HeatCache: Thermal-aware Energy-efficient LLM Inference Scheduling for Chassis-level Liquid Cooling in Sustainable Edge Server Rooms

Rui Lu, Huanghuang Liang, Kaiqi Guan, Dan Wang

cs.DC cs.PFeess.SY ·submitted 2026-09-11 05:14 UTC · v1

Abstract

LLM inference is increasingly deployed at institution-scale edges to meet service requirements. However, multi-GPU inference consumes a large amount of electricity and produces substantial heat. To improve sustainability, operators and regulations often demand raising the ambient setpoint to reduce cooling electricity. This can increase thermal throttling and hardware aging, leading to Service-Level Objective violations. In this paper, we present HeatCache, a thermal-aware, energy-efficient LLM inference scheduler for commercial chassis-level AIO liquid-cooled GPUs at sustainable ambient temperatures. HeatCache treats AIO loops as a temporary heat buffer, measured by heat budget and schedules requests to minimize energy subject to thermal safety and SLO constraints, based on an electrical-informed heat-demand estimation from HeatiTS. We implement HeatCache atop vLLM and show that it reduces computing energy by up to 18.0%, decreases thermal-throttle exposure by 81.7%, and maintains SLO violation rates below 0.9% even up to $48~^{\circ}\mathrm{C}$.

Closest papers

Nearest neighbours by meaning across the whole index.

ETCInfer: An Energy-efficient Thermal-aware Cooling-joint Scheduler for LLM Inference in AI Datacenters

cs.DC cs.PFeess.SY ·2026-09-14 ·Rui Lu, Rui Ge, Huanghuang Liang, Xiaobo Zhou, Dan Wang
similarity 0.84
Abstract · 16 pages

Large language model (LLM) inference in AI datacenters creates a coupled control problem between GPU serving and facility cooling. Raising ambient temperature setpoints can reduce cooling energy and carbon, but also shrinks thermal headroom, induces GPU throttling, and leads to Service-Level-Objective (SLO) violations. In this paper, we study joint cooling--computing control for LLM inference: minimizing per-job GPU-plus-cooling energy while satisfying thermal safety and latency SLO constraints. We present ETCInfer, an energy-efficient, thermal-aware scheduler that selects a pre-job Computer Room Air Conditioner (CRAC) setpoint and adapts per-GPU frequency and micro-batch size during execution. ETCInfer builds compact physics-informed control models by calibrating GPU heat generation, chassis heat dissipation, CRAC power, and prefill/decode latency relations from telemetry. These models estimate hidden thermal states and time-to-throttle, enabling the scheduler to evaluate energy, temperature, and latency before applying an action. We formulate this joint setpoint--frequency--micro-batch control problem as a partially observable Markov decision process and design ETCAdapter, a learning-based controller that minimizes per-job energy under thermal safety and SLO constraints. We implement ETCInfer as a coordination layer over typical inference and cluster management stacks. Evaluation across real-trace simulation and validation experiments shows that ETCInfer reduces total job energy by up to 33.1%, thermal throttle exposure by up to 92.9%, and keeps SLO violation rates below 0.7% even at ambient temperatures up to $48^{\circ}\mathrm{C}$.

0.17

ThermE: Predictive Management of Shared Thermal Headroom for Sustained LLM Inference on Thermally Constrained Edge SoCs

eess.SY ·2026-09-24 ·Rui Lu, Yuheng Wang, Bozheng Liu
similarity 0.77
Abstract · 13 pages, 16 figures

Compact edge system-on-chip (SoC) platforms increasingly run sustained LLM inference under thermal constraints, while their CPU, GPU, and RAM share a cooling path. Prefill and decode therefore consume shared, time-varying thermal headroom, yet vendor governors react only near hardware throttling thresholds without knowledge of request state or upcoming work. A control decision that improves current performance can thus consume headroom too quickly and degrade subsequent service. In this paper, we present ThermE, a runtime system that predicts and jointly manages shared thermal headroom for sustained LLM inference on edge SoCs. Its Fast LLM-to-Heat Compiler maps the model, requests, runtime state, and candidate actions to domain heats without executing LLMs. A partial differential equation (PDE)-constrained Headroom Predictor uses ThermPINN for offline thermal identification and a Reduced Headroom Predictor (RHP) for low-overhead online uncertainty-calibrated headroom forecasts. An Uncertainty-Aware Action Scheduler then selects actions that balance serving quality and future headroom. We implement ThermE atop vLLM and evaluate it across four LLM inference workloads. The results show that ThermE reduces TTFT and TPOT by 40.55% and 12.17%, respectively, relative to vLLM. It achieves a 5.70% SLO violation rate, compared with 12.30% for the strongest baseline, while its predictor obtains a 1.94 $^\circ$C MAE with 11.50 ms overhead.

