Abstract

Automated electrocardiogram (ECG) interpretation has advanced substantially with deep learning, yet many methods remain task-specific and label-dependent. Large language models (LLMs) and time-series foundation models (TSFMs) offer complementary pretrained representations, but integrating them is challenging because of mismatched feature spaces and the lead- and scale-dependent structure of ECG signals. We propose LAF-ECG (Lead-Aware Foundation Fusion for ECG), a dual-foundation framework that extends MedTsLLM with a lead-aware interface to a frozen TSFM backbone while retaining its reprogramming pathway. The proposed framework captures multi-resolution temporal context, fuses temporal and language-aligned ECG representations through adaptive residual integration, and employs branch-specific supervision with cross-branch alignment. LAF-ECG achieves 71.10% accuracy and 62.43% macro-F1 on PTB-XL, and 89.73% accuracy and 65.94% macro-F1 on Chapman-Shaoxing, outperforming MedTsLLM on both datasets. These results highlight the value of preserving lead-specific temporal structure when combining temporal and language foundation representations for ECG classification. The code is publicly available at https://github.com/kkianamm/LAF-ECG.

Closest papers

Nearest neighbours by meaning across the whole index.

MedTimeQ: Query-guided fusion of time-series foundation models and LLMs for multi-lead ECG classification

eess.SP ·2026-11-22 ·Kiana Taktehrani, Maryam Hosseini, Arash Mohammadi
code/data similarity 0.81
Abstract

Accurate classification of medical time series, such as electrocardiograms (ECGs), requires capturing waveform morphology, long-range temporal structure, inter-lead dependencies, and clinical semantics. Existing large language model (LLM)-based approaches often map signal patches directly into the language embedding space, potentially underusing pretrained time-series knowledge and transferring redundant or irrelevant information. We propose MedTimeQ, a parameter-efficient framework that integrates a lead-aware temporal foundation encoder with an LLM-reprogrammed ECG pathway through gated residual fusion. A Query Former uses learned diagnostic queries to select and compress fused representations into informative soft tokens for a frozen LLM. Semantic prototype learning further guides classification through multiple clinical descriptions per category, statistics-based prompt selection, and knowledge distillation. Both foundation backbones remain frozen, limiting training to lightweight interface and classification components. We evaluate MedTimeQ on PTB-XL, Chapman-Shaoxing, and MIT-BIH for recording-level diagnosis, rhythm classification, and heartbeat classification, respectively. MedTimeQ achieves the best performance in 11 of 12 dataset-metric comparisons, with consistent class-balanced gains across all three tasks. On PTB-XL, it achieves 76.93% accuracy and 58.14% macro-F1, exceeding MedTsLLM by 10.08 and 7.07 percentage points, respectively. These results demonstrate the benefits of selectively integrating pretrained temporal representations with clinical language semantics. Code: https://github.com/kkianamm/MedTimeQ

0.24

A Hybrid CNN--State-Space--Attention Backbone with Joint-Embedding Predictive Pretraining for 12-Lead ECG Classification

cs.CV ·2026-09-24 ·Yakoub Bazi, Sarah Aljuhani, Mohamad M. Al Rahhal, Mansour Zuair, Naif Alajlan
code/data similarity 0.75
Abstract

Automatic 12-lead electrocardiogram (ECG) classification requires representations that jointly capture local waveform morphology, long-range temporal dynamics, and cross-lead dependencies, yet integrating these properties within a single efficient architecture remains challenging. This paper introduces a hybrid CNN-SSM-Attention backbone for 12-lead ECG classification. A convolutional stem performs early waveform tokenization and temporal reduction, mixed state-space and depthwise-convolutional blocks model temporal dynamics and local morphology, and a late self-attention stage enables global token interaction at reduced resolution. To improve transfer from unlabeled data, we further develop an ECG-oriented Joint-Embedding Predictive Pretraining (JEPA) framework. Unlike ViT-based JEPA methods that mask patch tokens before the encoder, the proposed method samples span masks at the latent temporal resolution and projects them back to the waveform domain, then predicts clean latent targets from a momentum encoder without waveform reconstruction. Experiments on CPSC2018, Chapman-Shaoxing, and PTB-XL, with pretraining on approximately 350K unlabeled CODE-15 recordings, show that the proposed backbone provides strong supervised baselines under a compact parameter budget. JEPA pretraining further improves transfer, particularly in reduced-label settings and under both full fine-tuning and LoRA-based adaptation. Code: https://github.com/yakoubbazi/Hybrid_ECG_Jepa

