When Magnitude Suffices: Reconstructing Time-Domain-Gated Microwave Signals Without Phase on a Thoracic Phantom

Maciej Cichoń, Patrycja Gołaś, Maksymilian Bartosik, Angelika Walczak, Agata Bielecka-Dąbrowa, Maciej Ślot

cs.LG physics.app-ph ·submitted 2026-10-16 15:22 UTC · v1
unusual

Abstract

Time-domain gating separates the arrivals that form a microwave S-parameter measurement. It requires the measurement of complex values, so this application almost always uses a vector network analyzer (VNA). We show that, on one calibrated measurement configuration, the gated magnitude the VNA would give can be reconstructed from a magnitude-only sweep of a spectrum analyzer with a tracking generator (SA). We select the gate center for separability of the measured states, correct each instrument once by a per-bin subtraction of a reference state, and train a fully connected network on sweeps from both instruments. The test object is a torso phantom with lung-shaped compartments whose filling takes eleven dielectric states, each held out in turn. On $S_{11}$ the reconstruction from SA input reaches a shape error of 0.08 dB$^2$ with a state ordering of 0.81. This matches the reconstruction from VNA input. On $S_{21}$ it reaches 0.82 dB$^2$ and keeps the ordered groups of the states. An explicit phase prediction performs much worse, because gating needs the phase to about 0.2 rad RMS. Across eleven measurement configurations the dependence of phase on magnitude is strong for reflection and weak for transmission. This explains the difference between $S_{11}$ and $S_{21}$. Where the magnitude carries enough of the phase, a scalar instrument gives the gated response without any phase measurement after installation. On the open UM-BMID breast data set, with whole phantoms held out, the shape error of the network is 30 percent lower than that of a per-bin linear map.

Comment
18 pages, 7 figures, 4 tables

Closest papers

Nearest neighbours by meaning across the whole index.

Radar Waveform Design via Convex Semidefinite Relaxation

eess.SP math.OCmath-phstat.AP ·2026-11-15 ·Samuel Pinilla
code/data similarity 0.52
Abstract

The ambiguity function (AF) of a radar waveform describes its ability to resolve targets in range and Doppler. Designing a waveform that attains a prescribed AF magnitude is a phase retrieval problem with four trivial ambiguities, and a time- or band-limited pulse is determined up to these ambiguities by at most three times as many AF samples as it has time samples or frequencies. Existing solvers for the narrowband AF, however, are non-convex: they cannot guarantee that they reach the global minimizer, which is unique only up to the trivial ambiguities, so the recovered pulse depends on the starting point. This letter addresses this gap by lifting the problem to positive semidefinite matrices supported on the pulse band, where each AF sample becomes the magnitude of a linear functional. In the lifted space, recovery is formulated as a convex program, and a dual certificate provides a sufficient condition for exactness. The proposed algorithm, wavex, combines an initialization by relaxed reflections, convex semidefinite surrogate steps, and a local polish. Numerical experiments show that wavex accurately recovers band-limited pulses from complete AFs and from AFs with most of their samples removed, provided the remaining samples determine the pulse, and that its accuracy degrades gracefully as the noise increases. wavex is built on the open-source library invexapi, and the code that reproduces every result is available at https://github.com/samuelpinilla/waveX.

0.44

Kapture: Capturing Cardiac Dynamics with Koopman-Governed Learning for Efficient Radar-Based Electrocardiogram Recovery

eess.SP cs.AI ·2026-10-04 ·Tong Wu, Jing Peng, Ziqi Feng, Yuanyuan Zhang
code/data similarity 0.51
Abstract · 5 pages, 3 figures, 2 tables

Millimeter-wave (mmWave) radar enables unobtrusive, contactless electrocardiogram (ECG) reconstruction for cardiac monitoring. Time-frequency spectrograms preserve fine cardiac patterns but often require large backbones to separate ECG-relevant features from respiration, motion, multipath, and subject-dependent interference. We propose Kapture, a parameter-efficient Koopman-governed framework that projects radar hidden states into a low-dimensional observable space and identifies a regularized full linear evolution operator from adjacent observable states. The Koopman-predicted observables refine subsequent hidden states for ECG reconstruction. To suppress predictable interference dynamics, a temporal contrastive objective pulls neighboring states together and separates non-neighbors, while reconstruction supervision preserves task relevance. Using approximately 80 minutes of quasi-static radar-ECG recordings containing realistic noise from body movements and other sources, Kapture consistently improves reconstruction across matched backbone widths, with the largest gains under aggressive compression. The compact configuration approaches the full-width reference accuracy with 68.1% fewer parameters and 91.3% fewer profiler-covered floating-point operations (FLOPs), while the full-width configuration delivers the strongest overall reconstruction performance. Our code will be made publicly available after potential publication.

