CS Paper Radar

Thermal-Headroom Routing for Efficient Robot Perception in Extreme Heat

Sparsh Roy, Kevin Zhou, Arhaan Shah, Shreyan Garg, Vihaan Joshi-Apte, Maxim Kudryashov, Nanda Cheruvanthala

cs.RO cs.CVcs.PF ·submitted 2026-10-26 11:20 UTC · v1
code/data

Abstract

Adaptive robot perception systems must balance detector accuracy, inference latency, and energy consumption, particularly when high ambient temperatures cause processors to thermally throttle. We propose Thermal-Headroom Routing (THR), a lightweight model-selection policy that forecasts processor temperature using a closed-form RC thermal model and excludes detector configurations predicted to cross a throttling threshold. We evaluate THR with four YOLO11 configurations across seven real-world perception traces, eight ambient temperatures, and 20 randomized seeds, comparing it with latency-aware routing, fixed-threshold thermostats, duty caps, and a matched-compute-budget control. At ambient temperatures of 45-55 degrees C and a tight inference deadline, THR eliminates throttling in simulation, reduces deadline misses by 3.9-7.5 percentage points, and reduces energy per on-time frame by approximately 12-13% relative to a latency-belief router. A separate experiment using deadline-paced, nonoverlapping frame execution yields miss-rate reductions of 6.2-9.5 percentage points. A tuned thermostat or duty cap can match THR at a fixed operating point; predictive routing is most useful when ambient conditions or calibrated thermal parameters differ from those used to tune static policies. Measurements on an Apple M5 support the single-node heating approximation but do not validate hardware throttling. The results characterize the conditions under which thermal forecasting improves the efficiency and timeliness of resource-constrained robot perception.

Comment
9 pages, 5 figures, 11 tables. Code and experimental outputs: https://github.com/ImSpxrsh/thermal-headroom-routing {Submitted IEEE Big Data}

Closest papers

Nearest neighbours by meaning across the whole index.

Sustainable Edge Vision via Empirically Calibrated DVFS: Eliminating Thermal Throttling on Passively Cooled Hardware

cs.AR cs.CVcs.LG ·2026-09-04 ·Aayush Marasini, Zhaoxian Zhou
code/data similarity 0.68
Abstract · 7 pages, 5 figures, 8 tables, Code, datasets, and frozen artifacts available at: https://github.com/Aayush-Marasini/sustained-edge-vision

Passive cooling eliminates the energy overhead and mechanical failure modes of fans, making it attractive for edge deployment, yet sustained Deep Neural Network (DNN) inference on passively cooled edge Systems-on-Chip (SoCs) is bottlenecked by thermal throttling. To address this, we propose an empirically calibrated, state-aware Dynamic Voltage and Frequency Scaling (DVFS) scheduler. Unlike heuristic-driven controllers, our methodology utilizes time-domain guards and absolute temperature bounds, with derivative triggers acting as safeguards against sharp thermal spikes. Evaluated on a passively cooled Raspberry Pi 5 running YOLOv8n, our scheduler eliminates all observed thermal throttling events during sustained 30-minute workloads. It outperforms a temperature-only reactive baseline by achieving a 6.8% higher frame rate (Cohen's d = 8.73) while consuming 1.9% less energy per frame. Furthermore, our optimized passive scheduling surpasses an actively cooled reference system in energy efficiency (Joules/frame), though active cooling remains superior for raw throughput. Through isolated ablations, we show that the dwell guard is necessary for run-to-run reproducibility. Finally, exploratory boundary probes indicate that the passive operating envelope closes at ambient temperatures ($\ge 27^\circ$C) where nonlinear leakage defeats DVFS-based control. These results indicate that, within the mapped envelope, correct scheduling can make mechanical cooling unnecessary for sustained edge inference on this platform.

0.37

ThermE: Predictive Management of Shared Thermal Headroom for Sustained LLM Inference on Thermally Constrained Edge SoCs

eess.SY ·2026-09-24 ·Rui Lu, Yuheng Wang, Bozheng Liu
similarity 0.67
Abstract · 13 pages, 16 figures

Compact edge system-on-chip (SoC) platforms increasingly run sustained LLM inference under thermal constraints, while their CPU, GPU, and RAM share a cooling path. Prefill and decode therefore consume shared, time-varying thermal headroom, yet vendor governors react only near hardware throttling thresholds without knowledge of request state or upcoming work. A control decision that improves current performance can thus consume headroom too quickly and degrade subsequent service. In this paper, we present ThermE, a runtime system that predicts and jointly manages shared thermal headroom for sustained LLM inference on edge SoCs. Its Fast LLM-to-Heat Compiler maps the model, requests, runtime state, and candidate actions to domain heats without executing LLMs. A partial differential equation (PDE)-constrained Headroom Predictor uses ThermPINN for offline thermal identification and a Reduced Headroom Predictor (RHP) for low-overhead online uncertainty-calibrated headroom forecasts. An Uncertainty-Aware Action Scheduler then selects actions that balance serving quality and future headroom. We implement ThermE atop vLLM and evaluate it across four LLM inference workloads. The results show that ThermE reduces TTFT and TPOT by 40.55% and 12.17%, respectively, relative to vLLM. It achieves a 5.70% SLO violation rate, compared with 12.30% for the strongest baseline, while its predictor obtains a 1.94 $^\circ$C MAE with 11.50 ms overhead.

