CS Paper Radar

VeriCalib: Verifiable Target-Based LiDAR-Camera Calibration

Xiangcheng Hu, Xieyuanli Chen, Feiyi Chen, Shengli Ren, Shiyang Chen, Guoqiang Ye, Hao Wang, Ping Tan, Steven L. Waslander, Fuchun Sun, Jin Wu

cs.RO ·submitted 2026-10-20 18:21 UTC · v1

Abstract

Target-based extrinsic calibration estimates the rigid transform between sensors from a few observations of a known target, and its result is commonly assessed by the root-mean-square error of the fitted residuals. However, this scalar error is computed on the same observations and therefore cannot indicate whether to accept the result, re-extract, recollect or add observations. This paper presents VeriCalib, which formulates extrinsic calibration as a verifiable estimation problem and reports a calibration state. The key insight is a two-level extrinsic compensation mechanism, in which the extrinsic compensates the rigid part of each observation error at the residual level, and rotation and translation compensate each other at the parameter level. Consequently, the fitted residual can reveal neither an inconsistency between the observations and the model nor whether the estimated extrinsic is reliable in every direction. Accordingly, we assess the calibration through a structured covariance that jointly propagates the uncertainty of the camera and LiDAR board features with a known-geometry prior, and estimate its scale as a variance component from the residuals. On this covariance, we decouple rotation and translation to resolve the precision along each direction and guide data collection toward the weakest one. Since this precision presumes consistent observations, we further develop within-view and cross-view checks that examine the internal residual and the rigid discrepancy between observations, respectively, with thresholds that hold their significance level under an unknown noise level. We also extend the minimal detectable bias to the extrinsic to bound the smallest detectable fault along each direction. These criteria form a calibration state that indicates whether to accept the result or how to collect the data...

Comment
35 pages, 20 figures, 13 tables

Closest papers

Nearest neighbours by meaning across the whole index.

MiCaDe: Online LiDAR-Camera Miscalibration Change Detection for Autonomous Driving

cs.CV cs.LG ·2026-11-03 ·Carlo Sgaravatti, Riccardo Pieroni, Matteo Corno, Sergio M. Savaresi, Luca Magri +1 more
code/datahot direction similarity 0.74
Abstract

Reliable multi-sensor perception in autonomous vehicles requires accurate calibration between cameras and LiDAR. However, calibration drift is often unavoidable in long-term deployments: vibrations, thermal effects, and minor mechanical shocks may alter the relative pose between sensors, leading to systematic errors in downstream fusion tasks. We propose MiCaDe (Miscalibration Change Detection), an online solution detecting when the extrinsic LiDAR-camera calibration parameters are no longer accurate by means of sequential change detection. MiCaDe requires no calibration targets, or modification of the perception stack, providing low false-alarm rates with negligible computational overhead. Our key insight is that 3D and 2D bounding boxes produced by standard object detectors should remain geometrically consistent under correct calibration. By matching cross-modal detections, we derive geometric consistency metrics that serve as sensitive indicators of extrinsic drift. These metrics are aggregated into fixed-size batches and scored against a reference distribution, producing a likelihood stream that is monitored by a Change Point Model (CPM). Crucially, the CPM accumulates statistical evidence over time, enabling detection of subtle drifts that would otherwise go unnoticed. Experiments on multiple long-sequence datasets and on a real-world dataset with physically induced miscalibration confirm reliable detection under diverse conditions. Code available at: https://github.com/CarloSgaravatti/MiCaDe.

0.35

Extending Ground-Constraint LiDAR-IMU Calibration to Tilted Surfaces in a Continuous-Time Framework

cs.RO ·2026-08-25 ·Vassili Korotkine, Pierre Chamoun, Mohammed Ayman Shalaby, James Richard Forbes
code/data similarity 0.71
Abstract · 8 pages, 13 figures. Submitted to Robotics & Automation Letters

This paper presents a novel method that extends targetless LiDAR-IMU calibration for ground vehicles to non- flat environments. Calibration typically necessitates full exci- tation of the sensor rig, a requirement that is not fulfilled by ground vehicles in normal operation. To address the degenerate planar motion, state-of-the-art methods propose residuals that assume the colinearity of the gravity and physical surface normal vectors, restricting usage to cases where the ground is assumed flat. This paper proposes ground-plane residuals that do not require this assumption, and are applicable for planar motion on a tilted surface. Results are demonstrated on a dataset collected from a Husky ground vehicle, on the M2DGR dataset, as well as on an offroad vehicle dataset. Repeatability is shown to be improved both in tilted and flat-ground scenarios, with strong improvement demonstrated for the tilted case. The implementation and experiments are open-sourced at https://github.com/vkorotkine/licalib_tilted_ground.

