CS Paper Radar

HKD-ACPA: Heterogeneous Knowledge Distillation Adversarial Cyber-Physical Attacks in Power Grids

Junhao Ren, Honglin Gao, Shuo Feng, Kun Cao, Qiyu Kang, Xiaofeng Zong, Shuping He, Gaoxi Xiao

cs.LG ·submitted 2026-11-22 11:49 UTC · v1

Abstract

Learning-based algorithms assist power-grid control centers in localizing transmission-line attacks, yet existing adversarial attacks typically require white-box access or repeated online queries. We study a practical zero-query setting in which an adversary coordinates physical, denial-of-service (DoS), and false data injection (FDI) attacks using only local measurements and historical detector outputs. To bridge the input-view asymmetry between local adversarial observations and DoS-masked control-center measurements, we propose Heterogeneous Knowledge Distillation Adversarial Cyber-Physical Attacks (HKD-ACPA). HKD-ACPA distills historical detector predictions into a heterogeneous graph surrogate ensemble and trains a residual calibration module to correct the view-induced logit discrepancy. Over this calibrated surrogate, we formulate sparse, magnitude-bounded FDI synthesis with a group-balanced objective that jointly induces missed detections and false alarms, and solve the resulting hybrid discrete--continuous problem via bi-level projected gradient-based proximal policy optimization (PGPPO). Experiments on the IEEE 30-bus and 118-bus systems show that HKD-ACPA outperforms all surrogate-based baselines across every sparsity budget and surpasses online-query attacks in eight of ten system--budget settings without querying the detector model.

Comment
13 Pages, 2 Figures

Closest papers

Nearest neighbours by meaning across the whole index.

Stealthy, High-Impact False Data Injection Attacks in Smart Grid Using Physics-Constrained GAN with Limited System Knowledge

cs.LG eess.SY ·2026-11-11 ·Md. Mainul Islam, Hasan Kurban, Abdulrahman Takiddin, Muhammad Ismail, Rachad Atat +1 more
hot direction similarity 0.78
Abstract · 11 pages

False data injection (FDI) attacks can distort power system state estimation while retaining plausible measurement patterns. Existing FDI methods trade stealth for impact or vice versa. They often assume access to internal grids, all-bus sensing, or defender models. In this paper, we propose a detector-agnostic physics-constrained generative adversarial network (PCGAN) that learns decoupled power-flow sensitivities from historical measurements of deployed sensors. The learned active-power-angle and reactive-power-voltage-magnitude relationships guide perturbations restricted to compromised channels, while adversarial training promotes realistic spatiotemporal patterns. We implement PCGAN and seven existing FDI attacks on the IEEE 300-bus system using one year of observed hourly demand from PJM Interconnection, a regional transmission organization in the United States, and synthetic bus-level load profiles. We compare their performance across 10%, 30%, 60%, and 100% compromised sensors. Attack stealth is assessed against ten machine-learning (ML) detectors and conventional bad-data detection (BDD) methods, while physical impact is quantified through nonlinear alternating-current weighted least-squares state estimation. PCGAN achieves 84.28% mean ML evasion and 22.31% mean spatial load misperception across the four scenarios. Its mean stealth-impact trade-off score reaches 18.69%, compared with 5.61% for the strongest competing attack. PCGAN also achieves 83.45% chi-square BDD evasion and 86.02% largest-normalized-residual BDD evasion. These results demonstrate a favorable stealth-impact balance under varying sensor-access levels and provide challenging attack cases for evaluating FDI detectors.

0.21

Adversarially-Informed Node Criticality Identification in Power Grid Measurements

eess.SY math.OC ·2026-08-27 ·Koto Omiloli, Olugbenga Moses Anubi
similarity 0.72
Abstract

Power grid state estimation relies on sensor measurements that are increasingly vulnerable to adversarial corruption in cyberphysical environments, potentially leading to significant deviations in system observations. This motivates the need to identify critical measurement nodes whose compromise results in the most severe system-level impact. However, existing node criticality methods primarily rely on structural or steady-state analyses and do not explicitly account for adversarial effects on system behavior. To address this gap, this paper proposes an adversarially informed framework for identifying critical measurement nodes in linearized power systems. Within this framework, a structured attack generation mechanism is developed to construct stealthy and effective false data injection attacks (FDIAs) against an H-infinity resilient state estimator. Node criticality is then evaluated using coalition-based marginal contributions of compromised sensor subsets, estimated via permutation sampling over a prescribed set of admissible nodes, with the resulting importance scores mapped to the corresponding physical buses. Simulation results on the IEEE 14-bus system show that adversarially identified nodes induce larger deviations in frequency, voltage angle, and net power compared to randomly selected nodes, demonstrating the effectiveness of the proposed framework.

