CS Paper Radar

Modularity is Not Enough: Demonstration of a Solderless 400 V DC, 2.5 kW Three-Phase Inverter

Luc Imperiali, Aaron Griesser, Jonas Huber

eess.SY ·submitted 2026-09-23 15:08 UTC · v1
unusual

Abstract

This paper presents the design and experimental evaluation of a fully solderless realization of a 400 V, 2.5 kW GaN-based variable speed drive (VSD), using screw-clamped resin molds and rubber compression pads instead of soldered interconnections. The power stage uses 650 V GaN power transistors and is operated at a switching frequency of 200 kHz. The solderless demonstrator is compared to a soldered reference realization using an identical printed circuit board (PCB). Over 120 thermal cycles with heatsink temperatures up to 90 °C, the solderless contacts show no degradation in effective on-state resistances (including contact resistances). Separately, open-loop vibration sweeps from 5 Hz to 2 kHz with acceleration amplitudes above 10 g were performed on the solderless assembly and left the continuously powered demonstrator electrically intact; subsequent resistance and nominal-power checks likewise indicate no contact degradation. An initial life-cycle assessment (LCA) indicated a higher embodied carbon footprint for the solderless realization due to 3D-printed resin molds, whereas a prospectively evaluated injection-molding scenario reduces the carbon footprint to near that of the soldered reference. The solderless assembly furthermore enables non-destructive component replacement, as demonstrated after a power transistor failure, as well as component re-use. These results support the feasibility of repair-oriented, industrially relevant kilowatt-class solderless power converters.

Comment
Submitted to an IEEE journal

Closest papers

Nearest neighbours by meaning across the whole index.

Environmental Assessment of GaN Current-Source and Voltage-Source AC-AC Variable Speed Drives

eess.SY ·2026-11-09 ·Luc Imperiali, Jonas Huber
similarity 0.57
Abstract · Submitted to an IEEE journal

Three-phase ac-ac converters for variable-speed drives can be realized conventionally as voltage-source converters (VSCs) or, leveraging emerging monolithic bidirectional GaN power transistors (M-BDSs), as current-source converters (CSCs). This paper presents a comparative life-cycle assessment of a realized VSC and a CSC demonstrators including grid-side and motor-side EMI filters, and with identical specifications (1.4 kW rated power, 200 V line-to-line rms grid and motor voltage). The embodied carbon footprints are similar (44.8 kgCO2eq for the VSC and 47.4 kgCO2eq for the CSC) and dominated by auxiliary and control electronics, and the printed circuit boards. Over 10 years of continuous operation under the NEMA Power Index mission profile for variable-load centrifugal systems (pumps, fans), the CSC's higher part-load efficiency translates into a clearly lower life-cycle carbon footprint of around 900 kgCO2eq compared to the VSC's 1130 kgCO2eq when operating with a carbon-intense electricity mix (440 gCO2eq/kWh). However, this difference almost vanishes when considering a future renewable electricity mix (25 gCO2eq/kWh).

0.24

Experimental Characterization of SMD Inductors for Cryogenic Power Conversion at 4 K

eess.SY ·2026-10-20 ·Rami Rasheedi, Umeshkumar Patel, Jonathan Baldwin, Antonino Miceli, Inna Partin-Vaisband
unusual similarity 0.46
Abstract

With the increasing complexity and scalability demands of cryogenic electronic systems, such as quantum computing platforms, conversion of power within the cryogenic environment has become a primary concern. Magnetic inductors are among the key components affecting converter performance, as their electrical and magnetic properties can change significantly at low temperatures. In this paper, five commercially available Vishay SMD power inductors are experimentally characterized down to 4 K: DC resistance is measured continuously during cooldown, while frequency-dependent AC inductance and resistance are measured up to 2 MHz at both room temperature and 4 K. The results show substantial DC resistance reductions of 25x-58x at 4 K, while the inductance degrades by only about 5-5.5%. Although cryogenic operation slightly increases the AC resistance (due to the intensified skin effect) and raises core losses, converter-level analysis shows an inductor-only efficiency improvement of approximately 5.3-6.9 percentage points at 1 A, and up to 22.8 points at 3 A. The measured frequency-dependent impedance of each inductor is imported into Cadence and a complete single-phase 24 V-to-1 V buck converter with GaN power devices is simulated at 1, 2, and 3 A at 4 K. The full-converter efficiency at 4 K is shown to improve by 3.0-5.2 percentage points at 1 A and by up to 22.5 points at 3 A for the AC-characterized devices. These findings indicate that commercially available off-the-shelf power inductors remain operationally viable under cryogenic conditions and can simultaneously increase inductor efficiency and reduce the overall power loss in cryogenic power conversion systems.