0.09

Job Class Thermal Intent Aware Liquid Cooling Allocation for AI Data Centers

cs.DC cs.PFeess.SY ·2026-09-25 ·Krishna Chaitanya Sunkara
similarity 0.76
Abstract · 6 pages, 5 figures, IEEE conference paper, first submitted to IEEE ICCSP 2026 02/02/2026

GPU-dense AI data centers need to run on liquid cooling as air simply cannot shed the heat at these power densities. Yet the cooling loops themselves are blind to what workloads are about to run; they crank up flow only after a sensor catches a temperature climb, which can take 30 to 50 seconds. We built Job-Class Thermal Intent (JCTI) to close that window. The scheduler already knows a job is coming and what class it belongs to; JCTI feeds that information straight to the cooling controller so it can stage coolant before the heat shows up. We pulled the thermal signatures for each job class out of MLPerf GPU power traces and tuned arrival patterns against Alibaba cluster data. Over 120 paired Monte Carlo trials the numbers come out to 56.4% fewer thermal violations and 60.2% less cumulative overshoot than a straight PI loop. As AI data centers evolving towards gigawatt grid loads with highly fluctuating power swings, thermally-aware scheduling reduces sudden demand and improves load prediction in grid side. Cooling and scheduling have been running as two separate systems for years despite each one knowing something the other needs, JCTI wires them together.

0.22

AI-driven Thermal-aware Data Center Capacity Planning

cs.LG ·2026-10-01 ·Yixing Li, Mark Fenton, Matthew Kaufeler, Ka Ming Leung, Xin Ai +1 more
published similarity 0.71
Abstract · Presented at DesignCon 2026

The emerging of large language models (LLMs) has posed significant challenges to the thermal management of data center. Intense GPU computation for LLMs results in localized hotspots. Moreover, spiking thermal loads during training and inference bursts make real-time cooling response more difficult to predict and control. Thermal-aware capacity planning of data center requires massive expensive high-fidelity CFD simulations. AI models can perform real-time prediction for unseen designs. However, existing works either have large prediction error, or have over-simplified assumptions for data center operations. This work presents an AI-driven framework that can perform thermal-aware capacity planning for a real-world data center in seconds. The embedded AI model learns from numerous key parameters (rack power, server power, server placement, HVAC settings etc.), and provides temperature prediction within milliseconds. This AI model is tested against high-fidelity CFD simulations, and results show that for unseen data center designs, model can achieve high accuracy with 10000X speedup. Driven by the AI model, the authors design the thermal-aware capacity planning framework. This framework can help data center designers and operators instantaneously optimize both workload distribution and HVAC cooling efficiency.

0.13

Modeling Liquid-Cooled Data Centers in EnergyPlus

eess.SY cs.CEcs.DCcs.LG ·2026-10-23 ·Yun-Dam Ko, Dipashreya A. Sur, Cade Napier, Carlos D. Díaz-Marín, Rishee K. Jain
code/data similarity 0.68
Abstract · 14 pages, 7 figures, 6 tables. Code: https://github.com/Urban-Informatics-Lab/energyplus-liquid-cooling

As AI workloads accelerate data center transition toward high-density racks with direct-to-chip (DTC) liquid cooling, existing simulation tools remain limited in evaluating whole-building and multi-year efficiency. To bridge this gap, we develop a native EnergyPlus object, ElectricEquipment:ITE:LiquidCooled, that models DTC liquid cooling for chilled-water and warm-water architectures as plant-loop components. It couples facility-water loops, rack-side secondary loops, coolant distribution units, and chip-junction temperatures within a single solver. Validation against an independent Modelica implementation across 21 operating conditions, including two full-year runs compared at one-minute resolution, yields loop-temperature RMSE at or below 0.021 K, well within the 0.1 K acceptance threshold. Our case study demonstrates that warm-water liquid cooling reduces annual PUE from 1.43 to 1.25, eliminates on-site water use, and cuts total facility energy by 37.9% relative to an air-cooled baseline. By embedding liquid-cooling logic into EnergyPlus, our work provides whole-building, long-term energy modeling for high-density AI infrastructure within an open-source framework.

