Abstract

Woody breast (WB) myopathy is a spatially heterogeneous fibro-degenerative condition of the broiler Pectoralis major muscle. Existing mechanical reference methods rely on single-point or sequential compression measurements, limiting characterization of spatial hardness variability. This study presents TACTUS (Tactile Adaptive Conformal 3D Uniform Sensing), an automated tactile array that generates thickness-normalized, three-dimensional hardness maps at 20 anatomically distributed locations within approximately 30 s. TACTUS integrates 20 independently motorized tactuators with force-sensing resistors and encoder-driven linear actuators, alongside a LiDAR depth camera for surface profiling and adaptive compression. The system was evaluated using 100 broiler breast fillets across four WB severity classes (Normal, Mild, Moderate, Severe). TACTUS identified significant force differences among severity classes (ANOVA, p < 0.001), with the strongest differentiation in the cranial region and a significant caudal effect not detected by texture-analyzer measurements. Fillet-level TACTUS force showed moderate but significant correlation with texture-analyzer measurements (Pearson r = 0.441, p < 0.001). Semivariogram, local change entropy, and heterogeneity analyses revealed increasing and anatomically structured hardness variability with WB severity. These findings demonstrate TACTUS as an automated, operator-independent platform for spatially resolved mechanical characterization and ground-truth generation to support hyperspectral and near-infrared spectroscopy-based WB classification systems.

Closest papers

Nearest neighbours by meaning across the whole index.

Hall Effect-Based Tactile Force Detection Sensor for Robot-Assisted Minimally Invasive Surgery

cs.RO ·2026-10-07 ·Charles DeLorey, Michael Brockdorff, Adam Metcalf, Benjamin Calmé, Pietro Valdastri +1 more
similarity 0.61
Abstract · 9 pages, 12 figures

Robotic minimally invasive surgery has revolutionized surgical practice. However, as the surgeons are mechanically separated from the surgical tools, loss of tactile feedback occurs. We present a compact force sensor with three, millimeter scale sensing elements (taxels) that can be affixed to the grasping face of a robotic surgical tool. The sensor features a miniaturized design using Hall effect sensors and magnets embedded in a deformable elastomer contact layer. Sensor calibration is achieved with a 6 degree of freedom (DoF) parallel robot. Each taxel can detect applied normal and shear forces with average RMSE of 2.133 kPa. The calibrated sensor was validated on phantom and ex vivo porcine tissue, demonstrating tactile sensing during retraction as well as slip. This work introduces a small-scale Hall effect based tactile sensor, enabling sensing for force-sensitive robotic surgical applications.

0.17

MISTac: A Vision-Based Tactile Sensor for Minimally Invasive Surgery

cs.RO ·2026-08-14 ·Robin Koch, Annabella Mascot, Rayan Younis, Martin Wagner, Stefanie Speidel +3 more
code/data similarity 0.59
Abstract · This work has been submitted to the IEEE for possible publication

Minimally invasive and robot-assisted surgery offer many advantages over traditional open surgery, but deprive surgeons of tactile feedback and the ability to palpate tissue with their fingers. To address this lack of tactile feedback, we introduce the MISTac, a high resolution vision-based tactile sensor specifically designed for palpation in MIS. The sensor has a replaceable sensor tip with a diameter of 8 mm which allows it to fit through the trocars used in minimally invasive surgery. Its modular 3D-printed case design allows the use of bulky off-the-shelf illumination and imaging hardware that can easily be exchanged and upgraded. The sensor has an optical resolution of 176.68 $μm$, a tactile resolution of 250 $μm$, and can resolve forces as little as 24.3 mN. An in vivo study with the sensor shows its usability in minimally invasive surgery. We trained a machine learning model with the tactile data collected in the trial on a tissue classification task achieving an aggregate accuracy of ~84% in a leave-one-out cross validation. Tactile sensors have the potential to one day aid surgeons during minimally invasive surgery with tasks such as tissue classification or intra-operative tumor localization; MISTac is a small step towards this vision. We open-source MISTac at https://github.com/lasr-lab/mistac

0.26

Robotic Physical Comparison of Biologically Motivated and Counterfactual Sensory Arrangements using Biomimetic Skin

cs.RO ·2026-10-19 ·Akihiro Miki, Shun Hasegawa, Yoshimoto Ribayashi, Yuta Sahara, Kento Kawaharazuka +1 more
publishedcode/data similarity 0.56
Abstract · Published in Bioinspiration & Biomimetics (IOP Publishing). Project page: https://poyotamu000.github.io/biomimetic-skin-sensory-arrangements…

