Environmental Assessment of GaN Current-Source and Voltage-Source AC-AC Variable Speed Drives

Luc Imperiali, Jonas Huber

eess.SY ·submitted 2026-11-09 11:06 UTC · v1

Abstract

Three-phase ac-ac converters for variable-speed drives can be realized conventionally as voltage-source converters (VSCs) or, leveraging emerging monolithic bidirectional GaN power transistors (M-BDSs), as current-source converters (CSCs). This paper presents a comparative life-cycle assessment of a realized VSC and a CSC demonstrators including grid-side and motor-side EMI filters, and with identical specifications (1.4 kW rated power, 200 V line-to-line rms grid and motor voltage). The embodied carbon footprints are similar (44.8 kgCO2eq for the VSC and 47.4 kgCO2eq for the CSC) and dominated by auxiliary and control electronics, and the printed circuit boards. Over 10 years of continuous operation under the NEMA Power Index mission profile for variable-load centrifugal systems (pumps, fans), the CSC's higher part-load efficiency translates into a clearly lower life-cycle carbon footprint of around 900 kgCO2eq compared to the VSC's 1130 kgCO2eq when operating with a carbon-intense electricity mix (440 gCO2eq/kWh). However, this difference almost vanishes when considering a future renewable electricity mix (25 gCO2eq/kWh).

Comment
Submitted to an IEEE journal

Closest papers

Nearest neighbours by meaning across the whole index.

Modularity is Not Enough: Demonstration of a Solderless 400 V DC, 2.5 kW Three-Phase Inverter

eess.SY ·2026-09-23 ·Luc Imperiali, Aaron Griesser, Jonas Huber
unusual similarity 0.57
Abstract · Submitted to an IEEE journal

This paper presents the design and experimental evaluation of a fully solderless realization of a 400 V, 2.5 kW GaN-based variable speed drive (VSD), using screw-clamped resin molds and rubber compression pads instead of soldered interconnections. The power stage uses 650 V GaN power transistors and is operated at a switching frequency of 200 kHz. The solderless demonstrator is compared to a soldered reference realization using an identical printed circuit board (PCB). Over 120 thermal cycles with heatsink temperatures up to 90 °C, the solderless contacts show no degradation in effective on-state resistances (including contact resistances). Separately, open-loop vibration sweeps from 5 Hz to 2 kHz with acceleration amplitudes above 10 g were performed on the solderless assembly and left the continuously powered demonstrator electrically intact; subsequent resistance and nominal-power checks likewise indicate no contact degradation. An initial life-cycle assessment (LCA) indicated a higher embodied carbon footprint for the solderless realization due to 3D-printed resin molds, whereas a prospectively evaluated injection-molding scenario reduces the carbon footprint to near that of the soldered reference. The solderless assembly furthermore enables non-destructive component replacement, as demonstrated after a power transistor failure, as well as component re-use. These results support the feasibility of repair-oriented, industrially relevant kilowatt-class solderless power converters.

0.26

How AI Load Swings Reduce Datacenter Power Conversion Efficiency

cs.AR eess.SY ·2026-10-23 ·Heetarth Joshi, Ali Alenezi, Fang Chen Lin, Prasad Enjeti, Xiaoyang Wang +1 more
similarity 0.57
Abstract

AI training and inference workloads make GPU power swing repeatedly between compute and communication phases. As a result, the cascaded converters in a datacenter rack keep moving between operating points with different efficiencies. This paper uses an energy based, cycle averaged method to quantify that effect along a 240 V AC to 400 V DC to 51 V DC rack power path, using measured efficiency curves of commercially available GaN based PFC and LLC converters. For a 1 Hz, 50% duty-cycle load swinging between 5 kW and 510 W, conversion efficiency falls to 95.97%, compared with 96.82% at the equivalent constant average load, a loss of 0.88%. When 51/48V to 1V point of load conversion to the chip rail is included, it is shown that the loss grows to 1.66% (89.45% vs. 90.96%). These results show that efficiency rated at average load overstates real world performance, and that the penalty grows with each load dependent conversion stage between the grid and the GPU.

