CS Paper Radar

Reliability-Gated Fusion of Consumer Head and Foot IMUs for Lower-Body 3D Pose

Zhilin Guo, Boqiao Zhang, Oszkár Urbán, Josef Bengtson, Hakan Aktas, Wenzhao Li, Siyu Hong, Kyle Fogarty, Chenliang Zhou, Ali Senguel, Cengiz Oztireli

cs.CV cs.HC ·submitted 2026-09-28 17:59 UTC · v1
benchmarkcode/data

Abstract

Sparse inertial pose estimation promises camera-free motion capture from consumer devices, but consumer sensors are unreliable: firmware-fused orientations are biased, mounting varies between sessions, and streams drift or drop out. On a new 35-take single-subject benchmark pairing an earbud head inertial measurement unit (IMU) with two smart-insole foot IMUs (SAM-3D-Body pseudo-ground-truth labels), we show the reliability problem is channel-level: a channel ablation isolates foot acceleration as the most informative input (66.6 mm vs. 79.0 mm head-only) and the firmware-fused foot orientation as the liability that destroys the gain. We therefore let the model learn how much to trust each channel of each stream: one temporal gate per stream per channel block, trained with an auxiliary reliability objective on synthetically corrupted pretraining data. The channel-gated model is the most accurate of our learned fusion arms on clean data (69.4 mm vs. 83.7 static, 86.6 ungated) and under every simulated fault (bias in training; drift, dropout eval-only); its gates suppress the natively biased foot-orientation channels on clean real data without test-time supervision and flag dropout bursts at 0.92-0.999 AUROC. Two contrasts: dropping a channel known a priori to fail is flat across foot faults but collapses when an unanticipated stream fails (head dropout: 92.9 vs. 79.3 mm); and a fine-tuned HMD-Poser is more accurate on clean data (64.4 mm) and nominally under drift, with no significant paired difference under bias or dropout, but a larger worst-case degradation from clean (+16.1 vs. +3.5 mm, single seed). Learning to gate reliability instead of sensor count is the lever for deployable sparse inertial capture. Code is available at https://github.com/ZhilinGuo/reliability-gated-imu-fusion.

Comment
10 pages, 4 figures, 3 tables. Code: https://github.com/ZhilinGuo/reliability-gated-imu-fusion

Closest papers

Nearest neighbours by meaning across the whole index.

One Sensor, Whole Body - 3D Body Pose from a Single Consumer Earbud IMU

cs.CV cs.HC ·2026-09-28 ·Zhilin Guo, Boqiao Zhang, Oszkár Urbán, Josef Bengtson, Hakan Aktas +6 more
benchmarkcode/data similarity 0.72
Abstract · 5 pages, 2 figures, 2 tables. Accepted at the 6th International Workshop on Human-centric Multimedia Analysis (HUMA '26), ACM Multimedia 202…

Consumer earbuds already stream inertial motion data from the head, one of the most widely worn sensor locations on the body. We ask how much of the 3D body pose a single such head IMU can recover, and whether adding more consumer sensors actually helps. We build a multimodal capture pipeline that records four-view RGB-D video together with an AirPods head IMU and two Striv insole IMUs, synchronize the streams post-hoc, and generate pseudo-ground-truth with SAM 3D Body, yielding a 35-take single-subject benchmark spanning gait, turning, vertical, everyday, and clinically inspired motions. Adapting two recurrent model families (IMUPoser and MobilePoser), we show that one head IMU recovers lower-body pose at 79.0 mm rigid-MPJPE and per-foot ground contact at 0.809 macro-F1, and that a causal variant retains most of this accuracy at streaming latency. In paired per-take significance tests across both families, adding the consumer foot IMUs never significantly improves pose and significantly degrades it in two of four model-split combinations; a mounting-bias probe and feet-only ablation identify insole orientation quality, not foot placement, as the mechanism. Extending the output to a 20-joint full-body skeleton maps the boundary: gross distal-arm motion is partially recoverable from the head alone, proximal upper-body pose is not, and staged fine-tuning recovers the leg accuracy that naive joint training sacrifices to multi-task dilution. For learned pose from consumer wearables, sensor reliability, not sensor count, is the binding constraint here. For the devices tested, the earbud is its sweet spot. Code is available at https://github.com/ZhilinGuo/one-sensor-whole-body.

