CS Paper Radar

Methanol substitution suppresses deflagration-excited knock and increases the efficiency of a hydrogen-fuelled CFR engine

Riming Xu, Mebin Panithasan, Xinyang Wang, Giovanni Vorraro, James W. G. Turner

eess.SY physics.chem-phmath-ph ·submitted 2026-11-12 19:20 UTC · v1
unusual

Abstract

Knock restricts the performance of hydrogen spark-ignition engines and is usually attributed to end-gas autoignition. To the authors' knowledge, this is the first study in which methanol is used to replace part of the hydrogen in a hydrogen engine at constant fuel energy addition, and it shows that near the knock boundary the limiting oscillation is excited by the deflagration itself, which methanol removes without derating the performance. Port-injected methanol replaced 20--50% of the hydrogen energy in a variable-compression Cooperative Fuel Research engine at 600 rpm and compression ratios of 8--12. With pure hydrogen, oscillation in the 4--15 kHz range began before 10% of the charge had burned in 97--100% of cycles, and its maximum amplitude (MAPO) followed the maximum pressure-rise rate across 2499 cycles (Spearman $ρ=0.94$). Methanol slowed the deflagration: it replaced high-flame-speed hydrogen, cooled the intake by 24--25 K and, at unchanged intake pressure, enleaned the mixture by 10--13%. At 50% methanol, the 10--90% combustion duration lengthened 2.7--3.0-fold, oscillation onset moved 4.5--8.3$^\circ$CA after CA10 and mean MAPO fell by 89--93% although the spark timing was advanced by 13--19$^\circ$CA, and IMEP and indicated thermal efficiency rose by 2.4--7.8%. Methanol was thus worth more than this advance, and at matched CA50 MAPO was still about 90% lower. The measured combustion duration of all 25 data sets scaled with the computed laminar flame speed as $S_L^{-0.58}$ ($R^2=0.99$); fuel replacement accounted for about three quarters of the reduction in $S_L$, and the end-gas autoignition integral stayed below 0.07, against 1 at autoignition. The chamber kept its cylindrical acoustic modes, whose frequencies fell by 8--9%. The trade-off is formaldehyde emissions, which rose five- to sixfold while NO$_x$ fell by 49--85%.

Comment
20 pages 8 figures

Closest papers

Nearest neighbours by meaning across the whole index.

Hydrogen-Diesel Dual-Fuel Engine Operation Using Real-Time GRU-Based Nonlinear Model Predictive Control

eess.SY ·2026-09-14 ·Alexander Winkler, Vasu Sharma, Julian Bedei, Edward Sperling, Charles Robert Koch +2 more
similarity 0.45
Abstract · Submitted to International Journal of Hydrogen Energy

Hydrogen-diesel dual-fuel (H2DF) combustion reduces combustion-out CO2 emissions but exhibits nonlinear cycle-to-cycle dynamics at high hydrogen energy shares (HES). This work evaluates nonlinear model predictive control (NMPC) with a gated recurrent-unit deep neural network dynamics model for transient H2DF control. Trained on 99,800 engine cycles, the model predicts indicated mean effective pressure, nitrogen oxides (NOx), particulate matter (PM), and maximum pressure-rise rate. Single-cylinder Cummins 4.5 L experiments follow an unseen 4,900-engine-cycle trajectory. Compared with production diesel-only control, NMPC improves load-tracking mean absolute error by 27.8% and reduces mean PM by 61.1%, while mean engine-out NOx increases by 105.1% without exhaust-gas recirculation. Mean and peak HES reach 39.7% and 55.1%; a high-hydrogen setting achieves 77.8% peak HES without constraint violations. Robust to feedback noise and model-plant mismatch and executing in 3 to 7 ms per engine cycle on low-cost embedded hardware, learned-dynamics NMPC enables practical, real-time, constraint-aware transient H2DF control with substantial diesel substitution.

0.45

Hydrogen in Practice: A Global Review of Demonstration Projects from Production to Integration

eess.SY ·2026-11-14 ·Yiyina Teng, Shahab Dehghan, Xiaoqiang Guo, Shiqi Zhang, Yanming Wan +2 more
published similarity 0.44
Abstract · 49 pages, 15 figures

Hydrogen technology has the potential to address various challenges related to integrating low- and zero-carbon energy sources, as well as achieving carbon neutrality. It provides valuable solutions for transitioning to net-zero emission energy systems on a global scale. The implementation of hydrogen production and integration demonstration projects has received significant attention around the world and strong support from governments, highlighting the crucial role of such initiatives in the advancement of hydrogen energy. However, research in this area remains limited, particularly in terms of comprehensive and systematic reviews of industrial practices under real-world conditions. To bridge this gap, this article provides an in-depth review of hydrogen production, storage, and industrial applications, summarizing key features of thirteen exemplary hydrogen demonstration projects from around the world. The goal is to offer insights and guidance for the large-scale deployment of hydrogen energy while identifying potential technological pathways for the future.

