CS Paper Radar

Relining or Replacement: How Timing, Costs, and Infrastructure Shape U.S. Primary Steel Decarbonization

Mohamed Atouife, Yuezhang He, Jesse D. Jenkins

eess.SY ·submitted 2026-10-10 12:33 UTC · v1

Abstract

Imminent blast furnace relinings create a consequential investment window for U.S. primary steel decarbonization. Using plant-level capacity planning and stochastic operations modeling, we quantify the costs, infrastructure, and fiscal requirements to transition legacy blast furnace sites to direct reduction under supply-side incentives. Under baseline assumptions, post-subsidy premiums above average blast furnace costs, including relining, are 272 to 427 dollars per ton of steel for near-zero-emission hydrogen-based direct reduction and 115 to 181 dollars for natural-gas-based production. Representative facilities producing two million tons of steel annually at legacy locations require approximately 4 to 6.5 and 0.7 to 1.1 GW of renewable generation and battery storage, respectively. This translates to 65 and 12 GW across the unrelined fleet for hydrogen- and natural gas-based pathways, respectively. These findings connect replacement timing to costs, infrastructure, and public support, motivating a sequenced transition through clean-powered natural-gas-based direct reduction to avert blast furnace relining, reduce emissions by 57 percent relative to blast furnaces, and preserve options for deeper decarbonization through hydrogen substitution or carbon capture.

Closest papers

Nearest neighbours by meaning across the whole index.

Massachusetts' 2026 Clean Peak Standard Recalibration: Adaptation and Storage Tradeoffs

eess.SY ·2026-09-29 ·Yuhan Dai, Boyu Yao
published similarity 0.55
Abstract · Accepted for IEEE GESS 2026

Massachusetts recalibrated its Clean Peak Standard (CPS) in 2026 by lowering the minimum standards and expanding the Near-Term Resource Multiplier for qualifying storage. This paper evaluates the change using a three-zone, hourly capacity expansion model for 2026--2030. Both scenarios achieve full CPS compliance, but the post-May scenario reduces new battery additions by 53.1% and modeled system cost by 3.7%. CPS-eligible discharge declines by 30.4%, while Clean Peak Energy Certificate production declines by only 9.5%. Fossil generation during CPS hours increases by 11.7%, whereas modeled emissions remain nearly unchanged because the Regional Greenhouse Gas Initiative cap binds. The recalibration therefore lowers the modeled storage capacity requirement while weakening physical clean-peak performance.

0.36

Shift or curtail? How much data-center flexibility is worth depends on the host power grid

eess.SY physics.soc-ph ·2026-08-20 ·Saroj Khanal, Geon Roh, Boyu Yao, Abraham Silverman, Dennice Gayme +3 more
similarity 0.53
Abstract · Submitted to Nature Energy

Data-center growth risks overbuilding power grid infrastructure and stranding capital. Flexible data-center operation can defer infrastructure investments, but its value depends on the flexibility mechanism and the host power grid characteristics. We classify data-center load as firm, flexible or interruptible, and embed them in capacity expansion applied to market-organized, fossil-heavy PJM and carbon-capped, centrally coordinated Korea. In PJM, the flexibility value is spatial: shifting workloads between zones reduces system cost by 6% in 2028 and 19% in 2038, avoiding 4.4 GW and 8.9 GW of gas and nuclear generation. In Korea, it is temporal: shifting load into midday solar hours makes 0.5 GW of additional solar worth building in 2028 and avoids 1.2 GW of gas and 0.3 GW of batteries in 2038. In both, realistic event-shape limits diminish the value of curtailment. The results show that flexibility procurement and its value are driven by grid characteristics and policy objectives.