0.26

PACE-ECG: Patient-Aware Contrastive ECG Pretraining; Leveraging Longitudinal Structure for Transferable Representations

cs.AI ·2026-11-09 ·Riccardo Cavarra, Lupo Lovatelli, Shaheim Ogbomo-Harmitt, Jakub Grzelak, Adelaide De Vecchi +2 more
similarity 0.73
Abstract

Foundation models for physiological signals are commonly evaluated on in-domain interpretation tasks, but their ability to transfer to longitudinal clinical prognosis across healthcare systems remains uncertain. We developed PACE-ECG, an ECG pretraining framework that combines contrastive learning across temporally neighbouring recordings from the same patient with clinically guided multitask supervision. We evaluated frozen ECG representations for post-myocardial-infarction all-cause mortality and incident heart failure prediction across MIMIC-IV and two external HEEDB cohorts, comparing the proposed representation with DeepECG-SSL, a state-of-the-art model, and two control baselines. Across both downstream tasks, the proposed model outperformed DeepECG-SSL in-domain (AUROC +1.9% for mortality and +4.0% for heart failure) and on external populations in HEEDB-Boston (+5.6% for mortality +10.3% for heart failure) and HEEDB-Atlanta (+6.9% for mortality +11.0% for heart failure) while using an encoder 41 times smaller and a fraction of the pretraining data. A matched ablation showed that patient-temporal pairing improved external mortality and heart failure AUROC over generic self-supervision by 7.0% and 9.4% on HEEDB-Boston and 8.9% and 9.3% on HEEDB-Atlanta. These findings indicate that pretraining-objective design greatly influences downstream transfer alongside model and data scale, and that in-domain performance alone is insufficient to establish the clinical generalisability of ECG foundation representations.

0.17

MS-ECG-FM: Towards a More Universal Electrocardiogram Foundation Model for Health Monitoring using Multi-source Contrastive Learning

cs.LG ·2026-10-06 ·Robert A. Lewis, I-Min Chiu, Kyle Verrier, Karthik Jayaraman Raghuram, Francoise Marvel +5 more
similarity 0.73
Abstract · Andrew C. Miller, Joseph Futoma: equal contribution. 52 pages, 4 figures, 20 tables, including supplementary information

Electrocardiography (ECG) records the electrical activity of the heart, aiding diagnosis by detecting abnormalities in cardiac function. ECG foundation models have demonstrated promising results, but are limited by a reliance on ECG interpretation reports as their sole supervision. Because interpretation reports only capture the subset of waveform information routinely recognized by clinicians, this constrains representation learning to overlook the broader diagnostic signals present in ECG. We introduce a new ECG foundation model --- MS-ECG-FM --- that is trained through contrastive alignment to multiple distinct clinical note types, including ECG, echocardiography, radiology, and discharge reports. We evaluate MS-ECG-FM on an extended set of ECG detection benchmarks, showing that it comprehensively outperforms existing methods on the full span of conditions that ECG can detect, including in reduced-lead configurations. Different reports improve representations for different diagnostic domains, while multi-source alignment captures their complementary information and produces consistently strong representations across clinically diverse tasks.

0.32

HEART: Hierarchical Expert Adaptive Refinement Transformer for ECG Representation Learning

cs.LG cs.AI ·2026-11-23 ·Junho Song, Jong-Hwan Jang, Joon-Myoung Kwon, Yong-Yeon Jo
similarity 0.72
Abstract

Learning robust representations from electrocardiograms (ECGs) is challenging because repeated cardiac cycles coexist with subtle and sparse diagnostic cues in local morphology and rhythm-level context. Existing ECG foundation models commonly rely on Transformerbased patch encoders with uniformly shared dense refinement pathways, limiting adaptive processing across heterogeneous ECG tokens. We propose HEART (Hierarchical Expert Adaptive Refinement Transformer), an ECG foundation model that introduces stage-specific conditional expert refinement during self-supervised pre-training. HEART places a local-level MoE over patch-level representations before temporal contextualization and a global-level MoE over context-integrated token representations after self-attention. Token-level Top-1 routing allows different patches or contextual tokens within the same ECG to follow different expert pathways. On public ECG benchmarks, HEART achieves strong performance under both linear probing and fine-tuning, with particularly large frozen-encoder gains on PTB-XL Form and Rhythm (+6.76 AUROC points each over the strongest protocol-reproduced baseline). Routing analyses provide qualitative evidence of complementary local and global expert specialization. We release our code and pretrained models at https://anonymous.4open.science/r/HEART-5E9F.

