CS Paper Radar

Regional Frequency Constrained Dispatch Method Considering Spatial-joint Stochastic Disturbances and Contingencies

Nian Liu, Yubing Chen, Kai Jiang, Jiahao Liu, Cheng Wang, Tianshu Bi

eess.SY ·submitted 2026-09-04 12:39 UTC · v1

Abstract

The increasing penetration of renewable energy challenges frequency stability due to high variability and declining inertia. Traditional frequency security constrained dispatch methods fail to capture regional frequency heterogeneity and spatially correlated stochastic disturbances, resulting in inaccurate frequency security enforcement. To address this, a regional frequency constrained dispatch method is proposed, considering the spatially joint stochastic disturbances and contingencies. Firstly, a multi-regional frequency response model is constructed, incorporating the Vine-Copula based characterization of regional stochastic disturbances and regional frequency support. Then, a progressive latent-bottleneck physics-informed neural network is applied to characterize differential frequency nadir terms and regional frequency support integral terms via an encoder-decoder architecture, which enables optimization compatible expressions of system frequency dynamics. Finally, a day ahead dispatch model is developed in which regional stochastic frequency constraints are embedded using a CVaR-based formulation. A case study on the IEEE 118-bus system shows that the proposed method outperforms the unified center of inertia embedded approach in mitigating regional frequency violations, with the regional frequency nadir and RoCoF improved by 32.76% and 2.06%, respectively.

Closest papers

Nearest neighbours by meaning across the whole index.

Grid-Aware Assessment of Forced Oscillations from Spatially Distributed Large Loads

eess.SY ·2026-11-17 ·Min-Seung Ko, Hao Zhu
similarity 0.60
Abstract

This paper develops a unified analytical framework for assessing forced oscillations induced by spatially distributed large-load fluctuations to determine their grid-aware fluctuation magnitudes. Emerging computational loads, such as hyperscale datacenters, present cyclic power variations with dynamic impacts depending on the waveform characteristics, forcing frequency, and source location. Our grid-aware framework represents these fluctuations using deterministic harmonic and probabilistic spectral models, and analyzes the resulting bus-wise frequency deviations based on a generic grid frequency-response model. Deterministic, risk-aware, and band-based probabilistic severity measures are further developed to obtain admissible fluctuation limits under different assumptions on frequency and phase uncertainty. We also formulate a security-constrained (SC) optimization of locational fluctuation magnitudes among existing large loads, accounting for their aggregated frequency deviation level. Case studies on the IEEE 39-bus and 14-generator Australian systems validate the proposed severity measures and admissible limit analysis. The SC optimization results further show that distributing a given amount of aggregate fluctuation toward dynamically less sensitive locations can substantially reduce system-wide oscillation severity.

0.35

Frequency-Security-Aware Real-Time Economic Dispatch with Data Center UPS Flexibility for Inertia and Primary Frequency Response Services

eess.SY ·2026-11-13 ·Shengyi Wang, Liang Du
hot direction similarity 0.59
Abstract

The increasing penetration of renewable energy and the rapid growth of AI data centers are introducing significant challenges to power system frequency security. There is an urgent need to identify grid-compatible resources capable of providing fast frequency support. This paper proposes a frequency-security-aware real-time economic dispatch (RTED) model that enables data center (DC) uninterruptible power supply (UPS) systems to provide steady-state power balancing, inertia response, and primary frequency response (PFR) services. Specifically, tractable analytical frequency-security constraints are derived and incorporated into the RTED framework through second-order cone programming (SOCP) formulation. The proposed model jointly optimizes energy, reserve, and inertia to minimize system operation cost while preventing under-frequency load shedding (UFLS). Numerical validation on a modified IEEE 39-bus system demonstrates that the proposed RTED model with UPS flexibility can economically support system operation and significantly improve frequency security under active-power deficit disturbances.

