CityLearn v3: A Configurable Simulation and Evaluation Framework for Realistic Control Studies of Renewable Energy Communities

Tiago Fonseca, Luis Lino Ferreira, Armando Sousa, Ava Mohammadi, Zoltan Nagy

cs.MA cs.AI ·submitted 2026-09-18 10:01 UTC · v1

Abstract

Renewable energy communities (RECs) coordinate buildings, photovoltaic generation, batteries, electric vehicles and flexible loads. Controller studies often simplify changing participation, equipment availability, service deadlines and data quality, so lower cost or peak demand can conceal missed services or infeasible power requests. This paper presents CityLearn v3, a configurable simulation and evaluation framework for REC control studies under these conditions. It represents changing members and assets, flexible-load deadlines, demand-response requests, local energy sharing, and data or equipment failures within one simulation environment. Building and phase power limits constrain controllable requests, while a declared timestep preserves consistent power-to-energy accounting. The framework records controller inputs and distinguishes requested actions from those applied to the simulated equipment. Reference controllers, service- and constraint-aware performance indicators, and trajectory exports support comparisons within and across communities. Software checks and application examples examine service delivery, electrical constraints, settlement and changing scenarios; a synthetic high-frequency trace replay illustrates how aggregation can conceal short peaks without changing annual energy. Together, these records allow aggregate performance to be interpreted alongside service failures, action reductions and participant-level outcomes.

Comment
34 pages, 14 figures

Closest papers

Nearest neighbours by meaning across the whole index.

AI Data Centers Meet Electrical Grids: A Review of Power Challenges and Coordinated Solutions

eess.SY ·2026-10-06 ·Mariam Mughees, Yuzhuo Li, Yize Chen, Yunwei Ryan Li
survey similarity 0.63
Abstract

Artificial intelligence (AI) workloads are creating large, power-electronic loads whose effects on power systems depend on location, temporal variability, controllability, and interactions with other loads and resources. Annual electricity consumption alone cannot capture these effects. This review examines how AI data centers affect power systems stability, renewable-energy integration, and low-carbon planning by tracing the power-delivery chain from accelerators and workloads through rack converters, uninterruptible power supplies (UPS), storage, and microgrids to the transmission point of interconnection. Reported oscillatory events and multi-gigawatt load transfers highlight how facility responses can amplify disturbances, while programmable workloads and controllable power converters offer opportunities for demand flexibility. Challenges and mitigation strategies are organized across device, rack, facility, and power systems levels, spanning millisecond-to-year timescales. A bandwidth-matching framework relates disturbances to the response capabilities of mitigation resources. The review distinguishes computational energy efficiency from power systems and sustainability outcomes: lower energy consumption per token does not necessarily reduce peak demand, electrical disturbances, or carbon emissions. It examines how coordinated workload scheduling, grid-interactive UPS systems, storage, high-voltage DC distribution, and flexible interconnection can support reliability, efficiency, and decarbonization. Key research needs include dynamic load models, high-bandwidth telemetry, carbon-and grid-aware scheduling, and mechanisms for valuing flexible computational demand.

0.08

User-specified Kelvin-hour budgets within model predictive control for energy-efficient buildings: Simulation and field demonstration

eess.SY ·2026-09-06 ·Jicheng Shi, Colin N. Jones
similarity 0.61
Abstract

For energy-efficient building control, model predictive control (MPC) has been widely proposed to reduce energy use while maintaining prescribed indoor temperature bounds. In practice, MPC implementations may still produce temperature-bound violations because of model mismatch, weather-forecast errors, and softened constraints introduced to preserve feasibility. Existing soft- constrained MPC usually handles this trade-off through slack-weight tuning, so users cannot prescribe a violation-severity budget before operation. This paper develops a Kelvin-hour (Kh)-budget MPC that allows users to specify a running-average budget for temperature-bound violation severity. During operation, the controller uses the realized Kh budget surplus or overspend to update the temperature bounds, providing step-by-step budget feedback. We evaluate the method in two high-fidelity BOPTEST simulation cases and in an occupied residential deployment. In the first one-zone case, prescribed budgets produce clear running-average Kh violation responses across predictors and disturbance settings. At a prescribed budget of 0.005 Kh/step, the controller reduces energy use by 31.9% and Kh violation by 36.2% relative to the built-in default controller. In the second coupled two-zone case, separate zone budgets produce zone-level responses, with 18.9%-20.5% energy reduction and 9.4%-64.3% zone-level Kh violation reduction. In the occupied residential deployment, the running-average Kh violations remain close to or below their prescribed budgets under real sensing, actuation, weather, and occupancy conditions.

