CS Paper Radar

Intelligent Fault and Lightning Detection Algorithm for VSC-MTDC grids based on ResNet with Hybrid Attention Mechanism

Yunqi Zhang

eess.SY ·submitted 2026-09-08 16:38 UTC · v1
unusual

Abstract

To address the existing challenges in fault detection for voltage source converter-based multi-terminal DC (VSC-MTDC) grids, this paper proposes an intelligent fault and lightning detection algorithm based on S transform and Residual Network with hybrid attention mechanism (RWHAM).The DC line double-ended initial current traveling waves (ICTWs) are first converted into time-frequency matrices by performing S transform and then visualized as a two-dimensional image. The image effectively characterizes the time-frequency features of ICTWs under different fault and lightning conditions, making it easier to extract critical features for the models. Next, the RWHAM model is constructed and the images are fed into the model to detect internal and external faults and lightning interference. The weight of the key information in the image is increased by hybrid attention mechanism, which in turn improves the fault detection ability of the RWHAM model. Extensive simulations involving 21,620 distinct cases on PSCAD/EMTDC validate the algorithm's high accuracy and rapid response across different types of faults and lightning interference. Furthermore, it exhibits excellent generalization ability when the parameters of VSC-MTDC grids change.

Closest papers

Nearest neighbours by meaning across the whole index.

Foundation Models Meet Power Grid Topology for Cascade Prediction

eess.SY ·2026-10-23 ·Soumav Biswas, Mia Naeini
similarity 0.52
Abstract · 10 pages

Accurate early-stage prediction of cascading failure severity is essential for assessing the vulnerability of power transmission networks. However, existing data-driven approaches often rely on network-specific representations, limiting their generalizability across power system topologies. This work investigates the complementary capabilities of Large Language Models (LLMs) and Graph Neural Networks (GNNs) for cascading failure severity prediction. First, standalone LLM predictors are developed using a LoRA-fine-tuned LLaMA-3-8B-Instruct model with varying degrees of topological information. A hybrid Graph-LLM fusion framework is then proposed, integrating a Topology-Aware Graph Attention Transformer (TAGAT) with the LLM through confidence-gated fusion. TAGAT captures structural dependencies among transmission lines, while the LLM extracts representations from early-stage power-flow observations and aggregated cascade descriptors. The frameworks are evaluated on 30,000 simulated cascading failure scenarios for each of the IEEE 118-bus and IEEE 300-bus systems. Using only the first four cascade steps, the hybrid framework achieves weighted F1 scores of 0.94 and 0.92, respectively. In cross-system transfer from IEEE 118-bus to IEEE 300-bus, it achieves 0.72 zero-shot accuracy, improving to 0.83 with limited target-system calibration, outperforming standalone models and conventional baselines. These results show the potential of combining graph-based structural learning with foundation models to improve cascading failure severity prediction and cross-system transferability.

0.24

A Systematic Evaluation of Machine Learning Methods for Fault Detection and Line Identification in Electrical Power Grids

cs.LG eess.SP ·2026-09-15 ·Julian Oelhaf, Georg Kordowich, Paula Andrea Pérez-Toro, Tomás Arias-Vergara, Andreas Maier +2 more
publishedhighly cited similarity 0.52
Abstract · Accepted at ICASSP 2025. 5 pages, 4 figures. Published version: DOI 10.1109/ICASSP49660.2025.10890544

The integration of renewable energy sources into the electrical grid introduces complex challenges in fault detection and coordination of grid recovery mechanisms. Traditional relay protection systems, which operate based on static rules and predefined thresholds, are inadequate for addressing these challenges, particularly in detecting and isolating faults such as short circuits. Consequently, the conventional methodologies applied to electrical network protection frequently fail to achieve optimal performance in fault detection, especially in terms of adherence to safety standards and the selective limitation of damage. Recent research indicates that machine learning (ML)-based approaches can effectively tackle these issues; however, variations in grid configurations and analysis windows have impeded consistent comparative assessments. In this study, we assess the efficacy of various ML models in detecting electrical faults and pinpointing defective transmission lines within a 10 ms measurement interval - a critical time-frame for real-time operational viability, for the first time. The most effective model attained an F1 score of 0.991 +/- 0.018 and demonstrated a processing time of 0.342ms +/- 0.509ms.