0.43

Temporal-Aware Fusion for Robust Outdoor LiDAR Localization

cs.CV ·2026-09-29 ·Minghang Zhu, Zhijing Wang, Yuxin Guo, Chen Liu, Yongshu Huang +3 more
top venue similarity 0.71
Abstract · 10 pages, 8 figures, 6 tables, conference

LiDAR relocalization aims to estimate the global 6-DoF pose of a sensor in the environment. However, existing regression-based approaches often encounter limitations in dynamic or ambiguous scenarios, as they typically prioritize single-frame inference, leaving the potential of spatio-temporal consistency across scans not fully explored. In this paper, we propose a Temporal-aware Localization framework (TempLoc) designed to enhance the robustness of outdoor localization by effectively modeling sequential consistency. Specifically, a Global Coordinate Estimation module is first introduced to predict point-wise global coordinates and associated uncertainties for each LiDAR scan. A Prior Coordinate Generation module is then presented to estimate inter-frame point correspondences by the attention mechanism. Lastly, an Uncertainty-Guided Coordinate Fusion module is deployed to integrate both predictions of point correspondence in an end-to-end fashion, yielding a more temporally consistent and accurate global 6-DoF pose. Experimental results on the NCLT and Oxford RobotCar benchmarks show that our TempLoc outperforms state-of-the-art methods by a large margin, demonstrating the effectiveness of temporal-aware correspondence modeling in LiDAR relocalization.

0.30

CalibSwitch: Observation-Driven Camera-LiDAR Extrinsic Recovery and Selective Maintenance for Multimodal Perception

cs.RO cs.CV ·2026-10-30 ·Haifa Zhang, Yijing Wang, Zhiqiang Zuo
similarity 0.70
Abstract

Camera--LiDAR perception on mobile robots and intelligent vehicles depends on reliable sensor geometry throughout deployment. Installation variations create uncertainty in the initial extrinsics, while changing observation quality makes frame-wise estimates fluctuate during operation. This paper presents CalibSwitch, an observation-driven framework that separates absolute extrinsic recovery from selective state maintenance. A cross-modal absolute extrinsic generator (CAEG) combines projection-free bidirectional feature interaction with geometry-regularized learning to recover complete SE(3) candidates from image--point observations and coarse view context, without a supplied numerical initial transform. A selective recurrent calibration policy (SRCP) combines observation quality and temporal history to determine when a candidate should replace the working geometry consumed by a frozen multimodal detector. On nuScenes, CAEG achieves mean translation and rotation errors of 0.248 m and 5.884$^\circ$. Under sustained geometric transitions, SRCP reaches a mean composite error of 1.46 with 9.70\% candidate commitments, outperforming quality-based and temporal-consistency gating at comparable commitment rates. Relative to unconditional per-frame updating, it improves frozen-detector mAP and NDS by 1.43 and 0.92 points. Paired geometry--observation uncertainty tests, two real-vehicle platforms, and 13.5-FPS single-camera Jetson execution demonstrate the system value of selective geometric-state maintenance for continuous perception.

0.16

Auditing Targetless Camera-LiDAR Extrinsic Correction before Recursive Use

cs.CV ·2026-11-03 ·Bo Ma, Weiqi Yan
hot direction similarity 0.69
Abstract

Camera-LiDAR fusion repeatedly uses an extrinsic transform in projection, association, and recursive state estimation. We study whether a targetless correction should be admitted to a downstream consumer only after separate audits of correction quality, confidence ranking, and recursive risk. Our log-disjoint protocol evaluates these stages under synthetic extrinsic drift on Argoverse 2 and treats cross-dataset and odometry experiments as bounded diagnostics. On 27 test-split logs, single-frame Canny alignment is harmful in the mild tier. Multi-frame alignment improves severe-tier rotation by 2.52 degrees but worsens translation by 0.177 m; its declared joint error-magnitude improvement is also negative (-0.158, 95% CI [-0.223, -0.098]), so the rotation gain is not a six-degree-of-freedom correction success. A zero-injection check moves away from the true extrinsic, and solver-disagreement AUROC on selected splits does not yield a validated nonzero-coverage risk-coverage operating point. In a 15-log final system role, the locked conservative policy admits no candidate and equals Raw, whereas Always-correct increases trajectory error. These results support an auditable separation of correction, confidence, and recursive contamination; they do not establish a deployable calibration gate, positive odometry or SLAM improvement, map consistency, or closed-loop safety.

