CS Paper Radar

Fault Diagnosis and Fault-Tolerant Operation Strategy for Triple-Port Hydrogen Production System

Shiqi Zhang, Yiyina Teng, Yuhang Sun, Fanqin Ding, Ning Wang, Xiaoqiang Guo, Changchun Hua

eess.SY ·submitted 2026-11-14 14:22 UTC · v1
top venueunusualhighly cited

Abstract

The multi-port converter offers significant advantages in sustainable energy-based hydrogen production, such as high energy density and wide application potential. As the core energy hub in these systems, the multi-port hydrogen converter demands high reliability. However, its numerous switches and complex operation increase the risk of failure. Currently, there are no effective fault diagnosis or fault tolerance solutions for these systems. Current fault diagnosis methods for two-port and multi-port converters rely on many sensors, have low accuracy, and cannot handle multi-switch faults. Additionally, existing fault tolerance strategies fall short in maintaining stable power for the electrolyzer and do not allow capacity sharing among ports. This paper proposes a fault diagnosis method for open-circuit faults in a triple-port hydrogen converter and a corresponding fault-tolerant operating strategy. By optimizing a random forest algorithm with a sparrow search algorithm, high-precision multi-switch fault diagnosis is achieved using only three current sensors. Fault-tolerant operation of the system is achieved through an auxiliary switch after a failure. Additionally, power sharing between output ports can be realized. This ensures the efficient and stable operation of the hydrogen production system. The effectiveness of this solution has been validated through simulations and experiments.

Comment
10 pages, 21 figures
Journal ref
IEEE Transactions on Power Electronics, vol. 40, no. 8, pp. 11526-11536, 2025
DOI
10.1109/TPEL.2025.3552380

Closest papers

Nearest neighbours by meaning across the whole index.

Low-Ripple Modulation Strategy for a Photovoltaic-Based Triple-Port Hydrogen Production System

eess.SY ·2026-09-12 ·Shiqi Zhang, Ziang Jiao, Jiaxin Su, Ning Wang, Zheng Li +2 more
top venue similarity 0.53
Abstract · 13 pages. Accepted manuscript

Among various production methods, hydrogen generation via electrolysis powered by renewable energy plays a key role in achieving large-scale green hydrogen production. The triple active bridge isolated DC-DC conversion system exhibits significant application potential in hydrogen production due to its advantages, such as high energy density, wide step-down ratio, and high reliability. However, the output current ripple at the hydrogen production port critically affects the efficiency of the electrolyzer and the hydrogen production rate. Existing studies have limited optimization effects on current ripple and struggle to achieve dynamic optimization, leading to constrained ripple suppression under dynamic operating conditions. To address this issue, this paper proposes a low-ripple modulation strategy based on coordinated optimization of inner and outer phase-shift angles for multi-port power conversion systems in renewable energy hydrogen production. By establishing an accurate mathematical model, the optimal phase-shift angle combination under minimal current ripple conditions is derived. An improved differential evolution algorithm with adaptive parameter strategy is employed to achieve global optimization under dynamic conditions. Simulation and experimental results demonstrate that the proposed strategy effectively suppresses current ripple, providing an efficient and reliable solution for hydrogen production from fluctuating renewable energy sources.

0.65

Grid Integration of Gigawatt-Scale Hydrogen Hubs: A Multi-Timescale Stability Analysis and Connection Requirements for Weak Grid Environments

eess.SY ·2026-08-17 ·Mohamed Shamseldein
publishedcode/data similarity 0.49
Abstract

The global transition toward green hydrogen is driving the deployment of gigawatt-scale electrolysis centers, introducing a novel, converter-dominated load class to the bulk power system. Unlike conventional industrial loads, these facilities utilize extensive power electronics interfaces with fast dynamics comparable to Inverter-Based Resources (IBRs). This paper presents a comprehensive grid impact assessment of large-scale hydrogen hubs, focusing on harmonic injection, voltage stability in low Short Circuit Ratio (SCR) environments, and frequency response capabilities. Adopting a "full-spectrum" open-source modeling approach, the study utilizes PandaPower for large-scale steady-state contingency assessment; ANDES for electromechanical dynamic simulations to evaluate Fast Frequency Response (FFR); and ParaEMT for high-fidelity electromagnetic transient analysis of harmonic distortion and Low Voltage Ride-Through (LVRT). A critical finding of this study is that standard load models, including the generic PERC1 (data center) model, are insufficient for hydrogen hubs. The paper recommends specific structural modifications to the PERC1 model - specifically regarding process safety latches and restart voltage thresholds - to accurately capture the risk of prolonged plant tripping. Based on these findings, the paper proposes a set of standardized connection requirements to ensure secure integration.