0.45

The consequences of high SMR operating costs in electricity markets

eess.SY econ.GN ·2026-09-08 ·Pradyumna Rao, Daniel T. Kaffine, Bri-Mathias Hodge
similarity 0.50
Abstract

As US power markets contend with growing demand for firm generation, the nuclear industry has offered Small Modular Reactors (SMRs). However, how these concepts would fare in a rapidly evolving power grid is unclear, given the paucity of operational examples. Current literature, informed by substantial cost escalations for traditional nuclear plants, focuses on the investment costs SMRs need to achieve for private investment feasibility. However, this work finds that the operating and marginal costs of SMRs are more critical to economic feasibility in market environments. This work dispatches SMRs using a flexible operations model, considering revenue from two main electric markets, capacity and wholesale energy markets, with and without policy support. Manufacturer advertised costs for investment and operating costs are used, with fuel costs calculated from manufacturer provided design parameters. Results indicate that SMRs are uneconomical primarily because investment cost reductions are offset by increased marginal costs. As such, an environment of prices and subsidies beyond historic norms are necessary to attract private investment at manufacturer advertised cost benchmarks. Current SMRs are as profitable as advanced estimates of the AP1000 traditional nuclear reactor, and if investment costs escalate at the average rate for nuclear projects, they are similar to Vogtle 3 & 4. In projected future power markets, reductions in marginal cost may be more beneficial than those in investment costs.

0.16

Sustainability of TSFM Deployment and Pretraining: From Carbon Footprint Analysis to Mitigation via Pruning

cs.LG ·2026-10-23 ·Cécile Luc, Nathanaël Lemonnier, Ievgen Redko
publishedbenchmark similarity 0.50
Abstract · 26 pages, 6 figures, accepted at the NeurIPS 2026 Workshop TS-LIMITS

Time Series Foundation Models (TSFMs) offer strong zero-shot forecasting capabilities, but their high pretraining cost raises a practical sustainability question: does this upfront investment pay off over a full deployment lifecycle, compared to supervised standalone models that must be periodically retrained? We model the cumulative carbon cost of different approaches across a realistic industrial scenario: Chronos-2 amortizes its pretraining cost within months for large or frequently queried deployments, but a classical model remains cheaper indefinitely for small or rarely queried ones. For cases where reducing the TSFM's own cost matters, we show that removing a single encoder block (7.9% of parameters) via a gradient-free pruning criterion yields a consistent 6 to 9% reduction in FLOPs, CO2 emissions, and latency, at essentially no cost to zero-shot forecasting performance across a 25-task benchmark.

0.32

Modelling the Nordic power system expansion with PyPSA-Eur: a comparison with the Nordic Grid Development Perspective 2025

eess.SY ·2026-10-09 ·Leonardo Rydin Gorjão, Heidi S. Nygård
published similarity 0.49
Abstract · Conference proceedings, 4 figures, 6 pages

We compare the Nordic Grid Development Perspective 2025 (NGDP) with a least-cost transition pathway for the Nordic power system obtained with PyPSA-Eur for the period 2025-2050 under a net-zero CO$_2$ constraint. The model co-optimises generation, storage, and transmission expansion with hourly system operation while constraining the Nordic generation mix to remain consistent with NGDP milestone ranges. Overall, the optimised capacity pathways reproduce the broad NGDP expansion of wind and solar power, with Denmark emerging as the main locus of offshore wind and solar deployment, Finland as a major site for onshore wind expansion, and Norway and Sweden relying more strongly on existing hydropower and nuclear capacity. The main discrepancy between the two pathways does not lie in the broad build-out of variable renewables, but in the timing and role of hydrogen. Whereas the NGDP treats hydrogen as an early and steadily increasing component of industrial demand and system development already from 2030, PyPSA-Eur delays substantial hydrogen deployment until 2045-2050, when it becomes cost-effective primarily as a flexibility and seasonal storage option in a strongly variable-renewable-energy-dominated system. This contrast suggests that early hydrogen build-out in the Nordics is not a robust outcome of cost optimisation alone, but depends strongly on assumptions regarding industrial demand growth, sector coupling, and anticipatory infrastructure planning. We therefore argue that hydrogen remains the principal strategic uncertainty in the Nordic transition, with the NGDP representing a more anticipatory planning perspective and PyPSA-Eur a more conservative least-cost timing of deployment.

