CMS ECAL Phase-2 upgrade: characterisation and stability analysis of a three-stage low-voltage power-conversion system

Liv Anke Richter, Günther Dissertori, Werner Lustermann, Krzysztof Stachon

eess.SY physics.ins-dethep-ex ·submitted 2026-11-04 17:23 UTC · v1
unusual

Abstract

As part of the High-Luminosity upgrade of the Large Hadron Collider, the front-end electronics of the Compact Muon Solenoid electromagnetic calorimeter barrel are being replaced. A three-stage low-voltage power-conversion system supplies the upgraded electronics. As the cascade dynamics require characterisation to ensure stable operation, interactions between the three converter stages are assessed at their two interfaces using the Nyquist criterion. A validated shunt-injection setup using a Bode 100 frequency-response analyser provides in-situ impedance measurements under load to assess the accuracy of the averaged converter models. Results show that both interfaces are stable over the evaluated configurations, with modelled minimum distances to the critical point of 0.76 and 0.79, respectively. A turn-on study identifies capacitor charging at Stage 3 as the main cause of inrush currents triggering Stage 2 overcurrent protection. Two Stage 3 board variants stagger converter enables within and between boards, keeping the measured two-tower current below 5 A, within the 8.0 A protection threshold.

Comment
7 pages, 6 figures. Proceedings of the Topical Workshop on Electronics for Particle Physics (TWEPP 2026), 28 September - 2 October 2026, Castelldefels, Spain. Submitted to JINST

Closest papers

Nearest neighbours by meaning across the whole index.

Grid Integration of Gigawatt-Scale Hydrogen Hubs: A Multi-Timescale Stability Analysis and Connection Requirements for Weak Grid Environments

eess.SY ·2026-08-17 ·Mohamed Shamseldein
publishedcode/data similarity 0.46
Abstract

The global transition toward green hydrogen is driving the deployment of gigawatt-scale electrolysis centers, introducing a novel, converter-dominated load class to the bulk power system. Unlike conventional industrial loads, these facilities utilize extensive power electronics interfaces with fast dynamics comparable to Inverter-Based Resources (IBRs). This paper presents a comprehensive grid impact assessment of large-scale hydrogen hubs, focusing on harmonic injection, voltage stability in low Short Circuit Ratio (SCR) environments, and frequency response capabilities. Adopting a "full-spectrum" open-source modeling approach, the study utilizes PandaPower for large-scale steady-state contingency assessment; ANDES for electromechanical dynamic simulations to evaluate Fast Frequency Response (FFR); and ParaEMT for high-fidelity electromagnetic transient analysis of harmonic distortion and Low Voltage Ride-Through (LVRT). A critical finding of this study is that standard load models, including the generic PERC1 (data center) model, are insufficient for hydrogen hubs. The paper recommends specific structural modifications to the PERC1 model - specifically regarding process safety latches and restart voltage thresholds - to accurately capture the risk of prolonged plant tripping. Based on these findings, the paper proposes a set of standardized connection requirements to ensure secure integration.

0.57

Development of an EMT model of the Balearic power system

eess.SY ·2026-09-02 ·Yousef Pipelzadeh, Dharshana Muthumuni, Farid Mosallat, Javier Renedo, Silvia Sanz Verdugo +3 more
similarity 0.46
Abstract

The Balearic Islands are striving to achieve 100% renewable energy, which poses new challenges in operating the power system securely and reliably. With a higher integration of inverter-based resources (IBRs) and a reduced presence of conventional synchronous generators, the system strength, particularly short circuit levels, becomes weaker and more susceptible to disturbances; and the total inertia of the system becomes lower. Technology enablers are planned to achieve energy transition in the Balearic power system: a new 2x200 MW VSC-HVDC link (bipole with metallic return), Synchronous Compensators (SC) and Battery Energy Storage Systems (BESS), as fully-integrated network components. Detailed ElectroMagnetic Transient (EMT) simulation studies may be needed to analyse stability of the system, due to the high amounts of power-electronics devices in the system. This paper describes the implementation of an EMT model of the Balearic power system.

