CS Paper Radar

VecTile: A Low-Cost Flexible Tactile Array for 3-DoF Force Sensing

Jian Hou, Xin Zhou, Adam J. Spiers

cs.RO ·submitted 2026-10-22 16:00 UTC · v1

Abstract

Tactile sensing provides robots with contact information difficult to obtain from vision alone. Shear force is particularly important for understanding tangential contact, guiding corrective motions, and maintaining grasp stability, yet flexible and low-cost tactile arrays often measure only normal force. We introduce VecTile, a low-cost, 6 mm thin, flexible tactile array capable of three-axis force sensing. VecTile combines a piezoresistive layer with passive silicone nubs that convert normal and shear forces into distinguishable pressure patterns. The sensor can be fabricated in-house without specialized equipment. The complete system costs less than 35 USD for a 4x4 array. We validate the sensing mechanism through finite element analysis and hardware experiments. In controlled single-taxel tests over 1-5 N normal force and up to 1.5 N shear force, VecTile achieves root-mean-square errors of 0.39 N and 0.16 N for normal and shear forces. A VecTile calibrated while flat retains accuracy when curved, while a five-minute manual calibration is sufficient for practical use. Two applications demonstrate its utility. First, shear readings are sensitive enough to stop a sharp scalpel from puncturing a balloon after contact. Second, the sensor substantially improves Diffusion Policy-guided power-plug insertion. All designs and code will be released upon paper acceptance. Project website: https://jiannnh.github.io/VecTile/.

Comment
8 pages, 8 figures. Submitted to IEEE International Conference on Robotics and Automation (ICRA) 2027

Closest papers

Nearest neighbours by meaning across the whole index.

PanoTac: A Dense Three-Axis Tactile Sensor for Robust Touch-Centric Manipulation

cs.RO cs.AIcs.LG ·2026-11-02 ·Binglin, Wang, Xiaole, Jiang, Zicheng Teng +5 more
code/data similarity 0.73
Abstract · Project page: https://panotac.github.io

Contact-rich manipulation benefits from tactile feedback that captures both detailed contact geometry and interaction forces. When scooping grains, contact patterns help infer spoon orientation, while resistance transmitted through the grasp guides motion. To provide these complementary sensing capabilities, we present PanoTac, a low-cost, compliant tactile fingertip designed for dense three-axis tactile sensing. Each fingertip provides a $12 \times 32 \times 3$ tactile representation, with one normal ($z$) and two shear ($x$, $y$) response components at each taxel. The sensor operates at 60 Hz and costs less than $50 per fingertip. Sensor characterization quantifies response repeatability and consistency across sensor instances and contact locations. We integrate PanoTac into a robotic system with a visuo-tactile pipeline. Across test-tube preparation, grain scooping, and salt pouring, the resulting policies outperform vision-only baselines by an average of 46.7 percentage points. Ablations show that removing either spatial contact information or shear feedback reduces overall performance across the task suite. Our project page is available at https://panotac.github.io.

0.19

Tactile Reconstruction of Contact Task Frames and Forces for Hybrid Force/Motion Control

cs.RO ·2026-10-07 ·Antonio Rapuano, Simone Orelli, Barbara Bazzana, Antonio Franchi, Alessandro De Luca
similarity 0.70
Abstract · 14 pages, 9 figures, 7 tables. Video: https://youtube.com/playlist?list=PLejKMZmW8AvI. Dataset: https://doi.org/10.5281/zenodo.23209032

Hybrid force/motion control requires knowledge of the interaction force and of a task frame defining the force- and motion-controlled directions. These quantities are usually obtained from force/torque sensing or model-based residuals, often assuming also a nominal environment model. This work addresses the online estimation of the contact force and a possibly time-varying task frame using only soft optical tactile sensing, under the assumption of locally planar contact with a negligible contact moment. The proposed method maps a single image of the deformed elastomer of a soft optical tactile sensor to observable contact variables: indentation depth, two surface-to-sensor tilt angles, and 3D contact force, each with a per-sample uncertainty estimate. The mapping is learned through a self-labeling acquisition procedure, in which a manipulator imposes controlled contacts while an auxiliary Force/Torque sensor is used offline to provide ground-truth labels. The tactile measurement is then fused with robot proprioceptive data in an Extended Kalman Filter, producing a continuously updated estimate of the contact task frame and of the interaction force. Control experiments with a DigiTac sensor mounted on a UR10 manipulator demonstrate closed-loop contact force regulation against a flat rigid board in linear and angular motion by a human operator, with touch as the only exteroceptive feedback.