0.24

Control of Isolated Four-Quadrant Single-Stage Three-/Single-Phase X-Rectifier for EV On-Board Chargers

eess.SY ·2026-10-20 ·Sven Weihe, Jonas Huber
similarity 0.53
Abstract · Submitted to an IEEE journal

The single-stage isolated eXtended-functionality rectifier (X-Rectifier) electric vehicle (EV) on-board charger (OBC) employs 650V GaN monolithic bidirectional power transistors (M-BDS) in the input stage, provides sinusoidal input currents and four-quadrant operation in three-phase and split/single phase grids without power derating, operates from asymmetrical three-phase mains, provides reactive power if needed, and supports extremely asymmetric phase loading in standalone vehicle-to-load (V2L) mode. This paper presents a new improved phase-modular control method for the X-Rectifier that enables tracking of arbitrary and independent phase current references regardless of the instantaneous grid voltage (i.e., enables four-quadrant operation). The method supports grid-tied (i.e., grid-to-vehicle, G2V, or vehicle-to grid, V2G) and grid-forming (i.e., V2L) operation. Further, aiming towards a practical realization of the X-Rectifier, the paper addresses implementation aspects of the M-BDS half-bridges, like commutation logic around the grid-voltage zero crossing, fault handling, and soft-switching behaviour. Finally, a realized 5.5 kVA hardware demonstrator of the X-Rectifier is used to validate the proposed control method experimentally for all operating modes, including grid-tied three- and single-phase four-quadrant operation (G2V, V2G, and full reactive power modes). Further, robust V2L operation is verified with real-world loads, i.e., in three-phase mode with asymmetrical loading of the phases including a woodworking power tool, and in single-phase mode with a high-power vacuum cleaner with high inrush current and hence momentary overload of the X-Rectifier demonstrator.

0.21

LunaDrive: A Delay-Compensated High-Voltage GaN FET-Based Motor Driver for Dynamic Robots with Flat BLDC Motors

cs.RO ·2026-09-18 ·Sota Yuzaki, Temma Suzuki, Hiromi Tada, Masanori Konishi, Kento Kawaharazuka +1 more
publishedunusual similarity 0.50
Abstract · Accepted at IROS2026, website - https://woodrobo.github.io/lunadrive/ , YouTube - https://youtu.be/iD8vzvis_5w

The performance improvement of high-power flat BLDC motors has accelerated the development of dynamic robots. However, many commercially available servo motors assume operating voltages of 48 V or lower, which limits the maximum rotational speed. Dynamic robots require rapid energy generation, so this voltage constraint restricts motion performance. Therefore, driving motors beyond the rated voltage is desirable to increase the instantaneous maximum speed. On the other hand, semiconductor devices used in motor drivers have a trade-off between voltage rating and current capacity. Conventional drivers using Si MOSFETs have difficulty achieving both high-voltage and high-current operation. Although GaN FETs are promising, compact drivers that can be mounted on the rear side of flat BLDC motors remain limited. In this study, a motor driver for high-power flat BLDC motors using GaN FETs is developed. The effect of delay compensation in the high-speed region beyond the rated operating range is also investigated. In the experiments, under 96 V operation, a continuous current of 30 A was achieved with a heat sink attached. A peak current of 80 A and a maximum electrical frequency of 3110 Hz were confirmed. A high-speed load lifting experiment driven by a LiPo battery 24S (100 V) was also conducted, demonstrating applicability to dynamic robot operation.

0.45

Beyond Tomorrow -- Electrification of Hard-to-Abate Sectors

eess.SY ·2026-09-28 ·Jonas Huber, Johann W. Kolar
similarity 0.47
Abstract · Submitted to IEEE magazine

Reaching net-zero greenhouse-gas (GHG) emissions requires deep electrification beyond ground transportation, buildings, and conventional industry automation. This article discusses direct electrification pathways for hard-to-abate sectors, which today account for 30% of global GHG emissions and include steel, cement, chemicals, aviation, and shipping. Whereas indirect electrification via hydrogen and synthetic fuels will remain indispensable for some applications, direct use of electricity is generally preferable from an efficiency perspective. We review selected emerging opportunities for power electronics in industrial process electrification, including steelmaking through hydrogen plasma smelting reduction or molten-oxide electrolysis, electrified cement production, high-temperature process heat, plasma-assisted chemistry, and electrochemical synthesis. Across these examples, power converters must interface with highly application-specific loads, ranging from low-voltage high-current electrolysis cells to dynamic plasma reactors and megawatt-scale induction heating systems. In addition, high-power grid interfaces and in-plant energy management/buffering solutions must be clarified. Thus, future electrified industrial processes open new "beyond-tomorrow" research challenges for power electronics in close interdisciplinary collaboration with scientists from neighboring disciplines.

