CS Paper Radar

Where does pancreatic lesion segmentation fail on public CT? An attenuation-stratified analysis of a duct-guided pipeline on PanTS

Kang-Won Byun

eess.IV ·submitted 2026-11-23 00:42 UTC · v1
code/data

Abstract

Lesion segmentation is a building block of most CT pipelines for pancreatic cancer detection, yet lesion overlap scores stay low. Instead of proposing a new architecture, we report where an end-to-end pipeline fails on a large public dataset. On PanTS we built a three-stage pipeline: pancreas segmentation, maps of the main pancreatic duct (MPD) and common bile duct (CBD), and a lesion model that receives the CT with or without the predicted duct maps. Both lesion models were trained identically on 4007 scans and evaluated once on 737 held-out test scans (127 with a lesion) under a comparison rule fixed before the test run. Lesion Dice was 0.213 with duct maps and 0.209 with CT only (paired difference +0.004, 95% CI -0.011 to +0.019). The duct maps raised the share of lesions touched by a prediction (+0.079, 95% CI +0.024 to +0.134) but also enlarged predictions in lesion-free scans, and lesion-like regions were predicted in all lesion-free test scans. Out of fold, keeping only the predicted components that touched the lesion raised Dice only from 0.285 to 0.309; the loss came mainly from the extent of correctly located predictions. Clearly hypoattenuating lesions, which intensity alone separates from normal pancreas, had the lowest coverage (median 16.6%). From the predicted maps alone, the MPD diameter separated lesion from lesion-free test scans with AUC 0.794 (95% CI 0.747 to 0.839), while the CBD diameter was weak (AUC 0.603) and added nothing. Code for training, inference and evaluation is publicly available.

Comment
10 pages, 4 figures, 5 tables. Code: https://github.com/Kang812/pants-lesion-failure-analysis

Closest papers

Nearest neighbours by meaning across the whole index.

Uncertainty-aware Coarse-to-Fine Main Pancreatic Duct Segmentation for Width Measurement in 3D MRCP

cs.CV ·2026-10-29 ·Zipei Zhang, Jaakko Sahlsten, Mikko Saukkoriipi, Johanna Ronkainen, Mona Lehto +3 more
similarity 0.64
Abstract

Assessment of the main pancreatic duct (MPD) from volumetric magnetic resonance cholangiopancreatography (MRCP) scans is an essential task for ductal dilatation diagnosis and pancreatic cancer analysis. However, manual assessment is affected by reader variability in which automated analysis may assist. Nevertheless, fully automated and uncertainty-aware MPD analysis from volumetric MRCP remains underexplored area of research. In this study, we propose an automatic and uncertainty-aware deep learning-based pipeline for MPD segmentation and maximum-width analysis from MRCP scans. A coarse localisation model first identifies the ductal region-of-interest, followed by a fine model that segments the MPD within the region. The dataset consists of 256 MPD-segmented MRCP scans from 69 patients. A randomly selected holdout test subset of 14 patients with 55 MRCP volumes was used for evaluation. We employed a five-model cross-validation ensemble for improved performance and uncertainty estimation. The best MPD segmentation performance was 0.634 DSC, 0.744 precision, and 0.593 recall. The mean absolute error for maximum MPD width prediction was 0.355~mm and dilated MPD ($\geq 5$~mm) was detected with 75.0\% sensitivity and 74.4\% specificity. These novel results suggest that automated MPD segmentation can be used to aid MRCP-based duct measurements.

0.19

Segment Anything Pancreas: A Unified MRI Segmentation Model for Pancreatic Cancer Radiotherapy

cs.CV ·2026-10-29 ·Zach Eidex, Mojtaba Safari, Kundan Thind, Parag J. Parikh, Zhen Tian +1 more
similarity 0.60
Abstract

