CS Paper Radar

Readiness-Constrained Pre-Islanding Dispatch for Military Microgrids

Aidan Looney, Annie Weathers, Nicholas Judson

eess.SY math.OC ·submitted 2026-10-29 13:53 UTC · v2

Abstract

Military installation energy readiness depends on having sufficient resources to sustain mission-critical loads throughout a prolonged utility outage. This paper develops a method to help operators manage energy resources during normal grid-connected operation while preserving islanded readiness. A robust viability kernel identifies combinations of battery energy, fuel, and load-shifting capability sufficient to sustain critical load under uncertain demand and photovoltaic generation. A probability bound translates stochastic generator start failures and recovery into a deterministic generator count selected to meet a specified availability requirement at islanding. Case studies for a fourteen-day islanding requirement at 0.999 islanding-entry availability show that advance warning of an outage can be used to prepare resources to meet a higher readiness requirement before islanding begins. The case studies further demonstrate that economic-only operation and the evaluated fixed battery reserve policy can fail to sustain critical load for the required duration, whereas enforcing the resource-dependent requirement preserves readiness at a modest increase in modeled grid-connected operating cost. These results demonstrate how active resource management can preserve long-duration energy readiness. The framework also helps commanders understand how readiness changes with operating conditions, even when the available resources remain the same.

Comment
32 pages, 5 figures, 3 tables, submitted to Military Operations Research

Closest papers

Nearest neighbours by meaning across the whole index.

Adaptive Calibration of Day-Ahead Flexibility Reserve Requirements Under Distribution Shift

eess.SY ·2026-10-12 ·Napoleon Costilla-Enriquez, Yang Weng, Miguel A. Ortega-Vazquez
theory similarity 0.60
Abstract

The increasing integration of variable renewable generation introduces weather-driven variability and uncertainty into power-system operations. System operators manage the resulting deviations between day-ahead forecasts and real-time net load by scheduling upward and downward flexibility reserves. These requirements have traditionally been set using simple deterministic rules. Newer data-driven methods tailor reserves to forecasts and operating conditions. However, their reliability may deteriorate when conditions depart from the historical data. We address this limitation with a sequential framework that updates day-ahead reserve requirements as operating outcomes become available. Within this framework, Adaptive Conformal Inference targets the frequency of insufficient reserve, whereas Rolling Risk Control targets expected uncovered deviation, the mean residual beyond the scheduled reserve. We prove finite-horizon bounds on realized miscoverage and capped uncovered-deviation loss. We test the framework on real ERCOT data in a chronological deployment simulation that respects operational timing: outcomes from one day first affect the reserve schedule two days later. Training and validation use 2022--2023 data; the uninterrupted test covers 2024--2025. Coverage calibration achieves approximately 90% coverage, with upward and downward miscoverage near 5%. Risk calibration brings expected uncovered deviations close to their budgets while using 5.3% less reserve than the uncalibrated requirements. The framework thus produces adaptive reserve requirements that provably control the selected reliability metrics over finite horizons without assuming stationarity or exchangeability.

0.22

Resilience Enhancement of Distribution Grids Through a Three-Stage Framework for Scheduling Mobile Energy Storage Systems

eess.SY ·2026-09-24 ·Ali Abbasi, Kyri Baker
similarity 0.58
Abstract

As high-impact, low-probability disturbances such as extreme weather events increase in frequency, enhancing power grid resilience has become a critical priority. Mobile Energy Storage Systems (MESSs) have strong potential for helping with this purpose due to their high operational flexibility and fast deployability. They can be rapidly relocated to supply critical loads, support islanded operation, and adapt to changing conditions of the grid, making them a promising addition or alternative to conventional resilience-providing methods. This paper proposes a three-stage framework for scheduling MESS units. In the first stage (Normal Operation), charging/discharging scheduling of MESSs at buses is optimized for economic arbitrage. Upon receiving an early warning signal, the second stage (Proactive Positioning) shifts the focus to resilience. Here, the model determines the optimal staging points within the transportation network to minimize the expected time of arrival at critical loads, considering the probability distribution of line outages. The third stage (Dynamic Relocation) addresses the post-event restoration phase, in which MESSs are relocated in response to grid updates, such as subsequent line failures. Furthermore, a graph neural network-based solution approach is proposed to further enhance computational efficiency in determining the optimal placing of MESS units during the pre-allocation and relocation stages. The simulation results demonstrate that the proposed framework reduces expected energy not served and improves the restoration speed.

