CS Paper Radar

OKB-CFM: Observation-Keyed Barycentric Conditional Flow Matching for Unpaired Sparse-to-Dense Cardiac Shape Completion

Kangneng Zhou, Shuang Song, Yitian Zhao, Dian Song, Yujia Wang, Xinghua Zhang, Li Wang, Xi Li, Hao Dai, Feng Cao

cs.CV ·submitted 2026-11-21 06:19 UTC · v1

Abstract

Completing cardiac segmentations from sparse cine magnetic resonance labels is challenging because acquired planes do not uniquely determine the underlying anatomy and patient-matched dense annotations are rarely available. We propose observation-keyed barycentric conditional flow matching for completion between clinically unpaired cohorts. Independently trained variational autoencoders represent sparse observations and dense shapes. A fixed memory associates simulated sparse keys with their source dense encodings, enabling candidate retrieval within the sparse latent space. A matching network aggregates the retrieved values into a query-dependent barycentric endpoint, toward which an endpoint-conditioned flow transports the sparse encoding. Individual candidate values provide alternative completion endpoints. On 327 real unpaired inputs, the method obtains encoder-feature Fréchet and squared maximum mean discrepancy scores of 7.93 and 2.02 after scaling by 10,000 and 10,000,000, respectively, corresponding to reductions of 47.0\% and 94.2\% relative to contrastive unpaired translation. On a 34-file simulated test partition, evaluation against dense-VAE-reconstructed references yields a five-class mean Dice of 0.889, squared Chamfer distance of 6.15 square voxels, 95th-percentile surface distance of 3.88 voxels, and average symmetric surface distance of 1.50 voxels. These results characterize cohort-level feature agreement, observed-label consistency, and reconstruction under the stated reference construction. By complementing routine cine-based functional assessment with inferred multi-chamber anatomical context, this framework provides a basis for investigating how chamber morphology and spatial relationships relate to cardiac function.

Comment
10 pages, 8 figures

Closest papers

Nearest neighbours by meaning across the whole index.

Flow-based conditional cardiac anatomy generation for virtual cohorts

cs.LG cs.CVq-bio.QMq-bio.TO ·2026-08-10 ·Konstantinos Kevopoulos, Beatrice Moscoloni, Benjamin Alheit, Cameron Beeche, Julio A. Chirinos +2 more
similarity 0.68
Abstract

Cardiac digital twin research is moving from subject-specific anatomical replicas toward virtual cohorts that represent clinically relevant population subgroups. Yet access to representative imaging-derived anatomy datasets remains limited by cohort size, subgroup sparsity, and data-sharing constraints. Conditional generative models could help address this gap, but virtual cohorts are useful only if they preserve realistic, metadata-dependent anatomical variability. Existing cardiac anatomy generators largely rely on conditional variational autoencoders (cVAEs), which couple representation learning and metadata conditioning through a shared regularized latent prior. We introduce CAN-FLOW, a two-step Conditional ANatomy generation framework based on normalizing FLOWs that first learns geometry-only latent representations of diffeomorphic cardiac shape momenta and then models their sex-, age-, and body-mass-index-dependent distribution with a conditional normalizing flow. We trained CAN-FLOW on 2,208 healthy UK Biobank subjects and compared it with cVAEs across regularization strengths. CAN-FLOW generated plausible stochastic biventricular anatomies that better reproduced clinical phenotype distributions, metadata-dependent trends, subgroup variability, point-cloud coverage, and high-dimensional shape variability. Together, these results establish CAN-FLOW as a shareable framework for generating realistic, stochastically varying, metadata-conditioned biventricular anatomies for virtual cohort construction and in silico clinical trial workflows.

0.04

A Strong Linear Baseline for Whole-Heart Cardiac Shape Completion on CT, with an Open Eleven-Structure Statistical Shape Model

cs.AI ·2026-08-20 ·Matej Gazda, Jakub Gazda, Juraj Gazda, Peter Drotar
publishedbenchmark similarity 0.64
Abstract

Public cardiac cohorts annotate different subsets of the heart, so shapes from separate sources cannot be pooled without shared correspondence. Among released cardiac shape resources, none we identified carries the atrial appendage, pulmonary veins, and caval stumps as separate blocks in one mesh. Completion benchmarks also compare deep models against a least-squares projection onto shape modes, not the conditional estimator the same fitted model implies. We release an eleven- structure cardiac computed-tomography (CT) statistical shape model, built from 383 automatically labelled cases in 11 571-vertex correspondence, and compare completion estimators under one frozen internal split and endpoint. On a 76-case internal list held out from fitting, a closed-form conditional-Gaussian estimator reconstructed the missing non-chamber structures at 3.717 mm mean per-vertex error, averaged equally over one, three, five, and nine observed structures. A five-refit mask-conditioned graph variational autoencoder reached 5.248 mm and nearest-neighbour retrieval 8.931 mm. The paired difference was 1.531 mm (95% confidence interval 1.384 to 1.711), and the ordering held in a raw-coordinate sensitivity arm. Expert manual labels exist for 58 external CT cases, but our registered reference is close enough to score only five structures. There the closed-form estimator again had lower average surface distance, 95th-percentile Hausdorff distance, and Chamfer error for both completed atria. On a second public benchmark of 20 cases the reference was close enough for three of four completed structures, and the same ordering held there. Four structures have no expert reference. The released model and its completion operator support cohort-unification research on aligned CT, not clinical use.