Background: Limited tumor annotations and incomplete labels across MRI datasets hinder unified segmentation of pancreatic tumors and organs at risk (OARs) for MRI-guided radiotherapy. Purpose: We propose Pancreas-MedNeXt, a unified model that segments the whole pancreas, its subregions, tumors, and surrounding OARs from one MRI volume. Methods: The model uses a shared MedNeXt encoder-decoder with supervised whole-pancreas and subregion pretraining, followed by multitask fine-tuning. Three output heads predict the pancreatic subregions, tumor, and OARs (stomach, duodenum, kidneys). An annotation-aware loss allows training on partially labeled data without treating unannotated structures as background. Pancreas and tumor were evaluated by three-fold cross-validation on 142 PANTHER patients (92 diagnostic, 50 MR-Linac), subregions and OARs on Cyst-X and AMOS test sets, and pancreas and OARs on 33 external T1-weighted TotalSegmentator scans. Comparisons with nnU-Net, MedNeXt, VISTA3D, and Swin UNETR used the Dice similarity coefficient (DSC) with paired bootstrap 95% CIs. Results: Pancreas-MedNeXt achieved the highest mean pancreas and tumor DSC on diagnostic and MR-Linac MRI. Tumor DSC was 58.41% and 42.55%, exceeding task-specific MedNeXt by 4.94 (95% CI: 0.28-9.45) and 5.89 (95% CI: 2.37-9.72) percentage points, respectively. Whole-pancreas DSC was 85.73% and 70.66%. Pretraining improved head, body, and tail DSC by 2.01, 3.00, and 3.78 percentage points over training from scratch. It also achieved the highest DSC for the pancreas, duodenum, and right kidney on AMOS, and for all five organs on external MRI, exceeding the next-best method by 4.92-8.85 percentage points.Conclusion: A single Pancreas-MedNeXt model segments tumors, pancreatic subregions, and OARs on diagnostic and MR-Linac MRI, which could streamline contouring for pancreatic cancer radiotherapy.

0.19

How Well Do Generalist CT Foundation Models Differentiate Liver Tumors?

cs.CV cs.AI ·2026-11-18 ·Yosuke Yamagishi, Tomohiro Kikuchi, Shouhei Hanaoka, Takeharu Yoshikawa, Osamu Abe
code/data similarity 0.58
Abstract · 12 pages, 3 figures. Code: https://github.com/yamagishi0824/liver-tumor-ddx-ct-fm

Generalist CT foundation models detect many findings with high performance, but their ability to differentiate detected lesions remains largely unevaluated. This retrospective study evaluated two generalist models, RADAR and Merlin, for differentiating liver tumors using a public single-institution multiphase CT dataset (517 cases: hepatocellular carcinoma, intrahepatic cholangiocarcinoma, breast and colorectal cancer liver metastases, and hemangioma). The models were evaluated in a zero-shot setting using their existing outputs and with linear probing, in which only a linear classifier was trained on frozen image features (stratified fivefold cross-validation repeated five times). In the zero-shot setting, RADAR achieved an accuracy of 54.4% (95% CI: 49.9, 58.8) and a $κ$ of 0.37 for four-class differentiation at the portal venous phase and predicted 31% (129 of 421) of malignant tumors as hemangioma. With linear probing of four-phase features, its accuracy improved to 79.9% (95% CI: 76.6, 83.4) with a $κ$ of 0.72, and 1% (five of 421) of malignant tumors were predicted as hemangioma; Merlin achieved an accuracy of 60.9% (95% CI: 56.9, 65.0). Generalist CT foundation models showed limited zero-shot ability to differentiate liver tumors, which improved substantially with linear probing alone.

0.50

A Multimodal Dataset for Survival Prediction in Resected Pancreatic Ductal Adenocarcinoma

cs.CV ·2026-09-24 ·Anh-Tien Nguyen, Mawuko Tettey, Jacqueline Michelle Metsch, Teresa Zimmer, Niklas Ullrich +12 more
similarity 0.56
Abstract

Survival research in pancreatic ductal adenocarcinoma (PDAC) is limited by the scarcity of datasets linking whole-slide histology with clinical, molecular, and long-term outcome data. We present a retrospective single-centre cohort of 302 patients who underwent PDAC resection at University Medical Center Gottingen. The dataset comprises 446 H&E whole-slide images, clinicopathological variables, targeted sequencing data for 154 patients, and overall-survival outcomes. During follow-up, 253 patients died, and the median follow-up was 76 months. To establish initial reference values, we evaluated fourteen survival-prediction configurations using identical five-repetition Monte Carlo cross-validation partitions. Ridge Cox regression using numeric clinicopathological variables achieved a mean concordance of $0.649 \pm 0.042$ and $0.652 \pm 0.046$ after adding KRAS and TP53 mutation status. The image-only attention model achieved $0.603 \pm 0.030$, while multimodal fusion achieved $0.619 \pm 0.025$, the highest concordance among the neural models. These results establish promising initial benchmarks for future research using this pancreas-specific multimodal dataset, paving the way for external validation.