0.46

Feeder-Aware Service-Conditioned Flexibility of Grid-Interactive Buildings

eess.SY ·2026-10-22 ·Dafang Zhao, Ittetsu Taniguchi, Takao Onoye
similarity 0.61
Abstract

Grid-interactive buildings can adjust demand, but building-feasible power budgets may differ from accepted feeder-head offers. This study addresses a practical question: to what extent can the adjustable electricity consumption of buildings be translated into deliverable flexibility services while satisfying feeder-head operating requirements? To enable a fair comparison, we adopt the same baseline operating schedule, equipment conditions, and post-service recovery requirements for indoor temperature and battery state of charge (SOC). Flexibility is then evaluated under two settings: one considering only building-level constraints, and the other additionally accounting for feeder-head constraints. We first use a simplified network model with explicit security margins to determine a preliminary amount of flexibility that can be committed. The resulting schedule is then validated using a more detailed network simulation via Modelica. If network losses cause the actual response to deviate from the committed response, the electricity consumption of individual buildings is rescheduled. If the required response still cannot be achieved, the committed flexibility level is reduced. The experiments cover multiple service activation times, regulation directions, and service durations. For comparative purposes, we retain the initial optimization result as the reference estimate of the maximum potentially available flexibility, rather than interpreting the failure of a particular subsequent realization attempt as evidence that a larger flexibility level is inherently infeasible. The results demonstrated that 24.51\% of nonzero flexibility contracts were rejected due to feeder-head constraints, 67.04\% of contracts were accepted with some rescheduling and building redispatch, and only 8.09\% of contracts were accepted without any changes.

0.16

Capacity Credit of Data-Centre Flexibility: The Role of Workload Scheduling and Usable Battery Energy

eess.SY ·2026-11-17 ·Pengyu Ren, Wei Sun, Jiakai Wu, Yifan Wang
similarity 0.61
Abstract

Data centres that offer the same reduction in grid demand can make different contributions to supply adequacy. We estimate the effective load-carrying capability of workload scheduling and on-site batteries by matching expected unserved energy across paired simulations. Longer task deadlines increase capacity credit by giving operators more choice over when to defer and recover work. A fixed evening commitment shifts more work than deadline-based scheduling but delivers a smaller reduction in expected unserved energy. Protected backup reserves leave uninterruptible power supplies with limited capacity credit, while longer discharge durations raise the credit of dedicated batteries at the same response rating. These findings suggest assessing recovery deadlines and dispatchable energy alongside offered demand reductions.

0.20

Robust Scenario-Based Data-Enabled Predictive Control of a Battery Energy Storage System: An Experimental Study

eess.SY math.OC ·2026-10-06 ·Sebastian Zieglmeier, Nikolas Recke, Mathias Hudoba de Badyn
similarity 0.61
Abstract · 8 pages, 5 figures

Battery energy storage systems must respect strict state-of-charge (SOC) limits to prevent overcharge and deep discharge, a task complicated by measurement noise and costly-to-model nonlinear dynamics. Data-enabled predictive control (DeePC) resolves the costly modeling issue by predicting future behavior directly from data. However, its regularization robustifies only the prediction and not the constraints. Scenario-based DeePC (Scenario-DeePC) extends DeePC with the scenario approach, building constraint robustness fully data-driven from observed prediction errors rather than an assumed disturbance distribution. This paper presents the first real-world deployment of Scenario-DeePC, on a grid-connected battery system at the NEST research facility, whose SOC estimate exhibits abrupt, irregular recalibration jumps in addition to ordinary noise. Compared to standard DeePC, Scenario-DeePC achieves comparable tracking performance with substantially fewer constraint violations. Its adaptive scenario buffer further tightens constraint handling automatically, improving robustness to unpredictable recalibration events.