0.37

PyPSA-Libya: An Open-Source Energy System Model for National Decarbonization and Hydrogen Export Pathways

cs.CE eess.SY ·2026-10-28 ·Mohamed Abuella
code/data similarity 0.48
Abstract · 36 pages, 15 figures, 10 tables

Libya possesses significant renewable energy potential that remains largely untapped. This paper presents PyPSA-Libya, a national-scale model built on the PyPSA-Earth framework, designed to explore optimal transition pathways for the Libyan power sector. We present two primary studies: (1) an electricity-only capacity expansion analysis comparing a zero-emission constraint against an unconstrained baseline at 36-cluster resolution, and (2) a sector-coupled hydrogen export study evaluating the levelized cost of exporting 70 TWh/year of hydrogen to Europe under three technological scenarios and a 100 EUR/tonne CO2 carbon tax regime. Results indicate that while solar PV dominates the domestic capacity mix, integration of hydrogen production significantly alters grid storage requirements. Furthermore, under carbon pricing, steam methane reforming with carbon capture (SMR-CC) frequently out-competes pure green electrolysis, establishing a lower-cost compliance pathway for cross-border export. The model, data, and configuration files are released under an open-source license to support transparent energy planning in Libya.

0.34

Comparative Evaluation of MILP, MPC, and Reinforcement Learning for Commercial Battery Dispatch Under Time-of-Use Tariffs

eess.SY ·2026-09-13 ·Hafiz Majid Hussain, Wajiha Samar, Lurian Klein, Pedro Nardelli
benchmark similarity 0.46
Abstract

Battery energy storage systems (BESS) paired with rooftop photovoltaics (PVs) can deliver measurable cost savings under time-of-use (TOU) electricity tariffs; however, the relative performance of model-based and model-free dispatch strategies remains insufficiently benchmarked on full-year, real-world commercial datasets. This paper presents a full-year (2023) comparative evaluation of three BESS dispatch approaches using data from a commercial PV installation operating under a TOU tariff. The examined strategies include: (i) a mixed-integer linear programming (MILP) formulation with perfect foresight, providing an oracle performance benchmark under the assumed model; (ii) a model predictive control (MPC) scheme based on a day-ahead persistence forecast, representing a low-complexity deployable approach; and (iii) a soft actor-critic (SAC) deep reinforcement learning agent trained under causal information constraints. The MILP benchmark achieves an annual cost reduction of 24.6\% relative to a no-storage baseline. The persistence-based MPC approach recovers 99.2\% of this benchmark using only prior-day data. In contrast, the evaluated SAC agent yields an annual cost higher than the no-storage baseline. This outcome is analyzed in the context of known challenges in reinforcement learning for energy systems, including limited observability and reward design. Overall, the results indicate that, for the studied dataset and tariff structure, persistence-based MPC captures nearly all achievable economic benefits under practical deployment constraints, whereas the considered RL configuration does not yield competitive performance under the same information limitations.

0.21

Rethinking electrified transportation: The case for dynamic wireless charging

eess.SY ·2026-10-13 ·Dipanjan Ghose, Junjie Qin, S. Sivaranjani
similarity 0.46
Abstract

Long-term infrastructure investment often requires choosing between an established technology and a capital-intensive alternative that gains value as demand matures. For electric vehicle (EV) charging, this trade-off is between incumbent stationary charging technology and emerging dynamic wireless charging (DWC). DWC could fundamentally alter transportation electrification by enabling high-throughput charging in motion and reducing reliance on large onboard batteries; however, its high upfront cost makes the timing and location of deployment critical. Overcommitting to stationary charging stations (SCS) risks technological lock-in and forgoing the benefits of DWC, whereas premature DWC deployment can strand capital in underutilized corridors. Through a joint investment assessment framework coupling DWC, SCS, and supporting grid infrastructure across nearly 49,000 miles of the US Interstate freight network, we find that higher utilization and longer project lifetimes rapidly shift investment toward DWC, whose share rises sharply from 48% at a project lifetime of 30 years to 100% at 32 years. Contiguous DWC segments can share grid connections, enabling them to provide over six times the rated charging capacity of SCS while requiring 46% less investment in new distribution-grid infrastructure. We also find that a combined DWC and SCS portfolio reaches a maximum lifetime value of USD 60 billion, 63% above the case with only SCS. We further identify specific traffic demand, construction, and grid access conditions that shape where each technology becomes advantageous, yielding actionable thresholds for SCS and DWC deployment that directly inform long-term EV charging infrastructure investment and policy.

0.41