0.17

Holtercare-Bench: A Multimodal Benchmark for Evaluating Long-Term Dynamic ECG Analysis

cs.LG ·2026-08-19 ·Yihan Xie, Hanwen Cui, Runze Ye, Juekai Lin, Haoyang Wang +6 more
top venuebenchmarkcode/data similarity 0.71
Abstract

While multimodal large language models (MLLMs) excel in medical applications, most of them favor static images or short-term signals. In the critical field of dynamic electrocardiograms (ECG), models struggle with complex temporal reasoning and diagnostic report generation due to a lack of high-quality datasets and benchmarks. To address this, we introduce (i) Holtercare-23K, a large-scale multimodal dynamic ECG dataset comprising 22,980 QA pairs derived from 788 clinical Holter records and featuring a novel signal-video-text tri-modal alignment. Based on this dataset, we present (ii) Holtercare-Bench, a multimodal benchmark that evaluates models on temporal localization, clinical diagnosis, and global summarization. Zero-shot evaluations of leading MLLMs reveal a significant performance gap in processing ultra-long pathological sequences. However, fine-tuning representative models yields substantial improvements. This work illuminates the limitations of current MLLMs in electrophysiology and provides a foundational benchmark for long-term medical MLLMs. Our project is available at https://github.com/ZJU4HealthCare/Holtercare-Bench.

0.47

IECG: Weakly-Supervised Interpretability-Enhancing Foundation Model for Electrocardiogram

cs.AI ·2026-10-20 ·Huynh Dang Nguyen, Trong-Thang Pham, Anh-Thuan Do, Phuong-Nhi Dinh, Brijesh Patel +2 more
published similarity 0.70
Abstract · Accepted in WACV 2027

Electrocardiography (ECG) is a cornerstone of cardiac diagnosis, yet most machine learning methods for ECG analysis lack interpretability, limiting their clinical adoption. We present IECG, a weakly-supervised ECG foundation model that jointly performs diagnostic classification and abnormality localization without requiring manual abnormal region annotations, overcoming a long-standing bottleneck in interpretable ECG learning. Central to IECG is a weakly-supervised attention strategy that explicitly incorporates clinical priors by deriving abnormality heatmap pseudo-labels from established ECG clinical knowledge. These pseudo-labels guide the model's CLS-token attention through a KL-divergence loss, encouraging it to focus on diagnostically relevant waveform regions. During pretraining, IECG is jointly optimized with clinically guided attention supervision, ECG-text contrastive alignment, and report captioning objectives, enabling it to learn rich multimodal representations while producing localized waveform evidence. By explicitly aggregating features from clinically guided attention regions, IECG grounds its diagnostic predictions in interpretable waveform evidence without sacrificing classification performance. Extensive experiments demonstrate that IECG achieves state-of-the-art abnormal region localization while maintaining strong classification performance, advancing trustworthy foundation models for ECG analysis.

0.31

The Impact of Temporal Context Length and Encoding Strategies on Self-Supervised ECG Representation Learning

cs.LG eess.SP ·2026-08-13 ·Ahmed Sameh, Ramzi Al-Sharawi, Yogatheesan Varatharajah
publishedcode/data similarity 0.69
Abstract · Accepted at the 48th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC 2026). 6 pages, 2 figures…

Self-supervised electrocardiogram (ECG) models are often trained on a few seconds of ECG signal and, increasingly, on discretized token sequences. It remains unclear whether these choices sacrifice information needed for rhythm inference and longitudinal consistency in real-world ambulatory recordings. We present a controlled study on the Icentia11k single-lead dataset that varies (i) the input horizon (16 seconds, 1 minute, 5 minutes, and 10 minutes) and (ii) the front-end representation (continuous convolutional patch embeddings vs. fixed vector-quantized tokens), while holding the Transformer backbone and training protocol constant. Representations are assessed by downstream abnormal rhythm detection and by patient-level retrieval that probes cross-session stability. Our results show that increasing temporal context beyond 16-second snapshots yields stronger transfer and higher retrieval accuracy, with the strongest performance achieved by the 5- and 10-minute models, indicating improved capture of slow-varying rhythm dynamics and individual-specific structure. Across all evaluated horizons, continuous patch embeddings outperform discretized tokens, suggesting that quantization can discard clinically relevant waveform detail. These findings motivate ECG foundation models that emphasize extended context and continuous encoders for clinical prediction and similarity-based applications. Our code and pretrained models are publicly available at https://github.com/muha-0/ecg-ssl-representation-learning.

0.41