0.37

Deep Behaviour Cloning of Model Predictive Control for Real-Time Operation of a Hydrogen-Diesel Dual-Fuel Engine

eess.SY ·2026-09-27 ·Alexander Winkler, Neeraj Naduvath Mana, David Gordon, Jakob Andert
similarity 0.40
Abstract · Submitted to Control Engineering Practice

Hydrogen-diesel dual-fuel (H2DF) combustion engines offer a promising pathway for decarbonising hard-to-electrify transport sectors, yet their highly nonlinear dynamics and coupled process variables demand constraint-aware control strategies. Model Predictive Control (MPC) meets these requirements but requires an online optimisation in every combustion cycle, which limits deployment on low-cost embedded hardware. This paper trains a feedforward deep neural network (DNN) by behaviour cloning (BC) to imitate an MPC expert, using 86,000 engine cycles of demonstration data collected at 1500 min-1 on a modified Cummins QSB 4.5-litre hydrogen dual-fuel engine. Two variants, one with process feedback and one without, are validated experimentally. Both track unseen fast-transient load steps (3-8 bar indicated mean effective pressure, IMEP) with normalised root mean square error (NRMSE) values of 7.80% and 9.03% against the expert's 8.01%, while keeping mean NOx and particulate matter emissions at or below those of the expert. Inference takes 2 ms or less on a Raspberry Pi 400 (ARM Cortex-A72 at 2.2 GHz), including 1 ms communication latency, compared to up to 7 ms for the MPC expert, a 3.5x speedup. Open-loop profiling on a low-cost ESP32 microcontroller at 180 MHz gives 4.3 ms per inference, 4x faster than required for the 18 ms cycle window. Beyond the training range the cloned policy saturates its controls but exceeds the pressure-rise-rate limit. To the authors' knowledge, this is the first experimental BC controller for cycle-to-cycle combustion control of an internal combustion engine (ICE), trained from demonstrations recorded on the engine itself.

0.07

Coordinated Dynamic Operation of Integrated Electrolyzer-Compressor Systems

eess.SY ·2026-08-12 ·Amin Salehi, Janne Seppanen, Mahdi Pourakbari-Kasmaei
similarity 0.37
Abstract

The increasing interaction between power and hydrogen sectors highlights the importance of coordinated operation of electrolyzers and electric-driven compressor stations (EDCSs). This becomes particularly of higher importance under transient disturbances. However, coordinated dynamic interactions of these coupled subsystems remain largely unexplored. This article addresses such gap by developing a dynamic model for an integrated electrolyzer-EDCS system and designing appropriate PID control schemes to address the potential disturbances affecting either component. To this end, linearized models of the electrolyzer and EDCS are first derived to enable systematic controller design. Then, two PID controllers, representing conservative and fast-tracking designs, are developed to coordinate the system response. The developed coordinated model is examined and verified under four different cases. The results demonstrate the effectiveness of the proposed model under disturbances from the compressor driver or the electrolyzer. Controlling the electrolyzer flow in response to EDCS disturbances coordinates system dynamics and mitigates undesirable transient fluctuations. Conversely, under electrolyzer disturbances, regulating the EDCS torque eliminates inconsistent responses in pressure, flow, and rotational speed, while preventing hazardous transient undershoots and overshoots. Overall, the proposed framework guarantees transient stability and operational reliability of the integrated electrolyzer-EDCS system.

0.04

Low-Ripple Modulation Strategy for a Photovoltaic-Based Triple-Port Hydrogen Production System

eess.SY ·2026-09-12 ·Shiqi Zhang, Ziang Jiao, Jiaxin Su, Ning Wang, Zheng Li +2 more
top venue similarity 0.34
Abstract · 13 pages. Accepted manuscript

