CS Paper Radar

Analysis of trade-offs in urban heat mitigation using a Bayesian Optimization framework for an urban canopy layer model

Rebekka Walter, Johanna Gelhaus, David Anton, Henning Wessles, Stephan Weber

cs.CE physics.ao-ph ·submitted 2026-09-22 10:00 UTC · v1

Abstract

To mitigate the challenges of climate change and intensifying heat stress in urban areas, local adaptation strategies are discussed and introduced in cities worldwide. To understand processes and potential trade-offs of these strategies a Bayesian optimization and surrogate modeling framework was employed to investigate urban parameter ranges of heat mitigation strategies with focus on three thermal metrics: daytime air temperature, Universal Thermal Climate Index (UTCI), and nighttime air temperature. Based on an urban street canyon configuration, it was shown that heat mitigation measures that reduce daytime air temperature and UTCI are often associated with higher nighttime temperatures. This results in a curved Pareto front that reflects the trade-off between daytime and nighttime thermal comfort. Under identical forcing conditions, different urban configurations, varying in geometry, vegetation, and surface characteristics, are shown to alter peak canyon air temperature by up to 5.2~$^\circ$C during the day and 2.6~$^\circ$C at night, while UTCI varies by up to 7.9~$^\circ$C, demonstrating that favorable urban configurations can substantially mitigate microclimatic heat stress. These findings suggest that combining multi-objective Bayesian optimization and surrogate modeling can help bridge the gap between computationally intensive climate simulations and practical decision-making in urban planning. An interactive visualization tool was developed to explore these trade-offs, making the often opposing relationships between urban parameters and the three thermal metrics directly accessible to planners.

Closest papers

Nearest neighbours by meaning across the whole index.

UHI-Bench: Benchmarking Dual-Source Urban Heat Island Modeling Across Cities in Diverse Climate Regimes

cs.LG ·2026-08-24 ·Wanyun Ling, Chenxi Liu, Yi Xie, Aopu Xu, Zhuoqi Zeng +1 more
benchmark similarity 0.58
Abstract · 24 pages, 11 figures, 19 tables

Urban heat islands (UHIs) are intensifying under climate change, exacerbating thermal exposure risks. Their two primary observations, land surface temperature UHI (LST-UHI) and near-surface air temperature UHI (AirT-UHI), capture physically distinct aspects of urban heat. However, most studies rely on a single source, and substituting one for the other can substantially bias the magnitude and spatial variability of human heat exposure. Accurate UHI modeling also requires dynamic meteorological drivers and static urban morphology features, but spatiotemporal incompatibilities hinder their alignment. Cloud gaps in LST observations and sparse AirT station networks further limit dual-source UHI modeling, motivating cross-city transfer across diverse climates. To bridge these gaps, we introduce UHI-Bench, the first UHI benchmark for dual-source UHI modeling that integrates dynamic and static environmental context. Following a unified signal, mechanism, and transfer framework, it evaluates over 20 baselines from four model families on five tasks across 20 cities and nine Köppen climate classes. Results show that no model is uniformly best, although foundation models remain consistently competitive and stable. Environmental covariates generally improve performance, but their utility varies across sources and tasks. Cross-city transferability is better explained by overlap in UHI regimes than by climate-zone similarity. With the dataset and standardized pipeline, our work provides practical guidance for urban heat modeling, promotes climate data equity, and supports future advances in climate research.

0.29

Less is more: error-distance scaling relation for data-efficient kilometer-scale downscaling of extreme heat

cs.LG physics.ao-ph ·2026-09-30 ·Ahmed Marey, Henry Lu, Abhishek Gaur, Sherif Goubran, Malek Aloui +4 more
similarity 0.54
Abstract

Extreme heat is where urban adaptation needs kilometer-scale data the most, but the simulations training a downscaler can cost more than they save, and how much is needed has not been identified. We measured it with CASPER, a U-Net with a structure-preserving loss downscaling 32 km reanalysis to 1 km temperature, humidity and wind, across 24 configurations of one to eight months. Held-out error grows linearly with climatological distance to the training data, RMSE = 0.83 + 2.95 d, explaining 90% of its variance against 7% for volume and predicting unseen months in advance. On held-out extreme summer weeks CASPER preserves the fine-scale structure and cross-variable physics that matched-budget baselines degrade, and matches station observations during documented heat waves to within 1.8 K. Transfer to a new region degrades geographically; 11 days of local simulation cuts Vancouver's held-out error from 3.8 to 1.3 K. Training periods should span the target climate: the same accuracy for four times less simulation, putting kilometer-scale downscaling of extreme heat within reach of groups without large computing facilities.