0.09

ETCInfer: An Energy-efficient Thermal-aware Cooling-joint Scheduler for LLM Inference in AI Datacenters

cs.DC cs.PFeess.SY ·2026-09-14 ·Rui Lu, Rui Ge, Huanghuang Liang, Xiaobo Zhou, Dan Wang
similarity 0.66
Abstract · 16 pages

Large language model (LLM) inference in AI datacenters creates a coupled control problem between GPU serving and facility cooling. Raising ambient temperature setpoints can reduce cooling energy and carbon, but also shrinks thermal headroom, induces GPU throttling, and leads to Service-Level-Objective (SLO) violations. In this paper, we study joint cooling--computing control for LLM inference: minimizing per-job GPU-plus-cooling energy while satisfying thermal safety and latency SLO constraints. We present ETCInfer, an energy-efficient, thermal-aware scheduler that selects a pre-job Computer Room Air Conditioner (CRAC) setpoint and adapts per-GPU frequency and micro-batch size during execution. ETCInfer builds compact physics-informed control models by calibrating GPU heat generation, chassis heat dissipation, CRAC power, and prefill/decode latency relations from telemetry. These models estimate hidden thermal states and time-to-throttle, enabling the scheduler to evaluate energy, temperature, and latency before applying an action. We formulate this joint setpoint--frequency--micro-batch control problem as a partially observable Markov decision process and design ETCAdapter, a learning-based controller that minimizes per-job energy under thermal safety and SLO constraints. We implement ETCInfer as a coordination layer over typical inference and cluster management stacks. Evaluation across real-trace simulation and validation experiments shows that ETCInfer reduces total job energy by up to 33.1%, thermal throttle exposure by up to 92.9%, and keeps SLO violation rates below 0.7% even at ambient temperatures up to $48^{\circ}\mathrm{C}$.

0.17

TRR: A Thermal Interaction Engine for Robot Simulation and RGBT Data Generation

cs.CV cs.RO ·2026-11-16 ·Biwen Yang, Zhe Cao, Jin Zhang, Haoyang Sun, Zonglu Hu +7 more
benchmarkcode/data similarity 0.65
Abstract

A robot's actions change the thermal conditions of its next interaction: heat retained after release, carried with objects or stored beneath the surface can change a later contact's outcome despite similar current temperatures. Training trajectories must capture how these effects connect earlier actions to later observations and task outcomes. We present TRR, a \emph{Thermal Robot Renderer} that attaches spatial and depth-resolved thermal state to both contact partners, updates local heat exchange through contact, transport and separation, and generates synchronized RGB--thermal (RGBT) observations and event-local task checks on one execution clock. Controlled interventions show why retained heat, spatial transport and internal storage matter for subsequent contact outcomes. From the same state, TRR produces a paired six-task benchmark of 2,224 static--dynamic pairs, that is, 4,448 trajectories with synchronized dual-view observations, states and actions. Visible thermal history raises safe contact-site selection from 75.0\% to 91.7\% on a dedicated learning corpus, and training on dynamic histories raises simulated transfer completion by 50 percentage points under a new heating procedure with shared feedback execution. We demonstrate RGBT observation adapters on MuJoCo and Isaac Sim, report an engineering inventory of ten prepared robot configurations and six demonstrated camera viewpoints, and describe a developer workflow that carries an existing robot scene to exported RGBT records. The benchmark, the workflow and the platform resources described in Section 6 form the first items of a planned public release. Demonstrations and resource updates are available on the project page.

0.17

HeatCache: Thermal-aware Energy-efficient LLM Inference Scheduling for Chassis-level Liquid Cooling in Sustainable Edge Server Rooms

cs.DC cs.PFeess.SY ·2026-09-11 ·Rui Lu, Huanghuang Liang, Kaiqi Guan, Dan Wang
similarity 0.62
Abstract

LLM inference is increasingly deployed at institution-scale edges to meet service requirements. However, multi-GPU inference consumes a large amount of electricity and produces substantial heat. To improve sustainability, operators and regulations often demand raising the ambient setpoint to reduce cooling electricity. This can increase thermal throttling and hardware aging, leading to Service-Level Objective violations. In this paper, we present HeatCache, a thermal-aware, energy-efficient LLM inference scheduler for commercial chassis-level AIO liquid-cooled GPUs at sustainable ambient temperatures. HeatCache treats AIO loops as a temporary heat buffer, measured by heat budget and schedules requests to minimize energy subject to thermal safety and SLO constraints, based on an electrical-informed heat-demand estimation from HeatiTS. We implement HeatCache atop vLLM and show that it reduces computing energy by up to 18.0%, decreases thermal-throttle exposure by 81.7%, and maintains SLO violation rates below 0.9% even up to $48~^{\circ}\mathrm{C}$.