0.24

LunaDrive: A Delay-Compensated High-Voltage GaN FET-Based Motor Driver for Dynamic Robots with Flat BLDC Motors

cs.RO ·2026-09-18 ·Sota Yuzaki, Temma Suzuki, Hiromi Tada, Masanori Konishi, Kento Kawaharazuka +1 more
publishedunusual similarity 0.44
Abstract · Accepted at IROS2026, website - https://woodrobo.github.io/lunadrive/ , YouTube - https://youtu.be/iD8vzvis_5w

The performance improvement of high-power flat BLDC motors has accelerated the development of dynamic robots. However, many commercially available servo motors assume operating voltages of 48 V or lower, which limits the maximum rotational speed. Dynamic robots require rapid energy generation, so this voltage constraint restricts motion performance. Therefore, driving motors beyond the rated voltage is desirable to increase the instantaneous maximum speed. On the other hand, semiconductor devices used in motor drivers have a trade-off between voltage rating and current capacity. Conventional drivers using Si MOSFETs have difficulty achieving both high-voltage and high-current operation. Although GaN FETs are promising, compact drivers that can be mounted on the rear side of flat BLDC motors remain limited. In this study, a motor driver for high-power flat BLDC motors using GaN FETs is developed. The effect of delay compensation in the high-speed region beyond the rated operating range is also investigated. In the experiments, under 96 V operation, a continuous current of 30 A was achieved with a heat sink attached. A peak current of 80 A and a maximum electrical frequency of 3110 Hz were confirmed. A high-speed load lifting experiment driven by a LiPo battery 24S (100 V) was also conducted, demonstrating applicability to dynamic robot operation.

0.45

How AI Load Swings Reduce Datacenter Power Conversion Efficiency

cs.AR eess.SY ·2026-10-23 ·Heetarth Joshi, Ali Alenezi, Fang Chen Lin, Prasad Enjeti, Xiaoyang Wang +1 more
similarity 0.44
Abstract

AI training and inference workloads make GPU power swing repeatedly between compute and communication phases. As a result, the cascaded converters in a datacenter rack keep moving between operating points with different efficiencies. This paper uses an energy based, cycle averaged method to quantify that effect along a 240 V AC to 400 V DC to 51 V DC rack power path, using measured efficiency curves of commercially available GaN based PFC and LLC converters. For a 1 Hz, 50% duty-cycle load swinging between 5 kW and 510 W, conversion efficiency falls to 95.97%, compared with 96.82% at the equivalent constant average load, a loss of 0.88%. When 51/48V to 1V point of load conversion to the chip rail is included, it is shown that the loss grows to 1.66% (89.45% vs. 90.96%). These results show that efficiency rated at average load overstates real world performance, and that the penalty grows with each load dependent conversion stage between the grid and the GPU.

0.24

AI for Science with GPT-6 Astra: Thermal Design and Electrothermal Analysis of 2D CFET

cs.AI cond-mat.mtrl-scics.AR ·2026-09-15 ·Min-Hui Kim, Khushi Sharma, Sarah Zhang, Ye Wang
similarity 0.43
Abstract

Thermal optimization of 2D CFET inverters requires testing structural proposals against their electrical costs. We examine these research tasks using an AI agent workflow within a supplied electrothermal model. At 12 nm, Astra selects a redistributed source-interconnect geometry, while a coordinating agent proposes a substrate-directed heat-removal path. The combined design reduces peak temperature rise by 1.67 K at fixed metal volume and 20 μW. A subsequent metal-resistance sensitivity gives about 0.6-K inverter cooling alongside a 2% nFET on-current loss. Effective contact-length scaling further shows that lower temperature can accompany higher thermal resistance when current falls. Reproduction identifies agreeing implementations and retains a 104.95-K failure for diagnosis. These results show that an AI scientist workflow can propose thermal structures, test them under common constraints, and quantify their electrical cost.