0.24

Adjacent Heat Transfer Effects Can Bias Savings Estimates When Controlling Only Part of a Multi-Zone Building

eess.SY ·2026-11-12 ·Arash J. Khabbazi, Kevin J. Kircher
publishedtheory similarity 0.50
Abstract · 10 pages. Accepted at the 2027 ASHRAE Winter Conference

Field demonstrations of advanced heating, ventilation, and air-conditioning control often operate a few thermal zones within a larger building and report savings for those zones alone. A recent theorem showed that this practice overestimates whole-building savings, because heat drawn from the neighboring zones is paid for by their equipment and is not counted. The error grows with the thermal conductance between the controlled and uncontrolled zones, with how much colder the controlled zones run over the test, and with the price of the heat their neighbors supply. For one controlled zone with one neighbor, a single thermal price, and slowly changing prices, the relative error reduces to the ratio of two conductances, a screening number that can be evaluated from the two conductances before a demonstration begins. This paper tests how far that reduction can be taken. A two-story house with one thermal zone per floor is simulated over a 90-day heating season in West Lafayette, Indiana, with receding-horizon model predictive control on the first floor and setpoint control on the second, under four combinations of electricity tariff (time-of-use or flat) and heating plant (heat pump or electric resistance). The exact correction from the theorem recovers the true savings in every case, and the full theorem, evaluated from the controlled zone's temperatures, the prices, and the building parameters, reproduces the measured relative error in every case. The conductance ratio bounds that error from above in all four cases, tightly under a flat tariff, within 3%, and loosely under a time-of-use tariff, where most of the controller's savings come from shifting load through the thermal mass rather than from lowering the temperature.

0.30

Optimizing Geoengineering Interventions Using Differentiable Climate Models

cs.AI physics.ao-phmath.OCnlin.CD ·2026-09-11 ·Pulkit Dubey, Dorian S. Abbot, Ashesh Chattopadhyay
similarity 0.50
Abstract

The deployment of a geoengineering program to cool Earth's climate may be imminent. It is crucial that tools be developed to ensure that such a program would achieve its objectives while minimizing disruption. Here we exploit recently developed differentiable atmospheric models to demonstrate a novel geoengineering control strategy. In the differentiable primitive-equation atmospheric model JAX-GCM we impose a uniform $+4$\,K ocean warming and ask what pattern of sea-surface temperature cooling -- in five ocean-masked zonal bands of prescribed SST forcings whose amplitudes are free -- returns land near-surface air temperature closest to the model's own unwarmed climatology. This idealized set-up represents a cooling pattern that could be delivered physically either by marine cloud brightening or stratospheric aerosol injection. Gradients through chaotic dynamics decorrelate from the true sensitivity beyond the Lyapunov horizon, so we optimize greedily over segments of 8 to 14 days, following receding-horizon control. The learned strategy removes $92.3 \pm 0.4\%$ of the realized land warming across a ten-member ensemble of two-year rollouts, and a three-year run sustains it. If we use the spatial pattern of land temperature as the optimization objective, the distributions of precipitation, evaporation, and specific humidity over land are restored as well, even though they are not included in the objective function. The learned strategy from JAX-GCM replayed in the AI emulators LUCIE and NeuralGCM without re-optimization is successful, suggesting robustness. These promising results demonstrate a strategy for designing optimal climate interventions that can be applied broadly for geoengineering scenarios under consideration.

0.32

ADAPT: Physics-Aware Diffusion-based World Models for Adaptive Predictive Transferable HVAC Control

cs.AI ·2026-08-20 ·Xu Yang, Kailai Sun, Dianyu Zhong, Qianchuan Zhao
similarity 0.50
Abstract

Buildings account for roughly one-third of global energy consumption and CO$_2$ emissions. Optimizing indoor climate systems plays a critical role for urban climate mitigation aligned with UN Sustainable Development Goals 11 and 13. However, indoor delayed thermodynamic responses and partial observability severely hinder existing methods, which are primarily limited by implicit thermal inertia, occupancy dynamic prediction, and cumulative prediction errors, especially for out-of-distribution environments. In practice, these challenges are further exacerbated by the high cost and privacy burden of dense indoor sensing, forcing operators to collect only limited data in a single operating regime while expecting controllers to generalize reliably across unseen seasons and climate regions. To address this problem, we propose ADAPT, a physics-aware conditional diffusion indoor environmental world model for HVAC control. The model predicts a short-horizon held-action thermal baseline to capture the latent thermal inertia of the buildings. The diffusion backbone utilizes the robustness of generative models, while a learnable multi-zone heat-balance regularizer constrains generated trajectories to satisfy transferable building thermodynamics without requiring known building geometry or manually calibrated thermal parameters. A credit assignment is then design for the downstream reinforcement learning. Extensive experiments on SemibuildingSim and Sinergym demonstrate that ADAPT reduces HVAC energy consumption by 7.3\% and occupant discomfort by 30.2\% compared with state-of-the-art baselines under IID control. Under OOD control scenarios spanning unseen seasons and climate regions, ADAPT maintains robust performance with only marginal degradation relative to its IID performance, substantially outperforming existing methods in transfer robustness.

