CS Paper Radar

Low-Ripple Modulation Strategy for a Photovoltaic-Based Triple-Port Hydrogen Production System

Shiqi Zhang, Ziang Jiao, Jiaxin Su, Ning Wang, Zheng Li, Xiaoqiang Guo, Changchun Hua

eess.SY ·submitted 2026-09-12 06:31 UTC · v1
top venue

Abstract

Among various production methods, hydrogen generation via electrolysis powered by renewable energy plays a key role in achieving large-scale green hydrogen production. The triple active bridge isolated DC-DC conversion system exhibits significant application potential in hydrogen production due to its advantages, such as high energy density, wide step-down ratio, and high reliability. However, the output current ripple at the hydrogen production port critically affects the efficiency of the electrolyzer and the hydrogen production rate. Existing studies have limited optimization effects on current ripple and struggle to achieve dynamic optimization, leading to constrained ripple suppression under dynamic operating conditions. To address this issue, this paper proposes a low-ripple modulation strategy based on coordinated optimization of inner and outer phase-shift angles for multi-port power conversion systems in renewable energy hydrogen production. By establishing an accurate mathematical model, the optimal phase-shift angle combination under minimal current ripple conditions is derived. An improved differential evolution algorithm with adaptive parameter strategy is employed to achieve global optimization under dynamic conditions. Simulation and experimental results demonstrate that the proposed strategy effectively suppresses current ripple, providing an efficient and reliable solution for hydrogen production from fluctuating renewable energy sources.

Comment
13 pages. Accepted manuscript
DOI
10.1109/TIE.2025.3639816

Closest papers

Nearest neighbours by meaning across the whole index.

Beyond Higher-Pulse Rectification: Operational Harmonic Coordination in Renewable P2H Systems

eess.SY math.OC ·2026-09-03 ·Yangjun Zeng, Yiwei Qiu, Jie Zhu, Yi Zhou, Tao Wu +4 more
similarity 0.58
Abstract

Thyristor rectifiers (TRs) are cost-effective electrolysis power supplies for renewable power-to-hydrogen (ReP2H) systems, but their harmonics may violate grid-code limits. In contrast to conventional solutions that rely on higher-pulse (such as 24-pulse) rectifiers, this paper proposes an operational harmonic coordination scheme that enables low-cost 12-pulse TRs to meet harmonic requirements through coordinated operation. First, a harmonic model quantifies the effects of rectifier transformer (RCT) tap positions and electrolytic currents, enabling harmonic cancellation among multiple electrolyzers (ELZs). A two-layer framework then coordinates hydrogen production and harmonic mitigation. Hourly scheduling determines ELZ commitment within the harmonic feasible region under renewable uncertainty using stochastic programming and a modified progressive hedging algorithm, while minute-level dispatch tracks renewable power and mitigates harmonics. A decomposition algorithm separates production dispatch from harmonic mitigation to improve computational efficiency. Case studies based on real-life projects show that the proposed method increases profit by 31% over current-only regulation. Annual simulations further show that coordinated 12-pulse TRs can replace 24-pulse rectifiers for harmonic compliance by exchanging additional RCT tap actions for lower transformer investment, reducing rectification-stage cost by 37.5%.

0.21

Fault Diagnosis and Fault-Tolerant Operation Strategy for Triple-Port Hydrogen Production System

eess.SY ·2026-11-14 ·Shiqi Zhang, Yiyina Teng, Yuhang Sun, Fanqin Ding, Ning Wang +2 more
top venueunusualhighly cited similarity 0.53
Abstract · 10 pages, 21 figures

The multi-port converter offers significant advantages in sustainable energy-based hydrogen production, such as high energy density and wide application potential. As the core energy hub in these systems, the multi-port hydrogen converter demands high reliability. However, its numerous switches and complex operation increase the risk of failure. Currently, there are no effective fault diagnosis or fault tolerance solutions for these systems. Current fault diagnosis methods for two-port and multi-port converters rely on many sensors, have low accuracy, and cannot handle multi-switch faults. Additionally, existing fault tolerance strategies fall short in maintaining stable power for the electrolyzer and do not allow capacity sharing among ports. This paper proposes a fault diagnosis method for open-circuit faults in a triple-port hydrogen converter and a corresponding fault-tolerant operating strategy. By optimizing a random forest algorithm with a sparrow search algorithm, high-precision multi-switch fault diagnosis is achieved using only three current sensors. Fault-tolerant operation of the system is achieved through an auxiliary switch after a failure. Additionally, power sharing between output ports can be realized. This ensures the efficient and stable operation of the hydrogen production system. The effectiveness of this solution has been validated through simulations and experiments.

