CapsuleMotion: A Lightweight Real-Time Visual Motion Predictor for Capsule Endoscopy

Oliver Bause, Julia Werner, Oliver Bringmann

cs.CV ·submitted 2026-09-14 10:52 UTC · v1
published

Abstract

Video Capsule Endoscopy (VCE) is a non-invasive medical examination that allows for the observation of the small intestine, which is otherwise difficult to access. A fundamental challenge persists in the form of their limited size in order to still be swallowable. The resulting restricted battery capacity, however, contradicts with the power-intensive nature of image capture and transmission. Therefore, we propose CapsuleMotion, a patient-specific dynamic capsule behavior that utilizes the available energy in a goal-oriented manner to increase the likelihood of a complete screening of the gastrointestinal tract. By investigating and combining metrics from the on-device image compression, CapsuleMotion predicts the motion between two successive frames. The camera's frame rate will be modified in accordance with the predicted magnitude of motion. Furthermore, prior to entering the small intestine, the capsule operates in a low power mode with a significantly reduced frame rate. In this mode, the LocalizationNet is employed to determine the current organ, provided that motion was predicted. The proposed framework is evaluated on the Rhode Island VCE dataset and deployed on an ultra-low power single-core RISC-V demonstrator with an integrated hardware accelerator. CapsuleMotion demonstrated the capability to reduce electric energy consumption by up to 20.66% in comparison with conventional capsules that lack a dynamic frame rate. Additionally, the accuracy of detecting the entry point of the small intestine has been improved.

Comment
4 pages, 3 figures, 2 tables, accepted at the 22nd Annual International Conference on Body Sensor Networks (BSN2026)

Closest papers

Nearest neighbours by meaning across the whole index.

Rare Disease Classification in Video Capsule Endoscopy

eess.IV q-bio.TO ·2026-09-14 ·Amit Kumar Patel, Debesh Jha
similarity 0.62
Abstract

Video capsule endoscopy offers a non-invasive way to examine the small bowel, however, the rare but clinically important findings that appear only in less than 1\% of labelled frames, provide very less signal for detection. As a result, while models can achieve high overall performance, they almost completely miss these rare findings. We condition each frame's decision on evidence from the rest of that patient's video, not on the frame's own posterior alone, supplying information a single frozen frame can never contain. Building upon Expected Gain Arbitration, a per-frame, macro-F1-optimal correction over the confusion matrix, we further compose it with video-disease-presence conditional resulting in our decoding method Hierarchical Conditional-Expected-gain (HCE). We evaluate HCE on two independent VCE datasets, Kvasir-Capsule and GALAR, against a static temporal-smoothing baseline and an optimal-transport (OT) frame-level correction. HCE significantly improves rare-class recall over a temporal-smoothing baseline on GALAR (2.7--3.1x; 95\% CI excludes zero in both scopes) and shows a similar, though not statistically confirmed, gain on Kvasir-Capsule (up to 3.4x). Against OT, HCE still improves rare-class recall in all four evaluation settings (+0.016 to +0.029), and additionally improves macro-F1 and MCC.

0.16

UnCapsTSR: An Unsupervised Transformer-based Image Super-Resolution Approach for Capsule Endoscopy Images

cs.CV ·2026-09-02 ·Anjali Sarvaiya, Shubh Kawa, Lalit Agrawal, Jagrit Joshi, Kishor Upla +1 more
publishedhighly cited similarity 0.59
Abstract · Accepted manuscript of the article published in Neurocomputing, Volume 665, Article 132161, 2026

Wireless Capsule Endoscopy (WCE) captures and streams video while passing through a patient's Gastrointestinal (GI) tract and is used to examine its irregularities. Although advantageous over conventional endoscopy, WCE suffers from limitations related to capsule size and wireless transmission, resulting in images with coarser resolution. This work presents UnCapsTSR, an unsupervised transformer-based Generative Adversarial Network (GAN) framework for improving the spatial resolution of Low-Resolution (LR) WCE images. The proposed method accomplishes SR without explicit degradation estimation of real-world LR data and eliminates the need for true LR-HR pairs. UnCapsTSR employs a Bilateral Total Variation (BTV) loss to ensure spatial continuity in SR images. A newly curated dataset from the Kvasir Capsule dataset is also presented for training WCE SR models. Generalizability is validated on KID and GIANA datasets that are not used during training. A new non-reference metric, Endoscopy Quality Metric (EndoQM), is introduced for quantitative evaluation of domain-specific WCE data. Experiments demonstrate consistent improvement over state-of-the-art unsupervised SR approaches using NIQE, BRISQUE, PIQE, and EndoQM. Statistical evaluation shows 40 to 80 percent improvement in EndoQM from LR to SR across the evaluated datasets.

