Graph Neural Network Prediction of Frequency Nadir and RoCoF Under Topology Variations

Linhan Fang, Fan Jiang, Xingpeng Li

eess.SY ·submitted 2026-11-13 05:11 UTC · v1

Abstract

Accurate prediction of frequency dynamics under varying network topologies is essential for rapid frequency security assessment, whereas repeated electromagnetic transient (EMT) simulations are computationally intensive. This paper develops a topology-aware graph neural network with a radial basis function Kolmogorov-Arnold network (RBF-KAN) regression head, termed RK-GNN, to predict frequency nadir and maximum absolute rate of change of frequency (RoCoF). Scenarios combine load scaling, regional load redistribution, and generator redispatch with intact, N-1, and N-2 transmission topologies. After checks for network connectivity, generator reference limits, and numerical consistency, the retained scenarios are simulated in PSCAD to construct the reference dataset. The RK-GNN is evaluated against a conventional deep neural network (DNN) and a baseline GNN. On the IEEE 39-bus system, the RK-GNN reduces the mean absolute errors (MAEs) of nadir and RoCoF by 48% and 59% relative to the DNN and by 42% and 61% relative to the baseline GNN. Incorporating the bridge indicator and disturbance hop distance yields further MAE reductions of 27% and 54%. These results show that the proposed topology-aware architecture provides accurate prediction of both frequency metrics under varying topologies and substantially reduces the need for repeated EMT simulations.

Closest papers

Nearest neighbours by meaning across the whole index.

Learned Graph Bases for Neural Operators on Power-System Transients

eess.SY ·2026-10-11 ·Shubhan Bhattacharya, Avi Bagchi
similarity 0.59
Abstract

Fourier neural operators predict power-system transient trajectories with high accuracy. We extend this line of work by examining the choice of spatial spectral basis, studying both the graph Fourier transform derived from the grid's own coupling network and learnable bases trained from that starting point and from a Fourier control. Evaluated in one controlled pipeline across three protocols spanning unseen fault locations and shifted operating regimes, the learnable bases improve on a parameter- and budget-matched DFT variant by 7-14% in distribution, with per-case significance on both in-distribution protocols and no loss on the third; the gain comes from adaptation rather than from the coordinates alone. We further characterize the regime dependence of this gain, identifying its cause, locus, and continuity, and show that a resolution requires no new model: averaging the learned and frozen variants gives the best shift-robust predictor, while their disagreement provides a label-free alarm that flags every shifted case with no false alarms.

0.22

A Benchmark Graph Dataset for Transient Stability Assessment of the IEEE 9-Bus System: 20,000 Scenarios with Full Generator Trajectories

eess.SY ·2026-08-18 ·Hussein Suprême, Martin de Montigny, Arnaud Zinflou
publishedbenchmark similarity 0.59
Abstract · Descriptor Open dataset IEEE9

Transient stability assessment determines whether a power system retains synchronism after a large disturbance. Machine-learning surrogates can accelerate it, but progress is limited by the lack of open datasets that combine dynamic ground truth, network graph structure, and machine parameters. We release a benchmark of 20,000 three-phase-to-ground fault scenarios on the IEEE 9-bus system. Each scenario couples an AC power-flow operating point with a detailed electromagnetic-transient simulation of the post-fault response. Every record provides the network as an attributed graph (nine buses, eighteen directed branches, ten node and twelve edge features), the full rotor-angle and speed trajectories of the three generators, the static machine constants, the fault description, and a center-of-inertia binary stability label. Wide load and generation scalings across eighteen fault locations yield a near-balanced distribution (48.96\% stable, 51.04\% unstable). Generation is deterministic and fully reproducible through fixed seeds and public code. The dataset is distributed on IEEE DataPort under a persistent DOI and supports stability classification, trajectory prediction, margin and critical-clearing-time estimation, and the comparison of topology-aware, physics-based, and hybrid learning methods.