0.35

Control of Isolated Four-Quadrant Single-Stage Three-/Single-Phase X-Rectifier for EV On-Board Chargers

eess.SY ·2026-10-20 ·Sven Weihe, Jonas Huber
similarity 0.43
Abstract · Submitted to an IEEE journal

The single-stage isolated eXtended-functionality rectifier (X-Rectifier) electric vehicle (EV) on-board charger (OBC) employs 650V GaN monolithic bidirectional power transistors (M-BDS) in the input stage, provides sinusoidal input currents and four-quadrant operation in three-phase and split/single phase grids without power derating, operates from asymmetrical three-phase mains, provides reactive power if needed, and supports extremely asymmetric phase loading in standalone vehicle-to-load (V2L) mode. This paper presents a new improved phase-modular control method for the X-Rectifier that enables tracking of arbitrary and independent phase current references regardless of the instantaneous grid voltage (i.e., enables four-quadrant operation). The method supports grid-tied (i.e., grid-to-vehicle, G2V, or vehicle-to grid, V2G) and grid-forming (i.e., V2L) operation. Further, aiming towards a practical realization of the X-Rectifier, the paper addresses implementation aspects of the M-BDS half-bridges, like commutation logic around the grid-voltage zero crossing, fault handling, and soft-switching behaviour. Finally, a realized 5.5 kVA hardware demonstrator of the X-Rectifier is used to validate the proposed control method experimentally for all operating modes, including grid-tied three- and single-phase four-quadrant operation (G2V, V2G, and full reactive power modes). Further, robust V2L operation is verified with real-world loads, i.e., in three-phase mode with asymmetrical loading of the phases including a woodworking power tool, and in single-phase mode with a high-power vacuum cleaner with high inrush current and hence momentary overload of the X-Rectifier demonstrator.

0.21

Adaptive Inductor and Frequency Management for Integrated Power Converters

eess.SY ·2026-10-05 ·Rami Rasheedi, Salma Abdelzaher, Inna Partin-Vaisband
unusual similarity 0.40
Abstract

This work presents a digitally controlled adaptive power conversion framework that dynamically co-optimizes inductor configuration and switching frequency to achieve high efficiency across a wide range of load conditions. Conventional buck converters are typically optimized for a single operating point, leading to efficiency degradation under dynamic loads due to mismatches between inductance, switching frequency, and load current. To address this limitation, a reconfigurable inductor architecture is proposed. With this approach, the effective inductance and switching frequency are adjusted at runtime with on-chip digital controller. An end-to-end design methodology is developed, integrating physics-based analytical modeling, finite element method (FEM) simulations, and an optimization framework to determine preferred operating points across the load range. The resulting configurations are stored in a lookup table and implemented in real time through a low-overhead control scheme. The system explicitly accounts for both inductor and switching device losses, enabling co-optimization of conduction and switching losses within current ripple and continuous conduction mode (CCM) constraints. To ensure robust operation under fast load transients, a hysteresis-based control strategy is introduced to mitigate temporary CCM violations caused by sensing latency. An entry-margin condition is derived under which continuous conduction is guaranteed for a bounded load slew rate. Simulation results demonstrate a 4.5 percentage-point improvement in average efficiency and up to a 32% reduction in average power loss relative to fixed configurations, highlighting the effectiveness of adaptive inductance-frequency management in integrated power delivery systems with dynamic load profiles.

0.53

From Natural Language to Real Schematics: An Automated Workflow for Power Electronics Schematic Synthesis

cs.AI ·2026-10-28 ·Bowen Su, Huan Chen, Jiahua Ying, Ran Ou, Weilong Chen +2 more
similarity 0.40
Abstract

Designing power electronics converters traditionally requires intensive human expertise across topology sizing, commercial component selection, circuit simulation verification, and schematic drafting. While Large Language Models (LLMs) show promise in electronic design automation (EDA), applying standalone LLMs directly to board-level power electronics schematic synthesis suffers from severe engineering hallucinations, including inaccurate analytical sizing, fabricated or mismatched component part numbers, violated voltage derating margins, and broken topological connectivity. In this paper, we propose a Bounded Dual-Loop Automated Schematic Synthesis Framework that translates natural language specifications into verified, editable KiCad schematics and manufacturing deliverables. Our workflow integrates six stages across three functional columns: (1) requirement parsing and knowledge-driven power stage synthesis covering non-isolated (Buck, Boost) and isolated/resonant (Flyback, DAB, half-bridge LLC) topologies; (2) contract- and evidence-coordinated component selection grounded in distributor APIs and OEM datasheets, coupled with closed-loop ngspice transient verification and stress feedback; and (3) modular control hardware integration and multi-format deliverable generation featuring native KiCad netlist round-trip verification. End-to-end case studies on a 24-36V to 12V,2A Buck converter (29 positions, 83 verified terminals) and an isolated 48V to 24V, 0.5A, Dual-Active Bridge (DAB) converter (87 positions, 341 verified terminals), alongside comparative evaluations against a Vanilla LLM baseline, demonstrate that our framework improves component verification coverage from 22.2 to 98.6, nominal value consistency from 0 to 97.7, and SPICE simulation pass rates from 0 to 100.