CS Paper Radar

Development of a 4D Cerebral Microvascular Imaging Platform for Mouse Stroke Model

Yoshihisa Kaneko, Moe Kumai, Hiroyuki Igarashi, Daisuke Ando, Kuniyasu Niizuma, Hidenori Endo, Yoshifumi Saijo, Takuro Ishii

eess.SY q-bio.QM ·submitted 2026-09-15 05:43 UTC · v1

Abstract

In ischemic stroke, changes in cerebral hemodynamics during both the ischemic and reperfusion phases strongly influence stroke outcomes. However, these hemodynamic changes remain incompletely understood. To address this challenge, we devised an imaging platform that enables time-resolved ultrasound microvascular imaging during the experimental induction of ischemia and reperfusion in a mouse model. The platform leverages our previous ultrasound imaging framework combined with continuous mechanical scanning, which acquires whole-brain blood-flow signals within 5 s. The experiments demonstrated that the proposed platform can visualize both local and whole-brain hemodynamic responses to the induction of ischemia and reperfusion, suggesting its potential for rapid and continuous whole-brain hemodynamic assessment in small-animal models.

Comment
4 pages, 6 figures, This work has been submitted to the IEEE IUS 2026 conference for possible publication. Copyright may be transferred without notice, after which this version may no longer be accessible

Closest papers

Nearest neighbours by meaning across the whole index.

Spectrally optimized implicit neural representations mitigate acquisition-related image quality trade-offs in intracranial 4D Flow MRI

eess.IV cs.CV ·2026-10-23 ·Oliver Welin Odeback, Nerea González-Aranceta, Sebastián Jofre, Javier Bisbal, Edward Ferdian +10 more
similarity 0.62
Abstract · 36 pages, 7 main figures, 2 supplementary figures. Under review at Medical Image Analysis

4D Flow MRI promises opportunities for non-invasive mapping of neurovascular hemodynamics, but its clinical utility faces trade-offs between resolution, acquisition time, and noise. Deep learning-based super-resolution offers a post-scan solution, but supervised approaches require paired or domain-specific data, while patient-specific physics-informed models can be computationally demanding. This creates a need for unsupervised reconstruction models that can adapt to individual acquisitions without paired high-resolution training data, while remaining robust across anatomy, disease severity, and acquisition quality. To address this, we introduce a spectrally tuned implicit neural representation (INR) framework for intracranial 4D Flow MRI, representing the velocity field as a continuous coordinate-based neural field using WIRE activation functions with tunable spectral bias. Data-driven and physics-informed variants were evaluated in nine cerebrovascular cases spanning healthy controls and moderate-to-severe intracranial atherosclerotic disease, using CFD-derived high-resolution reference fields, MR-realistic synthetic low-resolution inputs, and direct fitting to acquired in-vivo data. Cohort-optimal spectral-bias settings generalized across subjects with only small increases in relative error compared with subject-specific optima, reducing the need for case-specific hyperparameter tuning. Physics-informed regularization provided modest additional accuracy but required substantially longer optimization, whereas the data-driven INR achieved near-comparable reconstruction performance within minutes. The framework also remained robust to acquisition-realistic noise and moderate VENC-dependent aliasing. These findings establish spectrally optimized INRs as a flexible unsupervised approach for mitigating acquisition-related trade-offs in intracranial 4D Flow MRI.

0.21

Attention-guided super-resolution of 4D flow MRI in carotid arteries

cs.AI physics.med-phphysics.flu-dyn ·2026-09-04 ·Ali Mokhtari, Dominik Obrist
similarity 0.59
Abstract