0.62

Robust Real-Time Monocular Human Pose Estimation with Insole-Based Sensor Fusion

cs.CV cs.AI ·2026-10-14 ·Liang Yu, Tao Zhu, Xiangqing Lu, Wenjian Luo, Liming Chen
similarity 0.65
Abstract

Real-time monocular human pose estimation is an important sensing component for human-centered intelligent systems. While recent camera-based methods have achieved impressive accuracy, fundamental challenges persist, particularly when visual observations are incomplete, such as during lower-body occlusion or short out-of-frame intervals. In these challenging but common scenarios, vision-only systems often struggle to reconstruct physically plausible lower-limb motion and reliable foot-ground contact. Due to the highly unobtrusive and wearable nature of smart insoles, this paper investigates whether simple plantar pressure and acceleration sensors can effectively resolve these visually induced limitations. To systematically investigate this, we first collect a synchronized multimodal dataset and then propose a part-decoupled temporal fusion framework. The proposed model fuses foot-sensing features into the lower-body branch to compensate for incomplete visual evidence, while a lightweight coordinator exchanges information between the upper- and lower-body temporal representations to maintain whole-body consistency. The framework is evaluated with three representative real-time visual backbones based on 2D keypoints, 3D landmarks, and SMPL-based human mesh recovery. We evaluate our framework on three representative real-time visual backbones. Quantitative experiments demonstrate that incorporating simple foot sensors consistently improves pose accuracy, motion smoothness, and gait-related measurements over vision-only baselines, with the most significant gains observed under occlusion and short visual-dropout conditions. Ultimately, our results demonstrate that unobtrusive foot sensing provides vital and complementary physical observability when camera observations are temporarily unavailable.

0.20

FOCUS: Foot Observation Confidence for Robust Humanoid Proprioceptive Odometry

cs.RO ·2026-09-02 ·Kaixin Feng, Angsong Li, Shaopeng Zhang, Enyu Li, Peiwen Lin +3 more
hot direction similarity 0.65
Abstract · 8pages,6figures

Foot forward kinematics (FK) is widely used to improve proprioceptive legged odometry by providing reliable velocity constraints during foot support. Existing contact-aided estimators generally rely on binary contact decisions to determine whether the FK measurements of an entire foot should be trusted. However, contact does not necessarily imply FK reliability. Dynamic locomotion often involves partial support, toe dragging, and foot slip, causing binary contact decisions to accumulate significant drift over long trajectories. To address this limitation, we propose FOCUS (Foot Observation Confidence from Unannotated Simulation), which predicts a continuous FK reliability weight for each foot instead of estimating binary foot contact. Rather than replacing the model-based estimator, the predicted reliability weights are used to blend FK velocity observations with IMU-propagated body velocity and to adapt the observation covariance of an extended Kalman filter (EKF), enabling smooth reliability-aware fusion without hard contact switching. The network is trained from automatically generated simulation signals using an FK-weighted velocity consistency loss with lightweight simulator-contact regularization, without manually annotated continuous FK-reliability labels. The deployed model relies only on IMU and joint kinematic measurements, making it suitable for hardware platforms with unreliable torque sensing. Experiments demonstrate that FOCUS reduces absolute trajectory error (ATE) by 83.7% on simulated walking episodes, preserves simulated dynamic-motion fidelity in motion scale and spectral energy, reduces ATE by 70.8% across 19 real walking segments, and reduces mean ATE by 42.7% across four real dynamic-motion routines.