0.43

Benchmarking Graph Neural Networks for AC Power Flow: The Role of Inductive Biases and Physical Constraints

cs.LG cs.AI ·2026-10-28 ·Federico Clerici, Ferran Bohigas-Daranas, Hamid Latif-Martínez, Eduardo Prieto-Araujo, Oriol Gomis-Bellmunt +1 more
benchmark similarity 0.58
Abstract

Fast and accurate models for AC power flow (ACPF) are increasingly important as modern electrical grids require more frequent system analyses. Graph neural networks (GNNs) naturally exploit electrical grid topology, yet the effects of architectural design choices on predictive performance remain poorly understood given differences in graph representations and evaluation settings across studies. We present a unified benchmark of representative GNN architectures for ACPF prediction under a common experimental framework. All models use identical preprocessing and training procedures and comparable parameter budgets, isolating the impact of message-passing mechanisms and inductive biases. We also analyze errors by distance from the slack bus and systematically ablate key design components. We evaluate predictive accuracy and physical consistency on the IEEE 14-bus and IEEE 118-bus systems. Results indicate that anisotropic message-passing architectures offer the most favorable trade-off between predictive accuracy and physical consistency under the studied parameter and topology constraints. Explicit edge features encoding line impedances and global context aggregation are particularly important for representing electrical interactions and system-wide dependencies, especially for voltage-angle predictions on the topologically bottlenecked IEEE-118 grid. Under a budget with approximately fixed parameters, two or three message-passing layers generally provide the best balance between depth and representation width, while additional depth offers no consistent improvement. Ablations also show that standard residual and root connections are not necessarily beneficial in shallow models, and that aggregation operators involve trade-offs between statistical accuracy and physical consistency. These results provide practical guidelines for designing graph-based power system models.

0.17

Foundation Models Meet Power Grid Topology for Cascade Prediction

eess.SY ·2026-10-23 ·Soumav Biswas, Mia Naeini
similarity 0.58
Abstract · 10 pages

Accurate early-stage prediction of cascading failure severity is essential for assessing the vulnerability of power transmission networks. However, existing data-driven approaches often rely on network-specific representations, limiting their generalizability across power system topologies. This work investigates the complementary capabilities of Large Language Models (LLMs) and Graph Neural Networks (GNNs) for cascading failure severity prediction. First, standalone LLM predictors are developed using a LoRA-fine-tuned LLaMA-3-8B-Instruct model with varying degrees of topological information. A hybrid Graph-LLM fusion framework is then proposed, integrating a Topology-Aware Graph Attention Transformer (TAGAT) with the LLM through confidence-gated fusion. TAGAT captures structural dependencies among transmission lines, while the LLM extracts representations from early-stage power-flow observations and aggregated cascade descriptors. The frameworks are evaluated on 30,000 simulated cascading failure scenarios for each of the IEEE 118-bus and IEEE 300-bus systems. Using only the first four cascade steps, the hybrid framework achieves weighted F1 scores of 0.94 and 0.92, respectively. In cross-system transfer from IEEE 118-bus to IEEE 300-bus, it achieves 0.72 zero-shot accuracy, improving to 0.83 with limited target-system calibration, outperforming standalone models and conventional baselines. These results show the potential of combining graph-based structural learning with foundation models to improve cascading failure severity prediction and cross-system transferability.

0.24

Droop-Aware Foundation Model Power Flow

cs.ET ·2026-09-20 ·Khezr Sanjani, Peng Zhang
similarity 0.56
Abstract

This paper develops a droop-aware extension of the GridFM power systems foundation model, embedding droop gains and frequency/voltage deadband parameters as per-bus node features to enable control-aware AC power-flow analysis. Existing power-flow datasets encode only static electrical features, conflating operating points from qualitatively different control regimes; this work resolves that gap by exposing droop and deadband parameters as structured node features, with deadband discontinuities handled through a smooth tanh approximation that preserves solver differentiability. A transformer-based graph neural network is pre-trained on masked reconstruction and fine-tuned on the resulting control-aware datasets. The framework is validated against PSCAD electromagnetic-transient simulations on a two-bus system (0.11% maximum steady-state error) and cross-validated against an independent PyPower droop solver on the IEEE 24-bus RTS. On the 24-bus system the surrogate attains R2 = 0.9996 for active generation and 0.0015 p.u. voltage-magnitude RMSE; scalability is confirmed on the IEEE 300-bus system (0.0036 p.u. RMSE, R2 = 0.9841 for voltage magnitude across 299,700 predictions). A three-mode control study further shows that the deadband widens the control-error distribution while leaving total droop compensation unchanged, establishing deadband width as an actionable node-level design feature.