0.23

Interpretable Cyber-Physical Attack Detection in Smart Grids: A Leakage-Controlled Multi-Testbed Evaluation of Fusion, Robustness, and Observability Limits

cs.LG cs.AIcs.CR ·2026-11-07 ·Muhammad Ridwanul Hoque, Sarah Sharif, Reza Saeed Kandezy, Yaser Banad
code/data similarity 0.67
Abstract

Cyber-physical smart-grid detectors are typically treated as black boxes and validated exclusively on clean, temporally shuffled datasets, which risk overly optimistic performance claims. This work presents a multi-testbed evaluation study built around an interpretable, time-windowed fusion Random Forest, adopting the pessimistic result whenever evaluation protocols disagree. (i) On a public paired cyber-physical dataset, shuffled cross-validation is optimistic: macro-F1 falls from 0.96 to 0.88 +/- 0.06 under rolling-origin temporal evaluation. A topology-free graph convolutional network (GCN) serving as a control confirms that this lightweight model is competitive on these splits. (ii) The adaptive and adaptive-joint feature-space attacks, which are infeasible as realistic grid manipulations, degrade macro-F1 to 0.67 and 0.34, respectively. Adversarial training and randomized smoothing partially restore performance, and a physics-constrained evolution-strategy evasion on the IEEE 14-Bus testbed shows the same vulnerability pattern. (iii) On real IEC-104 traffic, the cyber view reliably catches structural attacks (recall of 0.87 to 0.98) but largely fails on semantic value manipulation (recall of 0.11 to 0.35). An observability taxonomy on the IEEE 14-Bus system reveals that stealthy false data injection defeats all three observation views. (iv) On a full AC weighted least-squares state-estimation testbed, a forecasting-aided temporal test is evaded by slow ramps precisely where a rate-invariant physics-manifold test sustains detection at a common 5% false-alarm target. A full end-to-end evaluation on IEEE 118-Bus confirms the ordering but bounds its strength: the manifold test detects every trial down to 0.05 degree/step and 0.48 at 0.02 degree/step, against 0.14 for the temporal test. All code and benchmarks are released.

0.34

Adversarial Robustness Is Not Zero-Day Generalization: A Controlled Evaluation of Flow-Based Intrusion Detectors on Corrected CIC-IDS2017

cs.CR cs.LG ·2026-10-31 ·Abdulhamid Zaro
code/data similarity 0.66
Abstract · 10 pages, 10 tables. Code and per-seed results: https://github.com/abdulhamid-zaro/robustness-vs-zeroday-nids

Synthetic variants of known attacks, including feature-space adversarial perturbations, are sometimes used as stand-ins for unseen ("zero-day") attacks when evaluating machine-learning network intrusion detection systems (NIDS). We test whether this proxy holds. On the corrected CIC-IDS2017 release we train Random Forest, XGBoost, a 1D-CNN and an FT-Transformer and compare, at a fixed 1% false-positive rate over five seeds, detection under constrained perturbations of known attacks (gradient-based and black-box attacks on 42 attacker-controllable features) with leave-one-attack-family-out (LOAO) detection, where an entire family is absent from training. Detection under the strongest perturbation we tested, with budgets of at most 0.2, stays between 90.9% and 99.7%, yet mean detection of held-out families falls to 76.2% (RF), 40.2% (XGBoost), 25.8% (1D-CNN) and 22.8% (FT-Transformer). Robustness exceeds LOAO detection for every model (gaps of 24 to 72 percentage points, 23 to 66 when robustness is also averaged over families; Holm-adjusted p $\le$ 0.00096), and the two measures agree at most on a coarse ranking of the models. An exact mixed-integer evasion search confirms the tree ensembles' scores. Benign-only anomaly detectors and a simple multi-class open-set baseline do not close the gap. A temporal split on 5 seeds (3 of the 4 models) leaves the gap in place. On CSE-CIC-IDS2018 the gap recurs for every model (16 to 68 points). On these benchmarks and under this threat model, a robustness score should not be read as a zero-day score, and the two should be reported separately. Code and per-seed results are publicly available.

0.40

A Defense-Aware Explainable AI Framework for Feature-Level Vulnerability Analysis in Optimal Power Flow

cs.CR ·2026-10-28 ·S. M. Monzurul Hoque Chowdhury, Qinghua Li, Jianhui Wang
similarity 0.66
Abstract

Optimal power flow (OPF) is a foundational analysis in power system operation, and inaccuracies in OPF decision-making can result in significant operational and security consequences. With the increasing adoption of machine-learning-based OPF surrogate models for real-time and large-scale applications, power system operation has become more susceptible to cyber threats, including data manipulation and false data injection attacks. Explainable artificial intelligence (XAI), particularly Shapley value-based approaches, has been employed to quantify the influence of input features on OPF outputs. Features exhibiting high influence are commonly interpreted as vulnerable. However, this interpretation neglects the role of attack detection mechanisms in the system, which typically monitor input-to-input relationships to detect anomalous behavior. Consequently, highly influential features may be readily detectable and may not represent the most vulnerable attack surfaces. To address this limitation, we propose a defense-aware explainable AI framework that explicitly incorporates attack detectability alongside operational impact. The framework integrates an OPF surrogate model representing input-to-output dependencies with a vanilla autoencoder representing input-to-input dependencies. Shapley-based explainability is applied to both models to construct a feature-level vulnerability metric. Empirical evaluation on IEEE test systems demonstrates that the proposed framework more accurately identifies security-relevant vulnerabilities than conventional OPF-surrogate-model-only explainability approaches.

