MCP-Net: Real-Time Coronary Perception Network and Topological Analysis for Robotic Guidewire Navigation

Sahar Nasirihaghighi, Tianyuan Wang, Kenan Niu, Stefano Stramigioli

cs.CV cs.RO ·submitted 2026-10-27 12:25 UTC · v1

Abstract

Coronary guidewire navigation during percutaneous coronary intervention requires continuous interpretation of vessel anatomy, guidewire position, and target stenosis under two-dimensional X-ray fluoroscopy. While existing approaches commonly address vessel segmentation or device localization as separate tasks, a robotic system requires a more structured perception of the coronary scene to support downstream navigation. In this work, we present a simulation-driven framework centered on a Multi-Task Coronary Perception Network (MCP-Net) for robotic guidewire navigation, integrating coronary vessel segmentation, vascular topology extraction, and roadmap generation. Starting from three-dimensional coronary CT angiography, we generate simulated fluoroscopy images containing vascular structures, simulated guidewires, stenotic lesions with varying severity, and diverse vascular geometries, together with simulation-derived ground truth. MCP-Net jointly performs coronary vessel segmentation, guidewire-tip localization, and stenosis localization from a single fluoroscopic frame. These predictions are subsequently converted into a structured vascular graph containing centerlines, bifurcations, endpoints, branch directions, and branch angles. By associating the predicted stenosis with this graph, the framework generates a roadmap from the automatically selected graph root toward the target lesion. The results demonstrate that the proposed framework can jointly recover coronary perception targets and transform them into an interpretable vascular representation suitable for downstream robotic navigation.

Closest papers

Nearest neighbours by meaning across the whole index.

PPCAR-Net: Projection-Refined Parametric 3D Coronary Artery Reconstruction from Sparse X-ray Angiographic Views

cs.CV ·2026-10-07 ·Yu Ren, Hwee Kuan Lee, Tat-Jen Cham, Jonathan Yap, Khung Keong Yeo
code/data similarity 0.66
Abstract · 22 pages, 5 figures, 10 tables, including references and appendix. Code and pretrained models: https://github.com/G2304138H/PPCAR-Net . Proj…

Sparse-view 3D coronary reconstruction commonly relies on cross-view correspondence and triangulation, which are vulnerable to vessel overlap and foreshortening, or on volumetric prediction followed by vascular-graph extraction, which does not directly provide centrelines and radii. We introduce PPCAR-Net, a projection-refined parametric coronary artery reconstruction network that directly predicts a branch-structured centreline-and-radius representation without explicit point matching, triangulation, or an intermediate volume. Given a variable number of segmented views, a coarse predictor combines frozen VGGT features with learned branch queries to estimate branch presence, B-spline centreline trajectories, and dense radius profiles. Projection-guided geometry and radius refiners then sample local evidence from the input views and apply residual corrections learned with 3D supervision. We evaluate representation fidelity and sparse-view reconstruction quantitatively and qualitatively. On simulated angiographic masks generated from CT-derived coronary anatomy, PPCAR-Net produces better connected artery reconstructions and achieves strong centreline accuracy, particularly for RCA, while maintaining competitive volumetric overlap. Coarse-to-fine inference takes 121 ms, enabling real-time reconstruction.

0.29

Sub-Voxel Displacement and Ipsilateral Territory Decoupling for 3D Bilateral Coronary Artery Tree Reconstruction in Cardiac CT Angiography

cs.CV q-bio.TO ·2026-10-05 ·Zeyu Jia, Xin Ming
similarity 0.65
Abstract · 18 pages, 4 figures, 7 tables; includes combined Supplementary Material (Algorithms A1-A5 and Tables S1-S5)

Reconstructing topologically complete, sub-voxel-accurate 3D bilateral coronary artery trees from cardiac CT angiography (CCTA) requires simultaneously recovering continuous centerline trajectories and separating dense left/right coronary territories without cross-ostial collisions. We present a five-stage tubular drift and ipsilateral territory decoupling framework (M1-M5). Stage M1 pairs a 398,843-parameter multi-scale 3D pyramid encoder with a four-head tubular field network predicting vesselness probability, signed tubular boundary distance, unit tangent vectors, and continuous 3D centripetal displacement vectors. Stage M2 introduces recall-preserving multi-task optimization with 7-group AdamW parameter decoupling, L2-SP backbone regularization, and per-step anchor shrinkage. Stage M3 calibrates cylindrical Valsalva-sinotubular-junction wall coordinates and native-resolution orifice contact expectations for robust left and right ostial rooting. Stage M4 constructs a scalar-potential-weighted minimum-cost arborescence followed by normal-plane cross-sectional pullback and centripetal trajectory pruning. Stage M5 enforces coverage-guarded ipsilateral-field-coupled bilateral collision reduction and subtree handover. Across a 14-case held-out development cohort (Dev-14, 17-arm forward incremental build and 9-arm leave-one-out ablation) and an independent 50-case out-of-sample evaluation cohort (OOS-50) benchmarked against seven external architectures (nnU-Net, 3D UX-Net, Swin-UNETR, MedNeXt, CS2-Net, clDice-UNet, and Point-UNet), M1-M5 reduces bilateral chamfer distance on Dev-14 from 3.4381 mm to 2.2759 mm and achieves 2.7671 mm on OOS-50 with 7.11% bilateral collision rate and 79.7% distal branch completeness.