Four-dimensional (4D) flow magnetic resonance imaging (MRI) is a powerful non-invasive technique for visualizing and quantifying complex blood flow patterns in vivo. Despite its clinical promise, broader adoption is limited by low spatial resolution and sensitivity to noise, which restrict accurate assessment of critical hemodynamic biomarkers such as wall shear stress, pressure gradients, and turbulent kinetic energy. To overcome these challenges, we propose a deep learning-based super-resolution framework that integrates multi-scale feature extraction and attention mechanisms to enhance the quality of 4D flow MRI data. The model was trained on a dataset of 120 patients with 240 stenosed carotid arteries. High-resolution ground truth data were generated using patient-specific computational fluid dynamics (CFD) simulations based on segmented vascular geometries and physiologically realistic boundary conditions, and the resulting velocity fields served as targets for supervised learning. The proposed architecture uses convolutional block attention modules (CBAM) to guide the network toward clinically relevant spatial features and to suppress noise in low-resolution inputs. Quantitative results show that the attention-guided model substantially reduces the root mean square error (RMSE) compared with a baseline model without attention, and qualitative velocity contour analysis confirms improved reconstruction of intricate flow patterns. These findings highlight the capacity of the model to restore high-fidelity flow fields under noisy conditions and support the use of deep learning to extend the clinical utility of 4D flow MRI for non-invasive hemodynamic assessment.

0.25

An Imaging-Informed Reaction-Diffusion Model of Infarct Growth

cs.CE ·2026-08-21 ·Muhammad Hussnain Abbas, Michal Balcerak, Asif Ahmad, Bjoern Menze, Ezequiel de la Rosa
published similarity 0.58
Abstract · Accepted at MICCAI 2026 Satellite Events (LNCS). 11 pages, 1 figure, 2 tables

Predicting final ischemic infarct volumes from acute imaging is a cornerstone of personalized stroke management, yet current strategies remain polarized between uninterpretable machine learning architectures and overly detailed electrophysiological models that are intractable in clinical imaging settings. We bridge this clinical gap by introducing the first imaging-driven framework that parameterizes a Fisher-KPP reaction-diffusion partial differential equation (PDE) directly from clinical acute MRI. The continuous state variable $u(\mathbf{x},t)\in[0,1]$ models tissue damage, capturing the forward expansion of ionic stress through the extracellular space alongside a localized metabolic commitment to cell death gated within the baseline perfusion deficit ($T_{\max}>6$\,s). Evaluating this paradigm on a subset of the ISLES 2017 dataset ($N=29$) via an oracle framework reveals that incorporating biophysical propagation constraints yields a mean Dice score of $0.46 \pm 0.24$, compared to standard rCBF thresholding ($0.25 \pm 0.21$). Extensive ablations demonstrate that modeling spatially heterogeneous diffusion fields derived from clinical perfusion maps accurately captures penumbral expansion, while providing full physiological interpretability. This proof-of-concept establishes that first-principles physics could capture complex ischemic progression directly on clinical scan grids, shifting the paradigm from purely data-driven models toward patient-specific biophysical forecasting.

0.42

AsymFeX: A Symmetry-Driven Framework for Ischemic Stroke Segmentation Across Imaging Modalities and Stroke Stages

eess.IV cs.CV ·2026-08-20 ·Maunil Shah, Vaanathi Sundaresan
code/data similarity 0.54
Abstract

Fast and accurate segmentation of Acute Ischemic Stroke (AIS) lesions is essential for stroke prognosis and treatment planning. Non-contrast CT (NCCT), the first-line imaging modality for diagnosing ischemic infarcts, exhibits subtle infarct contrast, making manual delineation slow and labor-intensive. Motivated by this, and by the clinical practice of comparing brain hemispheres to localize infarcts, we propose a two-stage, nnU-Net-compatible 3D segmentation method. The first stage corrects head tilt to align each scan to its true anatomical mid-sagittal plane; the second applies a novel Asymmetric Feature Extraction (AsymFeX) module, comparing each voxel to its true contralateral counterpart within a local 3 x 3 x 3 neighborhood via cross-hemispheric attention, feature disparity estimation, and dual-scale gating to capture both large and small infarcts. On AISD, our method achieves 0.6796 Dice, 23.53 mm HD95, and 7.69 mL AVD, significantly outperforming existing state-of-the-art methods, with clinically relevant volumetric analysis at the 70 mL thrombolysis-eligibility threshold. Proof-of-concept evaluation on ATLAS v2.1 and ISLES'24 demonstrates that the same symmetry-driven design generalizes across imaging modalities and stroke time points without architectural changes, further supported by an uncertainty analysis assessing reliability under clinical deployment. Code is publicly available at https://github.com/biomedia-lab/AIS-detection.