0.11

The World Model Planning Accelerator (WMPA): Hardware-Algorithm Co-Design for Embedded AI in Robotics

cs.AR cs.LGcs.RO ·2026-11-06 ·Prerana Ramkumar, Suhas Suresh Bharadwaj, Fazal Hameed
similarity 0.61
Abstract · 7 pages, 4 figures

Embedded AI is moving from perception to prediction. Robots now use world models$\unicode{x2014}$learned simulators that predict the outcome of candidate actions in a compressed latent space before any is executed. Every predicted step must be computed on board within a tight power and thermal budget, yet the energy these steps fundamentally require, and how far real hardware sits from it, have not been characterized. We derive lower bounds on the arithmetic operations and the CMOS dynamic energy of a latent state transition from information theory and Boolean circuit complexity. Profiling a DreamerV3-style Recurrent State Space Model (RSSM) shows that every rollout operation is memory-bandwidth bound and that a GPU consumes at least $5.9\times10^{10}$ times the CMOS energy floor. Transient 3D thermal simulations show that this inefficiency is also a thermal one, since sustained back-to-back planning heats a millimeter-scale silicon tile to 556 K even behind an ideal copper heat spreader. Guided by this chain from bound to bottleneck, we propose the World Model Planning Accelerator (WMPA), a chip architecture for embedded world model planning that combines near-memory computation, real-time entropy estimation, variable-precision rollout units, and copy-on-write latent scratchpads. With a design target of 40x lower power, the same tile stays near ambient at 306 K in simulation, pointing toward practical planning on thermally constrained robots.

0.20

Job Class Thermal Intent Aware Liquid Cooling Allocation for AI Data Centers

cs.DC cs.PFeess.SY ·2026-09-25 ·Krishna Chaitanya Sunkara
similarity 0.60
Abstract · 6 pages, 5 figures, IEEE conference paper, first submitted to IEEE ICCSP 2026 02/02/2026

GPU-dense AI data centers need to run on liquid cooling as air simply cannot shed the heat at these power densities. Yet the cooling loops themselves are blind to what workloads are about to run; they crank up flow only after a sensor catches a temperature climb, which can take 30 to 50 seconds. We built Job-Class Thermal Intent (JCTI) to close that window. The scheduler already knows a job is coming and what class it belongs to; JCTI feeds that information straight to the cooling controller so it can stage coolant before the heat shows up. We pulled the thermal signatures for each job class out of MLPerf GPU power traces and tuned arrival patterns against Alibaba cluster data. Over 120 paired Monte Carlo trials the numbers come out to 56.4% fewer thermal violations and 60.2% less cumulative overshoot than a straight PI loop. As AI data centers evolving towards gigawatt grid loads with highly fluctuating power swings, thermally-aware scheduling reduces sudden demand and improves load prediction in grid side. Cooling and scheduling have been running as two separate systems for years despite each one knowing something the other needs, JCTI wires them together.

0.22

Energy-Aware Open-Vocabulary Detection Scheduling for Low-Power Robotic Autonomy

cs.RO cs.AI ·2026-11-05 ·Abdul Basit, Muhammad Shafique
published similarity 0.60
Abstract · 6 pages, 8 figures, accepted for publication in ICARCV 2026

Open-vocabulary object detection (OVD) lets robots search for run-time object queries, but fixed-rate inference spends embedded compute on low-value frames during idle motion, map revisits, or stable viewpoints. This paper presents an energy-aware OVD scheduler for low-power mobile robots. The scheduler uses odometry, map change, and detector confidence to switch among low-, mid-, and high-power YOLO-World-S modes on a Jetson Orin Nano. We evaluate the energy-quality trade-off on an AgileX LIMO using 40 real navigation trials: two target objects, five placements per target-policy pair, and four perception policies. Across bottle and cup trials, the scheduler records 8/10 mission success compared with 7/10 for each fixed-rate baseline, while reducing mean Jetson input power (a Jetson-side power-draw metric) by 5.2% relative to an 8 Hz high-rate baseline and lowering achieved OVD call rate by 34.0%. It does not minimize mission-window Jetson input energy because longer missions can erase instantaneous power savings. A separate 60 s stationary microbenchmark isolates the perception workload: the scheduler lowers mean power from 8.045 W to 7.301 W and energy from 484.7 J to 438.1 J relative to the 8 Hz baseline. These results support robot-state-aware OVD scheduling as a promising power-management mechanism with competitive task reliability, while showing that mission-window Jetson input energy must be read together with task progress and runtime.

0.42