CS Paper Radar

Continuous Phase-Coherent Readout of a Magneto-Mechanical Resonator Using a Phase-Locked Loop

Frauke H. Niebel, Jan-Philipp Scheel, David Conrad, Hossein Shabanalinezhad, Matthias Graeser

eess.SY ·submitted 2026-11-16 15:30 UTC · v1

Abstract

Magneto-mechanical resonators are wireless sensors that encode a measurand in their natural frequency. Existing systems estimate this frequency from repeated cycles of excitation and ring-down, which limits the precision and bandwidth range. Here, we introduce a continuous, phase-coherent readout based on a phase-locked loop. In a benchtop setup, one record stayed within 4 % of the precision-bandwidth limit over more than three decades of bandwidth, while conventional readouts remained about a factor of 4 above it.

Comment
2 pages, 2 figures, Sensor and Measurement Science International Conference (SMSI) 2027 conference

Closest papers

Nearest neighbours by meaning across the whole index.

Gradient-Field Frequency Encoding for 1D Localization of Magneto-Mechanical Resonators

eess.SP eess.SY ·2026-10-05 ·Fabian Mohn, Martin Möddel, Tobias Knopp
similarity 0.59
Abstract · 4 pages, 3 figures

Magneto-mechanical resonators (MMRs) have emerged as promising passive sensors for wireless localization and remote inductive sensing in industrial and medical environments. However, fundamental limits on achievable localization accuracy using the spatial sensitivity profiles of receive coils remain a key challenge. In this work, we demonstrate that an MMR - comprising two permanent magnets in an anti-parallel arrangement - exhibits a measurable shift in its mechanical resonance frequency in response to an externally applied magnetic field, a property we exploit for spatial encoding. We derive and experimentally validate a method that maps frequency shifts of 1D positions within a known magnetic gradient field, demonstrating accurate localization along a linear trajectory. This gradient-field frequency encoding approach constitutes a conceptually distinct alternative to conventional sensitivity encoding with receiver coil arrays, with the potential to simplify hardware requirements while improving localization accuracy.

0.27

Giant Resonant Reflection Gain from Injection-Induced Quenching in a Tunnel Diode

eess.SY physics.app-phphysics.ins-det ·2026-09-16 ·Darmindra Arumugam, Jack Bush, Brook Feyissa
unusual similarity 0.49
Abstract

Negative-resistance microwave oscillators can simultaneously sustain autonomous oscillations and coherently scatter electromagnetic waves, enabling active reflection beyond conventional linear amplification. Here we demonstrate giant resonant reflection gain from synchronization-induced phase localization in a self-sustained tunnel diode oscillator operating near 2.96 GHz. Weak resonant RF injection drives a transition from a broadband free running state to a phase localized narrowband reflected carrier. The resulting reflected enhancement reaches 83.1dB relative to the injected signal and is accompanied by greater than order of magnitude linewidth collapse, nonlinear injection pulling, and a synchronization bandwidth of 15.84 kHz. Time resolved spectrograms directly resolve injection locking and frequency entrainment, while noisy Stuart Landau simulations reproduce the observed spectral concentration and detuning dependent gain roll off near the Hopf instability. Artificially increasing phase diffusion with broadband bias noise suppresses the reflected enhancement, confirming synchronization-induced quenching of phase fluctuations as the origin of the giant coherent reflection gain.

0.24

Instrument-Level Validation of Upper Sideband Syntonization Concept

eess.SP astro-ph.IM ·2026-09-09 ·Volodymyr Kudriashov, Manuel Martin-Neira
unusual similarity 0.48
Abstract · 10 pages, 9 figures

Upper Sideband Syntonization (USBS) is a two-way frequency-transfer concept proposed by the European Space Agency for distributed space radio interferometric systems. Previous investigations validated the concept primarily through frequency-stability and phase-transfer measurements. This work demonstrates the first end-to-end instrument-level validation of the USBS concept through coherent W-band cross-correlation measurements and image reconstruction. A P=2 USBS breadboard was integrated with a W-band radio interferometer developed for this test. The synchronized local oscillators (LOs) were evaluated through long-term cross-correlation measurements and coherent imaging of a point-like noise source. The results were compared with those obtained using a conventional common LO as well as two independent free-running LOs. The USBS-derived LOs maintained coherence over 500 s of cumulative effective integration time acquired over approximately five days of elapsed time and preserved inter-session phase stability over measurements spanning 40 days. The reconstructed image is nearly indistinguishable from that obtained with a common LO, whereas independent free-running LOs lead to severe coherence degradation, image distortion, and approximately 38 dB loss of peak response. The results demonstrate that USBS preserves the interferometric coherence required for W-band imaging and present the first end-to-end instrument-level validation of the USBS syntonization concept for future distributed space radio interferometric missions

0.30

A 140.5$μ$W, 99.8% Accuracy, 96.1dB SNR BioZ IC for Real-Time Cell Analysis with On-Demand Push-Pull Excitation and Continuous-Time $ΔΣ$ T-D Readout

eess.SP ·2026-10-24 ·Jiayang Li, Junzhe Chen, Xin Zhang, Peiqing Li, Liwen Zhang +13 more
published similarity 0.45
Abstract · Accepted for publication in ISSCC 2027, Paper 12.6. 8 pages, 7 figures

This paper presents a bioimpedance IC combining an on-demand push-pull driver and continuous-time $ΔΣ$ T-D readout to address the trade-off between SNR, accuracy and power consumption. The driver delivers 200$μ$App with $\leq$0.14% THD while consuming 80.3$μ$A. Using a 6MHz clock, the readout achieves 53.6ps effective timing resolution at a 4k$Ω$ load (0.1-4Hz noise integration). The IC achieves 96.1dB peak SNR, 99.8% magnitude accuracy and 0.13$^{\circ}$ phase error at a maximum power consumption of 140.5$μ$W.