0.11

Diversifying Moving Target Defense Against Adaptive Attacks Through Factorized Diffusion

eess.SY ·2026-10-16 ·Chenhan Xiao, Yang Weng
similarity 0.65
Abstract · 10 pages, 5 figures

Proactive defense offers a means to enhance power-system cybersecurity through controlled modifications of system configurations. One example is moving target defense (MTD), which uses distributed flexible AC transmission system (D-FACTS) devices to perturb transmission-line reactances against stealthy false data injection attacks. Existing MTD methods primarily rely on deterministic optimization, producing a single perturbation plan for each operating condition. However, repeated or highly correlated plans may expose predictable system configurations that attackers can learn and exploit. To address this limitation, this paper reformulates MTD as a conditional generative problem that produces diverse, secure, and physically feasible perturbation candidates. Learning such a distribution is challenging because MTD decisions jointly involve selecting branches, determining perturbation magnitudes, and coordinating adjustments across the network. To make this problem tractable, we factorize the decision distribution into three sequential conditional stages: branch selection, magnitude allocation, and continuous refinement. Graph-conditioned diffusion models are employed to capture the discrete and continuous decisions while accounting for network dependencies. Furthermore, a - objective is incorporated into diffusion training to favor candidates with desirable defense effectiveness and operational costs. Numerical studies on the IEEE 118- and 300-bus systems show that the proposed framework achieves AC feasibility comparable to that of optimization-based MTD baselines and higher - values, while reducing online computation time by an order of magnitude. The generated candidate pool remains effective under changing operating conditions and device availability, providing diverse high-value alternatives for flexible online cyber defense.

0.19

FedGuard-DC: Privacy-Preserving Federated Load Forecasting and Cyber-Attack Detection for Data-Center Loads in Transmission Systems

cs.CR ·2026-08-19 ·Md Kibria Saroare, Md Rubel Ahmed
published similarity 0.64
Abstract · Accepted on North American Power Symposium (NAPS) 2026

The rapid growth of large data-center (DC) loads is creating new challenges for power-system visibility, privacy, and cyber-physical security. System operators need accurate short-term information about these fast-varying loads, while DC operators may avoid sharing raw megawatt measurements because they can reveal sensitive workload and utilization patterns. This paper presents FedGuard-DC, a federated learning (FL) framework for privacy-preserving DC load forecasting and local false-data-injection attack (FDIA) detection. Each DC trains a dual-head model on its own measurements, where a shared encoder supports both a forecasting head and a reconstruction head. A calibrated anomaly score combines forecast residual and reconstruction error to detect corrupted measurements locally. Raw measurements and absolute MW demand remain at each DC, while only model updates, normalized forecast outputs, and scalar attack flags are shared with the global controller. Optional differential privacy and robust trimmed-mean aggregation are included to evaluate privacy-utility behavior and poisoned-client resilience. The framework is validated using phasor-domain simulation data from four large DC loads rated between 150 and 350 MW integrated into the IEEE 39-bus New England system. Results show a 0.5 s-ahead normalized forecast RMSE of 0.023-0.038 pu, compared with 0.32-0.34 pu for persistence. FedGuard-DC detects FDIA with ROC-AUC of 0.979, F1 = 0.930, and precision of 0.988, while robust aggregation reduces the poisoned-client RMSE impact from 0.042 to 0.035 pu.

0.25

Learning Defensive Policies against Diverse Inference Attacks for Smart Meter Privacy

cs.LG ·2026-09-21 ·Ruichang Zhang, Mustafa A. Mustafa
similarity 0.64
Abstract

Smart meter (SM) data provides fine-grained visibility into household energy consumption, but also exposes users to privacy risks. Inference attacks, known as non-intrusive load monitoring (NILM), can perform appliance-level inference from aggregate signals and recover sensitive behavioral patterns. In practice, attacker models are unknown and heterogeneous, making robust defense challenging. We formulate SM privacy protection as a black-box inference defense problem, aiming to reduce the recoverability of appliance-level information while generalizing across diverse and unseen attackers. We propose a proxy-guided hierarchical reinforcement learning framework that learns battery-based load-shaping policies to inject realistic but misleading appliance-level signatures into the aggregate signal, thereby disrupting the structured patterns exploited by NILM. A self-supervised aggregate-structure privacy probe provides a reconstruction-error-based surrogate reward for disrupting recoverable load structure, while a signature library makes the perturbations appliance-relevant and physically realizable through battery control. We provide theoretical rationale showing that proxy-guided optimization improves inference robustness under attacker diversity. Experiments on real-world datasets UK-DALE and REDD demonstrate strong cross-model and cross-appliance generalization. Across six unseen NILM attackers, covering four appliances on UK-DALE and five on REDD, our proposed defense increases average appliance-level RMSE by 107% and 166%, respectively, while reducing F1 score by 79% and 80%.

0.16