CS Paper Radar

Gradient-Field Frequency Encoding for 1D Localization of Magneto-Mechanical Resonators

Fabian Mohn, Martin Möddel, Tobias Knopp

eess.SP eess.SY ·submitted 2026-10-05 10:05 UTC · v1

Abstract

Magneto-mechanical resonators (MMRs) have emerged as promising passive sensors for wireless localization and remote inductive sensing in industrial and medical environments. However, fundamental limits on achievable localization accuracy using the spatial sensitivity profiles of receive coils remain a key challenge. In this work, we demonstrate that an MMR - comprising two permanent magnets in an anti-parallel arrangement - exhibits a measurable shift in its mechanical resonance frequency in response to an externally applied magnetic field, a property we exploit for spatial encoding. We derive and experimentally validate a method that maps frequency shifts of 1D positions within a known magnetic gradient field, demonstrating accurate localization along a linear trajectory. This gradient-field frequency encoding approach constitutes a conceptually distinct alternative to conventional sensitivity encoding with receiver coil arrays, with the potential to simplify hardware requirements while improving localization accuracy.

Comment
4 pages, 3 figures

Closest papers

Nearest neighbours by meaning across the whole index.

Information-based Unified Design Framework for NMR Magnetic Tracking System

cs.RO eess.SY ·2026-10-13 ·Seçkin Eren Yetim, Mehmet Efe Tiryaki
similarity 0.63
Abstract · 6 pages, 6 figures, journal letter submission

Nuclear magnetic resonance (NMR) magnetic tracking offers a promising alternative to magnetic resonance imaging (MRI)-based localization for medical robotic guidance. However, scalar field measurements and field-aligned marker moments constrain position and orientation tracking, requiring careful configuration design. We present a unified information-based framework that uses local covariance analysis to evaluate receiver geometry, marker separation, and external source configuration in on/off-board NMR tracking. Numerical evaluation shows that planar-array precision depends jointly on receiver count and geometry, with triangular lattice arrays achieving the lowest best-case position uncertainty among the evaluated layouts for 9--20 receivers. Two spatially separated, field-aligned markers enable device-axis tracking, with predicted angular uncertainty below $2^\circ$ at the evaluated workspace center for suitable marker separations. We further establish point-dipole source--receiver duality, unifying the analysis of on/off-board NMR tracking. These

0.21

Data-Driven Localization of Magneto-Mechanical Resonators from Time Signals

eess.SP ·2026-10-21 ·Artyom Tsanda, Konrad Scheffler, Sarah Reiss, Jonas Faltinath, Janik Bach +4 more
similarity 0.60
Abstract

Magneto-mechanical resonators (MMRs) are a recently introduced sensor technology for tracking and sensing applications that enables effective miniaturization down to the millimeter regime. However, estimating sensor parameters such as position from raw signals remains computationally challenging, because it requires solving a nonlinear inverse problem with computationally demanding objective function evaluations. In this work, we show how a deep learning method can accelerate this process by directly learning the inverse mapping from the measured signals. We consider the localization problem as an example and show that a convolutional-transformer regressor trained on simulated data with recorded noise can generalize to experimental data. The method achieves a median Euclidean distance error of 7 mm, which is comparable to the size of the sensor and corresponds to 6% of the size of a single coil. These results suggest that deep learning is a promising approach for rapid estimation of MMR parameters.

0.22

Continuous Phase-Coherent Readout of a Magneto-Mechanical Resonator Using a Phase-Locked Loop

eess.SY ·2026-11-16 ·Frauke H. Niebel, Jan-Philipp Scheel, David Conrad, Hossein Shabanalinezhad, Matthias Graeser
similarity 0.59
Abstract · 2 pages, 2 figures, Sensor and Measurement Science International Conference (SMSI) 2027 conference

Magneto-mechanical resonators are wireless sensors that encode a measurand in their natural frequency. Existing systems estimate this frequency from repeated cycles of excitation and ring-down, which limits the precision and bandwidth range. Here, we introduce a continuous, phase-coherent readout based on a phase-locked loop. In a benchtop setup, one record stayed within 4 % of the precision-bandwidth limit over more than three decades of bandwidth, while conventional readouts remained about a factor of 4 above it.

0.26

Electromagnetic Micro-Guidewire Control in Large Workspaces

eess.SY ·2026-09-14 ·Jasan Zughaibi, Elia Jaggy, Valentin Gantenbein, Denis von Arx, Cristiano Sartini +7 more
similarity 0.56
Abstract

Electromagnetic navigation requires sufficient actuation at clinically relevant distances due to limited magnetic volumes and coil currents. We combine real-time pose feedback with constrained convex optimization, dynamic feedback, and repetitive control to achieve energy-efficient micro-guidewire steering inside realistic anatomical models. Experiments with a clinically oriented, three-coil electromagnetic navigation system and a 0.6 mm-diameter tip magnet demonstrate angular tracking with root-mean-square errors below 0.25 degrees at distances up to 55 cm from the coil cover. Nullspace current redistribution maintains accurate tracking under active 45 A coil-current constraints. Compared with conventional field alignment, we demonstrate that pose-dependent torque-based allocation substantially reduces current demand, with the efficiency benefit retained at a pose-feedback rate of 15 Hz. These results demonstrate how real-time state information and optimization can extend electromagnetic guidewire control toward clinically relevant working distances.

