systems, such as Doppler velocity log (DVL)-aided inertial navigation systems, for positioning. However, DVLs rely on active acoustic measurements and are thus unsuitable for covert operations. Magnetic velocity estimation using a magnetic sensor array is a potential silent alternative. In outdoor environments, spatial variations in magnetic field magnitude are small, whereas temporal variations are large, making the achievable velocity-estimation accuracy uncertain. In this paper, Cramér-Rao lower bounds (CRLBs) are derived for magnetic velocity estimation using different sensor configurations and measurement models in one dimension, ignoring platform disturbances, to quantify the potential accuracy of magnetic sensor arrays. The analysis suggests that, when spatial variations are sufficient and temporal variations can be corrected using correction data, the resulting CRLB is comparable to that of an export-controlled DVL. If, instead, temporal variations are not corrected, the sensor noise must be reduced by around two orders of magnitude for the CRLB to reach the accuracy of an export-controlled DVL. Therefore, the results indicate that current magnetic sensor arrays may complement, rather than replace, DVLs in inertial navigation systems.

0.26

Channel Modeling of Single Wire Earth Return Networks for Narrowband Power Line Communication and Sensing: A Field-Validated High-Frequency Digital Twin

eess.SP eess.SY ·2026-08-21 ·Wania Anoosh, Cagil Ozansoy, Douglas Gomes, Mike Faulkner, Kristi Beqirllari
similarity 0.41
Abstract · 14 pages, 16 figures, 4 tables

Upgrading Single-Wire Earth Return (SWER) networks for smart grid capabilities requires a reliable communications technology. Narrowband Power Line Communication (NB-PLC) is a potential low cost solution. Real-world deployment is challenging due to the severe, frequency-dependent attenuation caused by complex earth-return paths and heterogeneous network infrastructure. To accurately characterize the communication channel, this paper develops a high-frequency (up to 300 kHz) digital twin of an operational SWER network. The digital twin integrates a segment-by-segment transmission line model with Vector Network Analyzer (VNA) measurements of physical grid hardware, replacing standard uniform assumptions with empirical component responses. Parametric sensitivity analysis demonstrates that distributed environmental factors, such as soil moisture and line sag, act as uniform magnitude offsets. Conversely, the conductor's magnetic permeability and local injection-transformer impedances dictate the channel's resonant spectral shape. Furthermore, cross-brand analysis proves that utilizing generic transformer models introduces significant prediction errors, confirming that accurate simulation requires manufacturer- and tap-specific data. Validated against in-situ field measurements from three transmitters, this digital twin replicates the path loss and dominant frequency-selective fading of the physical grid. Yielding a Root Mean Square Error (RMSE) between 4.65 dB and 9.73 dB across the three transmit paths, the model provides a practically reliable framework for deploying NB-PLC across rural SWER infrastructure.

0.33