A Belief-State World Model for Catheter Navigation under Sparse Fluoroscopy: A Planar Proof of Concept

Damini Rijhwani

cs.RO ·submitted 2026-10-06 14:52 UTC · v1
published

Abstract

Endovascular catheter navigation relies on continuous fluoroscopy, exposing patients and clinical staff to ionizing radiation throughout the procedure. We investigate whether a physics-based world model can sustain the navigation task between deliberately sparse X-ray acquisitions, and whether the model can signal when its internal state estimate is no longer reliable. We formulate sparse-fluoroscopy navigation as a partially observable Markov decision process where a Cosserat rod simulator supplies transition dynamics, sparse noisy projections provide observations, and a particle filter maintains a belief over the device state, reduced in this implementation to a tip state with a geometric contact proxy. We evaluate this formulation in a deliberately simplified setting: a synthetic planar vessel phantom with a quasi-static rod model and simulated projections, without clinical or animal data. In this setting, the belief-state model tracks the simulated tip with a root mean square error of 1.30 mm while acquiring observations at one fifteenth of the continuous rate (0.97 mm at every frame, 1.51 mm at one thirtieth), reported 90 percent credible intervals achieve 0.92 empirical coverage, and the belief-derived contact risk estimate discriminates unsafe contact events with an AUROC of 0.68. These results constitute a proof of concept on a simplified simulation rather than a demonstration of clinical readiness; their purpose is to establish that calibrated belief, rather than point-estimate accuracy alone, is the essential property a sparse-imaging world model must deliver.

Comment
Presented at the IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS 2026) Workshop on Surgical Digital Twins (SurgTwin). 4 pages, 2 figures

Closest papers

Nearest neighbours by meaning across the whole index.

Anatomy-Change-Aware Bidirectional Selective State-Space Memory for Clinically Deployed Thoracic Radiotherapy Auto-Contouring

eess.IV cs.CV ·2026-09-11 ·Galib Ahmed, Istiak Ahmed, Aritra Islam Saswato, Asib Mostakim Fony, Kazi Shahriar Sanjid +13 more
similarity 0.59
Abstract

We developed DAMM-Net++, a 2.5D architecture for thoracic OAR and target volume segmentation that addresses three persistent challenges in radiotherapy auto-contouring: inter-slice surface incoherence, systematic failure on small low-contrast targets, and the absence of per-case reliability signals. The central component is an anatomy-change-aware bidirectional selective state-space memory that models through-plane anatomical change and selectively propagates context along the axial slice sequence. A boundary-aware decoder sharpens near-surface predictions, and an uncertainty head provides calibrated per-voxel confidence for clinical triage. We evaluated 2,146 patients across four centers, an independent external cohort of 112 patients, and a multicenter reader study involving 17 radiation oncologists on 305 cases. The model achieves a mean Dice of 0.955 and HD95 of 3.78 mm, with the largest gains on low-contrast organs-at-risk (OARs) and target volumes where through-plane context is most critical. The uncertainty head is well-calibrated and supports case-level triage. In the reader study, AI assistance reduced contouring time by 75-80% across experience levels and raised junior-reader IoU from 0.861 to 0.925, matching the unedited model. External validation showed a modest internal-to-external drop (< 5%) with calibrated uncertainty transferring without recalibration. The complete deployment pipeline from DICOM ingestion to TPS-compatible RTSTRUCT export has been integrated into the clinical workflow at a partner hospital, where it is used to assist with contouring. These results suggest that anatomically motivated inter-slice memory, paired with uncertainty-guided review, offers a clinically viable path for thoracic auto-contouring.

0.20

ActiveReg: Information-Driven Active Regional Probing for Partial-to-Full Bone Registration

cs.RO ·2026-10-07 ·Tiancheng Li, Yingyu Wang, Peter Walker, Liang Zhao, Shoudong Huang
similarity 0.56
Abstract · Preprint

Accurate bone registration is essential for orthopedic surgical navigation and robotic assistance. In a common workflow, the surgeon needs to identify and probe a number of prescribed locations on the exposed bone surface to obtain data points for registration, which can be difficult and time-consuming under limited surgical exposure. Reducing the number of required points while providing clear probing guidance would ease the surgeon's acquisition task intra-operatively. We present ActiveReg, a closed-loop framework that recommends probing regions rather than individual points, allowing flexibility in the exact contact location. A D-optimal planner that takes into account the already acquired points and the uncertainty of current registration information helps achieve accurate registration with fewer points. An online assessment combines pre-update innovation consistency with uncertainty at predefined surgical task locations improves the reliability of completion decision, without requiring ground truth. Simulations across four anatomical scenarios demonstrated that ActiveReg can achieve competitive accuracy compared with baseline registration methods while using substantially fewer acquired points. Real phantom experiments with optical and electromagnetic tracking demonstrated comparable mean target registration error to the Gradient-SDF framework, using only 24-28 acquired points instead of 771-1263.