0.22

A Reusable Four-Port S-Parameter to Link-Level Signal-Integrity Analysis Framework for High-Speed Detector Interconnects

eess.SY hep-ex ·2026-08-10 ·D M S Sultan, D. Bortoletto, R. Plackett, A. E. McDougall, A. S. Rotelli +2 more
similarity 0.43
Abstract

A reusable MATLAB signal-integrity (SI) framework is presented that converts compatible four-port S-parameter data, measured by VNA or obtained from electromagnetic simulation, into traceable link-level evidence rather than a single loss metric. Its contribution is the checked, traceable automation of established SI operations while keeping source data, model assumptions, analytical projections, and finite-record observations distinct. The framework is demonstrated on the four 1.25 Gbps differential routes (DP1-DP4) of the PPCB-1347-MuPix11 probe card using PTSL CST Microwave 3D-Solver-derived four-port S-parameters and a virtual time-domain solver. The automated pipeline preflights file structures, performs a power-normalized mixed-mode transformation, applies route-length-aware loss decomposition, constructs a causally loaded channel model, and propagates full PRBS-31 sequences into eye-diagram, conditional-BER, and 8b10b-coded-link analyses. At the 1.25 Gbps data rate (Nyquist 0.625 GHz), DP1-DP4 exhibit differential insertion loss (SDD21) from -0.350 to -0.300 dB, differential-to-common conversion from -31.038 to -28.236 dBc, and modeled FEB-input eye openings from 0.586 to 0.588 V. The comparison shows that path length alone is not an adequate SI ranking variable: DP3 has the lowest Nyquist insertion loss, DP1 the strongest differential-to-common isolation, and DP4 the largest modeled eye. All analytical BER values remain below the reporting floor and therefore do not support a BER ranking. By preserving the distinction between route-dependent waveform behavior, model projections, and finite-record observations, the framework provides an extensible basis for comparative high-speed-interconnect SI analysis from design review through calibrated VNA measurement interpretation.

0.04

EMT Modeling and Coordinated Mode-Transition Ride-Through Control of Modern Data Centers

eess.SY ·2026-11-05 ·Junyuan Zheng, Salish Maharjan, Min Lwin, Soummya Roy, Zhaoyu Wang +3 more
similarity 0.43
Abstract

Large data centers are emerging as power-electronic loads whose response to grid voltage disturbances can affect bulk-system stability. This paper presents the composition and control characteristics of a proprietary electromagnetic transient (EMT) model of a modern data center comprising an uninterruptible power supply (UPS) with battery energy storage, induction-motor cooling loads, a computer room air handler (CRAH) driven by a variable-frequency drive (VFD), and an aggregated server load. A voltage-based state machine coordinates three aspects of the facility response: the UPS operating mode (eco, double conversion, or battery), the supply path of the CRAH, and a ramped reconnection of the grid-side UPS converter after the disturbance clears. A 100 MW facility is implemented in PSCAD/EMTDC and benchmarked against the PSSE PERC1 aggregate data center model under a symmetrical three-phase fault and low- and high-voltage ride-through (LVRT/HVRT) events. The two models agree closely in their voltage and active-power trajectories, while the EMT model also resolves the converter and motor-reacceleration transients that the phasor-domain model cannot.

0.50

Phase-Compensated Frequency-Scan Measurement of Harmonic Transfer Function Impedance

eess.SY ·2026-10-28 ·Yiyang Liao, Yitong Li, Jinjun Liu
similarity 0.43
Abstract

Impedance models obtained through frequency scanning provides terminal characterization for small-signal stability analysis without requiring detailed knowledge of internal converter parameters. When unbalanced steady-state components introduce cross-frequency coupling, conventional $2\times2$ impedance scan methods must be extended to identify harmonic transfer function (HTF) impedance. However, the measured phases of frequency-coupling terms depend on the starting time of the fast Fourier transform (FFT) window, potentially introducing phase errors when different time references are used. This paper presents a $dq$-domain measurement method of HTF impedance that explicitly accounts for this time dependence. Phase compensation aligns the measured Fourier coefficients to a common electrical phase reference, correcting the resulting phase discrepancies and enabling consistent impedance reconstruction. Comparisons with analytical models under balanced and unbalanced conditions verify the measurement method, recovering the conventional $2\times2$ impedance and the dominant coupling blocks of a $6\times6$ HTF representation, respectively.

