CS Paper Radar

Thermal-Mass Coupled Modeling and Optimal Scheduling of Aluminum Smelting Loads for Safe Demand Response Participation

Yan Shen, Ruike Lyu, Shuoqi Wang, Jing Dai, Hongye Guo, Chongqing Kang

eess.SY ·submitted 2026-10-27 03:04 UTC · v1
top venue

Abstract

Aluminum smelting loads (ASLs) offer substantial flexibility potential, yet their actual participation in demand response remains conservative owing to the risk of operational failures. Power adjustments disturb the electrolyte temperature and superheat, which may lead to electrolyte freeze-out or yield loss. Existing ASL demand response methods often rely on oversimplified dynamic models of the electrolytic cell's thermal behavior, such as linear models and the Equivalent Thermal Parameter (ETP) model, which may either violate temperature constraints or underestimate the available flexibility. To address this limitation, this paper proposes a Thermal-Mass Coupled (TMC) dynamic model. The model captures the essential physical mechanisms of electrolytic cells, including alumina feed dynamics, ledge phase-change dynamics, and state-dependent current efficiency. The resulting nonlinear relations are reformulated into a tractable mixed-integer linear programming (MILP) model using Taylor approximations and McCormick-envelope reformulations. In the illustrative PBDR and IBDR case studies, the nonlinear reference-model assessment shows that the TMC model achieves net economic improvements 122.4% and 325.1% higher, respectively, than the ETP model. The proposed framework can therefore support deeper demand response participation by aluminum smelters while explicitly assessing adherence to operational safety constraints.

Comment
Accepted for publication in IEEE Transactions on Smart Grid. DOI: 10.1109/TSG.2026.3736640. This is the author-accepted manuscript
DOI
10.1109/TSG.2026.3736640

Closest papers

Nearest neighbours by meaning across the whole index.

Integrated Heat and Power System Scheduling with Continuous-Time Thermal Dynamics via Bernstein-Galerkin Optimization

eess.SY ·2026-08-18 ·Jie Deng, Zhigang Li, J. H. Zheng, Ye Guo
top venue similarity 0.58
Abstract

Coordinated scheduling of district heating networks (DHNs) and electric power systems can improve operational flexibility and reduce costs by exploiting thermal inertia. Most existing formulations rely on simplified discrete-time DHN models, which may inadequately represent continuous spatiotemporal thermal dynamics and can lead to biased flexibility estimation and suboptimal schedules. In this paper, an integrated heat and power system scheduling framework that explicitly incorporates the continuous-time thermal dynamics of DHNs is proposed. A Bernstein-Galerkin transform method is developed to convert the underlying partial-differential thermal-dynamics constraints into a finite set of algebraic constraints, enabling tractable optimization while retaining dynamic fidelity. The resulting model transforms the original infinite-dimensional variational problem into a finite-dimensional coefficient optimization that can be solved using optimization solvers. Compared with conventional discretization approaches, the proposed method provides a more accurate representation of thermal dynamics and yields schedules with improved economic performance and reliability.

0.57

Koopman-Based Model Predictive Control for Simultaneous State of Charge and Temperature Balancing of Lithium-Ion Cells

eess.SY ·2026-09-07 ·Jihoon Moon
similarity 0.55
Abstract

Cell-to-cell electrical and thermal variations produce nonuniform state of charge (SoC) and temperature distributions in lithium-ion battery packs. This paper proposes a Koopman-operator-based framework for simultaneous SoC and temperature balancing of series-connected cells. Cell-specific Koopman predictors identified using extended dynamic mode decomposition are assembled into neighboring-cell error dynamics that retain heterogeneity and thermal-disturbance effects. A Tikhonov-regularized feedforward controller provides numerically robust compensation without excessive current amplification, while constrained Koopman-based model predictive control (KMPC) regulates the residual errors through a convex quadratic program. Three-cell simulations validate the controller under two consecutive Urban Dynamometer Driving Schedule cycles. KMPC achieves balancing performance comparable to nonlinear model predictive control (NMPC). Relative to the uncontrolled case, KMPC reduces the RMSEs of the neighboring-cell SoC and core temperature differences by 66-81% and 57-76%, respectively, while reducing the computation time per optimization from 0.0259s for NMPC to 0.0028s for KMPC.