Human skin contains diverse mechanoreceptors, including Merkel cells and Pacinian corpuscles, each localized in specific regions. Although their spatial organization is known to be shaped by molecular signaling and neural induction during development, experimentally examining its functional significance under controlled conditions in living systems remains challenging. In particular, physically comparing alternative receptor arrangements that do not occur biologically is difficult. In this study, we developed a layered biomimetic robotic skin designed to mimic key structural features of human skin tissue by embedding receptor-analog sensors within compliant soft media. Using this platform, we implemented both biologically motivated and counterfactual sensory arrangements and quantitatively evaluated their performance across three passive tactile tasks: detection of weak contacts, a two-point discrimination-like assessment, and texture identification. Arrangements reflecting key features of the biologically motivated sensory organization exhibited higher performance than the alternative configurations examined. This study addresses a biological question concerning how spatial organization influences tactile function by presenting a biomimetic robotic approach that enables physical and empirical comparison of biologically motivated and counterfactual sensory arrangements that are difficult to investigate in living systems.

0.61

Non-Imaging Optical Tactile Sensors for Robotics: Transduction Principles, System Integration, and Robotic Applications

cs.RO ·2026-11-16 ·Hao Wu, Yu Feng, Haotian Guo, Huichan Zhao, Changsheng Wu +1 more
similarity 0.56
Abstract · 35 pages, 9 figures

Non-imaging optical tactile sensors encode contact through changes in optical intensity, wavelength, spectra, or photon counts, offering diverse architectures for robotic touch. Their usefulness depends on whether contact variables can be reliably distinguished from coupled mechanical and environmental effects, and whether the resulting information can be delivered in time to guide action. This review develops a unified framework linking mechanical load transmission, optical encoding, readout, and tactile inference to robotic task requirements. It examines reflective and waveguide-based devices, micro/nanofibers, fiber gratings, interferometric and resonant structures, and mechanoluminescent composites. Three considerations emerge across these approaches. First, high optical sensitivity supports accurate tactile estimation only when target variables remain identifiable under the relevant contact and calibration conditions. Second, spatial coverage and feedback timing must be assessed at the system level, accounting for multiplexing, acquisition, demodulation, and inference. Third, device characterization, offline recognition, and closed-loop robotic performance provide distinct levels of evidence and require different evaluation criteria. Representative studies illustrate how these considerations shape force estimation, contact localization, slip correction and distributed interaction. This review concludes with priorities for calibration transfer, reliable interfaces, scalable readout, and task-based validation, providing a basis for selecting and developing non-imaging optical tactile architectures for robotics.

0.16

Tactus: Tactile & Pose Sensing Glove for Natural Dexterity Data Collection

cs.RO cs.AIcs.ARcs.LG ·2026-10-29 ·Li Guan, Rachael Granberry, Sahar Aseeri, Sahar Rostami, Taylor Niehues +99 more
similarity 0.56
Abstract · 9 pages

Collecting naturalistic human manipulation demonstrations with accurate contact force and hand pose is essential for robot dexterous manipulation policy and foundational world model learning - yet no existing wearable platform provides both calibrated fingertip force sensing and occlusion-resilient hand tracking in a form factor that preserves natural manipulation behavior. We present Tactus, a textile-integrated sensing glove that co-optimizes three design pillars: (1) a thin, conformal 3D-knit form factor (1.5 mm fingertip stackup) designed to minimize interference with natural manipulation, (2) strategically placed capacitive tactile sensors at manipulation-relevant regions informed by empirical contact studies, and (3) IMU-fused pose tracking that maintains accuracy through the hand-object occlusions where manipulation data is most valuable. Tactus includes a documented calibration pipeline for cross-glove consistency and per-session calibration for subject-dependent correction. To enable objective comparison, we introduce standardized benchmarking protocols for tactile force regression and hand pose estimation, and apply them to Tactus and two commercially available tactile gloves - to our knowledge the first quantitative cross-platform evaluation of this kind. Tactus resolves a minimum detectable force of 0.59 N at 95% confidence, 1.6 - 2.7x lower than the commercial baselines, and with 0.87 cross-participant consistency, while our pose tracking sustains 11.0 mm fingertip keypoint relative error during manipulation, when occlusion is heaviest. We show that these combined signals support object property estimation, slip detection, and representative recording of hand-object interaction - yielding demonstration data with the fidelity required for contact-aware manipulation policies and world models.