0.25

A 2D Image Feedback-Based Autonomous Endovascular Navigation Method: A Perception and Control Framework

cs.RO ·2026-10-15 ·Sheng Cao, Shuxiang Guo, Yonggan Yan, Jian Guo, Chunying Li +6 more
similarity 0.55
Abstract

In endovascular interventions, physicians rely on planar DSA and X-ray fluoroscopy to interpret vessel anatomy and device motion, yet converting these images into feedback for autonomous navigation remains difficult. A perception and control method is formulated for two-dimensional image feedback. Vessel masks are converted into a labeled centerline graph, and device-tip estimates are projected onto a planned path to obtain progress, deviation, and direction. A rule-based controller uses these quantities for delivery, branch selection, probing, rollback, and recovery. The method was evaluated on a physical dual-device robotic platform in 65 closed-loop runs using simulator-rendered planar images across three paths. All runs reached at least 0.95 maximum observed guidewire progress; two runs (3.1%) met the prespecified failure rule of three or more autonomous stop events. The results establish route-level performance on the tested platform; clinical image sequences and broader anatomy remain to be evaluated.

0.19

A digital-twin framework for forecasting treatment-day imaging with contour uncertainty in adaptive proton radiotherapy

cs.AI physics.med-ph ·2026-09-21 ·Yizhou Wu, Jie Ding, Justin Roper, Minglei Kang, Yuheng Li +4 more
similarity 0.54
Abstract

Head-and-neck anatomy changes over a six-to-seven-week proton course, and the anatomy of a later week cannot be imaged when the plan is made. We present a digital-twin framework that forecasts a patient's treatment-day anatomy as an ensemble of predicted CTs with propagated contours and quantifies the uncertainty of the forecast contours. The twin is a library of previously treated patients with planning and weekly quality-assurance CTs (QACTs), made patient-specific by a two-step foundation-model deformable registration: a cross-patient field carries each library patient onto the current patient, and a longitudinal field, estimated in the current patient's frame, carries that patient's planning-to-QACT change onto the current patient's own planning CT. A library of 302 observations from 88 patients yields about 300 replicates per patient, each a deformation that occurred in a treated patient. The dispersion of the propagated contours, resolved by outward normal, is six-direction contour uncertainty in millimeters. This is uncertainty in the input to the forecast, which library patient the current patient follows, rather than in model parameters, and it is unchanged when the registration engine is exchanged. On ten patients with clinician contours on two QACTs, the library alone fixes the anisotropic shape of the uncertainty (4.5 to 6.2 mm); the first QACT narrows it by a factor of 3.2 to 3.6 without a contour being drawn; an approved contour improves the center but not the width. The estimate orders directions correctly but is not Gaussian-calibrated. A clinical target volume expansion is worked out as one application.

0.43

When can multi-fragment 2D/3D registration be trusted? Calibrated certification and uncertainty-driven view planning for pelvic fracture fluoroscopy

eess.IV cs.CV ·2026-11-03 ·Bowen Xiang, Michael I. Miga
similarity 0.53
Abstract

Registering a segmented CT to fluoroscopy can locate every fracture fragment but can guide surgery only when trusted. After each shot, our closed loop registers all fragments, bounds their errors with a calibrated sandwich covariance, flags implausible or ambiguous ones, and stops or plans the next view. On simulated fluoroscopy of 60 held-out fracture CTs with realistic image uncertainty, 95% bounds covered 83% of unflagged fragments and 91% of those within 5mm, but from the second view on 14% failed by over 5mm, a third with bounds of at most 2mm. A fragment's shift when a view was added separated tightly bounded failures best (exploratory; AUC 0.94, bound 0.81). Requiring that the newest view moved no fragment beyond its bound, preferred post hoc, lowered false stops at 2mm from 23% to 6% overall, with 345 instead of 362 correct ones but more trajectories uncertified; delaying the stop did not, and other signals at equal acceptance left 10-15% false. With a segmentation error shared by all views (median Dice 0.89), 21% of this rule's stops were false against 10% without it (15 cases; exploratory). Minimax planning certified sooner than the clinical protocol without the check (4.20 versus 4.72 shots, Holm p <0.001), but no criterion reached the pre-specified endpoint, a true 2mm error, significantly sooner, even in the true basin. On real fluoroscopy of five intact pelves no 2mm certificate was false. Trust takes evidence across views, not only a calibrated local bound.

