CS Paper Radar

Mobile CT Services for Rural, Regional, and Remote Areas: Current Practice and Future Integration with Telehealth and Regulatory-Authorised AI

Zhicheng Lu, Md Zahid Islam, M Mamun Huda, Kristie Sweeney, Shayne Chau, Oliver Mulcock, Corey Hemopo, Catherine Keniry, Mohammad Ali Moni

cs.CV ·submitted 2026-09-13 07:12 UTC · v1
unusual

Abstract

Computed tomography (CT) plays an essential role in clinical workflow to improve patient outcomes. However, access to CT imaging and specialist interpretation remains limited, particularly in rural, regional, remote (RRR), and other resource-limited settings. Recent advances in mobile CT, telehealth, and artificial intelligence (AI) provide opportunities to extend advanced imaging services to populations in RRR settings. This review examines: 1) mobile CT systems deployed in trucks, trailers, ambulances, and other mobile platforms; 2) telehealth technologies supporting CT-based healthcare; and 3) AI for CT that has received regulatory authorisation or is currently deployed in clinical practice. Applications are evaluated across four clinical functions: screening and diagnosis, patient monitoring, risk prediction, and intervention or therapeutic decision support. The review covers neurological, thoracic, cardiovascular, abdominal, oncological, musculoskeletal, and interventional imaging, with particular attention to stroke, cancer, and other image-guided treatment. Other factors such as regulatory status, deployment status, and estimated technology readiness (TRL) level are compared. Current evidence indicates that mobile CT, telehealth, and AI for conventional CT are individually relatively mature, but fully integration of these technologies remains less widely deployed and validated in the clinical settings. Key barriers include regulatory variation, domain shift, connectivity requirements, cost, workflow integration, cybersecurity, and limited evidence of patient-level benefit. Future research should prioritise prospective, multicentre evaluation of integrated CT systems in real-world and underserved clinical settings.

Comment
18 pages, 3 figures, 4 tables

Closest papers

Nearest neighbours by meaning across the whole index.

Disentangling Lung-Cancer CT/LDCT AI: A Systematic Evidence Map of Clinical Tasks, Evidence Chains, and Translational Gaps

cs.LG ·2026-09-28 ·Surajit Das
similarity 0.59
Abstract

Artificial-intelligence studies using computed tomography (CT) for lung cancer are often broadly labelled "prediction" despite addressing clinically distinct tasks. We systematically mapped CT/low-dose CT (LDCT)-centered lung-cancer AI using five-database retrieval, full-text eligibility assessment, role-aware modality/omics extraction, clinical-task classification, and a Multi-Tier Evidence Graph (MTEG). The final corpus comprised 293 studies (2016-2026): 230 Detection, 8 future Risk-prediction, and 55 Other studies. Clinical variables (96.2%), 3D CT/LDCT (73.0%), and radiomics (63.5%) predominated, whereas external validation (29.0%), calibration (20.5%), decision-curve analysis (13.0%), longitudinal CT (17.7%), and saliency/attribution XAI (21.5%) were less frequent. The MTEG comprised 377 nodes and 3,444 edges; only 31 studies (10.6%) completed the six-tier substantive evidence chain, with greatest attrition at reasoning/explanation. Overall, the literature is detection-dominated, genuine future risk prediction remains uncommon, and complete translational evidence chains are rare.

0.08

Multi-Site Real-World Performance of Commercial AI for Pulmonary and Incidental Pulmonary Embolism Detection

cs.CV cs.AI ·2026-09-29 ·Aawez Mansuri, Mohammadreza Chavoshi, Theodorus Dapamede, Wasif Bala, Beatrice Brown-Mulry +11 more
published similarity 0.58
Abstract

Pulmonary embolism (PE) is a leading cause of cardiovascular mortality, yet the real-world performance of FDA-cleared AI detection models remains incompletely characterized. We retrospectively evaluated two FDA-cleared AI algorithms from a single commercial platform (Aidoc Medical BriefCase), one for PE triage on dedicated CT pulmonary angiography (CTPA; n = 30,678) and one for incidental PE (iPE) detection on routine contrast-enhanced CTs (n = 37,191), across a 17-facility academic health system. Reference-standard labels were extracted from radiology reports using a validated LLM pipeline (97% accuracy, kappa = 0.94). The PE model achieved 86.8% sensitivity and 99.1% specificity, with sensitivity declining from 99.3% for saddle emboli to 72.9% for subsegmental PE, and from 89.7% for acute to 65.3% for non-acute PE. The iPE model achieved 73.5% sensitivity and 99.8% specificity. Both models demonstrated lower sensitivity than FDA-clearance benchmarks while exceeding cleared specificity, with diminishing performance for peripheral and non-acute emboli mirroring known human reader limitations and underscoring the need for standardized post-market surveillance of AI-enabled medical devices.