0.31

Optimal Coordination of Heat Pump Demand Flexibility and Battery Energy Storage Considering the Operation of Distribution Networks

eess.SY ·2026-10-06 ·Gustavo L. Aschidamini, Guilherme S. Castiglio, Mariana Resener
similarity 0.54
Abstract

Electrifying space heating with heat pumps (HP) and backup electric-resistance heaters (ERH) is incentivized to support decarbonization but increases voltage and thermal issues in distribution networks. Direct load control (DLC) of smart thermostats (ST) provide grid support, yet, to the best of our knowledge, existing methods do not co-optimize this flexibility with grid-scale battery energy storage systems (BESS) and voltage-regulation devices, and do not use ERH for preheating, limiting peak demand reduction and undervoltage mitigation. We propose a mixed-integer linear programming (MILP)-based model predictive control (MPC) framework that coordinates ST setpoints for preheating and setback, grid-scale BESS, on-load tap changers, switched capacitor banks, and step voltage regulators. The framework is evaluated on 23-node and 733-node distribution networks, including a real-data-based feeder, across multiple realized days. On the 23-node feeder with 50% HP penetration and 50% DLC participation, the proposed framework reduces the feeder peak by 23.1%, and by 27.1% with the co-optimized BESS. Rolling-horizon setpoint optimization contributes 6.5 percentage points beyond a day-ahead ST schedule (16.6%), and dispatching the ERH for preheating adds 2.7 percentage points beyond backup-only operation (20.4%). On the 733-node feeder, where thermal congestion is the binding constraint, the framework reduces overloaded branches by 94% and overloaded transformers by 47%. These results demonstrate the potential of coordinated demand flexibility and voltage regulation to accommodate heating electrification.

0.12

Differentiable Hybrid-Action Neural Feedback Control for District Heating Networks

eess.SY ·2026-10-01 ·Nicolas Kirsch, Corrado Sgadari, Alessio La Bella, Giancarlo Ferrari-Trecate
similarity 0.54
Abstract

Many cyber-physical systems require control policies that combine continuous setpoints with discrete operational de- cisions, such as equipment switching, mode selection, or resource scheduling. Discrete actions are not differentiable, which ob- structs gradient-based policy training, while conventional mixed- integer formulations remain costly to solve online. This paper proposes a hybrid-action neural controller (HANC) in which a continuous branch, a categorical branch and a differentiable assembly layer jointly generate commands that satisfy complex actuator constraints by construction. Categorical decisions are handled using a straight-through Gumbel estimator, enabling the policy to be trained by backpropagation through time over full closed-loop rollouts. The proposed framework is deployed on a district heating network (DHN) featuring multiple heat generation units and stratified thermal energy storage. Its performance is evaluated on a simulation of a real DHN located at RSE SpA in Italy. The resulting policy jointly learns switching decisions and continu- ous operating setpoints. Under dynamic electricity pricing, the learned controller reduces operating cost by 30% compared to a rule-based industrial baseline. We also show that, compared with a deterministic straight-through relaxation, injecting noise during training achieves similar cost while reducing hard switching by an order of magnitude, and attribute this difference to the wider decision margins of the resulting policy.

0.24

Industrial Load Modeling and Optimization for Market-Based Interaction with Power Systems

eess.SY ·2026-08-15 ·Ruike Lyu
similarity 0.53
Abstract · PhD thesis, Tsinghua University, June 2026, 176 pages

The transition toward a renewable-dominated power system increases the flexibility needed to balance net-load variations. Industrial loads account for over 40% of the world's electricity consumption and can shift large amounts of demand through automated production scheduling. However, making industrial processes a dependable flexibility resource for power systems remains challenging because industrial process constraints are non-convex, equipment parameters are often private, and device-level models of thousands of facilities are too detailed for aggregator and power-system optimization. This dissertation builds computationally efficient methods for modeling and optimizing industrial flexibility for power-system interaction. Specifically, this dissertation uses smart meters as the external measurement interface and maps industrial process constraints into a concise flexibility space for power-system operation. The resulting chain of mechanism modeling, parameter identification, constraint dimension reduction, and optimal decision-making makes industrial-load participation computationally tractable while retaining precise process models for final execution.