0.30

Frequency-Calibrated Decision-Focused Learning for BESS Dispatch Under Renewable Uncertainty

eess.SY ·2026-10-30 ·Zihan Meng, Chenxi Hu, Xin Cui, Francis Yunhe Hou
hot direction similarity 0.56
Abstract

Battery energy storage system (BESS) flexibility depends on state of charge and intertemporal operating constraints. Renewable forecast errors of similar magnitudes can lead to different BESS dispatch results. An error may alter early charging or discharging decisions and reduce the flexibility available for subsequent regulation, while another may have little effect on the resulting schedule. To account for these unequal consequences, this paper proposes Frequency-Calibrated Decision-Focused Learning (FC-DFL), which trains renewable predictors using the realized operating costs of their induced BESS schedules. Gaussian smoothing and solver-based zeroth-order estimation provide training feedback without requiring differentiating through the non-differentiable mixed-integer BESS dispatch problem. The same decision feedback is further combined with prediction sensitivity to develop a decision-oriented XAI method that identifies the input features and forecast periods most consequential to BESS operation. Case studies using German wind and solar data show that FC-DFL reduces the integrated absolute frequency-deviation metric by 6.05% and decision regret by 23.92% relative to accuracy-based predict-then-optimize method. The XAI analysis further demonstrates that the identified high-impact forecast periods produce 2.84 times larger average absolute changes in realized operating cost than low-impact periods. These findings highlight the importance of incorporating downstream decision-making outcomes into renewable forecasting and demonstrate the value of FC-DFL in improving BESS regulation and providing operationally meaningful forecast explanations.

0.24

Converter-Grid Interaction Stability Guaranteed Safe Deep Reinforcement Learning for Energy Storage Systems in Grid Frequency Support

eess.SY ·2026-09-15 ·Fei Liu, Mengfan Zhang, Zhipeng Li, Frede Blaabjerg, Qianwen Xu
similarity 0.55
Abstract · 10 pages, 13 figures. Submitted to IEEE Transactions on Smart Grid

The growing integration of converter interfaced renewable energy resources (RESs) intensifies stability challenges. Energy storage system (ESS) can provide fast and flexible frequency support to mitigate frequency deviations. However, the interface converter of ESS may encounter converter-grid interaction stability issues. This paper proposes a converter-grid interaction stability guaranteed safe DRL (CIS-DRL) method for ESS integrated power systems to achieve frequency regulation. We first obtain a double DNN-based stability region to identify the guaranteed converter-grid interaction stability. Next, a novel converter-grid interaction stability Safe-TD3 (CIS-STD3) algorithm is designed that integrates a stability feasibility projection layer to map unsafe actions into stable action set before execution, enforcing converter-grid interaction stability as a hard constraint throughout learning process. The proposed approach enables ESS for grid frequency support with 100% converter-grid interaction stability without violations. Experimental results show that the proposed CIS-DRL method achieves improved frequency regulation performance while preventing unstable operating points, demonstrating its practical applicability for real time ESS frequency support.

0.27

Quantifying Power to Voltage and Frequency Dynamics for Oscillation Propagation Assessment

eess.SY ·2026-09-03 ·Onur Alican, Dionysios Moutevelis, Marc Cheah-Mañe, Oriol Gomis-Bellmunt, Eduardo Prieto-Araujo
benchmark similarity 0.54
Abstract

The integration of Inverter-Based Resources (IBRs) into power systems introduces multi-timescale dynamics and oscillations which may propagate to distant areas and endanger the safe system operation. These oscillations pose a significant challenge as their source, frequency, and propagation pathways are often challenging to identify in large interconnected systems, comprising numerous synchronous machines and IBRs. For the above reasons, analytical tools that identify the sensitivity of the system to oscillations within a large frequency spectrum, affecting both voltage and frequency variables across various network locations, are of interest. This paper addresses this topic by introducing a frequency-domain framework based on linear analysis, which characterizes the sensitivity to oscillations of each network bus voltage and of each generation unit frequency. Within this framework, two quantitative indicators are proposed, namely the Frequency Sensitivity Index (FSI) and Voltage Sensitivity Index (VSI). These indexes are derived analytically from the transfer functions which relate the active and reactive power injections to each bus with the voltage and frequency variables across the network, derived from the linear Electromagnetic Transient (EMT) power system model. The proposed indices quantify the sensitivity of the system to oscillations of different type and frequency, providing insights for both oscillation detection and propagation analysis. The methodology is applied to a case study based on the modified IEEE 68-bus benchmark system under partial and full IBR penetration, while its accuracy is validated through EMT time-domain simulations using linear and nonlinear models developed in Matlab/Simulink environment.