0.57

Modeling and Parametrization of Large-scale Hydrogen Electrolyzers for Transient and Frequency Stability Analysis

eess.SY ·2026-10-29 ·Mahmoud K. Abdelhamid, Lukas Sigrist, Álvaro Ortega
similarity 0.43
Abstract

Hydrogen Electrolyzers (HEs), particularly Proton Exchange Membrane (PEM)-based systems, are flexible loads capable of providing grid ancillary services and enhancing the stability of renewable-dominated power systems due to their fast electrical response. However, the literature often lacks clear guidance on the structure, modeling, and parametrization of large-scale HEs for transient and frequency stability analyses. This paper presents a detailed configuration for utility-scale HE plants, using the stack as the fundamental unit, supported by a realistic parametrization based on commercial components. Furthermore, this work extends the Generalized ESS Model (GEM), a linearized state-space model previously utilized with other converter-interfaced energy storage systems, to PEM HEs for the first time. To facilitate plant scalability, a robust method for scaling GEM matrices across different capacities is proposed. Finally, a measurement-based methodology is developed to estimate the GEM parameters and subsequently extract the equivalent electrical circuit parameters. Comprehensive simulations on the WSCC system under various disturbances validate the accuracy of the derived GEM, the effectiveness of the scaling approach, and the robustness of the parameter identification methodology.

0.23

Hydrogen in Practice: A Global Review of Demonstration Projects from Production to Integration

eess.SY ·2026-11-14 ·Yiyina Teng, Shahab Dehghan, Xiaoqiang Guo, Shiqi Zhang, Yanming Wan +2 more
published similarity 0.42
Abstract · 49 pages, 15 figures

Hydrogen technology has the potential to address various challenges related to integrating low- and zero-carbon energy sources, as well as achieving carbon neutrality. It provides valuable solutions for transitioning to net-zero emission energy systems on a global scale. The implementation of hydrogen production and integration demonstration projects has received significant attention around the world and strong support from governments, highlighting the crucial role of such initiatives in the advancement of hydrogen energy. However, research in this area remains limited, particularly in terms of comprehensive and systematic reviews of industrial practices under real-world conditions. To bridge this gap, this article provides an in-depth review of hydrogen production, storage, and industrial applications, summarizing key features of thirteen exemplary hydrogen demonstration projects from around the world. The goal is to offer insights and guidance for the large-scale deployment of hydrogen energy while identifying potential technological pathways for the future.

0.37

Cross-modal topology decodes battery faults from sparse voltage snapshots

eess.SY ·2026-08-11 ·Jinwen Li, Yunhong Che, Simona Onori, Weihan Li, Xiaosong Hu
published similarity 0.42
Abstract · 33 pages, 12 figures

Battery safety remains the primary bottleneck for mass electric vehicle (EV) adoption, yet field monitoring is hamstrung by a fundamental asymmetry: complex electrochemical faults must be diagnosed via sparse, low-frequency voltage measurements. Existing methods struggle to resolve the signal ambiguity between overlapping fault modes without hardware upgrades. Here, we demonstrate that these distinct fault fingerprints are not lost, but topologically folded within voltage snapshots. We introduce DeFault, a cross-modal diagnostic framework that mathematically unfolds one-dimensional voltage sequences into multi-dimensional phase-space topologies. DeFault employs a bidirectional cross-attention mechanism that acts as an autonomous, physics-aligned filter, explicitly decoding compounded fault modes that remain fundamentally invisible to sequence-based methods. Validated on a field dataset of 16.4 million data records from 99 in-service EVs, our method achieves an average accuracy of 0.96 and an F1 score of 0.84 for four fault types using only 500-second snapshots (spanning <100 mV). This work proves that high-fidelity, interpretable electrochemical diagnosis is achievable on legacy fleets without new sensors, providing a scalable solution for the battery safety crisis.

