CS Paper Radar

A Topology-Aware Neural Network for Fault Location With Missing Measurements

Fan Jiang, Linhan Fang, Xingpeng Li, Kaushik Rajashekara

eess.SY ·submitted 2026-10-27 01:32 UTC · v1

Abstract

This paper proposes a topology-aware neural network-based fault locator (TANFL) for radial distribution feeders, which uses voltage and current phasors obtained after the decay of fault induced transients, as well as feeder connection relationships and line parameters, as inputs. The shared bus encoder, bus readout module, and gated line readout module work together to identify the faulty bus or line and estimate the continuous fault location on the selected line. During training, explicit missing data indicators and random bus data block masking are introduced, enabling a single trained model to handle both complete measurement sets and scenarios where any permitted bus measurement device fails. On the IEEE 15 bus feeder, this paper compares TANFL with a conventional multilayer perceptron (MLP) and the formula-based localization method under identical data, measurement availability scenarios, and evaluation metrics. On the test partition, TANFL outperforms the conventional MLP; with complete measurements, its line fault location performance is slightly lower than that of the formula-based method, but in the average results for scenarios with one missing bus measurement block, its accuracy is the highest among the three methods at a 5% tolerance.

Closest papers

Nearest neighbours by meaning across the whole index.

Understanding the limits of snapshot-based fault diagnosis in distribution networks

cs.AI ·2026-11-13 ·Ba Tu Phung, Huy Hoang Le, Kim-Anh Nguyen
similarity 0.61
Abstract

Inverter-based resources weaken fault currents in distribution networks, and snapshot-based diagnosis, which classifies a fault from voltage phasors at a few buses at one instant, offers a cheap first-stage screen. Its published accuracies, however, rest on different noise assumptions and do not show whether the error comes from the classifier, the features, the measurement error, or the fault resistance. This paper separates these sources on three IEEE test feeders and a public data set with distributed generation, using four feature sets, thirteen classifiers, and measurement error defined by total vector error classes. The classifier is not the limiting factor, because the full phasor snapshot classifies every fault correctly without noise, and the remaining error comes from measurement error on high-impedance faults. Three voltage sensors classify 90-96% of faults at the 1% accuracy class and 96-99% with distribution micro phasor measurement units (micro-PMUs). A discriminability-margin placement selects them from simulations alone in under one second and matches the best of twelve placement methods. The results show when snapshot-based diagnosis can be trusted.

0.31

The Price of a Cycle: A Phasor -vs- Sampled-Value Comparison for Streaming Fault Classification on the IEEE 9-Bus System

eess.SY ·2026-10-03 ·Emad Abukhousa, Khaled Muhmmed Nor Muhmmed, Abdulaziz Qwbaiban, Saman Zonouz, A. P. Sakis Meliopoulos
benchmark similarity 0.59
Abstract

Transmission-line fault classification is a time-critical protection function, and recent machine-learning methods classify fault type directly from voltage and current measurements. The input to such a classifier can be supplied as sampled-value windows of raw measurements, which preserve sub-cycle structure, or as phasor-domain sequence components, which are physically interpretable but require a causal one-cycle observation window before a phasor estimate is available. This paper measures the cost of that observation window, the price of a cycle, through a controlled comparison of the two representations for streaming fault-family classification on the standard synchronous WSCC/IEEE 9-bus system. The comparison holds the simulated system, the measured channels, the eleven-class event-family taxonomy, the training procedure, and the streaming decision layer constant, and uses six configurations: 40- and 80-sample sampled-value inputs and one-cycle phasor inputs, each evaluated with a multilayer perceptron (MLP) and a one-dimensional convolutional neural network (CNN). All six configurations classify every event successfully, yet the sampled-value representation reaches the correct class earlier in every model pair. The 40-sample sampled-value MLP attains the strongest result, with 99.34% fault-window accuracy, 99.79% normal accuracy, a 0.21% false-fault rate, a 0.65% false-normal rate, and a 2.81 ms mean first-correct delay, and it Pareto-dominates the other five configurations. A matched-window comparison at eighty samples confirms that the timing advantage follows from the representation rather than from the window length. On this clean synchronous benchmark, the one-cycle phasor representation does not return an accuracy or stability benefit sufficient to offset its delay.

