CS Paper Radar

Task-Based CT Protocol Optimization Using Reinforcement Learning and Virtual Imaging Trials

Jiaqi Zou, David Fenwick, Vahid Tarokh, Nicholas Felice, Jayasai Rajagopal, Anuj Kapadia, Ehsan Samei, Navid NaderiAlizadeh, Ehsan Abadi

cs.CV cs.AIcs.LG ·submitted 2026-09-10 15:00 UTC · v1
hot direction

Abstract

Protocol optimization in computed tomography (CT) aims to improve diagnostic image quality while reducing radiation dose, but the interdependence of acquisition and reconstruction parameters makes exhaustive testing impractical. We propose a virtual imaging trial framework with reinforcement learning for efficient CT protocol optimization. Sixty-three computational human models with liver lesions were imaged using a validated CT simulator across 468 combinations of acquisition and reconstruction parameters, including tube voltage, tube current, reconstruction kernel, slice thickness, and pixel size. The optimization objective balanced liver lesion detectability, quantified by detectability index d-prime, against radiation dose. A Proximal Policy Optimization agent was trained and conditioned on patient-specific CT localizer embeddings derived from a pretrained vision transformer. On held-out patients, evaluating only 8 protocols per patient, about 2% of exhaustive testing, recovered 98.2% of the exhaustive-search oracle objective. With no patient-specific simulation, surrogate scoring alone achieved 89.7% recovery. Conditioning on the localizer improved zero-simulation recovery by 10.7 percentage points over the localizer-blind policy (paired 95% CI 2.9-19.5; p=0.02). These results show that the proposed framework can substantially reduce exhaustive protocol testing while enabling task-based, dose-aware protocol selection before the diagnostic scan.

Comment
11 pages, 7 figures, 4 tables

Closest papers

Nearest neighbours by meaning across the whole index.

LeCor: Learning to Be Corrected by Meta-Learned Test-Time Training for Interactive 3D Lung-Tumour Segmentation

cs.CV cs.LG ·2026-09-08 ·Yi Luo, Yike Guo, Wenxuan Li, Zongwei Zhou, Rui Zhang +1 more
similarity 0.60
Abstract · 18 pages, 4 figures

Delineating lung tumours on computed tomography (CT) takes a considerable share of the time spent on radiotherapy planning, and a contour proposed by a model can be refined interactively by the clinician. Promptable foundation models such as SAM 3 support this workflow by writing each correction into a session memory that conditions the remaining slices, while the model weights stay fixed. On 690 test cases from five public CT cohorts, fine-tuning SAM 3 on lung tumours raises the Dice obtained from a single point prompt from 0.298 to 0.757, and seven rounds of corrections raise it further to 0.765, but under memory conditioning alone the accuracy on slices the annotator has not touched stops improving after six rounds. We therefore treat each correction as a training signal and propose LeCor, which performs test-time training on a small set of case adapters that are reset for every case and meta-learned such that a single gradient step driven by a click improves the slices that were not clicked. On the 133 test cases that span at least eight slices, LeCor raises the Dice reached after seven correction rounds from 0.787 with the fine-tuned model to 0.827, reduces the number of cases that never reach a Dice of 0.80 from 47 to 27, and reaches in three correction rounds the accuracy that the fine-tuned model attains in seven.

0.21

Agentic AI Reasoning and Learned Sampling for Task-Aware Projection Selection in Sparse-View CT: Predicting Hemodynamics

cs.AI physics.flu-dyn ·2026-10-28 ·Mahmoud Elhadidy, Roshan M. D'Souza, Amirhossein Arzani
similarity 0.60
Abstract

Sparse-view computed tomography (CT) reduces the number of acquired projections, but conventional sampling strategies are designed primarily for image reconstruction rather than for downstream physical inference. Here, we investigate optimal task-aware projection selection for directly predicting hemodynamics from sparse CT angiography (CTA) measurements. Using computational fluid dynamics simulations of intracranial aneurysms, we generate synthetic fan-beam CTA projections and train a Fourier neural operator (FNO) to predict two targets: the spatially resolved time-averaged wall shear stress (TAWSS) field and the spatially averaged TAWSS. The FNO was coupled with optimal input selection for simultaneous optimal sampling and training. Our goal was to investigate if agentic AI could discover optimal sampling strategies that outperform current methods. We compared fixed uniform and golden-angle sampling with three task-aware optimal selection strategies: Gumbel-Softmax, a Soft top-K method, and an agentic AI selector. The methods were compared at different view selection budgets. A detailed analysis of the AI agent was performed to understand its reasoning and performance. For spatially resolved TAWSS, Agentic and Soft top-K achieve the lowest mean errors (Agentic performs slightly better) and substantially outperform fixed sampling under extreme sparsity. For spatially averaged TAWSS, optimized selection becomes important at extremely sparse acquisitions. Analysis of the selected masks reveals multiple distinct subsets concentrated around informative regions. Moreover, masks optimized for hemodynamic prediction yield poor image reconstructions, showing that task-optimal acquisition differs fundamentally from reconstruction-optimal acquisition. This work suggests the possibility of designing sparse acquisitions directly around downstream physical quantities.