0.29

Graph-Based Dynamic Activity Prediction for Real-Time Power System Applications

eess.SY ·2026-11-03 ·Stefanos Eleftheriadis, Mohammad Hashemnezhad, Savvas Panagi, Thibaut Vermeulen, Petros Aristidou
similarity 0.56
Abstract

Online dynamic security assessment and day-ahead planning require rapid identification of where disturbances will produce significant dynamic activity. Full time-domain simulations are computationally demanding, while existing machine-learning approaches predict system-level outcomes or require post-disturbance trajectories. This paper proposes a pair-aware Graph Isomorphism Network with Edge features (GINE) framework comprising two task-specific models for predicting bus-voltage and generator apparent-power activity from the operating point and contingency description. Physically aware KPI cuts convert simulated responses into ordinal activity targets for model training. Evaluations on Nordic 32 and the French transmission system with more than 6 000 buses show that pair-aware fusion and graph embeddings improve on a local baseline on Nordic 32, with GINE the lower-cost graph encoder, and that the framework remains effective at large scale. As a downstream application, the predicted activity maps guide Adaptive Model Simplification, reducing continuous and discrete model variables by 72% and 66%, achieving speedups of up to 3.16x, and preserving voltage trajectories when critical substations are retained. These results demonstrate scalable, pre-disturbance prediction of component-level dynamic activity.

0.29

Designing Grid-Aware Dynamic Specifications for Large Data Center Loads

eess.SY ·2026-09-16 ·Ashutossh Gupta, Vassilis Kekatos
similarity 0.55
Abstract · 10 pages, 8 figures, IEEE TPWRS

As data center (DC) loads increasingly penetrate the power grid, there is an urgent need for grid operators to provide clear dynamic specifications to DC owners to ensure safe grid operation. To this end, we study two salient behaviors of large language model (LLM) training loads: abrupt ramps at job initiation and termination, which induce transient frequency excursions, and sustained periodic oscillations during training, which result in oscillatory steady-state behavior. For ramping loads, we show that nodal rotor frequencies can be accurately approximated by the center-of-inertia (COI) frequency and derive analytical expressions for its nadir and rate of change of frequency (RoCoF). These expressions determine allowable combinations of ramp times and steady-state load demands satisfying prescribed frequency limits. For oscillatory loads, we derive spectral specifications on their Fourier coefficients and show that the admissible coefficient set can be approximated by a polytope. We further obtain a compact representation via its maximum-volume inscribed ellipsoid, which we show is axis-aligned. Numerical tests on the WECC 179-bus system demonstrate that the resulting specifications remain valid for higher-order nonlinear dynamics. The proposed framework provides actionable specifications for regulating the dynamic behavior of large DC loads and informing load-shaping mechanisms within the data center ecosystem.

0.27

Beyond Accuracy: Physics-Informed Evaluation of ANN-based Power Flow Solvers under System Shift

eess.SY ·2026-11-10 ·Dong Liu, Jochen Stiasny, Jochen Cremer, Pedro P. Vergara
similarity 0.54
Abstract

Recent advances in artificial deep learning-based power flow (PF) solvers have primarily focused on improving estimation accuracy, while their physical feasibility and operational reliability under realistic system variations remain insufficiently evaluated. This paper proposes a physics-informed evaluation framework for deep learning-based PF solvers under topology and load distribution shifts. Beyond conventional voltage-domain errors, the framework incorporates KCL gaps, branch-flow gaps, KVL residuals, continuous feasibility scores, and strict, practical, and relaxed PF feasibility rates. Four case studies are designed to investigate topology shifts, mixed topology training, load distribution shifts, and combined topology distribution shifts. Eight ANN architectures, including graph input models, load-only baselines, and physics-informed neural networks, are evaluated under consistent settings. The results demonstrate that low estimation errors do not necessarily correspond to physically feasible or operationally reliable PF solutions, particularly under combined system shifts. The proposed framework establishes an initial foundation and analysis for the development and verification of trustworthy deep learning-based PF solvers, providing support for their reliable deployment in future AI-enabled power system analysis.

0.09