Machine learning for remote electrocardiogram monitoring must handle noise and diseases absent from training under tight resource constraints. We investigate whether upstream unsupervised anomaly detection can improve monitoring decisions more efficiently than classifier-derived uncertainty. We evaluate five detectors on PTB-XL and BUT QDB and compare a two-stage filter-classifier system with Monte Carlo Dropout and deep ensembles under unseen-disease and noise conditions. Performance is averaged over five training seeds. We measure single-pass energy, latency, and graph memory on a microcontroller's central processing unit (CPU) and neural processing unit (NPU). Per-score neural network costs account for repeated evaluations but exclude scoring outside deployed graphs. Energy equations relate filtering and rejection to avoided classifier execution. Across four disease scenarios, Deep Support Vector Data Description (Deep SVDD) achieves the highest mean area under the receiver operating characteristic curve within all tested finite CPU energy budgets. On the NPU, it leads at 1 mJ, while Monte Carlo Dropout has slightly higher means at 10 and 100 mJ. With a narrow CPU classifier, the Deep SVDD two-stage system increases the fraction of correctly classified or correctly rejected inputs by 15.0-19.4 percentage points over classification without rejection. Estimated energy per input is 1.93-6.99 mJ, compared with 52.53 mJ for Monte Carlo Dropout and 8.76-17.51 mJ for deep ensembles, at each method's retrospectively selected test accuracy peak. These results support upstream filtering for efficient remote monitoring, while independent validation and complete-system measurements remain necessary.

Comment
21 pages, 7 figures

Closest papers

Nearest neighbours by meaning across the whole index.

Towards Myocardial Infarction Diagnosis: An Investigation into Machine Learning and Deep Learning Algorithms using ECG Data

eess.IV cs.CVcs.LG ·2026-10-26 ·Rafid Ahnaf, Husne Mubarak, Fahim Ahsan, G. M. Refatul Islam, Rafeed Rahman +1 more
similarity 0.65
Abstract · 18 pages, 7 figures, 3 tables. Based on the authors' undergraduate thesis at BRAC University (2023)

Myocardial Infarction (MI) is a severe and potentially fatal cardiac condition caused by myocardial injury due to ischemia, and timely detection can substantially reduce its mortality. Electrocardiography (ECG) is the primary diagnostic modality for MI, but manual interpretation is susceptible to human error. In this work, we propose Visionary V2, a multi-step, adaptive filtration method for ECG signal normalization, and use it to study machine learning (ML) and deep learning (DL) approaches to MI detection on the PTB Diagnostic ECG Database using all 15 available leads. On statistical features extracted from the filtered signals, such as the R-R interval, a Bagging ensemble of decision trees reaches 96.6% accuracy, compared with 87.7% when the signals are processed with BioSPPy. We further generate an image dataset from the filtered signals, on which a custom ResNet-50 misclassifies only 1 of 7,000 validation images and a custom CNN reaches an F1 score of about 98.7%. Finally, we apply LIME, Grad-CAM and Integrated Gradients to verify that the image models attend to the ECG waveform rather than the background. These results indicate that careful signal normalization combined with ML and DL models can support fast and accurate automated MI screening.

0.28

GNN-Enhanced TCN Algorithms for ECG Anomaly Detection

cs.LG ·2026-11-12 ·Angelica Simonetti, Ferdinando Zanchetta
published similarity 0.64
Abstract · Follow-up to arXiv:2310.02774, which introduced a pipeline for an industrial dataset. A shortened version of that earlier paper appeared in …

To a time series can be also given the structure of directed graph, opening the doors to the usage of graph neural networks (GNNs) in this context. In this paper we develop a new pipeline involving novel geometric deep learning models that merge the capabilities of ordinary TCNs with the ones of GNNs to solve an anomaly detection problem on electrocardiogram signals.

0.25

Deviation-Aware Pretraining for Cardiovascular Disease Detection from Electrocardiograms

cs.LG ·2026-11-10 ·Siyuan Yan, Haibo Zheng, Feng Lu, Wei Li
similarity 0.64
Abstract

Electrocardiogram (ECG) signals are critical for cardiovascular disease (CVD) detection. Most current deep learning models rely on supervised, task-specific training, which limits their ability to generalize across diseases, patient populations, and acquisition settings. This paper presents a self-supervised ECG feature extraction framework that learns from nearly one million unlabeled 12-lead ECG recordings. The framework includes two modules: Deviation Localization Embedding (DLE), which detects waveform-level deviations from normal patterns, and Association Reconstruction Embedding (ARE), which models cross-lead associations through deviation-guided reconstruction to capture abnormal patterns expressed across multiple leads. These modules enable the framework to capture subtle deviation-related patterns and their cross-lead context. The framework achieves up to 6.5% AUROC and 12.8% F1 improvements over prior methods on multiple public datasets, even without additional fine-tuning the pretrained feature extractor. Embedding visualizations show that the learned features support meaningful disease grouping and anomaly identification. The approach reduces the need for labeled data and can support clinicians in diverse healthcare settings. The framework has potential to improve early detection and monitoring of cardiovascular diseases, contributing to more accessible and equitable heart care.