0.28

P$^2$Calib: Utilizing Pattern Priors for LiDAR-Camera Extrinsic Calibration

cs.RO ·2026-09-07 ·Xiangcheng Hu
similarity 0.68
Abstract · 12 pages, 10 figures

Target-based LiDAR-camera extrinsic calibration is a prerequisite for multi-sensor fusion in robotics. However, in the widely adopted four-hole pipeline, \rt{calibration accuracy is limited by hole-center extraction in the LiDAR side, where sparse angular coverage and mixed-pixel returns displace the estimated centers}. This paper presents P$^2$Calib, which exploits \textit{pattern priors}, geometric constraints specified by the CAD model of the target board, to improve calibration accuracy. First, we incorporate the known hole radius as a fitting constraint to prevent center estimates from degrading under sparse angular coverage. Building on the improved hole estimates, we further enforce the rigid rectangular layout of the four holes as a global consistency constraint to correct residual errors across holes. Both priors are integrated into an \rt{interactive tool that runs the pipeline from target detection to the final extrinsic}. Experiments on simulated and real datasets show that P$^2$Calib reduces the joint registration residual by 90\% and 82\% and the held-out reprojection error by 96\% and 77\% over the baseline. \rt{We will release the code and data\codelink{} to facilitate future research.

0.51

Can a Display Be Used for Rapid LiDAR-Camera Extrinsic Calibration?

cs.CV ·2026-10-20 ·Zuhao Zou, Xiangcheng Hu, Jianhao Jiao, Jin Wu
benchmarkcode/data similarity 0.67
Abstract

ScreenCalib enables light detection and ranging (LiDAR)--camera extrinsic calibration using an ordinary programmable display, providing known visual markers and controlled geometry while reducing dedicated target preparation. The camera observes displayed AprilTags, whereas the LiDAR measures the physical screen surface and boundary, requiring indirect cross-modal association. Display geometry introduces association ambiguities, while indoor clutter complicates extraction. ScreenCalib addresses these challenges through tag-guided display extraction, geometric hypothesis generation and refinement, and surrounding scene edges for ambiguity resolution. The single-pose mode requires only one static placement. The joint multi-pose mode combines independent static observations through cross-pose consensus and jointly refines the shared extrinsics and tag scale, reducing sensitivity to tag-size measurement errors without requiring continuous motion or inter-pose trajectory estimation. Experiments in simulation and on three different sensor platforms cover mechanical and nonrepetitive LiDARs in clean and cluttered environments. Benchmark results show that ScreenCalib outperforms competitive calibration-board-based methods in translation accuracy. Joint multi-pose refinement further reduces mean rotation and translation errors across the three platforms and improves rendered-map alignment. Evaluation across readily available displays, including cell phones, tablets, laptops, computer monitors, and televisions, further examines ScreenCalib's versatility as a practical alternative to dedicated calibration targets. The source code is available at https://github.com/ZuhaoZou2026/ScreenCalib.

0.23

Generalizable Target-Less Joint Intrinsic-Extrinsic Camera-LiDAR Calibration using Deep Pixel-Point Correspondences

cs.RO ·2026-10-27 ·Simon Bultmann, Daniele Cattaneo, Abhinav Valada
similarity 0.66
Abstract · 8 pages, 5 figures

Accurate camera-LiDAR calibration is an essential prerequisite for robust multi-modal perception in robotics. Recent target-less methods based on learned pixel-point correspondences achieve high extrinsic calibration accuracy and generalize across environments. However, they operate on rectified images with known camera intrinsics, restricting their applicability to systems whose cameras have already been individually calibrated. We present a fully automatic, target-less framework that jointly estimates camera intrinsics, radial-tangential distortion, and camera-LiDAR extrinsics from raw images and LiDAR scans. Our method generalizes deep correspondence-based calibration from rectified images to raw cameras through intrinsic- and distortion-aware correspondence learning via synthetic augmentations. During calibration, we iteratively couple correspondence prediction and nonlinear optimization to jointly refine the camera parameters and relative sensor transformation. We evaluate our approach on an unseen camera-LiDAR configuration from the KITTI dataset and on three real robotic platforms in a zero-shot manner. The results demonstrate that joint calibration with our generalized pixel-point correspondence network improves extrinsic accuracy over correspondence-based methods using pre-calibrated cameras, while additionally recovering accurate intrinsics.

0.20