0.17

Impact of Grid-Interactive Data Center Microgrids on Grid Reliability

eess.SY ·2026-11-11 ·Kiran Kumar Challa, Kumarsinh Jhala
hot direction similarity 0.60
Abstract · 5 Pages, 9 Figurs, Conference

Traditional data centers, operating as passive loads with standby backup resources, present significant challenges for grid integration due to their scale, rapid load fluctuations, and limited operational flexibility. This article investigates the transformative potential of grid-interactive data center microgrids, which integrate battery energy storage, on-site generation, and intelligent microgrid controllers to actively support both facility and grid operations. The proposed simulation framework enables the study comparing conventional and grid-interactive architectures under a range of steady-state and contingency scenarios. Results reveal that grid-interactive microgrids can substantially reduce peak grid demand, improve voltage stability, and improve system reliability especially when data center and system load peaks coincide. The findings highlight the critical role of coordinated resource management in enabling the reliable and efficient integration of large data center loads, and provide a practical methodology for assessing their system-level impacts.

0.26

Minimizing Grid Interconnection Capacity Requirements for AI Data Centers: A Developer-Side Planning Framework with Onsite Resources and Workload Flexibility

eess.SY ·2026-08-29 ·Hassan Zahid Butt, Rida Fatima, Xingpeng Li
similarity 0.60
Abstract

Securing grid interconnection capacity has become a bottleneck for AI data center projects and can take longer than constructing the facilities themselves. This mismatch can delay deployment for years, making early interconnection planning essential. This paper develops ICP-AI, an interconnection capacity planning framework from a data center developer's perspective. The framework minimizes grid import capacity under a prescribed onsite investment budget while jointly sizing photovoltaic (PV) and battery energy storage system (BESS) resources and scheduling deadline constrained workload flexibility. A secondary refinement fixes the minimum grid capacity and selects the minimum-investment PV-BESS portfolio among solutions that achieve that capacity. The framework is evaluated using monthly composite stress profiles across varying temporal assumptions, load shapes, flexible load fractions, and deferral windows. Results show that interconnection capacity reduction depends strongly on the planning environment: at a $100M budget, it is about 6% for the high load factor baseline, exceeds 10% under monthly average solar availability, and reaches 13.3% for a more diurnal load. At a $10M budget, 5% flexible load with a 1 h workload deferral window reduces BESS capacity from 15.30 to 4.87 MWh while increasing capacity reduction from 4.43% to 4.84%. To test sensitivity to temporal compression, the model is also solved over the full 8,760 h chronology, which preserves the main capacity and flexibility trends. Overall, ICP-AI quantifies the interconnection capacity and infrastructure substitution value of workload flexibility, providing an investment-interconnection frontier to support capital allocation and early project planning in constrained grid environments.

0.30

Artificial Intelligence for Energy Optimization in Data Centers

cs.AI cs.LG ·2026-09-03 ·Mohammed Basharath Ullah, Summaiya Unnisa Begum, Mohammed Nadeem Ullah
code/data similarity 0.60
Abstract · 11 pages, 6 figures, 7 tables

Data centers are increasingly optimized by artificial intelligence and, at the same time, increasingly loaded by it. The literature treats these as two unrelated problems: control studies model workload as an exogenous arrival process, while sustainability studies model infrastructure as a fixed multiplier. We screen roughly 194 papers retrieved through a documented protocol, code 63 of them, and report what the coding shows. Of 28 primary control-oriented studies, 18 are validated in simulation alone and 5 reach physical hardware or a production facility; none account for water withdrawal, and none account for embodied carbon. Reported savings intervals across four technique families overlap almost completely, which means the field cannot presently rank its own methods. Ten recurring gaps are scored for consequence and tractability, and we set out CLEAR-DC, a framework coupling a control-policy branch to a workload-demand branch through an explicit elasticity term, reads out net rather than direct benefit, and emits a schema-conformant record covering energy, carbon, water, embodied share and validation venue. The framework is an architectural and methodological proposal, not a trained system; the contribution we defend empirically is the corpus analysis and the reporting schema derived from it. Coding sheet, derived statistics and all result artifacts: https://github.com/Kimalice/AI-for-Energy-Optimization-in-Data-Centers-Closing-the-Optimizer-Load-Loop

0.45