CS Paper Radar

Electromagnetic Micro-Guidewire Control in Large Workspaces

Jasan Zughaibi, Elia Jaggy, Valentin Gantenbein, Denis von Arx, Cristiano Sartini, Jonas Kühne, Oliver Brinkmann, Pascal Ernst, Salvador Pané, Quentin Boehler, Michael Muehlebach, Bradley J. Nelson

eess.SY ·submitted 2026-09-14 21:17 UTC · v1

Abstract

Electromagnetic navigation requires sufficient actuation at clinically relevant distances due to limited magnetic volumes and coil currents. We combine real-time pose feedback with constrained convex optimization, dynamic feedback, and repetitive control to achieve energy-efficient micro-guidewire steering inside realistic anatomical models. Experiments with a clinically oriented, three-coil electromagnetic navigation system and a 0.6 mm-diameter tip magnet demonstrate angular tracking with root-mean-square errors below 0.25 degrees at distances up to 55 cm from the coil cover. Nullspace current redistribution maintains accurate tracking under active 45 A coil-current constraints. Compared with conventional field alignment, we demonstrate that pose-dependent torque-based allocation substantially reduces current demand, with the efficiency benefit retained at a pose-feedback rate of 15 Hz. These results demonstrate how real-time state information and optimization can extend electromagnetic guidewire control toward clinically relevant working distances.

Closest papers

Nearest neighbours by meaning across the whole index.

Information-based Unified Design Framework for NMR Magnetic Tracking System

cs.RO eess.SY ·2026-10-13 ·Seçkin Eren Yetim, Mehmet Efe Tiryaki
similarity 0.58
Abstract · 6 pages, 6 figures, journal letter submission

Nuclear magnetic resonance (NMR) magnetic tracking offers a promising alternative to magnetic resonance imaging (MRI)-based localization for medical robotic guidance. However, scalar field measurements and field-aligned marker moments constrain position and orientation tracking, requiring careful configuration design. We present a unified information-based framework that uses local covariance analysis to evaluate receiver geometry, marker separation, and external source configuration in on/off-board NMR tracking. Numerical evaluation shows that planar-array precision depends jointly on receiver count and geometry, with triangular lattice arrays achieving the lowest best-case position uncertainty among the evaluated layouts for 9--20 receivers. Two spatially separated, field-aligned markers enable device-axis tracking, with predicted angular uncertainty below $2^\circ$ at the evaluated workspace center for suitable marker separations. We further establish point-dipole source--receiver duality, unifying the analysis of on/off-board NMR tracking. These

0.21

Gradient-Field Frequency Encoding for 1D Localization of Magneto-Mechanical Resonators

eess.SP eess.SY ·2026-10-05 ·Fabian Mohn, Martin Möddel, Tobias Knopp
similarity 0.56
Abstract · 4 pages, 3 figures

Magneto-mechanical resonators (MMRs) have emerged as promising passive sensors for wireless localization and remote inductive sensing in industrial and medical environments. However, fundamental limits on achievable localization accuracy using the spatial sensitivity profiles of receive coils remain a key challenge. In this work, we demonstrate that an MMR - comprising two permanent magnets in an anti-parallel arrangement - exhibits a measurable shift in its mechanical resonance frequency in response to an externally applied magnetic field, a property we exploit for spatial encoding. We derive and experimentally validate a method that maps frequency shifts of 1D positions within a known magnetic gradient field, demonstrating accurate localization along a linear trajectory. This gradient-field frequency encoding approach constitutes a conceptually distinct alternative to conventional sensitivity encoding with receiver coil arrays, with the potential to simplify hardware requirements while improving localization accuracy.