0.25

Contrast-Free Autonomous Navigation of Untethered Endovascular Microrobots Using Single-Plane Fluoroscopy

cs.RO ·2026-08-31 ·Husnu Halid Alabay, Tuan-Anh Le, Ping Wang, Hakan Ceylan
similarity 0.53
Abstract · 34 pages, 9374 words

Reliable three-dimensional (3D) navigation of magnetically actuated untethered microrobots remains a major barrier to clinical translation. X-ray fluoroscopy is the standard real-time imaging modality for endovascular procedures, but single-plane fluoroscopy provides only a two-dimensional (2D) projection, eliminating depth information and complicating autonomous navigation. Recovering this information through biplane imaging or repeated contrast-enhanced angiography increases procedural complexity, radiation exposure, or contrast burden. Here, we introduce VISTA (Virtual Integration for Spatial Tracking and Autonomy), a digital twin framework enabling contrast-free autonomous navigation under single-plane fluoroscopy. VISTA reconstructs vascular anatomy as a 3D digital twin, discretizes the vessel centerline into navigation milestones, and assigns the detected 2D robot position to the nearest projected milestone. Consecutive milestones define the local vessel orientation used to generate magnetic actuation commands, converting single-plane fluoroscopic observations into topology-constrained navigation states without requiring contrast injection during navigation. VISTA is demonstrated across anatomically distinct vascular phantoms under continuous flow and within the inferior vena cava of a live rat in vivo. Compared with conventional fluoroscopic human-in-the-loop control, VISTA reduced navigation time by up to 62%, corrective actuation commands by up to 98%, and radiation exposure by up to 57%. These results establish VISTA as a digital twin-guided framework for contrast-free autonomous navigation of untethered endovascular microrobots using widely available single-plane fluoroscopy.

0.31

Novel Methods for Catheter and Guidewire Segmentation in X-ray Fluoroscopy under a Federated Learning Setting

cs.CV cs.AI ·2026-09-06 ·Chayun Kongtongvattana
benchmark similarity 0.53
Abstract · PhD Thesis, University of Liverpool. 163 pages

Endovascular procedures rely on real-time manipulation of thin instruments, catheters and guidewires, under X-ray fluoroscopy guidance, where accurate visual analysis is essential for procedural safety. Learning-based methods are constrained by structural complexity, data scarcity, and privacy regulations precluding centralised training across institutions. This thesis presents a structure-aware federated learning framework for catheter and guidewire analysis, with four contributions evaluated on real-animal and phantom data. A benchmark dataset, CathAction, is introduced for catheterisation analysis, with over 600,000 annotated frames and 40,000 segmentation masks. A shape-sensitive loss transforms masks into signed distance maps compared in a structural feature space, improving Dice coefficient by up to 2.9 points across five backbones. This is extended to federated learning with shape-sensitive loss, preserving geometric consistency under heterogeneous client data and outperforming federated averaging by up to three points in mean intersection-over-union as clients scale from four to eight. Federated learning with projected gradient descent adds adversarial optimisation, raising mean intersection-over-union by over ten points on real-animal data. Finally, a structure-aware diffusion framework synthesises catheter and guidewire video sequences, combining structural supervision with a domain-adaptive reconstruction objective, reducing Frechet video distance over a strong baseline while maintaining visual fidelity. Incorporating synthetic sequences into federated training raises the Dice score from 44 to 51 percent under data scarcity, with gains across four held-out sites. Together, these contributions advance privacy-preserving catheter and guidewire analysis, supporting collaborative training without centralising patient data or large amounts of manual annotation.

0.38

EUReCA: End-to-End Unified CBCT Reconstruction Across Clinical Acquisitions

eess.IV cs.AI ·2026-10-27 ·Jiening Zhu, Chengzhu Zhang, Jason Fan, LiCheng Kuo, Weixing Cai +6 more
similarity 0.53
Abstract

Cone-beam computed tomography (CBCT) is widely used for image-guided radiotherapy, but reducing the number of projections to lower dose and scan time makes reconstruction increasingly ill-posed. We present EUReCA (End-to-end Unified REconstruction across Clinical Acquisitions), a geometry-aware feed-forward model for variable-view clinical linac CBCT. For a given acquisition trajectory, EUReCA accepts 8-100 projections with a single set of weights, without view-count-specific retraining; the same architecture and training recipe extend unchanged to other clinical trajectories. It combines learned projection features with an in-frame Feldkamp-Davis-Kress (FDK) reconstruction. The model encodes each projection with a shared multiscale backbone, back-projects features into multiresolution 3D grids using the acquisition geometry, aggregates variable numbers of views at fixed computational cost, and refines the volume with a global 3D transformer and multilevel decoder. On simulated data, EUReCA achieved 29.9-33.2 dB PSNR with 10-100 views and outperformed all applicable feed-forward baselines; it also exceeded iterative optimization-based methods while running orders of magnitude faster. On 15 measured patient CBCT scans evaluated against vendor reconstructions, EUReCA achieved the best performance at every tested view count. These results suggest that geometry-aware, measurement-anchored feed-forward reconstruction can provide a practical and flexible foundation for variable-view linac CBCT.

0.25