0.32

HeadIO: Body-Frame Heading Decomposition for Neural Inertial Odometry on Head-Mounted Devices

cs.CV cs.RO ·2026-11-11 ·Taeyoung Yeon, Yiquan Li, Chenfeng Gao, Vasco Xu, Karan Ahuja
benchmark similarity 0.64
Abstract · Submitted to ICRA 2027

Inertial odometry (IO) using only Inertial Measurement Units (IMUs) enables camera-free head tracking in head-mounted devices such as VR headsets, AR glasses, and earbuds. Prior IO methods operate in a gravity-aligned world frame, which is not yaw-equivariant. Yaw augmentation improves robustness but does not guarantee equivariance; learned equivariant layers achieve it, but EqNIO's full pipeline costs nearly 3$\times$ the FLOPs of ours. While raw body-frame IMU inputs are inherently yaw-invariant, head tilt redistributes both gravity and motion signals across device axes, making the representation tilt-variant. We propose HeadIO, which combines a body-frame heading decomposition with a bidirectional Mamba backbone for head-mounted inertial odometry. Our decomposition achieves tilt invariance by separating gravity-aligned and horizontal components using only the tilt component of device orientation. We evaluate on four head-mounted datasets and find that HeadIO improves RTE-5s by 8.1% (0.260 m $\to$ 0.239 m) over world-frame methods with learned equivariant layers on Nymeria, the largest benchmark dataset, at nearly 3$\times$ lower FLOPs and 8$\times$ fewer parameters. HeadIO achieves state-of-the-art performance on our primary metric, RTE-5s, on all Aria-glasses datasets, which natively provide body-frame semantics for our decomposition method. We further evaluate the IMU-only deployment scenario on Nymeria, where HeadIO remains state-of-the-art. We show that our method relies mainly on tilt accuracy, which can be obtained from the gravity signal; for yaw, a single-coefficient gyroscope correction removes 11.6% of the yaw error and improves RTE-5s by 2.5%, and sparse external yaw corrections (for example, one every 30 s) can improve RTE-5s by 12.0%. Our decomposition is lightweight, composes with any backbone, and is suitable for real-time deployment on head-mounted devices.

0.18

GaitVista: Reliability-Aware AI Measurement toward Accessible Longitudinal Gait Assessment

cs.AI ·2026-09-18 ·Nethmi Jayasinghe, Mihir Parashar, Amit Ranjan Trivedi
similarity 0.62
Abstract

Tracking recovery of walking function requires detecting meaningful gait change across rehabilitation sessions, yet objective 3D measurement remains confined to specialized motion-capture laboratories. Small camera sets and body-worn inertial sensors broaden access, but reliability varies across joints and time, allowing sensing failures to masquerade as patient change. We present \textsc{GaitVista}, a reliability-aware measurement layer whose lightweight gate assigns joint- and frame-specific visual contributions using camera coverage, local visual quality, cross-modal disagreement, and root-motion continuity, and exposes them for inspection. Across seven clean and degraded sensing conditions on TotalCapture, \textsc{GaitVista} reduces average full-body and lower-body error by \textbf{27.7\%} and \textbf{27.8\%}, attains the lowest worst-condition error among fusion methods, and reduces the gap to a joint-frame oracle from $2.76$--$5.33$~cm for condition-blind baselines to $1.11$~cm. On MoVi with image-derived keypoints, it is the only deployable fusion method to improve over both unimodal streams, reducing marker-supported error by \textbf{6.4\%} relative to the strongest learned fusion baseline. On TotalCapture, it improves bilateral knee-flexion waveform accuracy by \textbf{18.9\%}. Raw inertial measurements from five TotalCapture participants show location- and time-varying magnetic disturbance, supporting the design's reliability premise. Both benchmarks contain neurologically healthy participants in controlled settings and retain participant-specific IMU calibration; we therefore report progress toward accessible gait assessment, not validated clinical deployment.