0.42

Automated carotid artery atherosclerotic inflammation segmentation in PET using MSR-Net

cs.CV physics.med-ph ·2026-10-11 ·Ran Li, Abhinav K. Jha, Jie Zheng, Richard Laforest, Yongjian Liu +6 more
published similarity 0.54
Abstract

Objective. To develop an automated method for segmentation and uptake quantification of carotid atherosclerotic inflammation on 64Cu-CANF-comb PET while accounting for partial-volume and tissue-fraction effects. Approach. Synthetic carotid PET images with known fractional-volume ground truth were generated by combining MR-derived high-resolution activity maps with GATE Monte Carlo simulation incorporating major PET physical processes and matched to the Biograph mMR acquisition and reconstruction. A two-stage network first localized the carotid vessel wall from T1-weighted MR and then estimated voxel-wise inflammation fraction from masked PET. Both stages used a multiscale residual (MSR) convolutional backbone. Performance was compared with U-Net, Transformer U-Net, DUCK-Net, and iterative Yang partial-volume correction. Main results. In a two-alternative forced-choice study, five nuclear-medicine physicians identified real images with 54% accuracy (54/100; Wilson 95% CI 0.44-0.63; exact binomial p = 0.48). On 184 simulated test slices from five held-out patients, the proposed method achieved a weighted DSC of 0.79, compared with 0.73 for U-Net, 0.69 for Transformer U-Net, and 0.75 for DUCK-Net, with corresponding HD values of 1.85, 2.29, 2.32, and 2.23 voxels. Patient-cluster bootstrap comparisons favored the proposed method for DSC and HD against all three baselines (Holm-corrected p <= 0.031). Overall ENRMSE was 0.24 versus 0.59, 0.68, and 0.59 for the three DL baselines and 0.57 for iterative Yang. In seven patients, corrected SUV showed a positive association with MR-derived lipid-rich/necrotic core with hemorrhage. Significance. The proposed framework improved carotid PET segmentation and uptake quantification under simulated conditions. The patient analysis is preliminary and requires external validation with biological reference standards before clinical deployment.

0.33

Toward Clinical Translation of Deep Learning-Based Intracranial Super-Resolution 4D Flow MRI Using Multi-Cohort Transfer Learning

cs.CV ·2026-10-26 ·Oliver Welin Odeback, Susanne Schnell, Patrick Winter, Johan Lundberg, Fredrik Piehl +3 more
hot direction similarity 0.54
Abstract · 28 pages, 6 main figures, 4 main tables; supplementary material includes 6 sections, 2 figures, and 1 table

We evaluated synthetic pretraining and multi-cohort transfer learning for deep learning-based super-resolution of intracranial 4D Flow MRI across heterogeneous neurologic cohorts. This mixed prospective-retrospective study analyzed 18 participants (12 healthy participants, 3 with moyamoya disease, and 3 with multiple sclerosis) with paired 1.2-mm and 0.6-mm 4D Flow MRI scans. A convolutional neural network pretrained on synthetic cerebrovascular data was fine-tuned using cohort-specific or pooled multi-cohort in vivo data. High-resolution-derived inputs enabled voxel-wise evaluation; native standard-resolution scans were used for angiographic and hemodynamic analyses. Synthetic pretraining reduced mean artery-wise velocity-normalized root mean square error (vNRMSE) versus interpolation (0.147 vs 0.166). Pooled transfer learning yielded the lowest mean vNRMSE (0.119 vs 0.127 for cohort-specific models and 0.147 for synthetic pretraining), with narrower 95% limits-of-agreement widths than synthetic pretraining across all test cases (0.109-0.222 vs 0.154-0.278 m/s). Super-resolved phase-contrast angiography achieved higher precision-recall area under the curve than native standard-resolution imaging in all cohorts (0.848-0.896 vs 0.486-0.805). These results indicate that pooled transfer learning improves cross-cohort reconstruction agreement and that super-resolution can improve vessel depiction, supporting further multi-center validation for cerebrovascular imaging.