0.23

Hall Effect-Based Tactile Force Detection Sensor for Robot-Assisted Minimally Invasive Surgery

cs.RO ·2026-10-07 ·Charles DeLorey, Michael Brockdorff, Adam Metcalf, Benjamin Calmé, Pietro Valdastri +1 more
similarity 0.69
Abstract · 9 pages, 12 figures

Robotic minimally invasive surgery has revolutionized surgical practice. However, as the surgeons are mechanically separated from the surgical tools, loss of tactile feedback occurs. We present a compact force sensor with three, millimeter scale sensing elements (taxels) that can be affixed to the grasping face of a robotic surgical tool. The sensor features a miniaturized design using Hall effect sensors and magnets embedded in a deformable elastomer contact layer. Sensor calibration is achieved with a 6 degree of freedom (DoF) parallel robot. Each taxel can detect applied normal and shear forces with average RMSE of 2.133 kPa. The calibrated sensor was validated on phantom and ex vivo porcine tissue, demonstrating tactile sensing during retraction as well as slip. This work introduces a small-scale Hall effect based tactile sensor, enabling sensing for force-sensitive robotic surgical applications.

0.17

Layered e-skin for Shear Sensing

cs.RO ·2026-09-18 ·Qingzheng Cong, Alexis W. M. Devillard, Abu Bakar Dawood, Xinxin Zhang, Wen Fan +5 more
similarity 0.68
Abstract · 8 pages, 5 figures. Submitted to IEEE Sensors Journal

This paper presents a stacked two-layer force-sensing resistor (FSR) array designed for robotic fingertips that combines high-resolution pressure mapping with shear-force estimation. A compliant lattice elastomer spacer converts shear loading into a measurable inter-layer displacement, producing relative center-of-pressure (CoP) shifts between layers. A physics-based moment balance links inter-layer CoP displacement to shear force, while an end-to-end CNN--GRU model captures nonlinear effects from load-dependent compression and contact redistribution. This model, with both layers as input, achieves coefficients of determination $R^2 = 0.914$ for $F_x$ and $R^2 = 0.944$ for $F_y$, consistently outperforming single-layer baselines for shear-force estimation. Robotic manipulation experiments show that, for contact-motion tracking, the deep layer tracks the translation and rotation imposed by the robot arm, whereas the superficial layer tracks the slip at the contact surface. Transient changes in the difference between the total pressure responses of the two layers provide the best slip-event detection performance among the tested cues. These results demonstrate that two-layer FSR arrays can provide three-axis force estimation, contact-motion tracking, and slip-event detection beyond conventional normal-force sensing.

0.32

OpenTac: An Open Ecosystem for Customizable, Scalable, and Transferable 3D Tactile Sensing

cs.RO eess.SPeess.SY ·2026-10-22 ·Ariel Slepyan, Geeta Chandra Raju Bethala, Jiafeng Gu, Anagha Rajendra Dangle, Yinzhe Zhou +10 more
code/data similarity 0.67
Abstract · 15 pages, 15 figures. Project website, open-source hardware and software, and demonstration videos: https://opentac.github.io

We present OpenTac, a novel sensor and a full-stack ecosystem for tactile skins that are highly customizable, scalable, and readily deployed in downstream robot control and learning applications. Our core contribution is twofold. First, we develop a scalable resistive tactile skin with a structured deformable overlay that converts tangential loading into spatially varying pressure. Differential responses across neighboring "taxels" support decoding of local shear vectors, and the common-mode response encodes normal force. Second, we provide a highly customizable sensor design tool that is able to automatically generate fabrication files for these tactile skins from 2D outlines and developable 3D surfaces, including from abstract descriptions such as text. We develop an ecosystem around the OpenTac sensor, including the CAD design tool, a sensor simulator, cross-sensor transfer, and fast/adaptive data acquisition. We demonstrate the broad applicability of the OpenTac-CAD sensor design tool by designing and fabricating more than 30 sensors across a variety of robot embodiments. We characterize the three-dimensional tactile fields produced by OpenTac with a commercial, high-precision force/torque sensor. We demonstrate the broad applicability of 3D tactile sensing across contact-rich feedback control and manipulation policy learning on four real-world robot embodiments. Additionally, adaptive acquisition enables kilohertz-rate partial readouts, and our readout circuitry enables high dynamic range (HDR) acquisition, measuring, for example, a 3.7 kg weight stack and a 20 g weight on the same sensor in the same frame. We provide all hardware, software, and result videos at opentac.github.io