0.27

Magnetic based In-situ Self 3D Pose Estimation for a Modular Soft Tendon-Driven Continuum Robot via IMU-Fusion

cs.RO eess.SPeess.SY ·2026-09-30 ·Zheng Cao, Guo Ning Sue, Xiangyun Bu, David Quinn, Junzhe Hu +1 more
similarity 0.55
Abstract

Continuum robots are well suited for gentle manipulation because of their inherent compliance and ability to adapt to complex environments. However, their continuously deformable structure makes accurate configuration estimation challenging, particularly when external vision systems are unavailable or obstructed. In this work, we present an embedded pose sensing framework that combines inertial measurement units (IMUs) and active magnetic fields to estimate the robot configuration without relying on external cameras. The angular measurements from the IMU and magnetic-field references are fused to improve local orientation estimation and reduce accumulated orientation error during operation. This pose sensing scheme achieves an update rate of 16.7~Hz, allowing real-time feedback. The proposed system is experimentally validated through closed-loop control, where the estimated robot configuration is used to maintain the end-effector at a desired position while interacting with an object. These results demonstrate the potential of distributed magnetic--inertial sensing for real-time pose estimation and closed-loop control of continuum robots.

0.11

Magflow: Differentiable Simulation of Industrial-Grade 6D Magnetic Levitation

cs.RO cs.LGeess.SY ·2026-11-17 ·Philipp Hartmann, Jannick Stranghöner, Klaus Neumann
top venuecode/data similarity 0.54
Abstract · 8 pages, 5 figures, 1 table. Accepted for publication in IEEE Robotics and Automation Letters (RA-L). Project page: https://sites.google.com…

Magnetic levitation with six-degrees-of-freedom enables frictionless transport and micrometer-scale positioning in principle, but low-level control is inherently challenging due to its complex and unstable dynamics. Industrial systems typically rely on deep hardware-software co-design, where mover and stator geometries are jointly designed to enable a compact, hand-crafted approximation of the electromagnetic force computation, thereby keeping control computationally tractable at kilohertz rates. However, this approach imposes overly conservative constraints on the operating workspace and the range of supported mover topologies. Instead of reducing the underlying physics to a hand-crafted approximation, we compute the physics directly. We introduce Magflow, a fully differentiable, GPU-parallel simulator for 6D magnetic levitation. It is used to train the first neural controller for an industrial-grade 6D magnetic levitation system that is learned purely from simulated physics. We show that the learned neural controller transfers zero-shot from simulation to real hardware while satisfying hard real-time constraints at 4 kHz. The learned controller achieves qualitatively new behaviors and even levitates a mover topology for which no hand-crafted solution exists. These results demonstrate that co-design is not a physical necessity for 6D magnetic levitation control. More broadly, control learning from simulated physics can find solutions beyond the reach of control engineering in demanding industrial domains. Source code and demonstration videos are publicly available at https://sites.google.com/view/magflow.

0.58

Magnet-Aware Control of Legged Robots

cs.RO ·2026-10-06 ·J. Playan Garai, S. B. Djuve, C. McGreavy, M. Khadiv
similarity 0.54
Abstract

Autonomous robots can increase uptime and reduce human exposure in Big Science facilities, but strong magnetic fields needed for their operation corrupt sensors and induce pose-dependent mechanical wrenches that destabilize robots and challenge conventional reactive controllers. This paper presents a control framework for modeling, estimating, and dynamically compensating for spatially varying magnetic wrenches acting on legged robots to improve robustness in these fields. We introduce a custom physics plugin for the MuJoCo simulator to model magnetic forces on rigid-body elements, alongside an inverse field-estimation framework to infer the latent magnetic field directly from quadruped dynamic responses and any number of sensor readings. Furthermore, we develop a Magnet-Aware Model Predictive Control (MPC) and Whole-Body Control (WBC) architecture that predicts and counteracts magnetic perturbations during locomotion to increase the range of magnetic fields in which the robot can operate. The effectiveness of the framework is validated through both simulation and physical hardware experiments. We show our method increases the the maximum rejectable disturbances from magnetic field in the force space by a factor of 2.5 and and between 1.6-2 times in torque space compared to a non-compensated system. Within the proposed magnetic field, this constitutes an increase in the area in which the robot can operate by 29,34% of which 10,84% would have previously caused an immediate collapse to non-compensated controllers.