0.10

Assessing Modeling Fidelity for Long-Term Battery Energy Storage Planning: Operation, Degradation, and Temporal Representation

eess.SY ·2026-09-30 ·Hassan Zahid Butt, Xingpeng Li
similarity 0.52
Abstract

Long-term battery energy storage system (BESS) planning often relies on simplified degradation, operational, and temporal representations to maintain computational tractability, yet their effects on lifecycle conclusions are not well understood. This paper assesses the modeling fidelity needed for long-term lifecycle evaluation of BESS designs used in planning studies. A 20-year grid-connected microgrid is sized using a degradation-naive planning model, after which the installed portfolio is fixed and evaluated through sequential lifecycle validation. The reference representation combines nonlinear calendar and cycle aging, C-rate-dependent efficiencies, state-of-health-dependent performance, self-discharge, battery replacement, and full 8,760-h chronology. Battery-model hierarchies, targeted ablations, linear degradation surrogates, health-update intervals, temporal reductions, and combined simplifications are compared using lifecycle cost, replacement timing, state of health, and energy adequacy. The reference case produces replacements in years 9 and 18, a $111.25 million lifecycle net present cost, and 24.01 MWh of cumulative energy not served. Omitting calendar aging eliminates both replacements and understates lifecycle cost by 35.1%, whereas a separately calibrated linear surrogate model reproduces both replacement years and limits the cost deviation to 0.2%, although energy not served remains 31.8% below the reference. A peak-informed calibrated 12-day representation preserves replacement timing but reports zero energy not served, while replacing the preserved peak day with the maximum daily-energy-deficit day substantially overstates energy not served because representative-day closure alters the battery state surrounding the critical event. The results show that modeling fidelity is metric-dependent and should be selected according to the lifecycle outcome to be preserved.

0.10

Building Seasonal Highways for Residential Energy Hubs: Sizing, planning and operating thermal energy storage

eess.SY math.OC ·2026-10-01 ·Dario Slaifstein, Mohammad Khosravi, Gautham Ram Chandra Mouli, Laura Ramirez-Elizondo, Pavol Bauer
similarity 0.52
Abstract

The operation of residential energy hubs with multiple energy carriers (electricity, heat, mobility) poses a significant challenge due to the energy storage differences in time-constants, round-trip efficiencies and self-discharge rates. Usually, thermal storage exhibits flexibility in yearly planning optimizations or long-term scenarios. However, as optimization horizons shrink (1-48hs) so does their supplied value due to the lower round-trip efficiencies. To avoid this early depletion during operation this paper proposes a data-driven highway to steer the short-term daily control towards long-term optimality. The proposed methodology also presents how to optimally size the thermal storage and avoid yearly simulations and how all of this is related to nonlinearities in the daily operation. The presented framework links seasonal and daily optimizations through dynamic terminal sets and value functions. The seasonally-aware nonlinear economic model predictive controller achieves the most balanced performance, with the second best mean grid cost of all MPCs at -\texteuro 209. It also achieves better battery degradation control than its linear counterparts (between 26-34%) and the best thermal comfort of the nonlinear benchmarks. Nevertheless, the data-driven seasonal highway restrains the ability to control battery degradation and slightly increases computational time.

0.14

Continuous-Time Aggregation of Massive Flexible HVAC Loads Considering Uncertainty for Reserve Provision in Power System Dispatch

eess.SY ·2026-09-02 ·Jingguan Liu, Xiaomeng Ai, Jiakun Fang, Shichang Cui, Shengshi Wang +2 more
top venuehot directionhighly cited similarity 0.52
Abstract · Published in: IEEE Transactions on Smart Grid (vol. 15, no. 5, pp. 4835-4849, 2024)

Heating, ventilation, and air conditioning (HVAC) loads, with their rapid response capabilities, can provide considerable intra-hour flexibility on the demand side for reserve provision in order to follow the fast variations of renewables. However, scheduling massive HVACs is challenging due to computation complexity and the uncertainty of outdoor temperature. In this paper, we first introduce a novel continuous-time (CT) aggregation model to reveal the potential intra-hour flexibility of HVACs. For accurate aggregation, a new affine transformation is designed to handle the heterogeneity in high-dimensional feasible region. Further, for reliable aggregation in practical environment, the outdoor temperature uncertainty is constructed by distributionally robust chance constrains and integrated into the aggregation model. Secondly, for the tractable calculation of the proposed CT aggregation model, a cascade of tailored reformulation techniques is proposed, including the Bernstein polynomial spline, polytope projection, and linearization transformation. Thirdly, a customized hierarchical dispatch framework is proposed via incorporating the proposed CT aggregation model into reserve provision in power system dispatch, so as to efficiently schedule massive HVACs to cope with the renewable uncertainty. Case studies verify the effectiveness and scalability of the proposed CT aggregation model in aggregation accuracy, intra-hour flexibility utilization, and uncertainty handling.

0.67