CS Paper Radar

Style-Driven Data Synthesis and Degradation-Aware Enhancement for Ultrasound Image Restoration

Yu-Kai Wang, Chun-Xin Tan, Manh-Hung Nguyen, Ching-Chun Huang

cs.CV ·submitted 2026-09-28 13:17 UTC · v1
code/dataunusual

Abstract

Low-cost handheld ultrasound devices can be widely deployed compared to professional hospital ultrasound machines. However, their images suffer from compound degradation that can mislead clinical judgment. Motivated by this observation, mapping handheld low-quality (LQ) to hospital high-quality (HQ) images has been considered a valuable research question. Conventionally, the mapping requires pixel-aligned LQ-HQ pairs. This requirement is unsatisfactory in practical scenarios because real scans at different times are never pixel-aligned. This paper addresses the challenge with a two-stage framework. The first stage generates pixel-aligned LQ-HQ datasets, and the second stage trains an enhancement model that improves LQ images. The first stage trains a cycle-consistent style-transfer model on unaligned real LQ-HQ pairs to learn a HQ-to-LQ model. Then, the model transforms real HQ images into pixel-aligned LQ images. Based on the dataset generated by the first stage, the second stage uses the Dual Degradation-Guided (DDG) Low-Rank Adaptation (LoRA) method to fine-tune an LQ-to-HQ model based on aligned pairs. In this stage, the model is based on the well known PiSA-SR framework but inserts a degradation-conditioned correction matrix. Experimental results on the USenhance2023 dataset show that the FID metric is improved by 16.7% over the strongest baseline while other metrics indicate that our enhanced outputs are well aligned with the real HQ distribution. The source code of our method is available at https://github.com/Jason0411202/DDG_LoRA.

Closest papers

Nearest neighbours by meaning across the whole index.

DAP-MR: Degradation-Aware Prompt-Magnitude Routing for Real-World Ultrasound Super-Resolution

cs.CV ·2026-11-17 ·Ngoc-Hoang-Lam Le, Thi-An Le, Dinh-Hung Le, Manh-Hung Nguyen, Kai-Lung Hua +1 more
similarity 0.59
Abstract

When super-resolution models designed for natural images are used on ultrasound scans, relying on semantic text prompts can lead to unreliable results. The tags these models generate often do not match the actual restoration needs, and specialized medical terms may be misunderstood by general-purpose text encoders. Instead, prompts focused on common image degradations are more directly useful for guiding restoration. However, using a single prompt to describe both the type and severity of image degradation can entangle these factors, making it hard for the model to know how strong the degradation is. To address this limitation, we introduce Degradation-Aware Prompt--Magnitude Routing (DAP-MR). Each degradation type is represented by a dedicated token initialized from the contextualized EOS embedding of a degradation-oriented prompt and subsequently adapted during ultrasound SR training. A separate magnitude router predicts a continuous, input-dependent magnitude that modulates the corresponding token. Thus, language provides a degradation-aware initialization for what should be restored, while magnitude routing supplies an explicit signal for how strongly it should influence restoration. DAP-MR can be added to both one-step and multi-step diffusion super-resolution frameworks without changing their core structures. Our experiments--on synthetic datasets with both in-domain and under anatomical-domain shift, as well as unpaired real-world ultrasound data--show that DAP-MR delivers better restoration quality and generalizes more consistently across different domains.

0.24

Open-H-RF: A Large-Scale Ultrasound Raw Channel Dataset Initiative

eess.SP ·2026-10-09 ·T. S. W. Stevens, S. W. Penninga, W. L. van Nierop, O. Nolan, F. Duelmer +181 more
dataset similarity 0.57
Abstract · Preprint: 15 pages, 15 figures, 3 tables. Dataset (v1.0): https://open-h.github.io/Open-H-RF

Medical ultrasound is a widely accessible, real-time imaging modality, yet progress in data-driven ultrasound research is constrained by the scarcity of large, open collections of raw channel data. Existing public datasets are predominantly based on reconstructed images, while the smaller number of open raw channel datasets is generally specialized to individual reconstruction or imaging tasks, limiting the development of general-purpose methods and foundation models that operate directly on ultrasound signals. While interpretive tasks can be performed on reconstructed images, many of the key technical challenges in ultrasound imaging, such as aberration correction and reverberation reduction, require the raw channel data itself. We introduce Open-H-RF, a community-driven open dataset initiative comprising approximately 40 TB of medical ultrasound raw channel data in 19,332 acquisitions, contributed by 38 institutions across academia and industry, spanning in-vivo, phantom, and simulated data. Each dataset is annotated with a number of supported tasks, ranging from generalized reconstruction, speed-of-sound estimation, and aberration correction to blood flow imaging, motion estimation, quantitative ultrasound, and image interpretation. Open-H-RF provides a unified, self-contained data format that captures raw channel data together with the acquisition, probe, metadata, and reconstruction information required for reproducible processing across scanners and acquisition schemes. The corpus is publicly hosted under a permissive CC BY 4.0 license and can be streamed programmatically and selectively at scale. By bringing heterogeneous ultrasound data into a common representation, backed by modern data infrastructure, Open-H-RF lowers the barrier to working with raw channel data and aims to open medical ultrasound research to new communities. See https://open-h.github.io/Open-H-RF.