0.29

BSC-Net: A Small-Branch-Sensitive Structural Continuity Network for Coronary Vessel Segmentation and Quantitative Angiographic Analysis

cs.CV ·2026-09-14 ·Wanxian Li, Jiaqian Qin, Qingyi Xian, Yazhi Li, Song Chen +2 more
similarity 0.63
Abstract · 29 pages, 9 figures, including Supplementary Material

Vessel segmentation in X-ray coronary angiography (XCA) is a fundamental step for quantitative coronary analysis and subsequent assessment of coronary artery disease. However, accurate vessel segmentation remains challenging because of imaging noise, complex bifurcations, and the overlap of vessels and background structures, which can lead to disrupted vascular connectivity and missed small branches. In this work, we propose BSC-Net, a ResNet-U-Net-based framework tailored to improve small-vessel representation and repair vascular structural continuity. BSC-Net enhances small-vessel representation through targeted sampling and improves vascular structural continuity by integrating long-range contextual modeling and Edge-Informed Loss (EIL). BSC-Net was validated on two public XCA datasets, demonstrating state-of-the-art (SOTA) performance in coronary vessel segmentation with Dice and IoU scores of 77.8%/90.6% and 64.5%/83.0%, respectively. Furthermore, based on the obtained vessel segmentation, we performed automated quantitative coronary analysis and derived clinically relevant morphological and hemodynamic parameters, including stenosis ratio, time-to-peak, and relative propagation velocity. These results demonstrate that BSC-Net produces accurate vessel segmentation results with preserved vascular continuity for quantitative coronary assessment, enabling reliable downstream analysis and clinical evaluation of coronary artery disease.

0.21

Beyond Volume Overlap: Surface Matching for Topology-Aware Coronary Artery Segmentation

cs.CV ·2026-09-22 ·Rafael Velasquez, Esther Puyol-Antón, Pablo Arbeláez
published similarity 0.62
Abstract · 12 Pages, 2 figures, Statistical Atlases and Computational Modeling of the Heart (STACOM) workshop of MICCAI 2026

Accurate coronary artery segmentation on coronary computed tomography angiography (CCTA) is essential for diagnosing coronary artery disease. Deep networks are conventionally trained and evaluated with the Dice coefficient, but volume-overlap metrics are poorly suited to thin, tubular anatomy: since most voxels belong to a few thickproximal segments, a missing distal branch barely affects Dice despite severely disrupting the connectivity required for clinical use. We introduce a surface metric that matches predicted and reference surface points via bipartite assignment under a localized, vessel-radius tolerance, reporting precision, recall, and F1 with decoupled false positives (spurious branches) and false negatives (missed branches) a distinction the symmetric Dice cannot make. With it we show that a strong Dice-trained baseline omits far more vessel surface than it hallucinates, an asymmetry its high Dice hides. Building on this, we propose a differentiable surface loss that simultaneously suppresses spurious mass and recovers absent structure, validated by fine-tuning three backbones (nnU-Net, SwinUNETR, NexToU) on two public benchmarks (Image-CAS, ASOCA). Against a matched-epoch control, it significantly improves surface F1 by recovering missed distal vessels at comparable Dice. Our findings argue for measuring and optimizing the vessel surface, not the volume it overlaps. Code

0.19

Multi-Stage NeRF for Efficient 3D Coronary Artery Reconstruction from Two Narrow-Angle Angiographic Projections

cs.CG cs.CV ·2026-09-14 ·Deyu Meng, Mojtaba Lashgari, Yiying Wang, Abhirup Banerjee
top venue similarity 0.61
Abstract · 11 pages, 2 figures