0.27

AgentCT: A Vision-Language Agent for Universal CT Imaging

cs.CV ·2026-11-08 ·Zhihao Chen, Qi Gao, Chuang Niu, Qiegen Liu, Yi Zhang +1 more
code/datahot direction similarity 0.59
Abstract · 14 pages, 5 figures

Computed tomography (CT) restoration methods often use a single network for low-dose CT (LDCT), sparse-view CT (SVCT), and metal artifact reduction (MAR), despite the distinct physics of these degradations. We propose AgentCT, a vision-language agent that identifies the degradation and routes images to task-specific restoration models. A LoRA-adapted Qwen3-VL-4B controller predicts degradation type and severity, selects a specialist, and reassesses the restored image. The LDCT specialist uses an image-domain diffusion model, whereas the SVCT and MAR specialists combine projection-domain correction, data consistency, differentiable filtered back-projection, and image refinement. We evaluated the controller and specialists separately on patient-disjoint Mayo 2020 abdominal CT data across three severity levels for each degradation. The controller achieved 95.7% accuracy for degradation type and 93.9% for severity, with a 100% JSON parse rate. Using ground-truth degradation labels for routing, AgentCT achieved an overall PSNR/SSIM of 46.18 dB/0.984, compared with 44.93 dB/0.976 for AMIR and 44.29 dB/0.979 for TAMP, and attained the highest PSNR in all nine settings. For SVCT, its dual-domain specialist achieved 46.04 dB with 4.2 million parameters, compared with 44.43 dB for single-task AMIR and 43.57 dB for all-in-one AMIR with 23.5 million parameters. These results support degradation-specific CT restoration with controller-based model selection; evaluation under automatic routing and on independent clinical data remains necessary. Code is available at https://github.com/hao1635/AgentCT.

0.38

BioMed-Agent-RL: A Meta Learning, All You Need for Biomedical Applications

cs.LG cs.AIcs.CV ·2026-08-22 ·Md Asaduzzaman Jabin, Zihao Wu, Tianming Liu
hot direction similarity 0.59
Abstract

The current progress of Clinical Vision Large Language Models (C-VLLMs) has substantially improved digital diagnostics, still these frameworks often endure lesion noises, modality misalignment, hallucination, and missed contextual grounding in complex clinical cases. Moreover, prevailing agent systems usually depend on static and non-adaptable pipelines and lack the versatility necessary for complex medical reasoning. To resolve these difficulties, we present BioMed-Agent-RL, a unified medical agent that incorporates adaptive orchestration, policy, and reward-based reinforcement learning (RL) models for biomedical applications. To ensure reliability, it invokes clinical context-aware preference optimization (CPO), direct preference optimization (DPO), and group relative policy optimization (GRPO) with dynamic entropy regulation. This pipeline utilizes a multimodal meta-learning approach that operates as a field-specific expert and human judgment synthesizer. The agent adaptively utilizes a set of model-level expertise, such as clinical grounding and reasoner, lesion segmenter, and field-specific synthesizer, across various clinical modalities (e.g., X-ray) by utilizing an iterative and adaptive RL approach. The agent learns to seriously synthesize misleading, conflicting vision cues and trust in inherent reasoning, while specialist advice is faulty. An intensive ablation study is conducted across multiple benchmarks, and the agent significantly outperforms existing state of the art models, such as GPT-5, attaining up to ~73% accuracy (gain of ~5%) over contemporary baselines. As a result, the framework suggests a new standard for building factual, reliable, robust, and expert-like intelligent agent systems for independent clinical reasoning.

0.23

Reinforcing intra-operative tumour localisation with weak supervision from pre-operative appearances

cs.CV ·2026-10-22 ·Sidhart Sami, Ali Sharjeel, Sri Atluri, Miao Zhao, Caroline Roney +2 more
similarity 0.59
Abstract

Limited tumour visibility on intra-operative images complicates surgical navigation, including liver hepatocellular carcinoma (HCC) targeting on computed tomography (CT) imaging. This makes labelled datasets difficult to curate for deep learning, and transferring pre-operative delineations through registration remains challenging due to intra-operative deformation and lack of paired pre- and intra-operative data. We propose to transfer tumour appearances learned from pre-operative magnetic resonance (MR) images to guide localisation on intra-operative CT through weak supervision. A classifier is trained to classify tumour presence on pre-operative images. This is applied to windows on intra-operative images, and despite the domain gap, it assigns higher tumour-presence probabilities on average to tumour-containing windows. These weak cross-domain signals guide a reinforcement learning agent to localise tumours on intra-operative images. We compare direct transfer, few-shot adaptation and synthetic transfer (trained using unpaired MR and CT), which translates CT into synthetic MR before localisation. On an external HCC cohort, synthetic transfer outperformed other tested methods and CT-only baselines. Our framework enables cross-modality tumour localisation without paired MR-CT training images.