0.47

UltraPIPS: Improving model perception in B-mode ultrasound with foundation models

cs.CV eess.IV ·2026-08-26 ·Tal Grutman, Tali Ilovitsh
publishedcode/datahot direction similarity 0.57
Abstract · MICCAI ASMUS 2026

In medical imaging, it is common to use learned perceptual image patch similarity (LPIPS) to compare images semantically in feature space. Although backbones pretrained on natural images are widely used for LPIPS computation, B-mode ultrasound images possess distinct speckle patterns and acoustic-specific image statistics that are fundamentally different from natural images and even from other images in radiology. Consequently, we propose that domain-specific models are needed to measure perceptual similarity in ultrasound data, a finding which is not necessarily the case for other imaging modalities. We compare LPIPS metrics across downstream tasks like classification, segmentation and reconstruction using natural image, medical generalist and ultrasound backbone models and show that selection of LPIPS backbone is a non-trivial design choice. In particular, the ultrasound backbone models were more correlated with downstream performance of supervised models than classical and natural image models, and optimization of the LPIPS loss with an ultrasound backbone achieved a strong balance between reconstruction quality and realism. Our code is available at https://github.com/talg2324/UltraPIPS and introduces the UltraPIPS library, a set of LPIPS metrics based on the open-source foundation models analyzed in this paper.

0.51

Null-Space Diffusion Restoration with Adaptive Uncertainty-Guided Fusion for Ultrasound Speckle Reduction

cs.CV ·2026-08-30 ·Juneyong Lee, Jaeyoung Choi
publishedbenchmarkcode/data similarity 0.56
Abstract · 14 pages, 4 figures, 5 tables. Accepted for publication in IEEE Access

Ultrasound B-mode imaging commonly suffers from speckle noise and artifacts, requiring a delicate balance between contrast, resolution, and preservation of anatomical structures. Although recently developed despeckling methods have achieved some progress, supervised learning approaches remain fundamentally limited by the ground truth paradox, which arises from the absence of noise-free, ground truth reference images in in vivo scenarios. Existing unsupervised diffusion-based methods typically enforce data consistency directly in the nonlinear log-compressed domain, which can disproportionately amplify background artifacts when mapped back to the envelope domain. To overcome these limitations, we propose an uncertainty-guided null-space diffusion (UGNS) framework, a novel label-free solution that enforces consistency correction on a stabilized positive-envelope proxy obtained via inverse log compression. The proposed UGNS introduces several technical novelties: (a) extraction of a structural prior in the stabilized envelope domain to produce a robust signal envelope that preserves anatomical structure, (b) development of an adaptive range-null reconstruction mechanism that uses an adaptive weight mask to preserve tissue regions via range-space projection, and (c) introduction of uncertainty-guided fusion in an adaptive way to mitigate sampling variability. Extensive and comparative experiments were conducted using the PICMUS benchmark and in vivo datasets. The results demonstrate that UGNS achieves competitive generalized contrast-to-noise ratio (gCNR) values across diverse datasets. In addition, it is successfully validated that UGNS effectively suppresses speckle noise while preserving fine spatial resolution. Code is available at https://github.com/yousirong/UGNS.git.

0.60

Cross-Device Transfer of a Hospital-Trained Fetal Head Circumference Model to a Low-Cost Handheld Ultrasound Probe

eess.IV ·2026-10-28 ·Patrick Gao, Lara Hart, Ken Sullivan
benchmark similarity 0.56
Abstract · 24 pages, 5 figures, 4 tables

Automated fetal head circumference (HC) measurement reaches near-expert accuracy on the HC18 benchmark, but published models are trained and evaluated on hospital-grade equipment. We quantify what happens when such a model is carried to a low-cost handheld probe. A lightweight segmentation network (CSM, 0.13M parameters) was trained on HC18 across five independent runs and applied without modification to images from a $1,350 handheld probe (SonoQue C3), acquired at the same visit as the reference hospital scan in 18 patients. In-domain accuracy was 2.34 +/- 0.43 mm; on handheld images the same model gave 16.12 mm against the hospital record, a 6.9-fold degradation. Input preprocessing, a choice rarely reported, accounted for about a third of that gap: direct resizing gave 49.45 mm against 16.12 mm for an aspect-preserving pipeline. A leave-one-out data-efficiency curve showed that fine-tuning on two images significantly worsened accuracy, and that from four images upward error fell by 0.75 mm per doubling of the local dataset (p = 0.0045), although no training-set size up to 27 images significantly improved on the unmodified model. Much of the residual gap belongs to the reference rather than the model: scored against a manual tracing of the same image the model was already within 10.48 mm, and its disagreement with sonographer calipers on the same frame was a near-constant offset, negative in 10 of 10 cases. A single calibration constant estimated leave-one-out reduced that disagreement from 8.12 mm to 3.49 mm, reaching the intraobserver reproducibility reported for experienced sonographers, but did not improve agreement with the hospital record. Cross-device evaluations should therefore report the input preprocessing used and characterise the precision of their reference standard.