0.31

Learning-Based Power Flow Estimation with Sparse PMU Deployment in Power Systems

eess.SY ·2026-10-09 ·Van-Hai Bui, Quang Manh Hoang, Akhtar Hussain, Wencong Su
similarity 0.59
Abstract · 14

Accurate monitoring of power flow is fundamental to the secure and reliable operation of modern power systems. Existing data-driven power flow estimation methods typically assume that synchronized measurements are available at every bus, requiring extensive deployment of phasor measurement units (PMUs). Such dense sensing infrastructures substantially increase installation, communication, and maintenance costs. This paper proposes a learning-based framework that minimizes the number of installed PMUs while maintaining high-accuracy systemwide power flow estimation. Instead of relying on measurements from all buses, the proposed method identifies an informative subset of buses whose synchronized measurements are sufficient to accurately reconstruct branch power flow across the network. To this end, a neural network is developed to learn the nonlinear relationship between PMU measurements and system-wide power flows, and multiple PMU deployment scenarios are evaluated to quantify the trade-off between measurement availability and estimation accuracy. The results enable utilities to identify cost-effective PMU placement strategies that balance deployment cost and prediction performance. Case studies on the IEEE 30-bus test system demonstrate that the proposed framework significantly reduces the number of required PMUs while maintaining accurate power flow estimation.

0.18

Adaptive State Estimation Under Topological Uncertainty in Unobservable Primary Distribution Systems Using Strategically Placed Sensors

eess.SY ·2026-09-23 ·Farah Elsherif, Behrouz Azimian, Anamitra Pal
published similarity 0.55
Abstract · 6 pages, 6 figures, 4 tables. Accepted for presentation at the 2026 North American Power Symposium (NAPS)

The rapid integration of distributed energy resources is fundamentally altering power flow patterns in primary distribution networks and intensifying operational uncertainty. These problems are further compounded by lack of real-time situational awareness and frequent topology changes. To address these problems, this paper proposes an integrated deep learning framework for simultaneous topology identification (TI) and distribution system state estimation (DSSE) in real-time unobservable primary distribution networks instrumented by a minimal set of synchronized measurement devices (SMDs). A correlation-driven SMD placement algorithm is introduced first that jointly satisfies TI accuracy and DSSE performance requirements by exploiting temporal and spatial correlations in nodal voltage measurements. A dual deep neural network (DNN)-based DSSE model is developed next to estimate three-phase voltage magnitudes and angles across diverse operating conditions. To extend the framework beyond the base topology, fine-tuning-based transfer learning is employed to adapt the DSSE model to reconfigured topologies using limited retraining data. The framework is validated under both Gaussian and non-Gaussian measurement noise and benchmarked against a conventional estimation approach and a single DNN model.

0.35

A Systematic Evaluation of Machine Learning Methods for Fault Detection and Line Identification in Electrical Power Grids

cs.LG eess.SP ·2026-09-15 ·Julian Oelhaf, Georg Kordowich, Paula Andrea Pérez-Toro, Tomás Arias-Vergara, Andreas Maier +2 more
publishedhighly cited similarity 0.53
Abstract · Accepted at ICASSP 2025. 5 pages, 4 figures. Published version: DOI 10.1109/ICASSP49660.2025.10890544

The integration of renewable energy sources into the electrical grid introduces complex challenges in fault detection and coordination of grid recovery mechanisms. Traditional relay protection systems, which operate based on static rules and predefined thresholds, are inadequate for addressing these challenges, particularly in detecting and isolating faults such as short circuits. Consequently, the conventional methodologies applied to electrical network protection frequently fail to achieve optimal performance in fault detection, especially in terms of adherence to safety standards and the selective limitation of damage. Recent research indicates that machine learning (ML)-based approaches can effectively tackle these issues; however, variations in grid configurations and analysis windows have impeded consistent comparative assessments. In this study, we assess the efficacy of various ML models in detecting electrical faults and pinpointing defective transmission lines within a 10 ms measurement interval - a critical time-frame for real-time operational viability, for the first time. The most effective model attained an F1 score of 0.991 +/- 0.018 and demonstrated a processing time of 0.342ms +/- 0.509ms.