0.66

CEM-TUDASR: Computationally efficient multi-modality transformer based unsupervised domain adaptive super-resolution approach

cs.CV ·2026-09-10 ·Anjali Sarvaiya, Jay Kadel, Kishor Upla, Kiran Raja
published similarity 0.55
Abstract · Published in Biomedical Signal Processing and Control, Volume 129, 2027, Article 111315

Wireless Capsule Endoscopy (WCE) enables non-invasive visualization of the gastrointestinal tract, but its miniaturized optics, sensor limitations, and wireless transmission constraints result in low-resolution images with reduced visibility of diagnostically important structures. This paper proposes CEM-TUDASR, a computationally efficient unsupervised Transformer-based super-resolution framework for WCE image enhancement without paired low-resolution (LR) and high-resolution (HR) training data. A domain-adaptive degradation network synthesizes realistic WCE-like LR images from HR conventional endoscopy images, reducing the domain gap and enabling effective unpaired learning. The SR generator integrates Deep Attention Blocks (DABs) and a Fusion Attention Block (FAB) to capture long-range contextual dependencies and fine local structures while preserving perceptual and structural fidelity. The model is trained on a curated dataset derived from Kvasir Capsule and evaluated on KID and GIANA for cross-dataset generalization. No-reference quality metrics, including BRISQUE, PIQE, NIQE, and the domain-specific EndoQM, show that CEM-TUDASR consistently outperforms existing unsupervised SR methods. Qualitative results further demonstrate improved restoration of mucosal textures, vascular patterns, and clinically relevant anatomical details. Cross-domain experiments on retinal images additionally demonstrate the adaptability of the framework. With only 2.67 million parameters and 169.94 GFLOPs, CEM-TUDASR achieves high-quality reconstruction while maintaining computational efficiency, making it suitable for resource-constrained clinical and embedded endoscopic applications.

0.18

On the Robustness of Temporal Vision-Language Models for Surgical Endoscopy Videos

cs.CV ·2026-08-14 ·Darakshan Rashid, Raza Imam, Ufaq Khan, Muhammad Bilal, Shazad Ashraf +7 more
top venuebenchmark similarity 0.55
Abstract · Accepted to MICCAI 2026

Temporal vision-language models (TVLMs) offer a reusable, prompt-based interface for surgical video understanding, yet, their robustness under clinically realistic acquisition artifacts in endoscopy remains insufficiently characterized. In practice, degradations such as defocus, haze, motion blur, noise, cautery smoke, and packet loss introduce structured distribution shifts which may compromise video-text alignment. We study the robustness of temporal VLMs under such shifts caused by corruptions in clip frames. We introduce Endo-C6, a compact corruption benchmark of six endoscopy-realistic perturbations evaluated at a fixed high severity, and apply it to public Gastrointestinal (GI) endoscopy and laparoscopic cholecystectomy videos. Under a standardized prompt protocol, we benchmark 3 recent surgical TVLM baselines and analyze robustness in both mean and worst-case settings, spanning 294 dataset-level evaluations. Finally, we present RobustEndoCLIP, obtained by few-shot parameter-efficient tuning with VeRA, outperforming existing TVLM baselines. Our findings show that off-the-shelf TVLMs can exhibit severe worst-case collapse under endoscopy-specific corruptions, whereas lightweight few-shot adaptation can substantially improve corrupted performance and robustness without changing the prompt-based interface. We expect Endo-C6 to support standardized robustness reporting and promote more reliable clinical vision-language systems.

0.29

EndoSCOP-V: A Multi-Turn Video Understanding Evaluation Framework for Multimodal Models in Endoscopy Reporting and Clinical Reasoning

cs.CV cs.AI ·2026-11-07 ·Abhishek Tyagi, Tanmay Jain, Vilas Biradar, Krithi Krishna Koduri, Misba Hul Bashir Masoodi +13 more
published similarity 0.55
Abstract · NeurIPS 2026

Endoscopic diagnosis unfolds over native video, where a single positive finding during traversal of the gastrointestinal tract sets off a multi-minute chain of reasoning over location, morphology, severity and intervention. Existing endoscopy multimodal benchmarks test only static images or single-disease videos, which miss the temporal and clinical reasoning that real-world reporting demands. We introduce EndoSCOP-V, a video-grounded multi-turn evaluation framework for structured endoscopy reporting and clinical reasoning. It contains 1,307 real-world endoscopy and colonoscopy videos (63.2 h; 97% 1080p) averaging about 174 s. Its 20,274 question-answer turns are instantiated deterministically from clinician-filled structured endoscopy-reporting EHRs, so no per-case annotation is synthetic or LLM-rephrased. They come from 1,033 clinician-reviewed templates, about 18 per disease, that span a clinically aligned 9-task x 30-sub-task reporting taxonomy over 54 World Endoscopy Organization (WEO) MST 3.0 diseases. 22% of procedures carry co-existing pathologies, up to six per case. A Markovian context-pruned oracle-forcing protocol evaluates the dialogue turn by turn, injecting the gold answer before each subsequent turn so that per-turn reasoning is isolated from cascading dialogue errors. A panel of 15 board-certified endoscopists sets a 78% strict-accuracy baseline on 1,500 questions. Across 14 open-weight LMMs, the best 27B-class model reaches 59.8% strict accuracy, falling to 53.4% once format-trivial disease-rejection items are excluded. On a between-subjects spot-check, the best of 3 frontier proprietary models trails the clinician panel by 23 pp on strict NDR accuracy. Sub-task analysis reveals consistent gaps in quantitative measurement, multi-variable grading and intervention reasoning on long-horizon video. Data: Hugging Face (EndoSCOP-V). Code: GitHub (abhi25t/EndoSCOP-V).