0.34

Semantic Latent Alignment for Flow Matching with Invertible Bi-Lipschitz Adapters

cs.CV cs.LG ·2026-10-15 ·Felix Nützel, Mischa Dombrowski, Luca Hagen, Bernhard Kainz
similarity 0.63
Abstract · 17 pages, 5 figures

Pretrained latent spaces trade compression, reconstruction, and the learnability of the coordinates a downstream generator has to work in, which complicates adapting these spaces to different domains or tasks: continued training is expensive, and without a new alignment objective it often fails to improve downstream generation. We instead leave the encoder and decoder fixed and change only the coordinates between them, using an invertible bi-Lipschitz adapter aligned offline to a semantic teacher and frozen during class-conditional flow matching. Invertibility preserves compatibility with the pretrained autoencoder, while the bi-Lipschitz constraint limits how far alignment can distort its latent geometry. This provides a simple way to improve semantic organization while retaining the compression and reconstruction properties of the original latent space. On two medical imaging datasets, constrained latent adaptation improves feature metrics, seed stability and counterfactual edit strength, while remaining competitive on downstream classification. In contrast, unconstrained adaptation can become highly anisotropic and sensitive despite remaining invertible, highlighting the importance of controlling geometric distortion. Our results suggest that carefully constrained post-hoc adaptation offers a parameter-efficient and tuning-free alternative to jointly modifying the representation during generative training.

0.25

FM-Recon: Exploring Foundation Model Features for Accelerated Cardiac Cine MRI Reconstruction

cs.CV cs.AI ·2026-11-16 ·Donghang Lyu, Marius Staring, Ruochen Gao, Jochen Keupp, Hildo J. Lamb +1 more
similarity 0.62
Abstract

Foundation models have demonstrated strong feature extraction capabilities across various medical imaging tasks, yet their potential for MRI reconstruction remains largely unexplored, particularly within unrolled reconstruction networks and under artifact-corrupted inputs. In this work, we explore whether and how features from pretrained foundation models can benefit accelerated cardiac cine MRI reconstruction. To this end, we propose FM-Recon, a framework that refines and integrates extracted features from frozen image encoder of foundation models into an unrolled reconstruction network. Through extensive experiments on the CMRxRecon2023 dataset, we systematically evaluate foundation model features across different reconstruction settings. Our results show that foundation models can extract informative representations from artifact-corrupted inputs and improve reconstruction performance, particularly at moderate acceleration factors. These findings demonstrate the potential of foundation model features for accelerated MRI reconstruction and provide insights into their effective integration into unrolled reconstruction networks.

0.13

Metadata-Aware Adaptation of a Generative Foundation Model for Conditional CMR Synthesis

cs.CV cs.AI ·2026-08-25 ·Marc Rodríguez, Grzegorz Skorupko, Nay Aung, Steffen E Petersen, Karim Lekadir +1 more
code/data similarity 0.62
Abstract · 5 pages, 3 figures

Synthetic image generation is a promising strategy to address data scarcity and the underrepresentation of clinically important phenotypes in medical imaging, yet generating images that faithfully reflect meaningful patient characteristics remains challenging. In this work, we investigate metadata-conditioned cardiac magnetic resonance (CMR) synthesis using a pretrained latent diffusion model, encoding structured clinical metadata and slice position as textual prompts to guide CMR generation. To improve metadata adherence and address the imbalance of clinical attributes, we integrate three strategies: Metadata-Free Classifier-Free Guidance (CFG), Contrastive Batching, and Inverse-Frequency Sampling. The framework was fine-tuned and evaluated on 59,058 short-axis CMR from the UK Biobank using paired image similarity, distributional fidelity, and subgroup-level analyses. The combined approach achieved a Fréchet Inception Distance (FID) of 37.47, improving by 57.04\% over the same model fine-tuned without these strategies and by 28.68\% over a previous text-conditioned CMR diffusion baseline requiring cardiac geometry as additional input, while relying solely on patient metadata. This distributional gain, driven mainly by Metadata-Free CFG, came with a modest reduction in paired similarity, suggesting that the model prioritizes population-level realism over exact image reproduction. Subgroup analyses demonstrated improved alignment across demographic and acquisition-related metadata, with disease-specific conditioning being the most challenging task. These findings demonstrate the potential of generative foundation models for clinically meaningful CMR synthesis while highlighting the need for more effective metadata-aware conditioning strategies. Our code is available at https://github.com/rodriguezmarc/conditional-cmr.

