Frequency-Dependent Breakdown of Litz-Wire Insulation Under Repetitive Bipolar Square-Wave Voltages

Md Asifur Rahman, Farzana Islam, Mona Ghassemi

eess.SY cond-mat.mtrl-sci ·submitted 2026-10-04 14:03 UTC · v1
unusual

Abstract

This paper investigates the dielectric breakdown behavior of Litz wire insulation subjected to repetitive fast-edge bipolar square-wave voltages representative of wide-bandgap (WBG) power converter stress. Two conductor sizes, 14 AWG and 16 AWG, were tested in a twisted-pair configuration over frequencies ranging from 1 kHz to 30 kHz using a controlled high-voltage pulse generator with 200 ns rise time. The breakdown voltages obtained at each frequency were statistically analyzed using the weighted two-parameter Weibull method in accordance with IEEE Std 930-2004. Between 1 and 30 kHz, the mean breakdown voltage decreases by approximately 10.7% for the 14 AWG construction and 20.0% for the 16 AWG construction. The 14 AWG specimens exhibit a modest increase between 1 and 5 kHz followed by a decline, whereas the 16 AWG mean decreases across the tested frequencies. The Weibull shape parameter varies nonmonotonically with frequency, characterizing differences in the dispersion of the measured breakdown voltages. These findings provide construction-specific breakdown data relevant to Litz-wire insulation assessment in high-frequency power electronic applications. Possible contributions from charge accumulation, localized discharge activity, and dielectric heating are discussed, but were not directly verified in this study.

Closest papers

Nearest neighbours by meaning across the whole index.

KPG193-ext: A Synthetic Korean Power Grid Test System for Stability Analysis

eess.SY ·2026-11-09 ·Sungyoon Song, Geonho Song, Min-han Yoon, Yong-Hyun Song, Seung Wan Kim +1 more
similarity 0.38
Abstract

Growing shares of inverter-based generation and constrained transmission expansion increase the need to assess stability across operating conditions. Production-cost models provide chronological commitment and dispatch, but stability analysis requires corresponding electrical detail and device dynamics. This paper introduces KPG193-ext, an extension of the synthetic Korean power-grid test system KPG193 that links chronological operating points with detailed electrical and dynamic models. The extension adds synchronous-machine, controller and renewable-converter models, together with explicit voltage levels, generation terminals, inter-voltage and step-up transformers, and reactive compensation. The resulting 731-bus network retains the original 193 regional locations. Daily unit commitment followed by hourly AC optimal power flow establishes 8,760 operating points for 2025, each distributed as paired steady-state and dynamic-model files. Selected-hour studies examine generation-loss frequency response, steady-state flow-voltage characteristics, and rotor-angle response with special protection system actions. The results reveal differences in delivered frequency support, internal voltage stress along regional transfer paths, and the angle-frequency tradeoff of corrective generator tripping. The database provides a common basis for examining the stability implications of commitment, dispatch and corrective action across daily and seasonal operating conditions.

0.32

DER-Fault: A Simulation-Based Fault Dataset for DER-Integrated Distribution Systems Under Diverse Operating Conditions

eess.SP ·2026-09-28 ·Fathima Razeeya Mohamed Razick, Petr Musilek
similarity 0.36
Abstract · 10 pages, 4 figures, Associated dataset available on Zenodo

The growth of distributed energy resource (DER) integration introduces greater variability in distribution system operating conditions, creating a need for comprehensive datasets for developing and evaluating data-driven fault diagnostic methods. This paper presents \textbf{DER-Fault}, a simulation-based dataset generated in OpenDSS using the Iowa 240-bus distribution system with photovoltaic (PV) generation, electric vehicle (EV) charging, and vehicle-to-grid (V2G) operation. To capture annual load variability while maintaining a manageable number of simulation cases, 60 representative operating conditions are selected from 8,760 hourly load profiles, covering peak, off-peak, transition, typical weekday, and typical weekend conditions. Six DER scenarios with varying PV and EV penetration levels and V2G participation are considered. The dataset includes normal operation and ten short-circuit fault classes, with varying fault resistance. Pre- and post-fault voltage and line-current phasor measurements are recorded at selected measurement locations, resulting in 19,800 simulation cases. Technical validation demonstrates broad coverage of annual loading and DER operating conditions, distinct phase-specific responses corresponding to the simulated fault types, and a consistent reduction in voltage-phasor disturbance with increasing fault resistance. The resulting dataset provides a structured resource for developing and evaluating machine-learning and other data-driven methods for fault detection, classification, and localization in DER-integrated distribution systems.