0.20

Label-Efficient Deep Learning for ECG Delineation: A Multi-Dataset Benchmark against Widely Used Delineation Tools

cs.LG cs.AIcs.CVeess.SP ·2026-10-06 ·Jeonghwa Lim, Minje Park, Yeongyeon Na, Yujin Eom, Soyeon Lim +4 more
benchmarkcode/data similarity 0.63
Abstract · 20 pages, 5 figures. First two authors contributed equally

Electrocardiogram (ECG) delineation, the identification of waveform boundaries, is a foundational step that translates raw ECG signals into clinically interpretable measurements. Deep learning has advanced this task but remains dependent on costly expert annotations. Label-efficient strategies such as self-supervised pretraining and semi-supervised learning are expected to ease this burden, yet it remains unclear whether they yield reliable delineation and whether the deep models they produce outperform the delineation tools used in practice. We address this in two stages. First, comparing self-supervised objectives with supervised or semi-supervised fine-tuning across one internal and four external datasets, we find that pretraining helps but the objective matters, and that the value of semi-supervised fine-tuning depends on the pretraining objective. Second, we benchmark the selected deep learning model against widely used open-source (NeuroKit2, Prominence, ECGdeli) and commercial (CalECG) tools using three complementary metrics. The model ranks best on every metric and dataset, outperforming the strongest tool by a clear margin on the rhythm-diverse set (mIoU 71.3 vs. 54.8%; averaged point-wise sensitivity 92.6 vs. 76.4%), and degrades the least from sinus to arrhythmia. A rhythm-stratified and point-wise analysis further characterizes the distinctive behavior of each tool, yielding practical guidance for tool selection. These results provide systematic, multi-dataset evidence that self-supervised pretraining is effective for ECG delineation and enables a label-efficiently trained deep learning model to outperform widely used delineation tools by leveraging abundant unlabeled data. This supports adopting such models in diverse, real-world clinical settings.

0.30

TRACE: Tractable Routing Autoencoder for Clinical ECG

cs.LG ·2026-09-20 ·Shunbo Jia, Runze Ma, Haonan Lyu, Haijin Zhang, Qiang Yang +1 more
similarity 0.62
Abstract · 20 pages, 7 figures, 7 tables

Deep learning has advanced automated electrocardiogram (ECG) diagnosis, but the field's most accurate models, foundation models pretrained on millions of recordings, are not decision-pathway auditable: a clinician cannot trace a diagnosis to a physiological pathway or intervene on one. We propose TRACE, a Tractable Routing Autoencoder for Clinical ECG, whose 32-dimensional clinical latent space is specified in advance from domain knowledge rather than discovered by optimization. TRACE partitions this space into perfusion, structure, and conduction subspaces, routes each to its own diagnostic head by design, regularizes the partition with an orthogonality penalty, and reconstructs the ECG through a decoder that permits latent perturbation. On PTB-XL and Georgia, TRACE exceeds unconstrained classifiers and stays ahead of an ECG foundation model pretrained on ten million recordings, evaluated by linear probe on frozen features, at roughly an eighth of the parameter count. On the nine-label CPSC2018 cohort, which carries no structural class, the framework transfers with only the routing table re-specified to a perfusion/rhythm/conduction partition. Joint probe, erasure, and perturbation analyses verify the routing contract, and perturbing the depolarization and repolarization pathways modulates the reconstructed waveform. Removing the specified partition and its orthogonality penalty costs 1.70 AUC and 11.30 macro-F1 points on PTB-XL, and 2.76 AUC and 16.92 macro-F1 points on Georgia. A capacity-matched permutation control places arbitrary assignments within 0.34 AUC points of the ontology routing and leaves macro-F1 statistically level (p=0.619): the ontology supplies decision-pathway auditability at no macro-F1 cost.

