CS Paper Radar

Exponential Pixelating Integral transform with dual fractal features for enhanced chest X-ray abnormality detection

Naveenraj Kamalakannan, Sri Ram Macharla, M Kanimozhi, M S Sudhakar

eess.IV cs.CV ·submitted 2026-09-10 02:10 UTC · v1
publishedunusual

Abstract

The heightened prevalence of respiratory disorders, particularly exacerbated by a significant upswing in fatalities due to the novel coronavirus, underscores the critical need for early detection and timely intervention. This imperative is paramount, possessing the potential to profoundly impact and safeguard numerous lives. Medically, chest radiography stands out as an essential and economically viable medical imaging approach for diagnosing and assessing the severity of diverse Respiratory Disorders. However, their detection in Chest X-Rays is a cumbersome task even for well-trained radiologists owing to low contrast issues, overlapping of the tissue structures, subjective variability, and the presence of noise. To address these issues, a novel analytical model termed Exponential Pixelating Integral is introduced for the automatic detection of infections in Chest X-Rays in this work. Initially, the presented Exponential Pixelating Integral enhances the pixel intensities to overcome the low-contrast issues that are then polar-transformed followed by their representation using the locally invariant Mandelbrot and Julia fractal geometries for effective distinction of structural features. The collated features labeled Exponential Pixelating Integral with dually characterized fractal features are then classified by the non-parametric multivariate adaptive regression splines to establish an ensemble model between each pair of classes for effective diagnosis of diverse diseases. Rigorous analysis of the proposed classification framework on large medical benchmarked datasets showcases its superiority over its peers by registering a higher classification accuracy and F1 scores ranging from 98.46 to 99.45% and 96.53-98.10% respectively, making it a precise and interpretable automated system for diagnosing respiratory disorders.

Comment
Preprint of the article published in the ELSEVIER journal Computers in Biology and Medicine (CIBM), Vol. 182, November 2024. Final version available at DOI: https://doi.org/10.1016/j.compbiomed.2024.109093
Journal ref
Computers in Biology and Medicine (CIBM), Vol. 182, November 2024, 109093
DOI
10.1016/j.compbiomed.2024.109093

Closest papers

Nearest neighbours by meaning across the whole index.

Pneumonia Detection on Chest X-Rays Derived from a U-Net Segmentation Model

eess.IV ·2026-10-15 ·Manasvini Singh
similarity 0.54
Abstract · 6 pages, 3 figures, 6 tables

Pneumonia killed more than 740,000 children under the age of five in 2019, and it can be difficult to recognize on chest radiographs (CXRs): opacities may be faint in early disease, may sit behind the equally bright heart shadow, and may resemble other lung conditions. Most deep learning systems treat pneumonia detection as a yes-or-no classification task. This paper asks whether a model trained on a harder task, segmenting pneumonia pixel by pixel, can be turned into an effective detector for the simpler task of deciding whether an image contains pneumonia at all. The hypothesis is that the detailed supervision of segmentation forces the network to learn where and what the disease looks like, producing a better detector than training for detection alone. A U-Net was trained to segment pneumonia on the RSNA Pneumonia Detection Challenge dataset of 26,684 radiographs, whose rectangular bounding boxes were converted into pixel masks. The data are heavily imbalanced: 22.5% of images are positive, and only 2.6% of pixels fall inside a box, so focal loss with α = 0.25 and γ = 2 and dropout were needed for the model to learn. On the harder segmentation task, the model reached a pixel-level F1 score of 0.45 on a held-out test set of 2,668 images. Applied to the simpler detection task, the same model reached a precision of 0.71, recall of 0.52, and F1 score of 0.60, with 91% specificity, and consistent scores on the development set. These results show that a segmentation-trained model transfers to detection while also showing where the suspected disease is. A direct comparison with a classifier trained only for detection on the same data is needed to confirm whether the segmentation-first approach is better, and is the main direction for future work.