0.28

Damping Oscillations in a Spherical Pendulum Inclinometer Using Vector-Based Control

eess.SY ·2026-08-31 ·Fernando Capes, Mikael Andreas Bianchi, Roberto Gardenghi, Manuel Alò
similarity 0.53
Abstract

This paper addresses disturbance-induced oscillations in high-precision pendulum-based inclinometers, which reduce measurement availability despite the long-term stability of gravity-referenced sensing. To actively suppress these oscillations, a contactless six-coil electromagnetic actuation system is developed, together with a control framework that generates, in real time, the planar damping force required by the controller despite the nonlinear, unilateral, and bounded nature of magnetic actuation. The proposed approach combines a control-oriented nonlinear model of the spherical pendulum, observer-based feedback control, and a constrained force-allocation scheme that maps the desired vector force into feasible coil currents. Experimental validation on a prototype demonstrates attenuation of the dominant oscillatory mode up to 31.11 dB and a marked reduction in transient duration, with the 50\% decay time decreasing from 11.10 s without control to 1.01 s at the most favorable operating point. The results also highlight a trade-off between transient speed and residual oscillation, demonstrating both the effectiveness of the proposed damping strategy and its value as a practical design framework for high-precision inclinometer systems.

0.25

Contrast-Free Autonomous Navigation of Untethered Endovascular Microrobots Using Single-Plane Fluoroscopy

cs.RO ·2026-08-31 ·Husnu Halid Alabay, Tuan-Anh Le, Ping Wang, Hakan Ceylan
similarity 0.52
Abstract · 34 pages, 9374 words

Reliable three-dimensional (3D) navigation of magnetically actuated untethered microrobots remains a major barrier to clinical translation. X-ray fluoroscopy is the standard real-time imaging modality for endovascular procedures, but single-plane fluoroscopy provides only a two-dimensional (2D) projection, eliminating depth information and complicating autonomous navigation. Recovering this information through biplane imaging or repeated contrast-enhanced angiography increases procedural complexity, radiation exposure, or contrast burden. Here, we introduce VISTA (Virtual Integration for Spatial Tracking and Autonomy), a digital twin framework enabling contrast-free autonomous navigation under single-plane fluoroscopy. VISTA reconstructs vascular anatomy as a 3D digital twin, discretizes the vessel centerline into navigation milestones, and assigns the detected 2D robot position to the nearest projected milestone. Consecutive milestones define the local vessel orientation used to generate magnetic actuation commands, converting single-plane fluoroscopic observations into topology-constrained navigation states without requiring contrast injection during navigation. VISTA is demonstrated across anatomically distinct vascular phantoms under continuous flow and within the inferior vena cava of a live rat in vivo. Compared with conventional fluoroscopic human-in-the-loop control, VISTA reduced navigation time by up to 62%, corrective actuation commands by up to 98%, and radiation exposure by up to 57%. These results establish VISTA as a digital twin-guided framework for contrast-free autonomous navigation of untethered endovascular microrobots using widely available single-plane fluoroscopy.

0.31

Shaft-Configuration-Adaptive Catheter Tip Position Estimation via Motor-History Conditioned Residual Learning

cs.RO eess.SY ·2026-09-22 ·Peihan Zhang, Michael C. Yip, Ankur Kapoor, Young-Ho Kim
similarity 0.52
Abstract

Tendon-driven continuum manipulators are widely used in medical applications, where accurate tip-position estimation is essential for precise navigation and instrument positioning. However, patient anatomy and procedural setup impose task-dependent unknown shaft configurations, while friction, slack, and compliance introduce hysteresis, making tip estimation challenging. This paper presents a motor-history-conditioned gated recurrent unit (GRU) residual estimator for three-dimensional catheter tip estimation without direct shaft-configuration sensing. First, an initial multidirectional sweep strategy is applied to calibrate a geometric catheter model backbone, and encode the motor-angle and drive-torque response into a shaft-configuration context vector. During subsequent motion, the context conditions a GRU that predicts a task-space residual correcting this backbone, relying on motor measurements alone. The context remains fixed for the current shaft configuration, while the recurrent state captures the evolving actuation history. Across four disposable intra-cardiac echocardiography catheters and 16 bent shaft configurations, the method achieves 3.3mm open-loop tip RMSE, a 59% reduction relative to the constant-curvature baseline.

0.39