0.32

Interpretable Stress Detection from ECG Signals Using Motif-Based Anomaly Analysis

eess.SP cs.LG ·2026-08-27 ·Zhanna Balyan, Sachin Kumar
similarity 0.62
Abstract

Stress detection using physiological signals has gained significant attention due to its impact on both physical and mental health. While existing approaches based on machine learning and deep learning achieve strong predictive performance, they often rely on black-box models and fail to capture individual variability in physiological responses. In this work, we propose an interpretable and personalized framework for stress detection using electrocardiogram (ECG) signals based on motif discovery and Matrix Profile analysis. Instead of training a classifier, the method learns subject-specific baseline cardiac behavior by extracting recurring heartbeat patterns (motifs) from ECG signals. Stress is then detected as a deviation from these baseline patterns using a distance-based anomaly score. Experiments are conducted on the WESAD dataset using a carefully designed train-validation-test protocol to ensure reliable evaluation. The results show that the proposed approach can effectively detect stress for several subjects while providing clear interpretability through direct comparison of ECG patterns. However, the performance varies across individuals due to differences in physiological responses, with some subjects exhibiting minimal morphological changes under stress. Additional analysis incorporating heart rate variability (HRV) features reveals that while HRV can improve performance in certain cases, its contribution is not consistent across all subjects. These findings highlight the importance of personalization and interpretability in physiological stress detection and demonstrate that motif-based approaches provide a meaningful alternative to black-box models, while also revealing inherent limitations due to inter-subject variability.

0.23

Accurate and Auditable ECG Classification via Visibility Graph Neural Networks

cs.LG cs.AI ·2026-10-30 ·Artur Xavier, Guilherme Henrique Gomes Evangelista, Aitazaz Khan, Antonio Luiz Pinho Ribeiro, Mohammed J. Zaki +2 more
hot direction similarity 0.62
Abstract · 43 pages, 10 figures, 21 tables, including Supplementary Information

Physicians read electrocardiograms (ECGs) from waveform shape and timing, yet accurate deep-learning classifiers rarely show which waveform regions drive their predictions. We introduce LYNX-ECG, a graph neural network that represents each heartbeat as a sparse visibility graph of timestamped turning points. On CODE-Test, LYNX-ECG reaches a macro F1 score of 0.889, outperforming five baselines including the ECGFounder foundation model, while its graphs need about 14% of the storage of graphs built from every sample. Because each node maps to a specific ECG time, we can delete clinically defined waveform regions and alter beat timing to audit predictions. For conduction disorders, the clinically expected region was the strongest evidence in more than 90% of correct predictions. Bradycardia and tachycardia calls follow heart rate with conduction intervals held fixed, and atrial fibrillation calls vanish when beat-to-beat variation is removed. Sparse visibility graphs thus pair accurate ECG classification with clinically grounded, testable explanations.

0.31

Revisiting Energy-based Tabular Anomaly Detection: Energy and Reconstruction are Complementary

cs.LG stat.ML ·2026-08-14 ·Junichiro Niimi
published similarity 0.62
Abstract · This is the author's version of a paper accepted at the 33rd International Conference on Neural Information Processing (ICONIP 2026)

Tabular anomaly detection is dominated by classical density-proxy methods (Isolation Forest, OCSVM, LOF), reconstruction-based detectors (Autoencoders, VAEs), and modern non-parametric scorers (COPOD, ECOD, Deep SVDD), all of which approximate the inlier distribution only indirectly; explicit energy-based models are largely absent. Motivated by the recent revival of EBMs in deep learning (e.g., Energy-Based Transformers, JEPA), we revisit the classical Deep Boltzmann Machine (DBM) for this task and hypothesize that its mean-field energy combines more effectively with a reconstruction-based score than same-lineage pairs do. We evaluate a two-hidden-layer DBM on two tabular benchmarks spanning distinct domains (UCI Bank Marketing and NSL-KDD) against eight classical and modern baselines across twenty random seeds. The DBM mean-field energy matches the strongest baseline (the Autoencoder) on Bank Marketing and statistically beats it on NSL-KDD, while significantly outperforming the remaining seven on both datasets. When fused with the Autoencoder via rank fusion, the DBM energy yields a statistically significant improvement on both datasets (AUROC=+0.014, p<0.01 on Bank Marketing; +0.002, p<0.001 on NSL-KDD); every non-DBM-derived base model instead fails to improve or significantly degrades the AE-paired ensemble. Our position is that classical EBMs, exemplified by the DBM, deserve a place in the tabular anomaly detection toolbox as a non-redundant complementary view to the reconstruction-based scores that dominate current practice.