0.34

Learning to Assess Heartbeat Observability for mmWave Heart-Rate Sensing

cs.AI ·2026-10-02 ·Yuxuan Hu, Shilin Shan, Jianfei Yang, Feng Xu
code/data similarity 0.51
Abstract · 19 pages, 11 figures. Project page: https://yuxuanhu9.github.io/HEAR/

Contactless heart-rate sensing with millimeter-wave (mmWave) radar requires assessing whether individual measurements support reliable estimation. We study learning to assess heartbeat observability, defined as the readability of the heartbeat component in an acquired phase spectrum, for selective heart-rate estimation. Coherent superposition of scatterer returns can suppress this component even under similar macroscopic observation geometry, motivating assessment directly from acquired measurements. To obtain training supervision across different observability conditions, we develop a controllable multi-scatterer frequency-modulated continuous-wave (FMCW) simulator. Agreement between the dominant heartbeat-band peak and the known heart rate provides an automatic observability label for each simulated measurement. We propose HEAR (Heartbeat Estimation with Assessed Reliability), a compact dual-task Transformer that jointly predicts an observability score and heart rate. Its input combines spectral magnitudes with frequencies relative to the respiration fundamental, providing context for respiratory harmonics. Trained solely on simulated observations, HEAR transfers zero-shot to two public real-world datasets collected at 60 and 120 GHz from 134 subjects. The same learned score supports selective prediction with both HEAR's own heart-rate head and multiple existing estimators. On the 120 GHz dataset, score-based selection reduces the HR head's mean absolute error from 17.9 BPM at full coverage to 1.6 BPM at 50% coverage. The complete pipeline achieves an end-to-end processing latency of 50.8 ms on an edge device. Project page: https://yuxuanhu9.github.io/HEAR/.

0.38

RT-VSS: In-House Ray Tracing for Vital Signs Sensing in FR3 Band

eess.SP ·2026-09-14 ·Rudranil Chattopadhyay, Zhuangzhuang Cui, Achiel Colpaert, Sofie Pollin
similarity 0.50
Abstract · Submitted to the IEEE conference for potential publication

Vital Signs Sensing, enabled by the evolution of wireless communications, is inherently challenging as the chest's micro-Doppler signatures can be corrupted by multipath, body movement and noise. Additionally, the prospects of the Frequency Range (FR) 3 band, spanning 7-24 GHz, are compelling due to centimeter-scale wavelength improving phase sensitivity to chest motion, while its abundant bandwidth and rich multipath enhance temporal and spatial diversity. In this paper, we validate the feasibility of using cellular communications in the FR3 band to monitor a human's breathing and heartbeat in an indoor environment. Using Blender to model physiologically accurate vital-signs signals as ground truth and Sionna Ray Tracing simulations, we find that it is feasible to extract breathing and heartbeat waveforms at FR3 frequencies. Furthermore, we perform a comparative analysis of ISAC performance against representative sub-6 GHz (FR1) and mmWave (FR2) frequencies, indicating the utility of the study across the frequency bands.

0.26

Deeply unrolled alternating projections for phase retrieval

cs.LG stat.MLeess.SP ·2026-10-12 ·Jiayi Yao, Vasileios Charisopoulos, Rebecca Willett
position similarity 0.50
Abstract · 9 pages, 2 figures

Deep unrolling methods for inverse problems augment traditional reconstruction algorithms with learned priors to improve their performance. These methods have been developed under the implicit assumption that the geometry of the measurement operator does not change between training and deployment; when this is no longer the case, the quality of obtained reconstructions can degrade significantly. In this paper, we argue that this is not an inherent limitation of the deep unrolling paradigm and can be mitigated by a careful choice of the underlying iterative algorithm. We propose a deep unrolling framework for the phase retrieval problem that augments the alternating projections method with a learned denoising step. Our method obtains high-quality reconstructions without the need for retraining in settings where conventional model-based alternatives struggle, such as when the dynamic range of the measurement operator changes significantly at test time.