0.23

The hidden solar cost of urban unfamiliarity

cs.CY ·2026-11-11 ·Lijia Liu, Yimeng Song
similarity 0.50
Abstract · 75 pages, 5 main figures. Includes 63 pages of Supplementary Material

Unfamiliar walkers may follow the shortest route and miss nearby shade, indoor passages and multilevel connections. We define the resulting hidden solar cost as the direct-sun exposure avoidable through shade-informed routing without substantial detours. We developed a time-specific three-dimensional model of Hong Kong Island that combines indoor and outdoor walking networks with building geometry, vegetation mapped by light detection and ranging (LiDAR), and solar position. For 500 modelled journeys, we compared shortest and shade-informed routes at four daytime snapshots and five extra-distance limits. At noon, shade-informed routes reduced modelled direct-sun exposure by 13.5% relative to shortest routes under a 10% extra-distance limit. Route length increased by 2.85% on average. A 5% extra-distance limit delivered 77% of the reduction obtained at 10%. In a controlled comparison, outdoor shade information accounted for 86% of the reduction and indoor-protection information for 14%. Removing multilevel connections left only 191 of 500 journeys feasible within the original route-length limit. These route comparisons identify an avoidable solar cost when existing protection is missing from the information used to choose a route. Making protected routes visible and preserving their connections can reduce sun exposure without large detours.

0.41

Mapping urban heat from citizen-collected data: a scalable Gaussian process approach to correcting for preferential sampling

cs.LG stat.AP ·2026-09-21 ·Ellie K. Kim, Zachary D. Calhoun, Michael H. Bergin, David E. Carlson
similarity 0.50
Abstract

The urban heat island (UHI) effect amplifies heat stress in cities, increasing heat-related illness, mortality, sleep disruption, and energy demand. Because UHI intensity varies at neighborhood scales, intra-city temperature mapping is essential for assessing public health impacts, yet existing monitoring networks are sparse. Crowdsourced weather stations provide dense, hourly observations but suffer from noise and systematic biases, including preferential sampling driven by where residents install sensors. We introduce two scalable Gaussian process frameworks which adjust for preferential sampling and enable statewide, high-resolution temperature prediction. The first integrates sampling correction directly within a sparse variational Gaussian process (SVGPR+PS). The second uses a two-stage estimator involving a log-Gaussian Cox process (LGCP+GP) that estimates the sampling intensity field and incorporates it into temperature prediction. Both methods rely on inducing-point approximations and variational inference to scale beyond traditional Gaussian processes. Applied to approximately 10,000 citizen stations across North Carolina, the models generate hourly temperature fields within minutes. Validation against independent urban heat campaign data shows that the preferential sampling correction improves predictive performance, increasing average afternoon correlations across four cities from 0.26 to 0.43. This scalable framework enables neighborhood-level UHI assessment and supports studies of heat exposure disparities statewide.

0.25

Steering Diffusion Priors with Sparse Observations for High-Resolution Temperature Downscaling

cs.LG physics.ao-ph ·2026-09-08 ·Anirudh Avireddy, Manmeet Singh, Shivanshi Singh, Ayush Raj, Saptarishi Dhanuka +2 more
similarity 0.48
Abstract

Local heatwave hazard depends on fine-scale air temperature, but ground stations are sparse and reanalysis products such as ERA5 cannot resolve the terrain and land-surface contrasts that shape real heat exposure. We present a conditional diffusion emulator for high-resolution 2-m temperature downscaling, conditioned on static geography, a training climatology, exact-time ERA5 temperature, and solar and temporal features, guided at inference by score-based data assimilation (SDA): a differentiable Gaussian observation likelihood steers the diffusion score toward sparse revealed temperature observations without any retraining. On a controlled 32-case synthetic-grid protocol over AORC, guidance improves hidden-cell reconstruction over both ERA5 and a strong observation-proximal nearest-neighbor baseline once observation density reaches 1\% (RMSE 0.318 vs.\ 0.431~K, winning all 32 cases), while sparser regimes still favor direct interpolation. We further map the full guidance-strength landscape across three observation densities, showing that the optimal strength shifts systematically with density and that over-guiding causes sharp, predictable degradation -- giving a concrete operating recipe rather than a single untuned setting. The resulting fields are intended as a temperature layer for downstream heatwave-hazard products such as threshold exceedance and cumulative heat-burden. The present evidence is a controlled synthetic-grid validation; station-network and held-out-year evaluations are the next steps toward deployment.

0.18