0.22

Transformer-Based Reinforcement Learning for Phase I Dose Allocation

cs.LG stat.MLstat.AP ·2026-10-30 ·Shijie Yuan
similarity 0.59
Abstract

Phase I dose-finding trials must learn from sparse toxicity observations while limiting exposure to overly toxic doses. We develop a single reinforcement-learning policy for trials with different numbers of ordered dose levels. Each dose is represented as a token containing its normalized position, accumulated patient count, observed dose-limiting toxicities (DLTs), and current-dose indicator. A Transformer encoder summarizes the dose tokens, trial-conditioned cross-attention produces a fixed-dimensional trial representation, and a three-action policy chooses de-escalation, staying, or escalation. The final maximum tolerated dose (MTD) decision is deliberately kept outside the learned policy: after the planned sample size, weighted isotonic regression and a prespecified safety cap select the dose closest to the target toxicity probability. In the simulations, toxicity-penalized policies reduce DLT burden while unpenalized policies improve selection accuracy at the cost of greater toxicity. These results demonstrate a controllable safety--accuracy trade-off but do not establish superiority over conventional dose-finding designs.

0.16

Interactive Whole Slide Images for RL-based Tumour Segmentation

cs.CV ·2026-08-17 ·Mohamad Mohamad, Francesco Ponzio, Maxime Gassier, Nicolas Pote, Xavier Descombes
similarity 0.58
Abstract

Whole-slide image (WSI) analysis remains computationally challenging due to the extremely large spatial resolution of slides and the sparse distribution of tumour regions. We propose an end-to-end reinforcement learning framework for sequential tumour segmentation directly on WSIs. Instead of treating the slide as a predefined collection of candidate patches, we formulate the WSI itself as a hierarchical multi-resolution environment through which an agent navigates using movement, zooming, and tumour selection actions. The agent jointly processes local observations and a global thumbnail representation within an actor-critic architecture trained using proximal policy optimization (PPO). Experiments on pulmonary adenocarcinoma WSIs demonstrate the feasibility of direct sequential tumour segmentation on full slides, achieving comparable coarse segmentation quality relative to patch-based approaches operating at similar magnification levels, while reducing inference time to a few seconds per slide. We further analyse the impact of environment design and action-space granularity. Our results suggest that modelling WSIs as interactive environments provides a promising direction for RL-based computational pathology

0.12

VoxelSage: Tool-Augmented 3D CT Analysis and Simulator-Shielded Sequential Resection Planning for Liver Tumors

cs.CV eess.IV ·2026-09-29 ·Binghong Qian, Xuanhe Liu, Yifan Xing, Wenjie Deng, Jian Wu +1 more
code/data similarity 0.58
Abstract · 21 pages, 10 figures. Technical report. Code at https://github.com/ZJUMAI/VoxelSage

Preoperative liver-tumor assessment requires segmentation, physical-space measurement, visual evidence, and resection planning from the same three-dimensional CT volume. Existing tools often handle these steps separately, while language models cannot reliably compute physical measurements from CT. To provide an integrated workflow, we present VoxelSage, a multi-modal system for two- and three-dimensional visualization, liver-tumor analysis, and preoperative resection planning. Its dual-port architecture separates language-model orchestration from image computation: Port A interprets requests and selects skills, while Port B applies them to CT volumes and segmentation masks and returns structured results. Keeping physical measurements in Port B prevents the LLM from computing them directly and reduces the risk of fabricated numerical results. Eight built-in skills support quantitative analysis, visual evidence generation, three-dimensional reconstruction, segmentation refinement, and sequential resection planning; user-defined skills can extend these functions. For sequence planning, a behavior-cloned neural ranker orders candidate resection targets, while a simulator-based shield checks them against predefined constraints. Across 256 unseen simulator scenes, this approach reduced mean simulated time from 34.274 to 33.388 min (0.886 min, 2.59%) and mean simulated blood loss from 300.847 to 183.852 mL (116.995 mL, 38.89%) relative to a deterministic baseline. These results demonstrate system integration and simulator-level performance, not clinical efficacy or safety. The public implementation is available at https://github.com/ZJUMAI/VoxelSage.

0.29