CS Paper Radar

HEART: Hierarchical Expert Adaptive Refinement Transformer for ECG Representation Learning

Junho Song, Jong-Hwan Jang, Joon-Myoung Kwon, Yong-Yeon Jo

cs.LG cs.AI ·submitted 2026-11-23 08:50 UTC · v1

Abstract

Learning robust representations from electrocardiograms (ECGs) is challenging because repeated cardiac cycles coexist with subtle and sparse diagnostic cues in local morphology and rhythm-level context. Existing ECG foundation models commonly rely on Transformerbased patch encoders with uniformly shared dense refinement pathways, limiting adaptive processing across heterogeneous ECG tokens. We propose HEART (Hierarchical Expert Adaptive Refinement Transformer), an ECG foundation model that introduces stage-specific conditional expert refinement during self-supervised pre-training. HEART places a local-level MoE over patch-level representations before temporal contextualization and a global-level MoE over context-integrated token representations after self-attention. Token-level Top-1 routing allows different patches or contextual tokens within the same ECG to follow different expert pathways. On public ECG benchmarks, HEART achieves strong performance under both linear probing and fine-tuning, with particularly large frozen-encoder gains on PTB-XL Form and Rhythm (+6.76 AUROC points each over the strongest protocol-reproduced baseline). Routing analyses provide qualitative evidence of complementary local and global expert specialization. We release our code and pretrained models at https://anonymous.4open.science/r/HEART-5E9F.

Closest papers

Nearest neighbours by meaning across the whole index.

The Impact of Temporal Context Length and Encoding Strategies on Self-Supervised ECG Representation Learning

cs.LG eess.SP ·2026-08-13 ·Ahmed Sameh, Ramzi Al-Sharawi, Yogatheesan Varatharajah
publishedcode/data similarity 0.76
Abstract · Accepted at the 48th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC 2026). 6 pages, 2 figures…

Self-supervised electrocardiogram (ECG) models are often trained on a few seconds of ECG signal and, increasingly, on discretized token sequences. It remains unclear whether these choices sacrifice information needed for rhythm inference and longitudinal consistency in real-world ambulatory recordings. We present a controlled study on the Icentia11k single-lead dataset that varies (i) the input horizon (16 seconds, 1 minute, 5 minutes, and 10 minutes) and (ii) the front-end representation (continuous convolutional patch embeddings vs. fixed vector-quantized tokens), while holding the Transformer backbone and training protocol constant. Representations are assessed by downstream abnormal rhythm detection and by patient-level retrieval that probes cross-session stability. Our results show that increasing temporal context beyond 16-second snapshots yields stronger transfer and higher retrieval accuracy, with the strongest performance achieved by the 5- and 10-minute models, indicating improved capture of slow-varying rhythm dynamics and individual-specific structure. Across all evaluated horizons, continuous patch embeddings outperform discretized tokens, suggesting that quantization can discard clinically relevant waveform detail. These findings motivate ECG foundation models that emphasize extended context and continuous encoders for clinical prediction and similarity-based applications. Our code and pretrained models are publicly available at https://github.com/muha-0/ecg-ssl-representation-learning.

0.41

PACE-ECG: Patient-Aware Contrastive ECG Pretraining; Leveraging Longitudinal Structure for Transferable Representations

cs.AI ·2026-11-09 ·Riccardo Cavarra, Lupo Lovatelli, Shaheim Ogbomo-Harmitt, Jakub Grzelak, Adelaide De Vecchi +2 more
similarity 0.76
Abstract

Foundation models for physiological signals are commonly evaluated on in-domain interpretation tasks, but their ability to transfer to longitudinal clinical prognosis across healthcare systems remains uncertain. We developed PACE-ECG, an ECG pretraining framework that combines contrastive learning across temporally neighbouring recordings from the same patient with clinically guided multitask supervision. We evaluated frozen ECG representations for post-myocardial-infarction all-cause mortality and incident heart failure prediction across MIMIC-IV and two external HEEDB cohorts, comparing the proposed representation with DeepECG-SSL, a state-of-the-art model, and two control baselines. Across both downstream tasks, the proposed model outperformed DeepECG-SSL in-domain (AUROC +1.9% for mortality and +4.0% for heart failure) and on external populations in HEEDB-Boston (+5.6% for mortality +10.3% for heart failure) and HEEDB-Atlanta (+6.9% for mortality +11.0% for heart failure) while using an encoder 41 times smaller and a fraction of the pretraining data. A matched ablation showed that patient-temporal pairing improved external mortality and heart failure AUROC over generic self-supervision by 7.0% and 9.4% on HEEDB-Boston and 8.9% and 9.3% on HEEDB-Atlanta. These findings indicate that pretraining-objective design greatly influences downstream transfer alongside model and data scale, and that in-domain performance alone is insufficient to establish the clinical generalisability of ECG foundation representations.