0.64

Constrained Grid-Forming Control for Photovoltaic Systems: A Control Barrier Function Approach

eess.SY ·2026-10-13 ·Amir Afshari, Dominic Groß
similarity 0.53
Abstract

This paper leverages control barrier functions (CBFs) to systematically account for constraints of voltage source converters (VSCs) and photovoltaic (PV) resources in grid-forming (GFM) control. The proposed control combines (unconstrained) dual-port GFM control with control barrier functions (CBFs) to ensure reliable and safe operation of a GFM PV system under grid faults, sudden changes in irradiance, and load perturbations. First, CBFs are used to encode physical and operational limits of the PV system, namely current and voltage limits at its ac and dc terminals. Then, CBFs are used to restrict the dynamics of dual-port GFM control to within the VSC and PV limits during both transient and steady states. To this end, a cost function is defined that encodes trade-offs between forming the ac voltage phase angle/frequency and voltage magnitude under constraints. Then, real-time optimization is used to make the least modification, as measured by the cost function, to the (unconstrained) dual-port GFM control state to remain within the safe set encoded by the CBFs. Finally, the performance of the developed constrained GFM control is evaluated through EMT simulations in MATLAB/Simulink.

0.28

Optimal Dispatch of a Hydrogen-Colocated Renewable-Powered Desalination Plant

eess.SY ·2026-09-09 ·Guochen Zhao, Ahmed S. Alahmed
similarity 0.50
Abstract

This paper develops an analytical framework for profit-maximizing dispatch of water, electricity, and green hydrogen in a renewable-powered water desalination plant (WDP) combining thermal and reverse osmosis (RO) desalination. The optimal dispatch reveals that the schedules of the desalination units, electrolyzer, and grid interaction can all be characterized in closed form as functions of renewable generation. At low renewable output, the plant relies on thermal desalination and grid power while maintaining RO desalination and hydrogen production at their minimum setpoints. At high output, it reduces thermal desalination, increases RO desalination, and allocates surplus power and water to hydrogen production. For renewable output within a precomputed intermediate range, the WDP balances energy internally, allocating resources based on the relative marginal values of hydrogen and RO water. Simulations using real solar and plant data show that integrating RO and thermal desalination with renewable generation and hydrogen production achieves the highest daily profit of 75.945 k$, exceeding the best configuration without hydrogen by 15.1%.

0.21

Unit-to-Plant Stability Shaping of Multi-Electrolyzer ReP2H Plants via Interface Design and Dispatch

eess.SY math.OC ·2026-08-24 ·Miao Zhang, Yiwei Qiu, Xiaoyu Wang, Linlin Wu, Yi Zhou +3 more
similarity 0.50
Abstract

Alkaline water electrolysis (AWE) units supplied by insulated gate bipolar transistor rectifiers (IGBT-Rs) may experience oscil-lations caused by coupling between rectifier control and electro-lyzer (ELZ) dynamics. Because this risk varies with unit loading and power allocation, production-oriented dispatch may place a multi-ELZ renewable power-to-hydrogen (ReP2H) plant near or exceed its stability boundary. This paper proposes a stability-oriented framework for control design and plant production dis-patch. A three-port admittance model links the ac port, dc link, and electrolysis stack. Unit-level dc-port analysis quantifies the effects of loading, temperature, Buck bandwidth, and dc-link capacitance, while plant-level aggregation evaluates how unit commitment and power allocation affect stability. Results show that higher loading reduces stability, whereas larger dc-link ca-pacitance and higher Buck bandwidth improve it. Under the same plant loading, different power allocations result in different plant-level stability margins, with balanced allocation generally providing a larger margin than concentrated allocation. The plant-level model thus distinguishes the stability margins of ad-missible schedules. Hardware-in-the-loop (HIL) tests validate these trends and the proposed redistribution rule. The resulting operating regions and dispatch rules can be used to screen unit commitment and power allocation decisions in plant production scheduling.