0.25

Lessons learned from deploying imaging AI with the open PACS-AI platform

cs.CV cs.CY ·2026-09-22 ·Samuel Kadoury, Julie G. Hussin, Pascal Thériault-Lauzier, Laurent Létourneau-Guillon, Rob Lewis +9 more
similarity 0.55
Abstract · 28 pages (21 main text + 7 supplementary), 3 figures, 1 table

We describe deploying imaging AI at six hospitals through PACS-AI, an open self-hosted platform. The binding constraint is not model accuracy but infrastructure to route studies, display results, capture feedback, and audit what runs. At one center, angiography models completed 515 of 607 jobs (84.8%); failures reflected absent diagnostic views, and 78.1% of 638 clinician ratings were positive. Publishing honest readiness levels for every model is itself a governance practice.

0.31

Extending TotalSegmentator: Predicting Patient and Acquisition Characteristics from CT and MR Images

cs.AI ·2026-08-29 ·Jakob Wasserthal, Joshy Cyriac, Michael Bach, Kimia Mozahheb Yousefi, Minh-Son To +5 more
code/data similarity 0.54
Abstract

Background: Patient details and acquisition metadata are important for clinical decisions, image quality control, and automated research pipelines, but may be missing or unreliable in imaging archives. Purpose: To develop and evaluate a fast open-source model that predicts patient and acquisition characteristics directly from CT and MR images. Materials and Methods: Separate 3D ResNet-10 ensembles for CT and MR were trained on 57,291 and 43,200 clinical examinations acquired from 2011 to 2025. Both predicted weight, height, age, sex, contrast presence, vertebral coverage, and image noise. The CT model additionally predicted scanner manufacturer, tube voltage, tube current, convolution kernel, and post-injection time; the MR model predicted sequence class. Performance was evaluated on internal CT (n=501) and MR (n=636) test sets and an external CT dataset (n=54). Results: Internal CT MAEs were 3.90 kg, 3.68 cm, and 4.42 years for weight, height, and age, with sex F1=0.990; corresponding MR results were 4.34 kg, 4.62 cm, 7.13 years, and F1=0.970. The CNN outperformed a segmentation-derived XGBoost baseline for all four core targets in both modalities (adjusted P<=.042). F1 scores were 0.963 for CT contrast, 0.953 for MR sequence, and 0.823 for MR contrast. External CT MAEs were 4.45 kg, 4.05 cm, and 5.17 years, with sex F1=0.971. CPU inference required 20 seconds for CT and 12 seconds for MR. Conclusion: One 3D multitask model per modality can rapidly recover patient and acquisition characteristics from heterogeneous CT and MR examinations. Models are available in TotalSegmentator: https://github.com/wasserth/TotalSegmentator

0.43

Clinician-AI Collaboration in Endovascular Neurointerventions: In-Vitro User Study of Copilot Assistance Modes for Robotic Navigation Across the Autonomy Spectrum

cs.RO ·2026-11-02 ·Nikola Fischer, Harry Robertshaw, S. M. Hadi Sadati, Xingyu Chen, Weiyuan Deng +14 more
similarity 0.52
Abstract · 13 pages, 10 figures, 4 tables

Mechanical thrombectomy (MT) is an effective treatment for acute ischemic stroke, yet access remains limited by the availability of neurointerventional expertise. Telerobotic and AI-assisted systems may help address this challenge, but it remains unclear how clinicians interact with different levels of autonomy and how autonomous navigation systems perform in realistic environments. This work introduces Copilot Assistance Modes (CAMs), a framework for clinician-AI collaboration in robotic endovascular navigation spanning the autonomy spectrum from manual operation to full autonomy. In the first in-vitro user study comparing clinician-AI collaboration strategies, 11 experts and two students evaluated six navigation modes in a patient-specific vascular phantom. Objective performance metrics were combined with subjective assessments, including workload and usability. Autonomous performance was additionally evaluated both in silico and in vitro to investigate sim-to-real transfer. Hands-on manual navigation achieved the strongest overall performance (100% success). While fully autonomous navigation achieved 81% success in simulation, performance dropped to 23% in vitro. In contrast, several clinician-AI shared-autonomy modes achieved success rates of 92-97%, approximately four times higher than full autonomy and comparable to direct robotic control (95%), demonstrating mitigation of sim-to-real domain shift through clinician-AI collaboration. Among the evaluated AI-driven approaches, user-directed task delegation and rotational shared control demonstrated the most favorable balance between performance and clinician acceptance. These findings suggest that effective clinician-AI collaboration and allocation of control authority may currently be more important for reliable robotic neurointerventional navigation than increasing autonomy alone.