0.29

Graph Neural Network Prediction of Frequency Nadir and RoCoF Under Topology Variations

eess.SY ·2026-11-13 ·Linhan Fang, Fan Jiang, Xingpeng Li
similarity 0.54
Abstract

Accurate prediction of frequency dynamics under varying network topologies is essential for rapid frequency security assessment, whereas repeated electromagnetic transient (EMT) simulations are computationally intensive. This paper develops a topology-aware graph neural network with a radial basis function Kolmogorov-Arnold network (RBF-KAN) regression head, termed RK-GNN, to predict frequency nadir and maximum absolute rate of change of frequency (RoCoF). Scenarios combine load scaling, regional load redistribution, and generator redispatch with intact, N-1, and N-2 transmission topologies. After checks for network connectivity, generator reference limits, and numerical consistency, the retained scenarios are simulated in PSCAD to construct the reference dataset. The RK-GNN is evaluated against a conventional deep neural network (DNN) and a baseline GNN. On the IEEE 39-bus system, the RK-GNN reduces the mean absolute errors (MAEs) of nadir and RoCoF by 48% and 59% relative to the DNN and by 42% and 61% relative to the baseline GNN. Incorporating the bridge indicator and disturbance hop distance yields further MAE reductions of 27% and 54%. These results show that the proposed topology-aware architecture provides accurate prediction of both frequency metrics under varying topologies and substantially reduces the need for repeated EMT simulations.

0.23

Optimal Allocation of Grid-Forming Frequency Shaping Control

eess.SY ·2026-09-21 ·Zhaomin Lyu, Ding Zhang, Yan Jiang
similarity 0.54
Abstract

Various inverter-based control strategies have been proposed to improve frequency security for power systems with high renewable penetration. Among them, the grid-forming frequency shaping control is particularly promising due to its ability to shape the post-contingency aggregate system frequency dynamics into first-order with prescribed rate of change of frequency (RoCoF) and steady-state frequency deviation. Moreover, the shaped aggregate dynamics depends on the harmonic sum of all inverter transfer functions rather than on their distribution. In light of this, here we explore how to allocate shaping control resources to minimize the transient control effort needed to achieve ideal coherent dynamics. We formulate it as a constrained optimization problem by tackling two main difficulties. First, we make the squared $\mathcal{H}_2$ norm legitimate quantification of transient control cost under step power imbalances through a system transformation. Second, we simplify the $s$-domain constraint for Nadir elimination into a standard constraint that is easy to implement in optimization. The resulting non-convex optimization problem can be solved by existing successive convexification method. The effectiveness of the allocation has been verified on the modified Icelandic Power Network test case.

0.28

Approximating Energy-Regulation Feasible Region of Virtual Power Plants: A Data-driven Inverse Optimization Approach

eess.SY math.OC ·2026-08-26 ·Ruike Lyu, Hongye Guo, Qixin Chen
publishedhighly cited similarity 0.54
Abstract · Published in: 2024 IEEE Power & Energy Society General Meeting (PESGM)

System operators will probably allow virtual power plants (VPPs) to submit their feasible region (FR) for market clearing and dispatch. A VPP needs to determine its FR to submit as a whole based on the individual operation model of its internal distributed energy resources (DERs), which is an FR aggregation problem. Existing FR aggregation approaches rely on analytical methods, which have issues with generality and adaptability. In this paper, we propose a data-driven approach to approximate the energy-regulation FR of VPPs. It adopts the virtual battery model to approximate the aggregate FR of a VPP and determines the model parameters through inverse optimization based on generated multi-scenario operation data using the original operation model. Numerical tests verified the accuracy of the proposed method. We believe that our work helps to better leverage the flexibility of DERs.

0.63