0.23

Hydrogen in Practice: A Global Review of Demonstration Projects from Production to Integration

eess.SY ·2026-11-14 ·Yiyina Teng, Shahab Dehghan, Xiaoqiang Guo, Shiqi Zhang, Yanming Wan +2 more
published similarity 0.49
Abstract · 49 pages, 15 figures

Hydrogen technology has the potential to address various challenges related to integrating low- and zero-carbon energy sources, as well as achieving carbon neutrality. It provides valuable solutions for transitioning to net-zero emission energy systems on a global scale. The implementation of hydrogen production and integration demonstration projects has received significant attention around the world and strong support from governments, highlighting the crucial role of such initiatives in the advancement of hydrogen energy. However, research in this area remains limited, particularly in terms of comprehensive and systematic reviews of industrial practices under real-world conditions. To bridge this gap, this article provides an in-depth review of hydrogen production, storage, and industrial applications, summarizing key features of thirteen exemplary hydrogen demonstration projects from around the world. The goal is to offer insights and guidance for the large-scale deployment of hydrogen energy while identifying potential technological pathways for the future.

0.37

Beyond Tomorrow -- Electrification of Hard-to-Abate Sectors

eess.SY ·2026-09-28 ·Jonas Huber, Johann W. Kolar
similarity 0.49
Abstract · Submitted to IEEE magazine

Reaching net-zero greenhouse-gas (GHG) emissions requires deep electrification beyond ground transportation, buildings, and conventional industry automation. This article discusses direct electrification pathways for hard-to-abate sectors, which today account for 30% of global GHG emissions and include steel, cement, chemicals, aviation, and shipping. Whereas indirect electrification via hydrogen and synthetic fuels will remain indispensable for some applications, direct use of electricity is generally preferable from an efficiency perspective. We review selected emerging opportunities for power electronics in industrial process electrification, including steelmaking through hydrogen plasma smelting reduction or molten-oxide electrolysis, electrified cement production, high-temperature process heat, plasma-assisted chemistry, and electrochemical synthesis. Across these examples, power converters must interface with highly application-specific loads, ranging from low-voltage high-current electrolysis cells to dynamic plasma reactors and megawatt-scale induction heating systems. In addition, high-power grid interfaces and in-plant energy management/buffering solutions must be clarified. Thus, future electrified industrial processes open new "beyond-tomorrow" research challenges for power electronics in close interdisciplinary collaboration with scientists from neighboring disciplines.

0.26

Life-Cycle Planning of Collector System for Deep-Sea Multi-Spatial Wind-PV-Tidal Farm

eess.SY ·2026-08-10 ·Wenhao Gao, Weitai Xu, Yunfei Du, Yongheng Wang, Xinwei Shen
published similarity 0.45
Abstract · 14 pages, 12 figures, and 6 tables. Accepted by CSEE Journal of Power and Energy Systems in August 2026

This paper develops a life-cycle optimization model for the collector system (CS) of deep-sea co-located energy farms (CEFs), where co-located energy turbines (CETs) integrate wind, photovoltaic (PV), and tidal current resources across sea-area layers. The model captures multi-layer marine-space complementarity, wake effects, and output variability, while accommodating diverse dynamic submarine cable configurations. To improve computational efficiency, the adaptive piecewise linearization (A-PWL) method based on the outputs of CETs is proposed to transform the original mixed-integer quadratic programming (MIQP) problem into a mixed-integer linear programming (MILP) form to approximate quadratic operation costs and simplify absolute power flow modeling. Case studies demonstrate that incorporating multi-energy complementarity significantly enhances the economic performance of deep-sea CEFs. When external physical risks are negligible, the fully-suspended cable configuration proves more cost-effective than the lazy-wave design. The proposed linearization method achieves high accuracy while significantly reducing solution time. Overall, this work provides a practical and scalable framework for efficient CS planning in offshore renewable energy systems.

0.55