0.21

GlowTact: Simple and Compact Vision-Based Tactile Sensing with High Sensitivity and Spatial Resolution

cs.RO ·2026-09-26 ·Yuxiang Ma, Megha Tippur, Pengfei Ye, Sandra Q. Liu, Haonan Chen +2 more
similarity 0.66
Abstract · Project webiste: https://glowtact.github.io/

Vision-based tactile sensors (VBTS) provide rich contact information for robotic manipulation, but existing designs can be hard to simplify and adapt to the size and constraints of humanoid fingertips. We introduce \textbf{GlowTact}, a pressure-responsive vision-based tactile sensing mechanism that directly visualizes contact pressure. \textbf{GlowTact} requires only single-color, non-directional illumination, and the raw tactile image directly represents the pressure distribution without explicit geometry reconstruction. This simple sensing principle enables compact, customizable tactile sensors while preserving high sensitivity and rich spatial detail. We demonstrate gram-scale contact detection, accurate normal-force estimation, and reconstruction of fine contact geometry, including M1 screw threads. These results establish \textbf{GlowTact} as a practical new sensing technology for compact humanoid fingertips, combining a durable nitrile membrane and simple optical design with sensitive and information-rich tactile perception.

0.29

LumiTac: Compact, High-Rate Six-Axis Optical Tactile Sensing for Human-Robot Interaction

cs.RO ·2026-11-04 ·Hao Wu, Haotian Guo, Yu Feng, Yutong Wang, Jianshu Zhou
similarity 0.64
Abstract

Integrating six-axis tactile feedback into robotic interfaces requires compact sensors with accurate load measurement and rapid online reconstruction. This paper presents LumiTac, a low-profile, camera-free optoelectronic tactile sensor combining spatially distributed illumination with spectral encoding. Five photoemitters and five RGBW photoreceivers are mounted on opposing circuit boards coupled through translucent silicone. Load-induced interlayer motion modulates the internal light field under compression, shear, bending, and torsion. The sensing head measures 12 mm in diameter and 4.75 mm in thickness, weighs less than 2 g, and has a component cost of approximately USD 7. A compact multilayer perceptron reconstructs three force and three moment components from 20 optical channels. Independent testing yielded coefficients of determination (R-squared) of 0.9657-0.9941, with mean absolute errors of 0.054-0.190 N for forces and 0.304-1.419 mN m for moments. Online prediction achieved an average update rate of 303.57 Hz and a median software processing latency of 0.722 ms. Experiments involving combined loading, light weights, and rapid tapping evaluated load tracking, sensitivity to small forces, and transient response, respectively. Robotic demonstrations further validated its applicability to tactile-guided manipulation and physical human-robot interaction. This study paves the way for compact, high-rate optical tactile sensing in robotic manipulation and human-robot interaction.

0.45

Tactile Perception through Fluid-Solid Interaction

cs.RO cond-mat.soft ·2026-09-29 ·Arman Goshtasbi, Minke Berghuis, Aida Parvaresh, Saravana Prashanth Murali Babu, Robert W. Style +1 more
top venue similarity 0.64
Abstract

Soft tactile sensors elevate robotic touch through enhanced flexibility and adaptability, yet most existing designs depend on embedded electronics that are susceptible to interference and environmental limitations. In this work, we leverage fluid-solid interactions to develop a class of soft tactile sensors that operate entirely without electronics at the sensing site. The sensor comprises a fluid-filled elastomeric channel connected to only two external pressure sensors. Touching different regions of the elastomeric surface displaces the viscous fluid, producing distinct pressure patterns that encode both touch position and force. These signals are decoded through a machine learning framework that integrates feature extraction, soft clustering, and adaptive neuro-fuzzy inference to achieve accurate localization and force estimation. We validate this concept through single-point touch localization and force estimation in a linear (1D) sensor and extend the same sensing principle to 2D tactile mapping by routing the channel across the surface using space-filling curves, while maintaining the same minimal hardware setup. This simple approach remains effective in environments where conventional electronic sensors often fail, such as underwater or in the presence of magnetic interference.

0.57