0.10

RMSampler: Sparse Radio Map Reconstruction with Active Sampling and Diffusion Posterior Correction

eess.SP ·2026-10-20 ·Nan Cheng, Xiucheng Wang
similarity 0.48
Abstract

Reconstructing a radio map (RM) from sparse received-power measurements supports non-cooperative interference monitoring and spectrum management. However,sparse measurements leave uncertainty about both the global RM and the interfering emitter location, making informative sampling and accurate reconstruction challenging. To address these challenges, a novel joint sampling and reconstruction method named RMSampler is proposed in this paper to improve measurement selection and RM reconstruction under limited measurement budgets. For measurement selection, RMSampler evaluates global RM error reduction using the covariance of diffusion-generated RMs and localization error reduction using candidate emitter locations. Because these errors have different units, their expected relative reductions are combined into a scale-invariant sampling criterion, with each acquired measurement updating both uncertainty estimates. After sampling, the updated emitter-location probabilities guide a separate conditional diffusion ensemble for final reconstruction. To improve measurement agreement, an effective sample size (ESS) target guides robust posterior correction, followed by a minimum-distortion projection enforcing measurement and building constraints. For the reconstruction ensemble, analysis establishes that increasing likelihood power reduces expected robust measurement loss, while pretrained neural parameters and architecture remain unchanged. Experiments using simulated and real-world measured data demonstrate improved reconstruction under matched measurement budgets. In the Chongqing real-world measured data experiment, root mean square error (RMSE) decreases from 3.54 to 2.73~dB relative to random sampling under a common reconstruction method.

0.39

VitalFR3: Wireless Vital Sign Sensing in the Upper Mid-Band (FR3)

eess.SP ·2026-10-03 ·Gholamreza Bakhshi, Hatem Abou-Zeid
similarity 0.48
Abstract · 14 pages, 12 figures

Frequency range 3 (FR3) is being explored for sixth-generation (6G) integrated sensing and communication (ISAC).However, experimental evidence on the feasibility of physiological sensing in this band is limited. This paper presents VitalFR3, an SDR-based frequency-modulated continuous-wave (FMCW) measurement platform that integrates a direct-sampling Ettus USRP X440 with a SignalCraft SC2470 frequency converter. To the best of our knowledge, this is the first calibrated SDRbased FMCW platform evaluated for respiration and cardiac-rate estimation from human measurements across multiple FR3center frequencies. Using a 100 MHz waveform, we operate the platform at six RF center frequencies from 10 to 22.5 GHz.We demonstrate how to characterize and calibrate the completeVitalFR3 transmit and receive path directly from loopback recordings, achieving a magnitude error below 0.061 dB at all six frequencies. We then propose a low-complexity end-to-end processing pipeline for vital sign estimation. This involves the identification of a persistent target-associated response in fast time, respiratory tracking in slow time, followed by cardiac- rate estimation. The system is evaluated across 16 human measurements, achieving a respiratory-rate mean absolute error of 0.758 breaths per minute, and the majority of the cardiac- rate estimates fall within 5 BPM of their reference rates. In a separate breath-hold measurement, the estimated cardiac rate is 84.3 BPM versus approximately 84.5 BPM from the reference. These results establish VitalFR3 as a calibrated and configurable measurement platform for experimental physiological sensing across FR3.

0.18

Bounds on Shaping Partially Coherent Microwaves with Programmable Scattering Systems

eess.SP physics.app-ph ·2026-08-31 ·Philipp del Hougne
similarity 0.47
Abstract · 15 pages with 3 figures

We derive bounds on manipulating partially coherent microwaves with programmable scattering systems. We first consider the concentration of power from a partially coherent input into a single output port and derive a prototype-aware bound by combining multiport network theory (MNT) with semidefinite relaxation (SDR). We then address general coherency-matrix synthesis, deriving architecture-independent bounds on fidelity and useful strength, prototype-specific scalar refinements thereof, and fully prototype-aware SDR bounds on the useful-strength--fidelity Pareto frontier. The prototype-aware formulations account for mutual coupling, loss, discrete tunability, and static scattering. We evaluate the bounds on four experimental RIS-parametrized MIMO systems with up to 100 1-bit-programmable elements, using proxy-MNT models estimated from measurements. The resulting bounds are generally tight compared with feasible discrete-optimization outcomes. Interestingly, for coherency synthesis, the simpler bounds can in some cases be tighter than the fully prototype-aware bounds, highlighting their complementarity. Our results provide certified limits for wave-domain processing and harvesting of partially coherent microwaves.

0.48