0.35

An Input-Dependent Readout Phase for Resonant Sequence Models

cs.LG cs.CL ·2026-09-26 ·Shivesh Rane
similarity 0.43
Abstract

Sequence models with a fixed-size state avoid the quadratic cost of attention, but face a design choice. An input-dependent state transition gives content-dependent memory at the cost of FFT-based training, while a fixed transition keeps the O(T log T) convolutional path but reads memory the same way for every input. ResonatorLM, a recent model of the second kind, reads a bank of damped complex oscillators through a fixed learned phase per head. We make that readout phase a function of the current token, which adds input dependence to the read only, keeps the convolution exact, and costs 0.2 percent more parameters. An analysis of the untrained bank shows that phase does encode elapsed time, but an ordinary token falls below the background within 2-8 steps and no choice of damping extends linear reconstruction beyond about 16 tokens. In 6M-parameter character-level models on WikiText-2, the input-dependent phase matches the original at the training length and removes its failure beyond it: trained on 256 tokens and tested on 1024, perplexity falls from 12.81 to 3.76. We trace the failure to long-memory heads that accumulate more history than training exposed them to. The learned phase tracks the current character rather than distance and does not improve retrieval.

0.31

Observable Spectral Framework for Noisy Amplitude Amplification: Stopping Stability and Correction

cs.ET quant-ph ·2026-11-16 ·Ge Zhong, Charith Jayasekara, Nisal De Silva, Muhammad Usman, Muhammad Aamir Cheema +1 more
similarity 0.42
Abstract · 28 pages, 5 figures, 4 tables; includes 38-page supplementary material (10 figures). Submitted to EPJ Quantum Technology

Stopping rules for noisy amplitude amplification often rely on channel-specific success-probability formulas, limiting their transfer across noise mechanisms. We develop an observable spectral framework for stationary noisy standard amplitude amplification under explicit leading-mode, spectral-separation, and residual-control conditions. Within this class, the first amplification lobe has a damped-oscillatory leading component and a bounded non-leading contribution. We derive how frequency shift, damping, and observable phase offset displace the leading peak, and establish sampled-gap criteria for retaining the ideal integer stopping depth, certifying recalibration, or selecting a robust candidate window. In single-target Grover search, frequency and damping errors have stopping-coordinate sensitivities proportional to the search-space size, whereas phase offsets scale with its square root; residual modes can independently reverse the ordering of neighbouring depths. Analytical constructions, circuit simulations, finite-shot inference, and calibration-derived device-like trajectories examine these predictions and their operational limits. For a 64-element search, an a posteriori sampled-set check selects depth five over six, with success probability increasing from 0.595 to 0.626. The resulting theory links observable spectral dynamics to conditional integer stopping guarantees without requiring a separate microscopic channel solution.

0.34

13,000-Fold Frequency Down Conversion From 280 MHz to 21 kHz Using Mechanical Frequency Combs

eess.SP ·2026-11-05 ·Ian Anderson, Zihuan Liu, Vivek Tallavajhula, Yen-Chen Wang, Tzu-Hsuan Hsu +2 more
unusual similarity 0.42
Abstract · 4 pages, 6 figures

Optical frequency combs bridge the microwave and terahertz regimes by down-converting terahertz optical energy into microwave signals. A photodetector converts the comb's equally spaced lines, generated through optical nonlinearities, into a low-frequency tone at their spacing. Here, we present the first mechanical version of this process, using mechanical frequency combs to downconvert energy over 4 orders of magnitude, from the MHz to kHz regime. Thin-film lithium niobate (LN) is used to design an acoustic resonator with a wide range of mode frequencies. We achieve phononic comb excitation from 250 MHz to 900 MHz and compare the electrical and laser Doppler vibrometer (LDV) measurements at 277 MHz. We then show the low-frequency spectrum of the devices, highlighting mechanical motion at the comb's spacing and demonstrating energy transfer from 277 MHz to 21 kHz.

0.30

Dynamical Diversity for Reservoir Computing in Reconfigurable Nanomechanics

cs.ET physics.app-phcs.NE ·2026-09-24 ·Humayun Ahmed, Inês S. Garcia, Filipa C. Mota, Muhammad Asim, Ghaith Mahook +5 more
similarity 0.42
Abstract · 51 pages including the Supplementary Information

Physical reservoir computing uses nonlinear dynamics and a trained linear readout to process information. Nanoelectromechanical (NEMS) resonators combine geometric Duffing nonlinearity with fading memory, but most electromechanical implementations use a single resonance mode. Here, we demonstrate reservoir computing with two interacting modes of a single NEMS resonator measured through one readout port. We introduce dynamical diversity through complementary modal drive settings: the same input sequence is replayed under different allocations of drive amplitude between the modes, and the responses are concatenated into a single feature matrix. This multiplexing expands the representation available to the readout without additional devices or training of internal parameters. On NARMA-2, it reduces variance-normalized test error more than 28-fold relative to single-mode operation and more than threefold relative to the best individual two-mode setting. Linear memory-capacity measurements show that accessible recall spans only a few symbols at the tested symbol duration. Its rapid decline with delay, consistent with mechanical dissipation, accompanies rising NARMA error and the eventual loss of multiplexing gains at higher orders. We also use electrical feedthrough as an internal reference for assessing the computational contribution of the NEMS response. Separate linear readouts are trained on feedthrough features and features derived from the measured NEMS response, using the same recordings and matched drive settings and processing. On challenging nonlinear mapping tasks, the multiplexed NEMS features yield substantially lower errors than the feedthrough features. These results demonstrate how dynamical diversity through variations in modal drive amplitudes expands the computational capability of a single multimode NEMS resonator.

0.30