0.26

Generalized and Unified Power Flow Framework for Converter-Dominated AC/DC Power Grids

eess.SY ·2026-10-18 ·Hamin Chang, Fei Teng, Gyu-Sub Lee, Jae-Won Chang
code/data similarity 0.36
Abstract · Submitted to IEEE Transactions on Power Systems. 10 pages + 10-page appendix (Appendices A-C included at the end). Code: https://github.com/…

Modern power grids increasingly rely on power electronic interfaces, requiring steady-state power flow analysis to accommodate diverse operating modes and network structures. Conventional approaches often rely on system-specific formulations and sequential approaches to handle such complexity. However, these approaches may limit applicability to diverse grid configurations and lead to convergence and computational issues. To address these limitations, this paper proposes a generalized and unified Newton-Raphson (NR) power flow framework for AC/DC hybrid grids. For generalized operational modeling, conventional and droop operating modes of generators and interlinking converters are represented through a common set of coefficients. For generalized structural modeling, models of AC transformers and DC/DC converters accommodate different transformer winding configurations and converter operating modes. For a unified solution, augmented variables are introduced to incorporate droop deadbands, output limits, and converter station losses into a single NR formulation, eliminating the need for sequential outer loops. To validate the effectiveness of the proposed framework, its results are compared with those obtained from existing power flow methods and electromagnetic transient simulations across transmission networks, distribution networks, and microgrids. The implementation is made publicly available to facilitate its use in analyzing AC/DC hybrid grids.

0.36

Experimental Characterization of SMD Inductors for Cryogenic Power Conversion at 4 K

eess.SY ·2026-10-20 ·Rami Rasheedi, Umeshkumar Patel, Jonathan Baldwin, Antonino Miceli, Inna Partin-Vaisband
unusual similarity 0.36
Abstract

With the increasing complexity and scalability demands of cryogenic electronic systems, such as quantum computing platforms, conversion of power within the cryogenic environment has become a primary concern. Magnetic inductors are among the key components affecting converter performance, as their electrical and magnetic properties can change significantly at low temperatures. In this paper, five commercially available Vishay SMD power inductors are experimentally characterized down to 4 K: DC resistance is measured continuously during cooldown, while frequency-dependent AC inductance and resistance are measured up to 2 MHz at both room temperature and 4 K. The results show substantial DC resistance reductions of 25x-58x at 4 K, while the inductance degrades by only about 5-5.5%. Although cryogenic operation slightly increases the AC resistance (due to the intensified skin effect) and raises core losses, converter-level analysis shows an inductor-only efficiency improvement of approximately 5.3-6.9 percentage points at 1 A, and up to 22.8 points at 3 A. The measured frequency-dependent impedance of each inductor is imported into Cadence and a complete single-phase 24 V-to-1 V buck converter with GaN power devices is simulated at 1, 2, and 3 A at 4 K. The full-converter efficiency at 4 K is shown to improve by 3.0-5.2 percentage points at 1 A and by up to 22.5 points at 3 A for the AC-characterized devices. These findings indicate that commercially available off-the-shelf power inductors remain operationally viable under cryogenic conditions and can simultaneously increase inductor efficiency and reduce the overall power loss in cryogenic power conversion systems.

0.24

Current-Limiting Control for Fault Ride-Through of LLC-based Solid-State Transformer in Data Centers

eess.SY ·2026-08-27 ·Haoyu Wang, Chi Zhang, Mafu Zhang, Rudy Wang, Peter Barbosa
similarity 0.36
Abstract · Added IEEE submission notice

Solid-State Transformers (SSTs) are increasingly proposed as the interface between distribution grids and data centers due to flexible power flows and fast dynamic response. However, when a short-circuit fault occurs in a load branch, the SST with a voltage-source-type DC-DC stage is forced to shut down due to fault currents. Therefore, current-limiting strategies are strongly needed to prevent catastrophic equipment damage and cascading blackouts by instantly restricting massive current spikes and offering sufficient currents for protection devices to act at the faulted branch. This paper proposes a coordinated DC load fault-tolerant current-limiting and recovery strategy embedded directly in the control of the SST DC-DC stage, avoiding additional hardware cost. Specifically, the fault mechanism of an example LLC resonant converter is studied. Accordingly, a fault detection framework is implemented, a closed-loop current controller is proposed to limit the DC current to a designated value within microseconds by surging the switching frequency and adjusting the duty cycle, and a ramped recovery stage will then restore the DC bus after the fault isolation without inrush currents. Experiments on an LLC converter prototype have verified the feasibility of the proposed current-limiting strategy, enabling faster and lower-cost fault response suitable for resilient data center power architectures.