0.26

Comparison of Open-Source PSCAD EMT Models for Large-Scale AI Data Centers in Smart Grids

eess.SY ·2026-11-17 ·Alex Chen, Ahmad Mohammad Saber, Deepa Kundur
similarity 0.46
Abstract · 5 pages, 2 figures, submitted to PESGM 2027

The rapid deployment of artificial intelligence data centers (AIDCs) introduces gigawatt-scale, highly nonlinear, and fast-varying electronic loads that challenge grid voltage regulation, frequency stability, and disturbance ride-through. Capturing their transient behavior during grid faults and rapid computational workload swings requires high-fidelity electromagnetic transient (EMT) simulations rather than root mean square models. However, limited methodologies exist to audit the component-level adequacy of EMT AIDC models. This paper proposes a software-agnostic, 41-point fidelity framework spanning 11 categories that synthesizes 37 criteria from an existing modeling guideline with four novel requirements: frequency ride-through compliance, disaggregated fan and chiller cooling loads, temperature-dependent thermal response, and DC information technology (IT) load representations. Applying this framework to the four publicly available AIDC models in PSCAD/EMTDC reveals varying degrees of completeness: while the models capture IT load transitions, uninterruptible power supplies, and transfer switches for bulk stability studies, critical gaps remain in electro-thermal cooling coupling, internal protective relaying, and site-level controls. Addressing these gaps will enable comprehensive protection coordination and ride-through compliance studies.

0.22

Evaluating Grid Strength with Rising Penetration of Inverter Based Resources

eess.SY ·2026-09-22 ·Mohammed N. Khamees, Gad Ilunga, Zhongxia Zhang, Richard E. Tuck
published similarity 0.44
Abstract · Accepted for publication in 2026 CIGRE USNC Grid of the Future (GOTF) Symposium

Over the years, Dominion Energy Virginia (DEV) has experienced recurring power quality disturbances, including voltage and power oscillations, particularly in areas with significant inverter-based generation. While these phenomena suggest a potential relationship to system strength, no definitive correlation has yet been established. This paper presents methodologies for assessing system strength across the DEV network and identifying regions that may be vulnerable to such disturbances. To this end, three grid-strength metrics are evaluated: the Simple Short-Circuit Ratio (SSCR), the Weighted Short-Circuit Ratio (WSCR), and the Composite Short-Circuit Ratio (CSCR). Historical event data will be analyzed using steady-state snapshots from DEV's proprietary Analysis on Demand (ANODE) platform, which provides 10-minute interval load-flow data. These snapshots will be processed using a developed software tool to compute system strength metrics. The analysis will investigate potential correlations between system strength and observed disturbances. Where such correlations are identified, the study will further evaluate the impact of deploying synchronous condensers (SynCons) as a mitigation strategy.

0.31

Protection challenges and solutions on power systems towards 100% inverter-based resources and energy storage systems

eess.SY ·2026-11-02 ·Alexander Novikov, Luis A. Garcia-Reyes, Anup Joshi, Ahmar Farooque, Junaid Khalid +1 more
published similarity 0.43
Abstract · Danmarks Tekniske Universitetet, Katholieke Universiteit Leuven, Department of Electrical Engineering, Electrical Energy Computer Architectu…

The decarbonization of the energy sector, driven by the Paris Agreement and the European Green Deal, is increasing the share of renewable energy sources (RES) in power systems. Unlike traditional systems, RES-based systems rely on power electronic converters, which creates unprecedented challenges for reliability and resilience. The future power system is expected to combine a low-level AC layer with an upper-level High Voltage Direct Current (HVDC) backbone, which requires new understanding of fault protection, stability, and interaction between AC and DC components, as well as new models and simulation tools. This is especially critical in systems moving towards 100 percent converter-based generation. Protection systems detect, locate, and isolate faults to protect assets while the rest of the system keeps operating. Traditionally, they rely on the large fault currents supplied by synchronous machines. In modern systems, converter controls limit the fault current contribution to about 120 percent of rated current, so relays that distinguish faults from normal overcurrents based on current level may operate incorrectly. In addition, inverter-based resources (IBR) may not inject enough negative and zero sequence current for directional relays to work properly, and converters hold the voltage at a fixed value only within their reach, beyond which it drops quickly. As a result, existing protection schemes may not provide the expected accuracy and reliability. This report reviews the protection challenges identified in recent academic literature for power systems with high shares of converter-based resources. It covers the specific characteristics of RES, the challenges for protection with intelligent electronic devices (IED), the challenges of converter control during faults, and the main solutions proposed in research over the last decade.