0.48

Auditable CT Phenotyping Through Report-derived Radiological Observations

cs.CV ·2026-08-26 ·Riga Wu, Walter Witschey, Yicheng Li, Felix Barajas Ordonez, Keno K. Bressem +7 more
similarity 0.52
Abstract

Medical image foundation models can predict clinical phenotypes from computed tomography (CT), but strong performance leaves open whether they read disease-specific findings or shortcuts that correlate with the diagnosis. We tested this in 221 electronic-health-record (EHR) phenotypes using Auditable CT phenotyping (ACT), built on report-derived radiological observations. We trained ACT on 38,317 patients, mined 376,194 observations and evaluated it in 25,183 held-out patients. ACT exceeded five vision-language baselines on zero-shot annotation, and CT-CLIP across 221 phenotypes from unseen CT pulmonary angiography, both under zero-shot scoring (0.651 versus 0.572) and under linear probing (0.709 versus 0.662). Reading each probe exposes what accuracy conceals: only 97 observations occupy the 221 rank-1 positions, and one phrase describing aortic and coronary calcification ranks first for 20 phenotypes, including osteoporosis, urinary tract infection and major depressive disorder. Restricting the bank to clinician-specified evidence redirects those probes onto phenotype-related observations in 86 phenotypes at no accuracy cost (0.751 versus 0.741). Accurate CT-based EHR phenotyping can therefore rest on observations that are not valid evidence for the coded phenotype and that ACT can identify and intervene on.

0.53

A frontier machine intelligence for human neuroimaging

cs.AI ·2026-11-11 ·Chenhui Zhao, Akshay Rao, Akhil Kondepudi, Yiwei Lyu, Xinhai Hou +17 more
similarity 0.51
Abstract · 41 pages, 4 main figures, 9 extended data figures

Medical imaging is essential for diagnosing disease, guiding treatment and monitoring patients over time. Although artificial intelligence has advanced image interpretation, existing medical models often address restricted tasks, while general-purpose proprietary models lack access to private clinical imaging required to achieve medical expertise. Developing models that can interpret complex examinations and communicate their findings in the context of clinical decisions remains a major challenge. Here, we show that Neuro-VL, a vision-language model trained on nearly one million neuroimaging studies from routine clinical care, can interpret complete imaging examinations and engage in natural language conversations about their findings. Across internal and international datasets, Neuro-VL outperformed frontier general-purpose and specialized medical models in diagnosing, localizing, and describing abnormalities, as well as generating comprehensive radiology reports. The model also compared serial examinations to assess disease progression and more reliably resisted misleading clinical assumptions than leading frontier models from OpenAI and Google. These results extend health system learning beyond individual predictions to interactive image interpretation and longitudinal disease monitoring. They demonstrate how the collective clinical experience of health systems can be used to develop medical AI with specialized expertise and broad clinical capabilities.

0.40

AMPLIFAI: A Multiphase CT Dataset for Benchmarking Clinical Reasoning in LI-RADS Assessment of Liver Lesions

cs.CV cs.LG ·2026-08-14 ·Pranav Kulkarni, Nikhil Shah, Amritansh Suryavanshi, Jana G. Delfino, James Tonascia +7 more
dataset similarity 0.51
Abstract · 15 pages, 6 figures, 3 tables

Hepatocellular carcinoma (HCC) is the third leading cause of cancer-related mortality worldwide, with early detection improving survival from <20% to >70%. The standardized Liver Imaging Reporting and Data System (LI-RADS) criteria provide an imaging-based diagnostic framework to evaluate liver lesions for HCC, serving as a foundation for automating HCC detection with artificial intelligence (AI). However, the lack of large, publicly available datasets with high-quality annotations has limited the development and evaluation of AI models for automated LI-RADS assessment. We introduce AMPLIFAI dataset, the first public dataset of 590 multiphase abdominal CT studies annotated with LI-RADS categories, lesion size, and voxel-level segmentations for three major LI-RADS features: arterial phase hyperenhancement, washout, and enhancing capsule. The dataset was curated and harmonized from four public datasets and augmented with expert annotations from five board-certified radiologists and one resident. Following the Datasheets for Datasets format, this paper details the dataset's composition, curation and harmonization process, and annotation workflow to support transparent, reproducible research in medical imaging AI.

0.10