0.21

AgentCT: A Vision-Language Agent for Universal CT Imaging

cs.CV ·2026-11-08 ·Zhihao Chen, Qi Gao, Chuang Niu, Qiegen Liu, Yi Zhang +1 more
code/datahot direction similarity 0.55
Abstract · 14 pages, 5 figures

Computed tomography (CT) restoration methods often use a single network for low-dose CT (LDCT), sparse-view CT (SVCT), and metal artifact reduction (MAR), despite the distinct physics of these degradations. We propose AgentCT, a vision-language agent that identifies the degradation and routes images to task-specific restoration models. A LoRA-adapted Qwen3-VL-4B controller predicts degradation type and severity, selects a specialist, and reassesses the restored image. The LDCT specialist uses an image-domain diffusion model, whereas the SVCT and MAR specialists combine projection-domain correction, data consistency, differentiable filtered back-projection, and image refinement. We evaluated the controller and specialists separately on patient-disjoint Mayo 2020 abdominal CT data across three severity levels for each degradation. The controller achieved 95.7% accuracy for degradation type and 93.9% for severity, with a 100% JSON parse rate. Using ground-truth degradation labels for routing, AgentCT achieved an overall PSNR/SSIM of 46.18 dB/0.984, compared with 44.93 dB/0.976 for AMIR and 44.29 dB/0.979 for TAMP, and attained the highest PSNR in all nine settings. For SVCT, its dual-domain specialist achieved 46.04 dB with 4.2 million parameters, compared with 44.43 dB for single-task AMIR and 43.57 dB for all-in-one AMIR with 23.5 million parameters. These results support degradation-specific CT restoration with controller-based model selection; evaluation under automatic routing and on independent clinical data remains necessary. Code is available at https://github.com/hao1635/AgentCT.

0.42

Diffusion Plug-in Priors for Self-Supervised Ultrasound Video Restoration

cs.CV ·2026-11-03 ·Chu Chen, Mingduo He, Yining Li, Yinhao Wu, Wei Tang +4 more
code/data similarity 0.55
Abstract

Ultrasound videos are limited by hardware-constrained spatial resolution and signal-dependent speckle, while paired low- and high-resolution acquisitions for supervised restoration are rarely available. We aim to jointly super-resolve and despeckle ultrasound videos without paired training data or network retraining. We propose UltraDiff, which uses a frozen pre-trained diffusion model (DM) as a plug-in prior and restores each frame by optimizing the latent seed of the DM sampler under a range-constrained maximum a posteriori formulation. We derive a speckle-aware data-fidelity term from a Rayleigh scale-family model and characterize its relative-residual and variance-adaptive weighting properties. We further introduce a stabilized fidelity that is bounded below and strictly convex in log intensity for positive observations in its unclamped form. A total-variation regularizer complements the DM prior, and a temporal seed update warm-starts each frame from the optimized seed of its predecessor. On EchoNet-LVH videos with simulated speckle and additive noise, UltraDiff with a natural-image prior improves PSNR by 1.24\,dB over the strongest baseline, and ultrasound-related priors improve it further. On real clinical echocardiography videos, UltraDiff reduces the mean absolute error of zero-shot ejection fraction (EF) prediction from 7.31 to 6.37 EF points relative to DUP, the strongest baseline. Combining a speckle-aware fidelity with frozen diffusion priors enables ground-truth-free ultrasound video restoration that benefits downstream measurement. UltraDiff needs neither paired data nor retraining and is not tied to a specific diffusion checkpoint. Code associated with this work will be made publicly available upon acceptance.

0.21

Dual Co-Train: Cross-Dataset Ultrasound Tongue Segmentation Under Extreme Data Scarcity

cs.CV cs.AI ·2026-08-18 ·Alisher Myrgyyassov, Zhen Song, Bruce Xiao Wang, Yu Sun, Min Ney Wong +2 more
similarity 0.53
Abstract

Ultrasound tongue contour segmentation remains challenging under cross-dataset domain shift, where limited annotations, probe variability, and acquisition noise often degrade model generalization. We present a source-free domain adaptation framework for robust ultrasound tongue segmentation built on a lightweight UltraUNet backbone. Starting from a checkpoint pretrained on only five labeled source images, simulating an underfitted constrained source model, the proposed method adapts to a fully-unlabeled target domain by iteratively refining pseudo-labels, filtering unreliable masks with a contour-based quality-control module, and generating target-style synthetic image-mask pairs through a segmentation-guided conditional GAN. The student model is then trained on a mixture of clean pseudo-labeled target images, noisy pseudo-labels with consistency regularization, and synthetic samples, enabling closed-loop adaptation without access to source data. We evaluate the method on 12 source-target transfer pairs across eight ultrasound tongue imaging datasets, and conduct source-size scaling experiments and ablation studies. Across all comparisons, the proposed framework improves segmentation overlap and contour accuracy over the baselines, including supervised ones. These results suggest that task-specific pseudo-label refinement and synthetic target-style augmentation can substantially improve source-free adaptation for ultrasound tongue imaging.

0.21