0.34

EMT Assessment of SCR and X/R Effects on Current-Priority-Dependent LVRT Response of a Grid-Following BESS

eess.SY ·2026-10-30 ·Dileep Cheerla, Amirthagunaraj Yogarathnam, Divya Jain, Satish Natti
similarity 0.42
Abstract · 6 pages, 4 figures. Submitted to the 2027 IEEE Texas Power and Energy Conference (TPEC 2027)

Low-voltage ride-through (LVRT) forces a grid-following inverter to allocate finite converter current between active- and reactive-current objectives. This paper uses a PSCAD electromagnetic-transient (EMT) representation of an aggregated battery energy storage system (BESS) to quantify how short-circuit ratio (SCR) and grid impedance X/R ratio alter that tradeoff. Active-current priority and reactive-current priority are compared for five paired grid conditions under the same 150-ms balanced three-phase fault, with pre-fault active power approximately 0.84 pu, POI reactive-power exchange near 0 pu, and a 1.0-pu dq-current limit. Fundamental positive-sequence voltage and power are reconstructed from 100-$μ$s three-phase EMT outputs. Across the fixed-fault SCR sweep, the Q-priority late-fault voltage advantage increases from 0.046 pu in the strongest tested grid to 0.129 pu in the weakest; the weakest P-priority case also shows active-power reversal and a pronounced controller-frequency excursion. At fixed SCR, changing X/R produces a smaller increase from 0.092 to 0.112 pu, mainly through reduced P-priority voltage support. Because the common physical fault also deepens the passive retained-voltage condition as SCR decreases, the SCR result is interpreted as a fixed-fault grid-strength sensitivity rather than a constant-sag comparison. Grid strength is the larger sensitivity in the tested matrix, while X/R remains an additional modifier under the studied fault conditions.

0.37

An Integrated EMT Small-Signal Stability Analysis Tool for Power Systems with High Inverter-Based Resource Penetration

eess.SY ·2026-09-14 ·Zihao Qin, Xiaonan Lu, Shuan Dong, Jin Tan
published similarity 0.42
Abstract · 6 pages, 4 figures, 2 tables. Accepted for presentation at the 2026 IEEE Industry Applications Society (IAS) Annual Meeting

The ongoing replacement of synchronous generation by inverter-based resources (IBRs) introduces fast converter control dynamics whose characteristic frequencies extend beyond the classical electromechanical band. Conventional small-signal stability tools are commonly formulated in the phasor domain, representing electrical quantities as slowly varying phasors at the fundamental frequency, and therefore cannot resolve the sub-synchronous and converter-driven dynamics that increasingly arise in operation. Electromagnetic Transient (EMT) modeling captures these dynamics, but established EMT simulators produce time-domain waveforms rather than the modal indicators (eigenvalues, damping ratios, and participation factors) needed to assess stability risk. This paper presents EMT-SSA, an integrated tool suite for EMT-level small-signal analysis of IBR-rich power systems. From a standard PSS/E system snapshot (.raw/.dyr), it converts the model into an EMT representation with enhanced fidelity, solves an extended power flow for the steady-state equilibrium points of both the network and the device controllers, and linearizes a full-order EMT model to form the system state matrix, from which it produces eigenvalues, oscillation modes, and participation factor analysis results over a device library spanning synchronous generators, grid-following and grid-forming inverters, transmission lines, and loads. The EMT-SSA tool suite identifies poorly damped or unstable modes and attributes them to specific devices. The tool is demonstrated on the Kundur two-area system, with its modal results benchmarked against PSS/E NEVA.

0.16

A New Index for Quantifying Stability Adaptation Effort in Power Electronics-Dominated Power Systems Based on Frequency-Domain Impedance Identification

eess.SY ·2026-10-02 ·Luis A. Garcia-Reyes, Macarena Martin-Almenta, Edgar Nuño-Martínez, Javier Renedo, Antonio Cordón-Rodríguez +2 more
published similarity 0.41
Abstract · Paper in Proceedings of CIGRE Paris Session, C4-PS1, Paper ID 11553

The increasing use of converter based resources has made stability assessment in modern power systems more challenging, particularly because many devices are available only as black box models. Conventional eigenvalue based methods require full dynamic representations, while frequency domain impedance techniques based on the Generalized Nyquist Criterion (GNC) provide stability insight but do not quantify how much a converter must be retuned to restore stability. This paper introduces the Adaptation Effort Index (AEI), a metric that measures the sensitivity of dominant modes to parameter variations and quantifies the effort required for a converter to reconfigure itself under unstable operating conditions. The AEI combines the Nyquist Stability Margin obtained from frequency domain screening with a modal sensitivity index derived from fitted state space models synthesized from black box impedance data. The method is applied to a system comprising a grid forming and a grid following converter. Results show that, although both units can be tuned to stabilize the system, the grid following converter requires significantly less adaptation effort. The AEI therefore provides a practical and model agnostic tool for identifying which converter should be reconfigured in converter dominated grids, offering valuable guidance for system operators and manufacturers.

0.30