0.52

Machine Learning-Based State Estimation for an Actual Transmission System Using Field PMU Data

eess.SY ·2026-09-22 ·Shiva Moshtagh, Nihar Thakkar, Anamitra Pal, Evangelos Farantatos
published similarity 0.52
Abstract · Accepted for presentation at the 60th Hawaii International Conference on System Sciences (HICSS-60), 2027

Time-synchronized state estimation (SE) plays a critical role in ensuring real-time situational awareness in modern power systems. However, achieving full system observability using phasor measurement units (PMUs) is often impractical due to cost and deployment constraints. Moreover, SE operation at PMU timescales imposes stringent requirements on latency, robustness, and reliability that are difficult to satisfy using conventional iterative hybrid SE techniques under incomplete observability by PMUs. This paper evaluates the feasibility of deploying deep neural networks for PMU-timescale, time-synchronized SE in real-world PMU-unobservable transmission systems using actual data from a US power utility. Key contributions include a systematic assessment of estimation accuracy, scalability, and computational performance under realistic operating conditions.

0.34

One-Cycle Fault Classification and Faulted-Line Identification on the PROTECT-90 Dataset: An Initial Application Benchmark

eess.SY cs.LG ·2026-10-02 ·Emad Abukhousa, Abdulaziz Qwbaiban, Saman Zonouz, A. P. Sakis Meliopoulos
benchmarkcode/data similarity 0.52
Abstract

Open electromagnetic-transient datasets are beginning to make reproducible learning-based protection studies possible, but the practical use of these datasets still requires application-level benchmarks that define timing, sensing, and validation assumptions. This paper presents an initial application benchmark on the recently released PROTECT-90 dataset for two protection-oriented tasks: fault-type classification and discrete faulted-line identification. A compact one-dimensional convolutional neural network (CNN) is evaluated using post-inception windows of 0.25, 0.5, 1, and 2 cycles under strict episode-wise splitting. A non-convolutional multilayer perceptron (MLP) is also trained as an architecture-control baseline. The results show that both tasks are nearly saturated under full observability, with one-cycle test accuracies of 99.84% for fault type and 100.00% for line identification. The main performance variation appears under reduced observability: current-only inputs preserve line identification accuracy at 100.00%, whereas voltage-only inputs reduce line identification accuracy to 53.09% with the CNN and 50.57% with the MLP. This indicates that the limiting factor is measurement information rather than neural architecture. Additional stratified checks show stable performance across topology states and fault-resistance bins, while CPU inference contributes only 0.528 ms to the one-cycle total decision time of 20.53 ms.

0.29

GCN-Based Model for Fault Classification in Distribution Networks under Harmonic Distortion

eess.SP ·2026-09-23 ·Fathima Razeeya Mohamed Razick, Syed Muhammad Ahsan, Petr Musilek
published similarity 0.51
Abstract · Accepted and presented at the IEEE Power and Energy Society General Meeting 2026, Montreal, Canada, July 19-23, 2026

The increasing integration of distributed energy resources introduces new challenges for accurate fault detection and classification in distribution networks. This paper presents a topology-aware graph convolutional network-based model for fault classification under inverter-induced harmonic distortion. The model uses pre-fault and post-fault voltage and current phasors, including harmonic components, mapped to the IEEE 34-bus system topology. The simulation data generated in OpenDSS encompass varying levels of penetration of solar photovoltaics (30%, 50%, 70%) and current total harmonic distortion (0%, 1%, 3%, 5%) across multiple fault types: single line-to-ground, line-to-line, double line-to-ground, and three-phase-to-ground. A differential evolution algorithm is employed to optimize the hyperparameters of the network, resulting in a three-layer model that achieves an F1-score of 0.98. Stress testing across scenarios confirms high robustness and minimal class confusion. The results demonstrate that a graph convolutional network-based model can effectively classify distribution faults under varying photovoltaic penetration levels and harmonically distorted conditions. Comparative analyses with convolutional neural network, long short-term memory, and multi-layer perceptron architectures demonstrate that the proposed model delivers superior classification performance, particularly under the most stressed condition with 70% photovoltaic penetration and 5% harmonic distortion.

0.48