Among various production methods, hydrogen generation via electrolysis powered by renewable energy plays a key role in achieving large-scale green hydrogen production. The triple active bridge isolated DC-DC conversion system exhibits significant application potential in hydrogen production due to its advantages, such as high energy density, wide step-down ratio, and high reliability. However, the output current ripple at the hydrogen production port critically affects the efficiency of the electrolyzer and the hydrogen production rate. Existing studies have limited optimization effects on current ripple and struggle to achieve dynamic optimization, leading to constrained ripple suppression under dynamic operating conditions. To address this issue, this paper proposes a low-ripple modulation strategy based on coordinated optimization of inner and outer phase-shift angles for multi-port power conversion systems in renewable energy hydrogen production. By establishing an accurate mathematical model, the optimal phase-shift angle combination under minimal current ripple conditions is derived. An improved differential evolution algorithm with adaptive parameter strategy is employed to achieve global optimization under dynamic conditions. Simulation and experimental results demonstrate that the proposed strategy effectively suppresses current ripple, providing an efficient and reliable solution for hydrogen production from fluctuating renewable energy sources.

0.65

Power Management of Electrically Driven Centrifugal Compressors for Flexible Operation

eess.SY ·2026-11-13 ·Alp Albay, Tak Lam Fok, Niklaus Hung, Maiken Omtveit, Mehmet Mercangöz
unusual similarity 0.33
Abstract

We present a control strategy for power management of a variable-speed 15MW (rated power) centrifugal compressor, and investigate how quickly it can follow a reduced electrical power reference without entering surge. We use a Greitzer-Gravdahl type model scaled to industrial size with rate-limited valve actuators as a simulation environment and propose an advanced regulatory control structure using feedback control loops with dynamically scaled feedforward mechanisms and a structure of min/max selectors. In simulated experiments, a 6MW power reduction from varying initial operating points on a 12MW iso-power line is delivered at rates of up to 10MW/s, i.e.to 90% in 0.54s, without opening the recycle valve. Depending on the initial operating point, a large power reduction can be delivered at once or with a restricted ramp rate. The stroking rate of the discharge side valve is identified as the limiting factor for how fast the power can be reduced in the studied configuration. A limited sensitivity study on the impact of rotor inertia for power shedding performance is also provided.

0.25

Grid Integration of Gigawatt-Scale Hydrogen Hubs: A Multi-Timescale Stability Analysis and Connection Requirements for Weak Grid Environments

eess.SY ·2026-08-17 ·Mohamed Shamseldein
publishedcode/data similarity 0.32
Abstract

The global transition toward green hydrogen is driving the deployment of gigawatt-scale electrolysis centers, introducing a novel, converter-dominated load class to the bulk power system. Unlike conventional industrial loads, these facilities utilize extensive power electronics interfaces with fast dynamics comparable to Inverter-Based Resources (IBRs). This paper presents a comprehensive grid impact assessment of large-scale hydrogen hubs, focusing on harmonic injection, voltage stability in low Short Circuit Ratio (SCR) environments, and frequency response capabilities. Adopting a "full-spectrum" open-source modeling approach, the study utilizes PandaPower for large-scale steady-state contingency assessment; ANDES for electromechanical dynamic simulations to evaluate Fast Frequency Response (FFR); and ParaEMT for high-fidelity electromagnetic transient analysis of harmonic distortion and Low Voltage Ride-Through (LVRT). A critical finding of this study is that standard load models, including the generic PERC1 (data center) model, are insufficient for hydrogen hubs. The paper recommends specific structural modifications to the PERC1 model - specifically regarding process safety latches and restart voltage thresholds - to accurately capture the risk of prolonged plant tripping. Based on these findings, the paper proposes a set of standardized connection requirements to ensure secure integration.

0.57

Beyond Retraining-Free MoE Compression: A Cost-Normalized Study of Post-Compression Adjustment

cs.LG ·2026-09-05 ·Sieun Hyeon, Jaeyoung Do
top venueposition similarity 0.31
Abstract · Accepted to EMNLP 2026 (Main Conference)

Retraining-free MoE compression reduces deployment memory by pruning or merging experts, but often treats the compressed checkpoint as the final artifact. We argue that this view is incomplete: compressed MoE checkpoints are better understood as compressed initializations that benefit from a tiny post-compression adjustment stage. Across two MoE LLM backbones, four pruning/merging methods, three expert-retention ratios, and 28 benchmarks, we compare LM fine-tuning and teacher-based KD under matched small-data budgets and measured GPU costs. Using only 3,000 C4 examples and a single epoch of adjustment, Full FT recovers 37.3% of the original-to-compressed performance gap on average. Moreover, LM fine-tuning is more cost-effective than standard token-level KD, and full-parameter adjustment gives the strongest cost--recovery trade-off among the tested scopes. These results suggest that retraining-free compression should be paired with small post-compression adjustment to recover a substantial portion of the performance lost during compression.

0.54