0.21

Quantifying the Unintentional Islanding Risk: A Comparative Study on Active Distribution Network

eess.SY ·2026-09-10 ·Harshit Nayak, Edoardo Daccò, Jose Luis Rueda Torres, Davide Falabretti
similarity 0.57
Abstract

The growing share of Inverter-Based Resources (IBRs) is changing the operation of modern Active Distribution Networks (ADNs), raising concerns for grid stability, protection, and reliability. In this paper, we investigate the dynamic behavior of a Medium-Voltage (MV) portion of an ADN during the transition from grid-connected to islanded operation. The study considers a Grid-Following (GFL) converter and Synchronous Generators (SGs) operated under two distinct regulation modes: a fixed-setpoint, non-regulating condition representative of present-day distribution networks, and an active frequency/voltage-regulating condition representative of SGs equipped with governor and AVR control. Detailed electromagnetic transient (EMT) models of both technologies have been developed in DIgSILENT PowerFactory that quantifies the sensitivity of island persistence to SG regulation mode and inertia. The results show that when DERs operate at a fixed power setpoint, the risk of forming a sustained, undetected electrical island is limited, since the isolated network drifts out of the protection thresholds within tens of seconds. Conversely, enabling frequency and voltage regulation on the SGs is sufficient to sustain an unintentional island indefinitely without triggering conventional protection, regardless of system inertia.

0.28

State-of-Charge Targets for Storage Participation in Two-Settlement Markets: Reliability, Price, and Compensation Impacts

eess.SY ·2026-11-13 ·Yichen Li, Alexandre Moreira, Ruiwei Jiang, Miguel Heleno, Julie Mulvaney-Kemp
hot direction similarity 0.56
Abstract

As energy storage assumes a larger role in electricity systems, market operation must coordinate its use across time to support reliability during periods of system stress. Minimum state-of-charge (SOC) targets provide a means of preserving energy for these periods, but their design shapes reliability, operating efficiency, and storage compensation. This paper evaluates alternative SOC target designs in a California-based day-ahead and real-time electricity market model. The comparison examines targets based on day-ahead schedules or rolling centralized dispatch, enforced at the individual-resource or system level, across seasons, stress conditions, and participant information settings. The results show that retaining more energy does not necessarily reduce load shedding: targets that restrict discharge can limit storage support during shortages. Under critical summer conditions, individual targets derived from rolling centralized dispatch reduce weekly load shedding by approximately 83--84\% relative to operation without targets. Lower RT clearing costs and average prices can coexist with higher storage compensation, reflecting the role of day-ahead positions and real-time deviations in determining settlement outcomes. These findings highlight the importance of coordinating energy retention with timely discharge and network deliverability when designing SOC requirements for storage participation in electricity markets.

0.25

Dynamic Operational Reserve Margin Assessment from Risk-Constrained Unit Commitment States

eess.SY stat.AP ·2026-09-02 ·Pratishtha Shukla, Shaked Regev, Evan J. R. Brody, Charles Foltz, Teja Kuruganti
similarity 0.56
Abstract

We propose Dynamic Reserve Margin (DRM) as a time-varying operational adequacy metric derived from risk-constrained unit commitment (RCUC) states. DRM quantifies reserve adequacy using the additional generation capacity that committed generators can provide within a 5-minute response window relative to uncertainty and contingency reserve requirements. We introduce a complementary Reserve Risk Envelope (RRE) metric to quantify operational reserve headroom in directly interpretable MW terms. A low-margin duration metric is further developed to quantify the persistence of reserve stress over an operating horizon. We use an IEEE 14-bus example to illustrate these concepts, followed by large-scale RCUC case studies under multiple operating scenarios. Results demonstrate that reserve requirements and ramp-accessible reserve capability can vary substantially across operating conditions, and that commitment decisions adapt to maintain reserve adequacy under changing system conditions. The proposed DRM and RRE metrics provide an interpretable operational characterization of reserve adequacy, reveal reserve accessibility and stress persistence that are not captured by conventional reserve margin metrics.