0.26

Stray Losses in Power Transformers: A Comparative Study of Modeling Frameworks for Mild Steel

eess.SY ·2026-11-03 ·Micha Swaanen, Timo Overboom, Siamak Pourkeivannour, Tom Huiskamp, Guus Pemen
benchmarkunusual similarity 0.36
Abstract · 13 pages, 18 figures. Submitted to IEEE Transactions on Magnetics

Accurately predicting eddy-current and hysteresis losses in mild steel components such as the structural parts and tank of power transformers remains a challenge in transformer design. Conventional numerical approaches for eddy-current loss analysis require discretization at a fraction of the skin depth. While accurate, such fine volumetric mesh becomes computationally prohibitive for large power transformers. Moreover, hysteresis loss is not always included in this analysis. To investigate the trade-off between computational cost and accuracy, this work presents a comparative analysis of eight distinct modeling frameworks for predicting both eddy-current and hysteresis losses in mild steel. These include efficient methods avoiding meshing, such as standard impedance boundary conditions, and more accurate approaches retaining full volumetric meshing, namely complex permeability, nonlinear single-valued B-H curve, and Jiles-Atherton hysteresis modeling. To accurately represent the material's electromagnetic behavior, the properties of the mild steel used are measured directly from samples. Finally, loss measurements are conducted to benchmark all eight frameworks, demonstrating mean absolute percentage errors between predictions and measurements generally below 20%.

0.33

Beyond Tomorrow -- Electrification of Hard-to-Abate Sectors

eess.SY ·2026-09-28 ·Jonas Huber, Johann W. Kolar
similarity 0.35
Abstract · Submitted to IEEE magazine

Reaching net-zero greenhouse-gas (GHG) emissions requires deep electrification beyond ground transportation, buildings, and conventional industry automation. This article discusses direct electrification pathways for hard-to-abate sectors, which today account for 30% of global GHG emissions and include steel, cement, chemicals, aviation, and shipping. Whereas indirect electrification via hydrogen and synthetic fuels will remain indispensable for some applications, direct use of electricity is generally preferable from an efficiency perspective. We review selected emerging opportunities for power electronics in industrial process electrification, including steelmaking through hydrogen plasma smelting reduction or molten-oxide electrolysis, electrified cement production, high-temperature process heat, plasma-assisted chemistry, and electrochemical synthesis. Across these examples, power converters must interface with highly application-specific loads, ranging from low-voltage high-current electrolysis cells to dynamic plasma reactors and megawatt-scale induction heating systems. In addition, high-power grid interfaces and in-plant energy management/buffering solutions must be clarified. Thus, future electrified industrial processes open new "beyond-tomorrow" research challenges for power electronics in close interdisciplinary collaboration with scientists from neighboring disciplines.

0.26

Limitations of RMS-based Stability Assessment of Converter-based Grids: A Case Study

eess.SY ·2026-08-19 ·Pol Jane-Soneira, Ognjen Stanojev, Francisco Canales Perez, Qian Long, Mario Schweizer +1 more
similarity 0.35
Abstract

The increasing penetration of power electronic converters in industrial grids introduces stability challenges at frequencies well above the electromechanical range of traditional power systems. Commercial software tools typically perform eigenvalue-based stability analysis using root-mean-square (RMS) models that assume a quasi-stationary network, thereby neglecting electromagnetic dynamics of assets --- which is standard practice in power system analysis. This paper presents a case study of an industrial grid where the conventional RMS-based eigenvalue analysis predicts stable operation, while a detailed electromagnetic transient (EMT) simulation reveals growing oscillations, indicating instability. To bridge this gap, we introduce an alternative modeling approach that formulates the network dynamics in the rotating $dq$ reference frame, retaining the differential equations of electromagnetic dynamics. The resulting model enables eigenvalue analysis that correctly identifies the unstable modes, consistent with the EMT simulation results. Our findings highlight a fundamental limitation of RMS-based stability assessment for converter-dominated grids and demonstrate that dynamic impedance models in the dq frame provide a viable path toward accurate small-signal analysis encompassing high-frequency converter-network interactions.

0.32