0.25

Retrospective macromolecular pool fraction mapping from conventional clinical MRI: a physics-guided self-supervised deep learning framework

cs.CV physics.med-phcs.LG ·2026-10-27 ·Jelmer van Lune, Miha Fuderer, Oscar van der Heide, Matteo Maspero, Martin B. Schilder +3 more
similarity 0.54
Abstract · 38 pages, 24 figures

Macromolecular pool fraction (MPF) is a quantitative imaging biomarker sensitive to myelin integrity and other changes in tissue macromolecular content, but specialized acquisitions and reconstruction methods limit its use in large-scale studies. We present a physics-guided, self-supervised deep learning framework for retrospectively estimating MPF directly from conventional clinical brain MRI ($T_1$-weighted, $T_2$-weighted, and fluid-attenuated inversion recovery [FLAIR]) without paired quantitative reference scans. The framework embeds an analytical two-pool magnetization transfer signal model that related sequence-averaged radiofrequency transmit power to apparent longitudinal relaxation. To accommodate heterogeneous clinical protocols, the network conditions intermediate features on acquisition parameters via adaptive instance normalization. It was trained and evaluated on a multisite, multivendor, multiprotocol dataset of 7,705 MRI sessions (3 T). Across 1,237 test sessions, mean MPF was $0.182 \pm 0.007$ in white matter and $0.144 \pm 0.009$ in gray matter, with limited variation across vendor-by-protocol groups (between-group coefficient of variation: 2.65% and 5.63%, respectively). In 70 sessions with demyelinating-disease labels, MPF was 35.6% lower in segmented lesions than in normal-appearing white matter. MPF maps from two different clinical protocols acquired in a healthy volunteer showed a mean voxel-wise absolute percentage difference of 7.7% and a concordance correlation coefficient of $0.888$, indicating good cross-protocol consistency. These results suggest that magnetization transfer-informed self-supervised learning enables stable MPF mapping from conventional clinical MRI, providing a scalable approach to investigate demyelinating pathology in both existing imaging archives and prospectively acquired conventional clinical scans without dedicated qMT acquisitions.

0.28

Synthesizing Post-Acetazolamide Cerebral Blood Flow Maps from Baseline MRI in Moyamoya Using 3D Generative AI

eess.IV cs.AIcs.CV ·2026-08-14 ·Julia Huang, Camila Gonzalez, Rydham Goyal, Aja Zou, Sasha Alexander +3 more
top venue similarity 0.54
Abstract · 25 pages. Accepted at Machine Learning for Healthcare (MLHC 2026). To appear in Proceedings of Machine Learning Research (PMLR), volume 340

For patients with Moyamoya disease, impaired cerebrovascular reserve (CVR) is an important hemodynamic criterion for recommending extracranial-to-intracranial bypass surgery. Standard CVR assessment in this cohort uses paired arterial spin labeling (ASL) perfusion MRI acquired before and after acetazolamide (ACZ). When ACZ is contraindicated or avoided, the post-ACZ cerebral blood flow (CBF) map needed for hemodynamic assessment is unavailable. We propose CAE3D, a deterministic 3D conditional autoencoder that synthesizes post-ACZ CBF maps directly from pre-ACZ ASL input. We evaluated CAE3D against ten comparators, including deterministic and diffusion-style 3D baselines, a 2D contextual baseline, and frozen-encoder foundation-model adapters. CAE3D achieved the lowest held-out MAE (0.066), with SSIM 0.80 and PSNR 24.0 dB, and near-zero full-brain mean bias. Its MAE advantage was statistically significant over seven of eight trained-from-scratch baselines, excluding the 2D CAE_2D comparator; its SSIM and PSNR advantages were significant over all eight. Regional delta-CBF predictions compressed the dynamic range in high-response territories. These results establish the retrospective feasibility of post-ACZ CBF synthesis in patients who completed the standard two-scan protocol. Extension to ACZ-contraindicated patients, who were not represented in this cohort, requires external and prospective validation.

0.37