0.18

XFlow: A Workflow Model for Instruction-Guided Lesion Segmentation in Chest X-rays

cs.CV ·2026-09-28 ·Geon Choi, Hangyul Yoon, Hyunki Park, Sang Hoon Seo, Edward Choi
code/data similarity 0.53
Abstract

Existing text-guided segmentation models in the medical domain cover only a narrow set of anatomical structures and lesions in chest X-rays (CXRs), and most of them assume that the queried target is always present in the image. Instruction-guided lesion segmentation (ILS) was introduced to overcome these limitations by segmenting diverse lesion types from simple user instructions while also recognizing when the queried lesion is absent, and ROSALIA was proposed as the first model for this task. However, the masks produced by ROSALIA remain of limited quality, often carrying scattered noise. Moreover, ROSALIA predicts the mask in a single shot, which differs fundamentally from how radiologists perceive and delineate lesions in practice. A radiologist first surveys the entire thorax, then localizes the approximate region of abnormality, and only then refines the lesion contour. Motivated by this coarse-to-fine, multi-level perception process, we present XFlow, a workflow model for ILS that combines box-based localization with multi-turn point refinement. XFlow detects the lungs, decides whether the queried finding is present in each of them, and prompts a fine-tuned SAM with the lesion box for an initial mask. It then corrects that mask through point prompts until its boundary follows the lesion, leaving every intermediate decision visible. Our experiments show that XFlow achieves the best segmentation quality on both internal and external evaluation. Notably, it surpasses ROSALIA in segmentation quality even when the two are trained on the same lesion annotations. Code and model weights will be made publicly available.

0.55

DeBoneDiT: Depth-Driven Conditional Bridge Diffusion Transformers for Bone Suppression in Chest X-Ray Images

cs.CV ·2026-10-14 ·Yifei Sun, Fenglei Fan, Junhao Jia, Wenming Deng, Hongxia Xu +2 more
benchmark similarity 0.51
Abstract · 19 pages, 13 figures

Chest X-Ray (CXR) is a primary modality for diagnosing pulmonary diseases, yet the overlap of bony structures often obscures critical radiographic findings, increasing the risk of diagnostic uncertainty. While Dual-Energy Subtraction (DES) is the clinical benchmark for bone suppression, its widespread adoption is primarily hindered by specialized hardware requirements and increased radiation exposure. Recently, diffusion-based generative models have shown promise for this task, yet they are still constrained by reconstruction-biased latent compression, prior-induced domain gap, and a scarcity of high-quality paired datasets. To address these challenges, we propose DeBoneDiT, a depth-driven conditional bridge diffusion Transformer architecture for efficient high-resolution bone suppression. We first introduce Depth Auto-Encoder (DAE), a structure-aware vision tokenizer for latent compression. By incorporating a multi-level depth feature loss derived from the pretrained Depth Anything V2 encoder, DAE preserves both visual fidelity and structural consistency. Second, we formulate bone suppression as a source-conditioned Brownian bridge diffusion process, leveraging CXRs as both the diffusion prior and structural guidance to narrow the source-to-target domain gap and maintain anatomical plausibility. Furthermore, we have constructed and released SZCH-X-Rays, the largest publicly available high-quality paired dataset for bone suppression to date, comprising 741 pairs of CXR and DES soft tissue images. Extensive experiments and downstream evaluation demonstrate that DeBoneDiT achieves superior bone suppression performance with reduced computational overhead.