0.42

GenStrain: Multi-Conditional Generative Diffusion Model To Synthesize High-quality Motion and Strain Maps From Cardiac Magnetic Resonance Images

eess.IV cs.LG ·2026-11-05 ·Rishov Paul, Sona Ghadimi, Cristiane C. Singulane, Amit R. Patel, Frederick H. Epstein +1 more
code/data similarity 0.62
Abstract

This paper presents GenStrain, a novel method for synthesizing high-quality cardiac motion-based strain maps from routinely collected cine cardiac magnetic resonance (CMR) images. Existing approaches typically rely on image registration to estimate motion (a sequence of displacements) from cine CMR images, but cine CMR presents very sparse trackable intramyocardial features, presenting challenges to estimate intramyocardial motion. An advanced imaging technique, Displacement Encoding with Stimulated Echoes (DENSE) CMR, is considered as the gold standard for strain assessment, but it requires additional acquisitions, which are not ideal for efficient clinical workflows. To address this gap, we introduce GenStrain, a novel framework designed to learn the data distribution of highly accurate cardiac motion captured by DENSE. In particular, we develop a diffusion process in motion space, where spatiotemporal continuity is carefully considered. To fully leverage both cine CMR images and their associated motion patterns, we introduce a multi-conditional conditioning strategy that integrates anatomical features and motion representations learned by a spatiotemporal registration model to guide the generation process. Experimental results demonstrate that our proposed model, GenStrain, outperforms existing strain analysis methods based on displacement estimates from both traditional registration approaches and state-of-the-art (SOTA) deep learning models. Our model represents a promising step toward more accurate cardiac function assessment and holds great potential for clinical translation. Our code is publicly available at https://github.com/Rishov-MIA/GenStrain.

0.14

Reading the Whole Heart: Latent-Attention Masked Autoencoders for Multimodal Cardiac Representation Learning

cs.AI ·2026-09-10 ·Andrea Agostini, Simon Böhi, Moritz Vandenhirtz, Samuel Ruiperez-Campillo, Max Krähenmann +5 more
similarity 0.61
Abstract

Cardiovascular diagnosis and treatment rest on integrating complementary modalities, such as electrocardiogram, echocardiography, and chest X-rays, each capturing distinct but complementary aspects of cardiac pathophysiology. Yet most medical foundation models remain modality-specific, combining modalities only for finetuning or post-training. This discards the cross-modal evidence clinicians naturally integrate and ignores the structure within each modality. We introduce Latent-Attention Masked Autoencoder (LAMAE), a multimodal, structure-aware masked autoencoder that jointly learns patient-level representations during self-supervised pretraining. Instead of fusing modalities post hoc, LAMAE exchanges information directly in the latent space through a shared latent-attention module operating over a study-view-entity hierarchy, enabling aggregation of variable observations and handling of missing modalities. Pretrained on over 500'000 MIMIC-IV hospital stays, LAMAE outperforms modality-specific pretraining and strong contrastive and vision-language baselines across multimodal hospital-stay tasks, such as in-hospital mortality, ICD-10 and DRG coding, and length of stay, while remaining competitive on unimodal tasks. Modeling this structure also pays off within a single modality: even without cross-modal information, the latent-attention module improves representations over modality-specific pretraining.

0.11

Anatomy-Aligned Surface Field Learning for Myocardial Reconstruction from Sparse Short-Axis Cine MRI

cs.CV ·2026-09-24 ·Xiaohan Yuan, Xuan Yang, Qingya Li, Yangang Wang, Lei Li
code/data similarity 0.61
Abstract · 12

Patient-specific 4D myocardial reconstruction from cine MRI supports quantitative functional assessment, regional motion analysis, and simulation-based modeling. However, routinely acquired short-axis (SAX) cine MRI is sparsely sampled along the through-plane direction, making dense and anatomically consistent surface reconstruction challenging. In this study, we propose an anatomy-aligned surface learning framework that parameterizes the epicardial and endocardial surfaces on a shared circumferential-longitudinal UV domain. This formulation converts irregular 3D reconstruction into structured coordinate-field completion with explicit correspondence across subjects and cardiac phases. Sparse SAX contours are encoded as UV observation fields, coverage-aware sampling improves robustness to incomplete slice coverage, and topology- and distortion-aware learning preserves circumferential continuity and local surface quality. Experiments on three public cine MRI datasets showed that the proposed method consistently outperformed representative mesh-based and implicit reconstruction approaches, achieving overall Chamfer distances of $2.887$~mm on ACDC, $2.641$~mm on M\&Ms, and $2.810$~mm on M\&Ms-2. The reconstructed sequences also preserved ventricular function, with end-diastolic volume and ejection fraction errors of $3.3$~mL and $1.1 \%$, respectively. These results demonstrate that anatomy-aligned UV learning provides an accurate, efficient, and correspondence-aware representation for sparse cine MRI reconstruction and myocardial modeling. The source code will be available at https://github.com/yuan-xiaohan/SAX2MyoSurf.

0.23