0.23

SG-ODOM: Event-Driven Proprioceptive State Estimation with Stability-Gated Contact Updates for Legged Robots

cs.RO ·2026-11-16 ·Francesco Iotti, Chiyun Noh, Franco Angelini, Manolo Garabini, Ayoung Kim +2 more
code/data similarity 0.62
Abstract

Reliable proprioceptive state estimation for legged robots fuses inertial sensing with kinematic sensing from leg encoders. The latter assumes a foot is stationary during the stance phase; however, physical foot touchdown does not necessarily provide a stationary reference for odometry, particularly during impact and load transfer. Repeatedly applying kinematic corrections throughout the same contact phase can introduce redundant or unreliable information. We present SG-ODOM, a proprioceptive odometry framework that uses stability-gated contact selection to schedule kinematic updates. Following physical touchdown, a stability gate accepts the contact for state estimation only after the foot reaches a sufficiently stable support condition. The resulting validated touchdown event triggers an estimator correction, while additional timeout updates bound the maximum duration of uninterrupted IMU propagation. The framework is evaluated on multiple legged platforms, both quadrupedal and humanoid robots, against representative state-of-the-art proprioceptive estimators. Across the evaluated sequences, SG-ODOM demonstrates competitive or superior estimation accuracy, reducing Relative Pose Error (RPE) by up to 25% compared to the baseline estimator on outdoor sequences from the GrandTour dataset. Source code: https://github.com/ori-drs/SG-ODOM. Video: https://youtu.be/-583_RyuhqQ

0.39

IMU-Aided Correction of Orientation-Induced Ranging Error in Bluetooth Channel Sounding on Commercial Hardware

eess.SY ·2026-09-01 ·Mihir Bapat, Santosh Nagaraj
similarity 0.61
Abstract

Bluetooth Low Energy Channel Sounding (BLE CS), standardized in Bluetooth Core Specification 6.0 (September 2024), enables distance estimation via phase-based ranging (PBR) and round-trip time (RTT). Although prior work has studied CS accuracy in configurations with a fixed orientation, no published work has studied how device orientation affects ranging error on commercial hardware. We present the first study of orientation-induced CS ranging error and a Machine Learning correction using IMU features. This study used the EFR32xG24 Channel Sounding Development Kit, the only commercial CS platform with an integrated six-axis Inertial Measurement Unit (IMU). Our results show that device orientation has a substantial effect on CS ranging accuracy; we found that a Random Forest model trained on the IMU derived orientation achieved a 74.6\% Mean Absolute Error (MAE) reduction under a Leave One Orientation Out Evaluation, demonstrating that IMU readings have potential to improve ranging accuracy.

0.18

Wear and Go: Calibration Free Sparse Inertial Motion Capture via Online Sensor Setup Estimation

cs.CV ·2026-11-17 ·Yuanshuo Tan, Licheng Zhong
similarity 0.61
Abstract

Sparse inertial motion capture typically assumes that each sensor's anatomical identity and mounting orientation are known. We present MOSAIC (Motion-based Sensor Assignment and Inertial Calibration), a framework that recovers this setup from ordinary motion without a calibration pose. Our central insight is that body pose changes continuously while the sensor setup persists, allowing movements that are individually ambiguous to provide complementary evidence over time. A setup network processes unordered sensor streams with temporal and cross-sensor attention, then accumulates assignment and rotation evidence into a session-level estimate. The recovered setup canonicalizes measurements for frozen pretrained pose estimators, separating sensor configuration from motion reconstruction. For sensors worn at prescribed body sites, evaluation on real inertial recordings with randomized setups shows near-calibrated pose accuracy for bounded offsets and substantial benefits from accumulation under arbitrary orientations. Transfer across pose networks supports setup recovery as a reusable interface between interchangeable sensors and pretrained pose models.

0.18