0.19

Toward Vision Language Model-based Assessment of Clinical Quality and Usability of LGE-MR Images for Cardiac Ablation Planning

eess.IV cs.CV ·2026-08-21 ·Bipasha Kundu, Abhishek Chaturvedi, Axel W. E. Wismueller, Richard Simon, Cristian A. Linte
benchmark similarity 0.51
Abstract

LGE cardiac MRI is widely used for left atrial fibrosis assessment and ablation planning in atrial fibrillation patients as knowledge of fibrotic tissue regions identified from LGE-MRI is critical for catheter ablation. Often, poor quality images used during ablation planning can cause mis-localization of ablation targets, directly impacting procedure safety and outcome. The decision of whether a scan meets the minimum quality threshold for ablation planning is currently made informally by the reviewing radiologist and is not captured by any automated system, yet it is arguably the most safety-critical output of the image quality assessment (IQA) process. However, variations in image quality caused by noise, motion artifacts, and poor boundary definition significantly compromise the reliability of downstream segmentation and clinical decision-making tasks. Manual quality assessment by expert radiologists is subjective and difficult to scale, while existing automated methods produce scalar scores without interpretable clinical reasoning. In this work, we propose a two-stage vision language model (VLM) framework for clinically grounded image quality assessment of left atrial LGE-MRI. In the first stage, a fine-tuned VLM generates structured radiology-style quality reports predicting five radiologist-defined criteria: Noise, Motion Artifact, LA Boundary Accuracy, PV Region Accuracy, and Under-segmentation Severity. In the second stage, a GPT-based reasoning module maps the predicted quality and reports to a structured quality scores and binary clinical usability decision for ablation planning. We curate a dataset of 60 annotated image slice-text pairs from 20 patients and benchmark four state-of-the-art VLM architectures. InternVL2 achieves the highest criterion-level accuracy (Avg ACC=0.65, PLCC=0.79), while DeepSeek achieves perfect clinical usability agreement (Acc=1.00, kappa=1.00).

0.27

Shape-guided Gaussian Splatting for Sparse-View X-ray 3D Reconstruction

cs.CV ·2026-09-09 ·Pranav Poudel, Florence Dell'Aniello Picard, Nairouz Shehata, Frédéric Lavoie, Herve Lombaert
publishedcode/data similarity 0.51
Abstract · Accepted at: Off-Grid: 1st Workshop on Continuous Representations and Grid-Free Methods in Medical Imaging, MICCAI 2026

Sparse-view X-ray 3D reconstruction is essential for reducing radiation exposure, but recovering a density field from a handful of X-ray projections is severely ill-posed. Recently, 3D Gaussian Splatting has achieved state-of-the-art performance in sparse-view reconstruction by representing the volume using explicit, optimized primitives, but it requires dozens of projected views. With fewer views, reconstruction quality degrades severely since the explicit primitives are optimized freely without any anatomical information. Anatomical structures, in contrast, share similar geometry and density across a population. Their variations are bounded within a limited range that statistical shape models can capture. This paper proposes a shape-guided Gaussian splatting framework for sparse-view X-ray 3D reconstructions. Our contribution lies in driving Gaussian positions toward anatomically valid configurations, alongside atlas-based density regularization. Our method ensures anatomically consistent reconstruction and improves PSNR by 2.83 dB over a state-of-the-art Gaussian splatting baseline with as few as 5 views. Code Available: https://github.com/polyshape-lab/ShapeGuidedGaussian

0.46

MedGSSR: Generalizable Medical Image Super-Resolution 3D Reconstruction via Hierarchical Feed-forward Gaussian Splatting

eess.IV cs.CEcs.CVq-bio.QM ·2026-09-06 ·Chengkai Wang, Luoyu Hong, Yiting Zhao, Jiamin Wang, Xiang Feng +5 more
top venue similarity 0.50
Abstract · ECCV 2026