0.26

Accuracy Is Not Enough: An Efficiency- and Statistics-Aware Benchmark of ResNet50 and Vision Transformer for Explainable Multi-Class Gastrointestinal Diseases Classification

cs.CV ·2026-10-25 ·Akwasi Asare
benchmarkhot direction similarity 0.54
Abstract

Automated classification of gastrointestinal (GI) findings in endoscopic images could support early diagnosis, but architectures are often chosen on accuracy alone. We present a controlled, reproducible benchmark of ResNet50 and ViT-B/16 for eight-class GI classification on the public Kvasir dataset (4,000 images), using a stratified split (400 test images) and stratified group 5-fold cross-validation over all images. In cross-validation, ResNet50 and ViT-B/16 reached 92.12% and 91.70% accuracy, and a two one-sided tests (TOST) procedure showed equivalence within a +/-3 percentage-point margin (difference +0.43 points, 90% CI -0.33 to +1.18; p < 0.001). The architectures differed mainly in cost: ResNet50 had 3.6 times fewer parameters and 4.3 times fewer operations, 2.5-fold lower single-image CPU latency (69 vs. 177 ms) and 3.8-fold higher GPU throughput. Cross-validated calibration was similar (expected calibration error 0.021 vs. 0.023). An edge-oriented transformer, MobileViT-S, was most accurate on the test split (95.5%) but lost 9.4 points when an acquisition artefact present in some classes (the ScopeGuide inset) was occluded, whereas ResNet50 was not significantly affected. On 500 unseen polyp images with expert masks, both models' Grad-CAM maps focused on the lesion (3.6 times chance). On a de-duplicated external subset of GastroVision (1,998 images), accuracy fell to 78-80% for all three models and differences between them remained small. Accuracy differences between architectures were thus small relative to the effects of shortcut learning and domain shift, whereas efficiency differences were large. An efficient CNN is a defensible default for resource-constrained screening, but no model is deployment-ready without local validation.

0.29

EndoPrior-GS: Dynamic Endoscopic Reconstruction with a Joint Texture Prior

cs.CV ·2026-09-29 ·Jiaqi Huang, Shidong Wang, Tong Xin, Kabita Adhikari
publishedbenchmarkcode/data similarity 0.54
Abstract · Accepted at ACCV 2026. Code: https://github.com/jiaqi-huang-77/EndoPrior-GS

Dynamic endoscopic reconstruction is fundamental to robotic surgery and computer-assisted interventions. While 3D Gaussian Splatting (3DGS) realises real-time rendering, its application to deformable intraoperative environments remains constrained by spurious geometry and varying illuminations. To address these limitations, we introduce EndoPrior-GS, a novel pipeline that explicitly couples frame-extracted vision heuristics and estimated depth maps. EndoPrior-GS derives a joint texture prior from a tool-filtered valid tissue mask, a non-specular photometric filter, and anatomical structural salience, yielding a probability map that guides primitive initialisation and subsequent density control. The prior is further extended to the temporal domain through a texture-aware term that dynamically weighs pairwise primitive contributions during training. We conduct extensive experiments on benchmark datasets EndoNeRF and SCARED, and the obtained results show that our method EndoPrior-GS reduces Flow Error by 27.7% and 25.8% over the representative approaches while preserving competitive rendering quality and real-time rendering speed. Our project website is available at https://jiaqi-huang-77.github.io/EndoPrior-GS/.

0.37

Cross-dataset harmonization for robust endoscopic image analysis

cs.CV ·2026-10-05 ·Romil Imtiaz, Dimitris K. Iakovidis
similarity 0.54
Abstract

A significant problem in endoscopic image analysis is that the machine learning (ML) models used for this purpose usually underperform when applied on images acquired from endoscopes that are different from those used to acquire the images of their training set. The main difference of the images originating from different endoscopes is their color distributions, which depend both on the image sensors and the light sources used. Although previous studies have highlighted this challenge, to the best of our knowledge it has not been previously explicitly tackled. This study focuses on this problem and proposes very simple but impactful method. It implements a reference-based image harmonization that reduces global appearance differences between endoscopic datasets. Specifically, it extracts global color statistics from a chosen reference dataset in the CIE-Lab color space and applies a statistical channel-wise transformation to map each target image toward the appearance of the images of the reference dataset. The method is evaluated in the context of polyp detection in both flexible colonoscopy and capsule endoscopy datasets using a dataset-level cross validation protocol. The results indicate that the proposed harmonization consistently improves cross-dataset performance up to 30.7%, outperforming relevant baseline and state-of-the-art methods. The results indicate that a substantial part of the generalization gap is driven by low-level appearance variation that can be mitigated without retraining.

0.20