0.28

Unit-to-Plant Stability Shaping of Multi-Electrolyzer ReP2H Plants via Interface Design and Dispatch

eess.SY math.OC ·2026-08-24 ·Miao Zhang, Yiwei Qiu, Xiaoyu Wang, Linlin Wu, Yi Zhou +3 more
similarity 0.42
Abstract

Alkaline water electrolysis (AWE) units supplied by insulated gate bipolar transistor rectifiers (IGBT-Rs) may experience oscil-lations caused by coupling between rectifier control and electro-lyzer (ELZ) dynamics. Because this risk varies with unit loading and power allocation, production-oriented dispatch may place a multi-ELZ renewable power-to-hydrogen (ReP2H) plant near or exceed its stability boundary. This paper proposes a stability-oriented framework for control design and plant production dis-patch. A three-port admittance model links the ac port, dc link, and electrolysis stack. Unit-level dc-port analysis quantifies the effects of loading, temperature, Buck bandwidth, and dc-link capacitance, while plant-level aggregation evaluates how unit commitment and power allocation affect stability. Results show that higher loading reduces stability, whereas larger dc-link ca-pacitance and higher Buck bandwidth improve it. Under the same plant loading, different power allocations result in different plant-level stability margins, with balanced allocation generally providing a larger margin than concentrated allocation. The plant-level model thus distinguishes the stability margins of ad-missible schedules. Hardware-in-the-loop (HIL) tests validate these trends and the proposed redistribution rule. The resulting operating regions and dispatch rules can be used to screen unit commitment and power allocation decisions in plant production scheduling.

0.23

Sensor Diagnosis for Fuel and Emissions Monitoring in Heavy-Duty Diesel Vehicles

cs.LG eess.SY ·2026-10-15 ·Tejas Dahiya, Saurabh Kumar Gupta
published similarity 0.41
Abstract · Accepted at the Tackling Climate Change with Machine Learning workshop at NeurIPS 2026

Faulty sensor readings can distort estimates of fuel use and carbon dioxide emissions from diesel engines. We evaluate two procedures that use relationships learned from healthy measurements to diagnose faults and guide fuel correction. The diagnosis procedure tests whether replacing a suspected faulty reading with an estimated healthy value helps a model predict another sensor's recorded reading more accurately. It then predicts the fault type and decides whether to report the diagnosis. We evaluate five synthetic fault types on 217 steady-state operating points from a heavy-duty diesel engine, excluding all measurements at selected engine speeds from training. Across 31,500 fault-injected groups of 20 operating points, it issues diagnoses for 77.3% of groups, with 92.1% of diagnoses issued on these groups correct. The fuel correction procedure uses a different sensor-selection rule at individual operating points, testing how each replacement changes the largest prediction error across all six sensors. Fuel correction requires a fault alarm and engine speed and torque close to the training conditions. A fuel reading is replaced only when its replacement reduces the largest prediction error sufficiently more than replacements for the other sensors. Assuming faults in 1% of one-hour scenarios, equally likely sensors and fault types, and equal time at each measured condition, selected fuel corrections reduce mean absolute error in calculated combustion CO2 by 83.8%. On this engine map, learned relationships support complete sensor diagnoses and fuel corrections that improve emissions accounting while preserving unaffected readings.

0.34

Understanding the limits of snapshot-based fault diagnosis in distribution networks

cs.AI ·2026-11-13 ·Ba Tu Phung, Huy Hoang Le, Kim-Anh Nguyen
similarity 0.41
Abstract

Inverter-based resources weaken fault currents in distribution networks, and snapshot-based diagnosis, which classifies a fault from voltage phasors at a few buses at one instant, offers a cheap first-stage screen. Its published accuracies, however, rest on different noise assumptions and do not show whether the error comes from the classifier, the features, the measurement error, or the fault resistance. This paper separates these sources on three IEEE test feeders and a public data set with distributed generation, using four feature sets, thirteen classifiers, and measurement error defined by total vector error classes. The classifier is not the limiting factor, because the full phasor snapshot classifies every fault correctly without noise, and the remaining error comes from measurement error on high-impedance faults. Three voltage sensors classify 90-96% of faults at the 1% accuracy class and 96-99% with distribution micro phasor measurement units (micro-PMUs). A discriminability-margin placement selects them from simulations alone in under one second and matches the best of twelve placement methods. The results show when snapshot-based diagnosis can be trusted.

0.25