High-resolution volumetric medical imaging is critical for clinical diagnosis, yet acquisition is often limited by scanner hardware, scan time, and for CT, radiation dose. Medical 3D Super-Resolution (Med3DSR) offers a computational alternative, but existing methods commonly rely on per-subject optimization, pretrained priors, or coordinate-based implicit representations, which compromise anatomical fidelity and limit efficiency. To address these limitations, we present MedGSSR, a fully end-to-end feed-forward framework that represents volumes as an explicit 3D Gaussian field for Med3DSR. Unlike coordinate-based implicit functions, our explicit 3D Gaussian representation naturally enhances signal continuity and local high-frequency fidelity. Specifically, MedGSSR explicitly decouples the reconstruction process into coarse-grained structural preservation and fine-grained textural refinement through the proposed Pyramid Anatomical Encoder and a Hierarchical Gaussian Projector. To support arbitrary-scale super-resolution, we introduce sub-voxel Gaussian decomposition and a Differentiable Gaussian Voxelizer that directly queries the continuous 3D intensity field, reducing discretization artifacts. Extensive experiments on MRI and CT benchmarks demonstrate that MedGSSR significantly outperforms state-of-the-art methods. Notably, our framework exhibits robust generalizability across unseen datasets without requiring per-subject optimization, enabling fast inference and high-fidelity volumetric super-resolution in practical clinical settings. Our project webpage, including code, is at https://william2ai.github.io/medgssr

0.66

A BEMD-Based Quaternion Filtering Approach Sharp-to-Soft Kernel CT Image Conversion

cs.CV ·2026-10-05 ·Mahmoud Nasr, Jan K. Argasinski, Krzysztof Brzostowski, Adam Piorkowski
publishedunusual similarity 0.50
Abstract

The quality of computed tomography (CT) images is significantly affected by the selection of reconstruction kernels: sharp kernels improve spatial resolution but increase noise, whereas soft kernels diminish noise at the expense of edge clarity. This study presents an innovative enhancement framework utilising Bidimensional Empirical Mode Decomposition in conjunction with Quaternion Bilateral Filtering (BEMD--QBF) to convert sharp-kernel CT images into representations resembling soft-kernels, while maintaining critical anatomical structures. The technique disaggregates each image into intrinsic mode functions via BEMD and analyzes them inside a cohesive quaternion framework to attain efficient noise reduction and structural integrity. The proposed methodology is evaluated using several reconstruction kernels (B50, B46, B41, B36, B35, B31) and compared with recognised filtering strategies, including Non-Local Means, Anisotropic Diffusion, Bilateral Filtering, and Quaternion Bilateral Filtering. Quantitative evaluations of the Structural Similarity Index (SSIM) and Peak Signal-to-Noise Ratio (PSNR) indicate that BEMD-QBF consistently attains superior structural fidelity and competitive noise reduction across all evaluated kernels. The results underscore the efficacy of the proposed strategy as a viable approach to enhancing post-reconstruction CT images, yielding superior image quality without requiring access to raw projection data.

0.40

GRIPNet: Gaussian Radial Intensity Prior Guided Architecture for Pulmonary Nodule Detection in CT

cs.CV cs.AI ·2026-09-10 ·Haojie Yang, Ran Su
similarity 0.50
Abstract

Lung cancer causes more deaths than any other malignancy, and low-dose CT screening is the main pathway to early diagnosis. That pathway hinges on the smallest lesions, yet nodules below six millimeters remain hard to detect, because most methods treat a nodule as a generic object and ignore the imaging physics behind its appearance. We show that this appearance is highly regular. Intensity peaks at the geometric center of a nodule and decays radially in a Gaussian pattern, and a fit to 18,218 annotated lesions from three public benchmarks yields a mean radial coefficient of determination above 0.86 in every dataset and size stratum. A square convolution samples both axes uniformly and is mismatched to this radial signal, most severely for small nodules. Guided by this evidence, we propose GRIPNet (Gaussian Radial Intensity Prior Network), a detector in which every module maps to a measurable property of the intensity distribution. Pinwheel convolutions decompose radial gradients, a dual-frequency module separates boundary detail from structural context, dilated masked attention matches the decay extent, and an adaptive loss reweights samples by conspicuity. GRIPNet raises mAP@0.5 to 95.3, 91.6 and 97.9 percent on KanserSet, LUNA16 and Lung-PET-CT-Dx while sharpening high-IoU localization at real-time speed.

0.12