0.21

VecTile: A Low-Cost Flexible Tactile Array for 3-DoF Force Sensing

cs.RO ·2026-10-22 ·Jian Hou, Xin Zhou, Adam J. Spiers
similarity 0.54
Abstract · 8 pages, 8 figures. Submitted to IEEE International Conference on Robotics and Automation (ICRA) 2027

Tactile sensing provides robots with contact information difficult to obtain from vision alone. Shear force is particularly important for understanding tangential contact, guiding corrective motions, and maintaining grasp stability, yet flexible and low-cost tactile arrays often measure only normal force. We introduce VecTile, a low-cost, 6 mm thin, flexible tactile array capable of three-axis force sensing. VecTile combines a piezoresistive layer with passive silicone nubs that convert normal and shear forces into distinguishable pressure patterns. The sensor can be fabricated in-house without specialized equipment. The complete system costs less than 35 USD for a 4x4 array. We validate the sensing mechanism through finite element analysis and hardware experiments. In controlled single-taxel tests over 1-5 N normal force and up to 1.5 N shear force, VecTile achieves root-mean-square errors of 0.39 N and 0.16 N for normal and shear forces. A VecTile calibrated while flat retains accuracy when curved, while a five-minute manual calibration is sufficient for practical use. Two applications demonstrate its utility. First, shear readings are sensitive enough to stop a sharp scalpel from puncturing a balloon after contact. Second, the sensor substantially improves Diffusion Policy-guided power-plug insertion. All designs and code will be released upon paper acceptance. Project website: https://jiannnh.github.io/VecTile/.

0.20

MagPillar: A Soft Magnetopillar Array Tactile Sensor for Robotic Surface Perception

cs.RO ·2026-11-01 ·Haotian Guo, Yu Feng, Hao Wu, Jiazhi Tang, Ningbin Zhang +1 more
similarity 0.54
Abstract

Robotic surface exploration benefits from tactile interfaces that accommodate contact and capture variations in surface characteristics. Herein, we report MagPillar, a tactile sensor inspired by spider tactile hairs that combines a magnetic pillar array with three-axis Hall sensing. A full-array mechanical and magnetic-field model characterizes how pillar deformation affects the superposed fields measured across the array, providing a physical basis for interpreting its contact responses. The compliant pillar architecture translates contact with surface textures and geometric features into distinct magnetic response patterns. Then, in robotic surface perception experiments, spectral features and logistic regression distinguish six material surfaces with an offline accuracy of 99.34% under within-session temporally blocked cross-validation. Continuous scans over periodic protrusions produce amplitude and peak-spacing variations consistent with changes in surface geometry. These findings connect compliant contact mechanics with distributed magnetic sensing, paving a new path for material recognition and qualitative surface-profile perception.

0.35

Tactile Reconstruction of Contact Task Frames and Forces for Hybrid Force/Motion Control

cs.RO ·2026-10-07 ·Antonio Rapuano, Simone Orelli, Barbara Bazzana, Antonio Franchi, Alessandro De Luca
similarity 0.53
Abstract · 14 pages, 9 figures, 7 tables. Video: https://youtube.com/playlist?list=PLejKMZmW8AvI. Dataset: https://doi.org/10.5281/zenodo.23209032

Hybrid force/motion control requires knowledge of the interaction force and of a task frame defining the force- and motion-controlled directions. These quantities are usually obtained from force/torque sensing or model-based residuals, often assuming also a nominal environment model. This work addresses the online estimation of the contact force and a possibly time-varying task frame using only soft optical tactile sensing, under the assumption of locally planar contact with a negligible contact moment. The proposed method maps a single image of the deformed elastomer of a soft optical tactile sensor to observable contact variables: indentation depth, two surface-to-sensor tilt angles, and 3D contact force, each with a per-sample uncertainty estimate. The mapping is learned through a self-labeling acquisition procedure, in which a manipulator imposes controlled contacts while an auxiliary Force/Torque sensor is used offline to provide ground-truth labels. The tactile measurement is then fused with robot proprioceptive data in an Extended Kalman Filter, producing a continuously updated estimate of the contact task frame and of the interaction force. Control experiments with a DigiTac sensor mounted on a UR10 manipulator demonstrate closed-loop contact force regulation against a flat rigid board in linear and angular motion by a human operator, with touch as the only exteroceptive feedback.