0.23

Quadratic Unconstrained Binary Optimization for Sparse Magnetoencephalography Source Localization

eess.SP ·2026-08-13 ·Arim Ryou, Kiwoong Kim
benchmark similarity 0.49
Abstract · 16 pages, 4 figures

Magnetoencephalography (MEG) source localization is an ill-posed inverse problem because distinct cortical source configurations can produce similar sensor-level fields. We formulate sparse multi-source localization as a quadratic unconstrained binary optimization (QUBO) problem combined with residual-aware candidate screening. Candidate source-location groups are generated from the sensor-space residual, fixed sensor-space templates are estimated for the resulting candidates, and active templates are jointly selected using data-fit, pairwise template interactions, and soft-cardinality terms. We evaluate the method using classical simulated annealing in controlled synthetic MEG simulations, primarily under a two-source condition, and compare it with MNE, dSPM, MxNE, LCMV, and RAP-MUSIC. Across 100 main-benchmark trials, QUBO achieved a mean cardinality-aware localization error of 8.45 mm, compared with 22.35 mm for MxNE, the best-performing baseline according to this metric, corresponding to a 62.2% reduction. The composite metric adds a 50 mm penalty per unit of source-count mismatch before normalization by the true source count. Because MxNE returned only one source in 35 trials, the reported reduction reflects both spatial localization and source-count performance. In separate sensitivity experiments, QUBO remained competitive across the tested sensor-noise and source-count conditions, although RAP-MUSIC performed comparably to or better than QUBO in some low-noise and three-source settings. The present experiments use classical simulated annealing and do not evaluate quantum hardware or claim quantum advantage. The resulting binary quadratic objective admits a direct Ising representation, enabling future evaluation on quantum-annealing and hybrid backends.

0.10

MagPillar: A Soft Magnetopillar Array Tactile Sensor for Robotic Surface Perception

cs.RO ·2026-11-01 ·Haotian Guo, Yu Feng, Hao Wu, Jiazhi Tang, Ningbin Zhang +1 more
similarity 0.48
Abstract

Robotic surface exploration benefits from tactile interfaces that accommodate contact and capture variations in surface characteristics. Herein, we report MagPillar, a tactile sensor inspired by spider tactile hairs that combines a magnetic pillar array with three-axis Hall sensing. A full-array mechanical and magnetic-field model characterizes how pillar deformation affects the superposed fields measured across the array, providing a physical basis for interpreting its contact responses. The compliant pillar architecture translates contact with surface textures and geometric features into distinct magnetic response patterns. Then, in robotic surface perception experiments, spectral features and logistic regression distinguish six material surfaces with an offline accuracy of 99.34% under within-session temporally blocked cross-validation. Continuous scans over periodic protrusions produce amplitude and peak-spacing variations consistent with changes in surface geometry. These findings connect compliant contact mechanics with distributed magnetic sensing, paving a new path for material recognition and qualitative surface-profile perception.

0.35

MAGNETAR: Multipath-Guided Spatial Posteriors for Transmitter Pose Inference in the Upper Mid-Band

cs.RO eess.SP ·2026-09-17 ·Haozhe Lei, Ruibin Chen, Yuhan Jiang, Ali Rasteh, Aditya Dhananjay +1 more
similarity 0.48
Abstract

Robots that localize a radio transmitter need more than a point estimate: in cluttered rooms, one measurement is often consistent with several transmitter locations and, because upper-mid-band antennas are directional, several headings. We present MAGNETAR, which infers a joint posterior over planar transmitter position and heading from a single asynchronous radio-frequency (RF) multipath snapshot, represented by angle-of-arrival and signal-to-noise-ratio estimates, given the room layout and receiver pose. Among our five neural scorers, MAGNETAR adopts a shared 2D U-Net conditioned on each candidate heading, jointly normalizing scores over a discretized position-heading grid. Training uses real-to-sim-calibrated 10 GHz simulations and a small measured subset. Grid-based joint posteriors outperform parametric ones on held-out simulations, the heading-conditioned scorer transfers best to robotic measurements, and fusing joint posteriors improves on fusing position-only marginals.

0.20

From Time to Channels: Robust and Efficient Local Flaw Detection in Steel Wire Ropes Using Tri-Axis MFL Signals

eess.SP ·2026-09-14 ·Siyu You, Yibo Zhang, Shengbo Xu, Yanhui Yang, Huayi Gou +4 more
similarity 0.46
Abstract

Steel wire ropes (SWRs) are critical load-bearing components whose local flaws (LFs) pose serious safety risks. Magnetic flux leakage (MFL) inspection commonly detects LFs from temporal or axial morphology, which can change with the sensing axis and operating condition. We show instead that LF responses remain localized over neighboring channels of a circular array. This observation motivates a channel-feature-oriented (CFO) detector that removes smooth channel backgrounds, applies circular matched filtering, and fuses spatially co-located tri-axis responses. Experiments performed on real-world equipment show that CFO attains the highest localization performance among three representative baselines, reaching F1@0.5/F1@0.7 scores of 73.9%/59.5%. It attains the best temporal localization performance under all four conditions and achieves at least 19.4 times the throughput of the evaluated signal-processing baselines. These results demonstrate that circular channel locality provides a robust LF representation across the evaluated operating conditions.

0.23