0.52

Multi-Library Feature Engineering and Statistically Validated Classification for Power Swing Detection and Stability Assessment

eess.SP cs.LG ·2026-11-16 ·Pallav Kumar Bera, Samita Rani Pani, Ranjeeta Patel
published similarity 0.51
Abstract · Accepted at Annual Conference of the IEEE Industrial Electronics Society (IECON) 2026; 52nd Edition; Doha, Qatar

Faults occurring during power swings, and the evolution of a swing into an unstable condition, cause distance-relay maloperation and cascaded outages. This paper identifies faults, faults during power swings, and power swings, and distinguishes stable from unstable swings in a 9-bus WSCC system modeled in PSCAD/EMTDC. Three time-series feature libraries (tsfresh, TSFEL, and tsfeatures) are applied to the 3-phase relay voltages and currents, giving 3286 statistical, temporal, spectral, and fractal descriptors per event window. A two-step feature selection (Boruta all-relevant filtering followed by RFECV- and SHAP-guided minimal-optimal pruning) reduces the feature set to 18 compact, non-redundant features. 14 classifiers spanning linear, kernel/instance-based, probabilistic, neural, and tree-ensemble/boosting families are then benchmarked under repeated stratified cross-validation, with model differences assessed by a Friedman/Nemenyi omnibus-and-post-hoc test and a Nadeau--Bengio corrected paired t-test. Rotation Forest (ROF) identifies the three event types with 99.98% and SVM-RBF distinguishes stable from unstable swings with 97.97% balanced accuracy. The results show that automated, library-driven feature extraction combined with rigorous statistical model comparison achieves near-perfect discrimination while retaining feature-level interpretability through SHAP importance.

0.28

An Accurate Modulation-Assisted Method for Phasor Estimation Under Decaying DC Offsets

eess.SY ·2026-11-10 ·Sina Mohammadi, Apurv Shukla, Junho Hong, Wencong Su
similarity 0.51
Abstract · This work has been submitted to the IEEE TPWRD for possible publication. Copyright may be transferred without notice, after which this versi…

Decaying DC (DDC) offsets severely compromise the accurate estimation of current phasors immediately following power grid fault occurrence. Consequently, conventional full-cycle discrete Fourier transform (FCDFT) algorithms experience decaying oscillatory magnitude errors, potentially causing distance relays to malfunction. This paper introduces a modulation-assisted technique designed to precisely eliminate the DDC components from fault current signals. By multiplying the fault signal with a high-frequency carrier and applying consecutive sliding Fourier projections, the proposed method effectively isolates the DDC signal while entirely rejecting higher-order harmonic interference. It utilizes a direct algebraic solution derived from a robust forward-difference operation across just three sequential projections to estimate and extract the DDC parameters. Furthermore, the algorithm seamlessly processes both single and multiple DDC components by dynamically tracking them as one equivalent first-order mode. Extensive evaluations are conducted to validate the proposed method accuracy. The proposed algorithm limits the maximum overshoot (MO) to 0.62% (0.59% for $k \geq 8$) for the evaluated DDC cases, and to 2.47% (0.95% at 20 dB for $k = 8$) under noisy conditions.

0.19

Deep Learning-Based Detection of Electrical Faults and Power Quality Disturbances in Aerospace Power Systems

eess.SP cs.LGeess.SY ·2026-09-09 ·Ian C. Guzmán, Radu Babiceanu, Berker Peköz
top venuecode/data similarity 0.50
Abstract · Accepted for publication in IEEE Transactions on Aerospace and Electronic Systems. Pending journal reference/external DOI

More Electric Aircraft require fast and reliable monitoring of high-frequency electrical networks, yet most power quality disturbance and fault diagnosis methods are developed for conventional 50 or 60 Hz grids. This work presents a hardware-aware deep learning framework for multiclass detection of electrical faults and power quality disturbances in a 400 Hz aerospace power system. A high-fidelity simulation model inspired by the Boeing 787 electrical architecture generates voltage and current waveforms for 21 normal, disturbance, switching, open-circuit, and short-circuit conditions. Two datasets, each containing 73,500 samples, are formed from one-dimensional time-series signals and short-time Fourier transform time-frequency representations. Signal-processing augmentation, domain randomization, and class-specific generative adversarial networks increase waveform diversity, and the time-series dataset is released through IEEE DataPort. We compare 1D and 2D convolutional neural networks, long short-term memory networks, CNN-LSTM hybrids, ResNet, MobileNet, and VGG models under common training conditions. A compact ResNet provides the best accuracy-complexity tradeoff, achieving 96.94 percent software test accuracy with 175,685 parameters. After 8-bit quantization and deployment on a Xilinx Zynq UltraScale Plus MPSoC ZCU102, the model achieves 95.87 percent accuracy and a measured mean neural-network accelerator latency of 6.90 ms per input record. The results establish simulation-based, accelerator-level feasibility for embedded edge AI in aircraft electrical health monitoring and motivate future end-to-end data acquisition and experimental validation.