0.25

Water as a Battery: Using Hydropower Flexibility to Support the Grid

eess.SY ·2026-10-25 ·Chinmay Morankar, Abdullah Al Mehadi
published similarity 0.55
Abstract

This study presents a two-layer optimization framework to determine the optimal sizing of PV, wind, and battery storage co-located with existing hydroelectric plants to support rapidly increasing data center loads while minimizing cost, grid reliance, and transmission upgrades. The outer layer uses Particle Swarm Optimization (PSO) to select capacity combinations, while the inner layer performs rolling-horizon dispatch simulations to model hourly energy balance among PV, wind, hydro, and BESS, considering operational constraints. Two case studies were analyzed. At The Dalles Dam (Oregon), favorable wind resources and land availability enabled deployment of 111.2 MW PV and 117.9 MW wind, with no BESS required. Hydro flexibility allowed the system to meet the load with minimal grid support. In contrast, Conowingo Dam (Maryland) faced land constraints and limited renewables to 130 MW PV, leading to higher grid dependence. Co-locating hydro with renewables significantly enhances reliability and cost effectiveness by leveraging hydro's dispatchability to balance daily and seasonal variable generation from PV + Wind, reducing the need for storage or costly grid imports. This analysis provides a framework to meet the 99.9% availability targets of this new load type on the grid with sustainable energy resources.

0.32

Multi-Day Stochastic Dispatch for Power Systems With Long-Duration Storage Using Diffusion-Generated Weather Forecasts

eess.SY ·2026-10-12 ·Leonard Göke
benchmark similarity 0.55
Abstract

As power systems shift toward high shares of wind and solar, long-duration storage becomes pivotal for balancing multi-day deficits and surpluses of uncertain supply and demand. Current dispatch strategies for long-duration storage either assign a fixed value to stored energy or extend the modeled horizon using a single forecast. Stochastic system dispatch with a multi-day horizon for long-duration storage remains unexplored, and existing stochastic dispatch only considers day-ahead uncertainty or Markovian uncertainty beyond one week of perfect foresight. Therefore, we benchmark stochastic multi-day dispatch against deterministic alternatives in a rolling-horizon setup. To emulate probabilistic multi-day forecasts, we combine diffusion with a semi-Markov model of weather regimes and a logistic growth model for meteorological forecast errors. At high renewable shares, stochastic operation reduces thermal backup generation and consistently eliminates loss of load. The benefits decrease with smaller shares of renewables, less long-duration storage, or higher forecast skill. Overall, our results suggest that systems with high shares of variable renewables can substantially benefit from probabilistic multi-day forecasts and stochastic dispatch.

0.17

Planning-Stage Assessment of Battery-Supported Regional Islanding: A South Australian Case Study

eess.SY ·2026-11-11 ·Yunqi Wang, Nanduni Nimalsiri, Ghulam Mohy-ud-din, Thomas Brinsmead
similarity 0.55
Abstract

Power systems with high shares of renewable generation may face increased operational vulnerability under regional islanding caused by the loss of major inter-area transmission interfaces. This paper presents a planning-stage transmission-level assessment of regional islanding with battery storage, using a South Australian case study based on a synthetic representation of the Australian National Electricity Market (NEM). An interconnected planning baseline is compared with a stress test scenario involving complete regional-islanding over a 24-hour chronological horizon. The framework quantifies peak unserved power, total unserved energy, and the duration of unserved demand, while characterising battery redispatch and the synchronous inertia accessible to the subsystem.

0.30