0.17

On the role of the tokenizer in ECG transformer models

cs.LG cs.AI ·2026-09-14 ·Jiawei Li, Fabio Bonassi, Johan Sundström, Thomas B. Schön, Antônio H. Ribeiro
code/datahot direction similarity 0.74
Abstract

Tokenization determines both the physiological content presented to an ECG Transformer and the sequence over which attention operates. We compare eight tokenization strategies across Transformer, Informer, Reformer, and FEDformer on the nine-label CPSC2018 classification task. The input projection and principal backbone capacity are controlled to isolate the effect of token construction. Median-beat and HeartLang tokenization achieve mean macro-AUCs of 0.893 and 0.889 across the four backbones, compared with 0.822 and 0.824 for point-wise and patch-wise tokenization. Pooling the two physiology-aware representations yields an 8.2% relative improvement in macro-AUC. They also reduce mean sequence length from 1,250 to 158 tokens and mean peak training memory from 5.21 to 0.27 GB. The results show that aligning tokens with ECG morphology can improve both predictive performance and memory efficiency without increasing backbone capacity. The source code is available on https://github.com/LeeJarvis996/ecg_tokenizer.

0.35

A Hybrid CNN--State-Space--Attention Backbone with Joint-Embedding Predictive Pretraining for 12-Lead ECG Classification

cs.CV ·2026-09-24 ·Yakoub Bazi, Sarah Aljuhani, Mohamad M. Al Rahhal, Mansour Zuair, Naif Alajlan
code/data similarity 0.72
Abstract

Automatic 12-lead electrocardiogram (ECG) classification requires representations that jointly capture local waveform morphology, long-range temporal dynamics, and cross-lead dependencies, yet integrating these properties within a single efficient architecture remains challenging. This paper introduces a hybrid CNN-SSM-Attention backbone for 12-lead ECG classification. A convolutional stem performs early waveform tokenization and temporal reduction, mixed state-space and depthwise-convolutional blocks model temporal dynamics and local morphology, and a late self-attention stage enables global token interaction at reduced resolution. To improve transfer from unlabeled data, we further develop an ECG-oriented Joint-Embedding Predictive Pretraining (JEPA) framework. Unlike ViT-based JEPA methods that mask patch tokens before the encoder, the proposed method samples span masks at the latent temporal resolution and projects them back to the waveform domain, then predicts clean latent targets from a momentum encoder without waveform reconstruction. Experiments on CPSC2018, Chapman-Shaoxing, and PTB-XL, with pretraining on approximately 350K unlabeled CODE-15 recordings, show that the proposed backbone provides strong supervised baselines under a compact parameter budget. JEPA pretraining further improves transfer, particularly in reduced-label settings and under both full fine-tuning and LoRA-based adaptation. Code: https://github.com/yakoubbazi/Hybrid_ECG_Jepa

0.26

LAF-ECG: Multi-Resolution Lead-Aware Fusion of Time-Series and Language Foundation Models for ECG Classification

cs.LG ·2026-11-22 ·Kiana Taktehrani, Maryam Hosseini, Amir Keynia, Aram Montazami, Arash Mohammadi
code/data similarity 0.72
Abstract

Automated electrocardiogram (ECG) interpretation has advanced substantially with deep learning, yet many methods remain task-specific and label-dependent. Large language models (LLMs) and time-series foundation models (TSFMs) offer complementary pretrained representations, but integrating them is challenging because of mismatched feature spaces and the lead- and scale-dependent structure of ECG signals. We propose LAF-ECG (Lead-Aware Foundation Fusion for ECG), a dual-foundation framework that extends MedTsLLM with a lead-aware interface to a frozen TSFM backbone while retaining its reprogramming pathway. The proposed framework captures multi-resolution temporal context, fuses temporal and language-aligned ECG representations through adaptive residual integration, and employs branch-specific supervision with cross-branch alignment. LAF-ECG achieves 71.10% accuracy and 62.43% macro-F1 on PTB-XL, and 89.73% accuracy and 65.94% macro-F1 on Chapman-Shaoxing, outperforming MedTsLLM on both datasets. These results highlight the value of preserving lead-specific temporal structure when combining temporal and language foundation representations for ECG classification. The code is publicly available at https://github.com/kkianamm/LAF-ECG.