0.52

GCN-Based Model for Fault Classification in Distribution Networks under Harmonic Distortion

eess.SP ·2026-09-23 ·Fathima Razeeya Mohamed Razick, Syed Muhammad Ahsan, Petr Musilek
published similarity 0.50
Abstract · Accepted and presented at the IEEE Power and Energy Society General Meeting 2026, Montreal, Canada, July 19-23, 2026

The increasing integration of distributed energy resources introduces new challenges for accurate fault detection and classification in distribution networks. This paper presents a topology-aware graph convolutional network-based model for fault classification under inverter-induced harmonic distortion. The model uses pre-fault and post-fault voltage and current phasors, including harmonic components, mapped to the IEEE 34-bus system topology. The simulation data generated in OpenDSS encompass varying levels of penetration of solar photovoltaics (30%, 50%, 70%) and current total harmonic distortion (0%, 1%, 3%, 5%) across multiple fault types: single line-to-ground, line-to-line, double line-to-ground, and three-phase-to-ground. A differential evolution algorithm is employed to optimize the hyperparameters of the network, resulting in a three-layer model that achieves an F1-score of 0.98. Stress testing across scenarios confirms high robustness and minimal class confusion. The results demonstrate that a graph convolutional network-based model can effectively classify distribution faults under varying photovoltaic penetration levels and harmonically distorted conditions. Comparative analyses with convolutional neural network, long short-term memory, and multi-layer perceptron architectures demonstrate that the proposed model delivers superior classification performance, particularly under the most stressed condition with 70% photovoltaic penetration and 5% harmonic distortion.

0.48

A simulation based dataset of faults and events for machine learning in power systems

eess.SY ·2026-08-20 ·Georg Kordowich, Jonathan Loebel, Julian Oelhaf, Andreas Maier, Siming Bayer +2 more
similarity 0.48
Abstract

The integration of inverter-based renewable energy sources into electric grids challenges conventional power system protection. Machine learning-based solutions can address these challenges by utilizing available data in modern smart grids. However, the lack of open datasets prevents reproducibility and fair comparisons between different approaches and their results, which hinders further progress. Therefore, this paper presents EvEMTBench, a synthetic dataset of faults and events generated using electromagnetic transient simulations. The physical plausibility of the power system simulation is ensured by validating the simulation parameters against established literature and providing comprehensive documentation of the simulation procedure. The dataset is designed for training, fine-tuning, and benchmarking machine learning models by providing synchronized point-on-wave voltage and current measurements at 9600 Hz across a diverse set of topologies and voltage levels. The inclusion of a wide range of fault and operating events allows the utilization of EvEMTBench for different tasks like incipient fault detection, fault localization, or event detection.

0.50

One-Cycle Fault Classification and Faulted-Line Identification on the PROTECT-90 Dataset: An Initial Application Benchmark

eess.SY cs.LG ·2026-10-02 ·Emad Abukhousa, Abdulaziz Qwbaiban, Saman Zonouz, A. P. Sakis Meliopoulos
benchmarkcode/data similarity 0.47
Abstract

Open electromagnetic-transient datasets are beginning to make reproducible learning-based protection studies possible, but the practical use of these datasets still requires application-level benchmarks that define timing, sensing, and validation assumptions. This paper presents an initial application benchmark on the recently released PROTECT-90 dataset for two protection-oriented tasks: fault-type classification and discrete faulted-line identification. A compact one-dimensional convolutional neural network (CNN) is evaluated using post-inception windows of 0.25, 0.5, 1, and 2 cycles under strict episode-wise splitting. A non-convolutional multilayer perceptron (MLP) is also trained as an architecture-control baseline. The results show that both tasks are nearly saturated under full observability, with one-cycle test accuracies of 99.84% for fault type and 100.00% for line identification. The main performance variation appears under reduced observability: current-only inputs preserve line identification accuracy at 100.00%, whereas voltage-only inputs reduce line identification accuracy to 53.09% with the CNN and 50.57% with the MLP. This indicates that the limiting factor is measurement information rather than neural architecture. Additional stratified checks show stable performance across topology states and fault-resistance bins, while CPU inference contributes only 0.528 ms to the one-cycle total decision time of 20.53 ms.

0.29