X-ray coronary angiography is the clinical gold standard for coronary artery disease during real-time cardiac interventions, but provides only 2D projections of inherently 3D vessels. Existing learning-based 2D-to-3D reconstruction methods typically require wide angular coverage or multiple views, assumptions that are rarely satisfied in routine practice where only two projections with narrow angular separation are available. To address these challenges, we propose NeCA++, a multi-stage self-supervised neural radiance field (NeRF) framework tailored to clinically realistic acquisition constraints. The framework decomposes reconstruction into two stages that progressively refine spatial support and representation capacity. In the first stage, a coarse 3D representation of the vasculature is reconstructed, restricting the subsequent optimisation to regions with a higher likelihood of vessel presence, termed an active region. Afterward reconstruction is restricted to this region while higher-resolution representations are progressively activated to recover fine vascular details. This multi-stage strategy focuses learning on anatomically plausible regions, mitigates gradient dilution under extreme sparsity, and stabilises global topology before recovering fine vascular branches. Furthermore, two vessel-specific regularisations are introduced: a ray-aligned constraint to reduce projection-induced ambiguity, and a bimodal density penalty to enable early vessel-background separation. Extensive experiments across three datasets (ImageCAS, ASOCA, and Synthetic RCA) and four angular configurations demonstrate consistent superiority over state-of-the-art baselines, particularly under clinically realistic narrow-angle settings, while achieving reconstruction within 58 seconds per case.

0.29

A 2D Image Feedback-Based Autonomous Endovascular Navigation Method: A Perception and Control Framework

cs.RO ·2026-10-15 ·Sheng Cao, Shuxiang Guo, Yonggan Yan, Jian Guo, Chunying Li +6 more
similarity 0.61
Abstract

In endovascular interventions, physicians rely on planar DSA and X-ray fluoroscopy to interpret vessel anatomy and device motion, yet converting these images into feedback for autonomous navigation remains difficult. A perception and control method is formulated for two-dimensional image feedback. Vessel masks are converted into a labeled centerline graph, and device-tip estimates are projected onto a planned path to obtain progress, deviation, and direction. A rule-based controller uses these quantities for delivery, branch selection, probing, rollback, and recovery. The method was evaluated on a physical dual-device robotic platform in 65 closed-loop runs using simulator-rendered planar images across three paths. All runs reached at least 0.95 maximum observed guidewire progress; two runs (3.1%) met the prespecified failure rule of three or more autonomous stop events. The results establish route-level performance on the tested platform; clinical image sequences and broader anatomy remain to be evaluated.

0.19

Occupancy Network-Guided Autonomous Robotic Partial Nephrectomy

cs.RO cs.CV ·2026-09-14 ·Ethan Kilmer, Pit Henrich, Jiawei Ge, Paul M. Scheikl, Laura Connolly +11 more
top venue similarity 0.60
Abstract

Autonomous soft-tissue cancer surgery has been limited to interventions on organ surfaces, because current systems cannot perceive and adapt to anatomy once it deforms or is cut. We introduce the first vision-guided autonomous system capable of performing complete tumor resections for partial nephrectomy. Our system integrates conditional occupancy networks, trained entirely in a physics-based simulation, that infer full 3-D anatomy (tumor, margin tissue, and kidney) from single-view partial point clouds. These occupancy networks maintain intraoperative tracking even as tissue is cut and deformed, enabling adaptive planning and execution. The surgical platform combines a depth camera for capturing surface point clouds, dual robotic arms for electrosurgical cutting and vacuum-based tissue manipulation, and an autonomous control strategy for tumor resection. In patient-derived hydrogel phantoms under an open partial nephrectomy setting, the robot performed eight consecutive autonomous tumor resections comprising 77 electrosurgical cuts, with all cuts achieving negative surgical margins and 1.61 $\pm$ 0.48 mm mean absolute margin error. This work demonstrates, for the first time, a foundation for supervised autonomous closed-loop, imaging-driven, margin-negative tumor removal in phantoms.

0.30

MoE-based Feature Adapter for Prompt-free Binary Coronary Artery Segmentation in X-ray Angiography

cs.CV ·2026-08-25 ·Lin Xi, Yingliang Ma
similarity 0.58
Abstract

Accurate segmentation of coronary arteries in X-ray angiography videos is essential for quantitative coronary analysis and image-guided interventions. However, accurate segmentation remains challenging because coronary vessels are thin and exhibit low contrast, while the presence of catheters, guidewires, and complex anatomical background structures can further interfere with vessel delineation. Existing U-Net- and Transformer-based models provide strong baselines, but their shared feature-adaptation pathways may be insufficient for heterogeneous angiographic appearances. In this paper, we propose a prompt-free mixture-of-experts (MoE) feature adapter for binary coronary artery segmentation. Built upon parameter-efficient Vision Transformer adapters, the proposed method uses multiple lightweight experts with input-dependent top-$k$ routing to adaptively refine vessel-related features while limiting active computational cost. Experiments on MOSXAV and external evaluation on XACV show that the proposed method outperforms representative baselines and improves cross-dataset generalisation. These results suggest that MoE-based adapter learning is effective for robust coronary artery segmentation in X-ray angiography videos.

0.26