0.31

Sustainable Edge Vision via Empirically Calibrated DVFS: Eliminating Thermal Throttling on Passively Cooled Hardware

cs.AR cs.CVcs.LG ·2026-09-04 ·Aayush Marasini, Zhaoxian Zhou
code/data similarity 0.68
Abstract · 7 pages, 5 figures, 8 tables, Code, datasets, and frozen artifacts available at: https://github.com/Aayush-Marasini/sustained-edge-vision

Passive cooling eliminates the energy overhead and mechanical failure modes of fans, making it attractive for edge deployment, yet sustained Deep Neural Network (DNN) inference on passively cooled edge Systems-on-Chip (SoCs) is bottlenecked by thermal throttling. To address this, we propose an empirically calibrated, state-aware Dynamic Voltage and Frequency Scaling (DVFS) scheduler. Unlike heuristic-driven controllers, our methodology utilizes time-domain guards and absolute temperature bounds, with derivative triggers acting as safeguards against sharp thermal spikes. Evaluated on a passively cooled Raspberry Pi 5 running YOLOv8n, our scheduler eliminates all observed thermal throttling events during sustained 30-minute workloads. It outperforms a temperature-only reactive baseline by achieving a 6.8% higher frame rate (Cohen's d = 8.73) while consuming 1.9% less energy per frame. Furthermore, our optimized passive scheduling surpasses an actively cooled reference system in energy efficiency (Joules/frame), though active cooling remains superior for raw throughput. Through isolated ablations, we show that the dwell guard is necessary for run-to-run reproducibility. Finally, exploratory boundary probes indicate that the passive operating envelope closes at ambient temperatures ($\ge 27^\circ$C) where nonlinear leakage defeats DVFS-based control. These results indicate that, within the mapped envelope, correct scheduling can make mechanical cooling unnecessary for sustained edge inference on this platform.

0.37

AI Surge Accelerates the Transition to Liquid Cooling: Rethinking Energy and Water Use in Data Center Cooling

cs.CY ·2026-11-18 ·Yingbo Zhang, Eric Masanet, Shengwei Wang
similarity 0.67
Abstract

The power density of AI workloads is rapidly driving shifts to liquid cooling. This study rethinks and assesses the global impact on energy and water demand of this cooling transformation. Results suggest that liquid cooling can reduce cooling energy use by 25-56% relative to air cooling, offering substantial energy savings for GW-scale AI data centers. Best-practice PUE values could be as low as 1.07-1.08 for today's systems and 1.03-1.04 for emerging designs, and WUE values range from 0.38 to 2.63 L/kWh, depending on temperature conditions. We identify global free-cooling rack inlet temperature thresholds of 33 $^\circ$C for evaporative systems and 49 $^\circ$C for dry systems, demonstrating the practicality of 100% free cooling in many locations. The model finds that minimum PUEs do not necessarily coincide with minimum total energy use, because warmer coolant raises server power. Results quantify the large sustainability potential of liquid cooling and provide actionable targets for data center design and policies.

0.26

PELM: Power Efficient On-Device LLM Inference with Speculative Decoding and Dynamic Voltage Frequency Scaling

cs.LG cs.CLcs.OScs.PF ·2026-09-09 ·Weisi Yang, Stephen Xia
publishedcode/datahighly cited similarity 0.67
Abstract · Accepted to ACM/IEEE SenSys'26

Deploying Large Language Models (LLMs) directly on mobile platforms at the edge is gaining traction due to a myriad of benefits, such as increased privacy, personalization, and reduced latency. However, LLMs have heavy computational requirements, which are difficult for resource-constrained mobile and edge platforms to fulfill. In addition to limited compute resources, mobile and edge systems often have a compact form factor and lack physical mechanisms to dissipate heat generated from high processor usage rates (e.g., fans) to prevent throttling and reduced processing power, which LLMs can easily cause. To mitigate these effects, prior works have proposed various power governing strategies, such as dynamic voltage and frequency scaling (DVFS), for reducing power and heat generation for heavy computational tasks on mobile platforms. Recently, DVFS methods tailored for mobile LLMs have also been proposed. However, these methods mostly focus on optimizing hardware parameters and processor frequencies, and they fall short under some thermally constrained scenarios. Drawing from recent advances in machine learning, we identify and take advantage of the key insight that not all tokens require full-depth inference to maintain high-quality generation. Motivated by this, we present PELM, a solution that augments traditional DVFS processor frequency tuning with two additional workload-specific knobs: 1) speculative decoding and 2) variable verification depth to expand the optimization space to multiple dimensions for more power efficient on-device LLM inference. In extensive evaluations across hardware platforms and datasets, PELM demonstrates superior performance compared to state-of-the-art power governing methods, with up to 23.1% speedup and 52.4% reduction in energy consumption, while maintaining comparable task performance. The source code is available at https://github.com/imec-nu/PELM.

0.64