0.30

TRACE: Expert-Aligned ECG Representation Learning with Rigorous Benchmarking and Real-World Validation in Acute Cardiac Care

cs.LG cs.AI ·2026-09-28 ·Lovely Yeswanth Panchumarthi, Andrew Lu, Saurabh Kataria, Delgersuren Bold, Minxiao Wang +9 more
benchmark similarity 0.71
Abstract · 42 pages, 4 figures and 1 table

TRACE (Text-Reinforced Analysis of Cardio ECGs) is a multimodal electrocardiogram (ECG) representation model that learns clinically grounded signal embeddings for downstream cardiac classification. It is designed to address the limitations of existing CLIP-style training, which often struggles with noisy clinical text and fails to leverage the complementary strengths of unimodal (from ECG) and cross-modal (between ECG and matched cardiologist reports) learning. To bridge this gap, we propose a hybrid architecture that jointly learns unimodal and cross-modal representations via uncertainty-weighted multi-task learning while utilizing an LLM-based pipeline to extract high-fidelity findings from cardiologist reports. We evaluate TRACE across a spectrum of clinical urgency, establishing robust performance on public benchmarks for arrhythmia classification and structural abnormalities relative to existing unimodal and multimodal ECG models. To demonstrate real-world utility, we further validate the model on acute coronary occlusion (ACO), where the prevailing ST-elevation criteria miss 25-34% of true occlusions. Utilizing a large private ACO dataset with expert-annotated ground truth, TRACE significantly outperforms real-world clinical practice, yielding a 19.0% increase in sensitivity or a 62.6% reduction in false positive rates at the clinical baseline. This extensive evaluation confirms that TRACE delivers both strong performance on benchmark tasks and tangible clinical impact in the most acute, high-risk cardiac scenarios.

0.11

TransECG-SSL: Hybrid Self-Supervised Representation Learning for ECG Arrhythmia Classification

cs.LG ·2026-10-26 ·Ahtisham Ayyub, Fasih Haider, Muhammad Rehan Usman, Saturnino Luz, Christos Politis +1 more
similarity 0.70
Abstract · Submitted to IEEE Journal of Biomedical and Health Informatics

Cross-dataset generalisation remains a major challenge for automated electrocardiogram (ECG) arrhythmia classification because of differences in patient populations, acquisition protocols, annotation practices, and class distributions. Learning representations that remain informative across independent datasets could reduce reliance on dataset-specific labelled data. We propose TransECG-SSL, a self-supervised framework for transferable heartbeat representation learning from unlabelled ECG data. A Transformer encoder is pretrained using a hybrid objective combining masked signal reconstruction and contrastive learning, then frozen and evaluated by linear probing under patient-disjoint evaluation. Experiments across three public ECG databases and seven source--target settings show that Hybrid SSL consistently outperforms randomly initialised Transformers and achieves higher balanced accuracy than architecture-matched source-supervised pretraining. Reconstruction-only SSL remains competitive with Hybrid SSL, whereas contrastive-only pretraining performs substantially worse, highlighting the importance of masked reconstruction for transferability. Cross-dataset transfer nevertheless reduces balanced accuracy relative to target-specific self-supervised pretraining, while minority arrhythmia classes remain challenging under severe class imbalance. These findings demonstrate the potential of label-efficient self-supervised learning for cross-dataset ECG representation transfer while highlighting persistent limitations from domain shift and class imbalance.

0.24

QECGBERT: A Scalable ECG Foundation Model Based on Self-Supervised Language Learning via VQ-VAE Waveform Tokenization

cs.LG cs.AI ·2026-10-25 ·Aruna Mohan, Burcu Ozek, Or Zilbershot, Fatemeh Afghah
similarity 0.70
Abstract · This work has been submitted to the IEEE for possible publication. Copyright may be transferred without notice, after which this version may…

AI foundation models play a pivotal role in advancing heart disease diagnosis from electrocardiogram (ECG) data, particularly for rare diseases where the lack of sufficient labeled data hinders supervised learning. However, most self-supervised learning methods treat ECGs as generic sequence or image data without exploiting underlying physiological structure. To address this limitation, we propose QECGBERT, a self-supervised ECG language model that explicitly encodes physiological semantics by tokenizing the P, QRS, T, and isoelectric background waveforms. Vector-quantized variational autoencoder (VQ-VAE) tokenization is applied to each 12-lead ECG, with tokens enriched by continuous waveform features to preserve morphology lost during quantization without increasing sequence length. This design enables compact BERT masked language modeling with short sequences, improving scalability and reducing computational cost relative to long-sequence approaches. QECGBERT applies BERT pre-training to the MIMIC-IV dataset containing over 800,000 unlabeled ECG recordings, and fine-tuning on labeled PTB-XL, CPSC2018, and Chapman--Shaoxing--Ningbo datasets for evaluation. The results demonstrate that QECGBERT achieves comparable or superior performance to published benchmarks, offering a scalable, physiologically aware approach to ECG foundation modeling for cardiac diagnosis.

0.22