0.25

Grounding Radiology Reports in 3D Chest CT: Results of the ReXGrounding Challenge

cs.CV cs.AI ·2026-11-18 ·Mohammed Baharoon, Mahmoud Hussain Alabbad, Sung Eun Kim, Xiaoman Zhang, Lucas Bijnens +57 more
benchmark similarity 0.56
Abstract · 25 pages, 13 figures, 4 tables

Segmenting each reported finding in a radiology scan would allow findings to be measured and tracked over time and let AI systems generate reports that are verifiable, but so far AI models have performed poorly at this task. To advance this task, we organized the ReXGrounding Challenge at MICCAI 2026, the first challenge dedicated to it. Given a non-contrast chest CT scan and the set of findings from its report, participants trained models to produce the corresponding set of 3D segmentations. The challenge used 2,992 training and 200 validation scans from the ReXGroundingCT dataset, and evaluated methods on a held-out test set of 300 scans with 582 findings, exhaustively annotated by board-certified radiologists. In total, 48 teams from 15 countries made 760 submissions, and the best method reached a Dice of 0.375 and a hit rate of 0.77, matching agreement between two independent radiologist groups (Dice 0.32, hit rate 0.76, on a 50-scan subset). On the 100 scans of the pre-challenge benchmark, the winner reached a Dice of 0.390, against 0.285 for VoxTell, the best model before the challenge, which five of the six best teams fine-tuned. Non-focal findings remained far harder to segment than focal ones, instance F1 stayed below inter-reader agreement (0.34 vs. 0.47), and models sometimes segmented the right abnormality in the wrong location. Top methods thus match radiologist agreement in Dice, but non-focal findings, findings with multiple instances, and adherence to the anatomical location described in the text remain open problems.

0.28

Report Supervision

cs.CV ·2026-08-27 ·Pedro R. A. S. Bassia, Wenxuan Li, Jakob Wasserthal, Jieneng Chen, Xinze Zhou +8 more
published similarity 0.56
Abstract · Published in Medical Image Analysis, 2026

Segmentation models can surpass radiologists, classification models, and vision-language models in tumor detection. Importantly, segmentation models outline tumors, allowing radiologists to better verify and trust the AI output. Their main limitation is the scarcity of tumor masks: creating one 3D tumor mask takes up to 30 minutes, so most public CT datasets contain only a few hundred masks, and even the largest private datasets contain only a couple of thousand. Tumor masks are not produced in clinical routine, but radiology reports are. Public datasets contain tens of thousands of CT-Report pairs, and hospitals contain hundreds of thousands. These reports describe tumors in detail, providing large-scale, informative training data. Here, we introduce Report Supervision (R-Super), a training framework that uses reports to directly supervise and improve tumor segmentation. R-Super introduces new loss functions that teach segmentation models to segment tumors that match report descriptions of tumor count, sizes, and locations. Reports are only used for training. We evaluated R-Super on kidney and pancreatic tumor segmentation, exploring diverse training data sizes, up to 41,418 CT-Report plus 3,488 pancreatic tumor CT-Mask pairs. On external validation, R-Super increased tumor detection F1-Score and segmentation DSC by up to +15% with respect to mask-only training. It also surpassed alternative methods such as CLIP and multi-task learning. Leveraging numerous readily available reports to supplement scarce masks, R-Super strongly improves AI performance when very few training masks are available (e.g., 50), and when many masks are available (e.g., 3,488), unlocking scale in tumor segmentation.

0.20

Improving Clinical Target Volume Segmentation Accuracy using Anatomical Priors and Active Learning for the AGITG TOPGEAR Clinical Trial

cs.CV physics.med-ph ·2026-09-02 ·Phillip Chlap, Mark Lee, Trevor Leong, Matthew Field, Jason Dowling +9 more
similarity 0.54
Abstract

Training deep learning-based medical image segmentation models is challenging with limited curated datasets. For AGITG TOPGEAR, a gastric cancer trial, the Clinical Target Volume (CTV) is complex and defined by multiple anatomical landmarks, making upfront training data preparation difficult for an automated contour QA segmentation model. We investigate anatomical priors, derived from surrounding organ segmentations, to provide spatial context and improve TOPGEAR CTV segmentation accuracy. We also evaluate active learning, iteratively expanding the training dataset by selecting cases expected to improve performance. One hundred TOPGEAR CT scans were retrospectively analyzed. An initial set of 10 expert-contoured cases was used to train an nnU-Net model. TotalSegmentator generated a voxel-wise anatomical prior map from surrounding structures as an additional input channel. Active learning was simulated over four iterations, selecting cases by model uncertainty and segmentation performance. All models used five-fold cross-validation for an ensemble uncertainty measure. Evaluation used a hold-out testing set of 50 cases. The anatomical prior improved CTV segmentation accuracy, increasing mean Dice Similarity Coefficient (DSC) from 0.84 to 0.86. Active learning similarly improved performance to 0.86, with greatest benefit in the final round. Combining the anatomical prior with active learning achieved the highest accuracy, with a DSC of 0.87. Model uncertainty correlated with DSC, supporting its use in identifying suboptimal predictions and guiding active learning. Anatomical priors and active learning each improved CTV segmentation accuracy and generalizability, with their combination achieving the best performance, supporting integration into segmentation model development for automated contour QA in radiotherapy clinical trials.

0.16

Evaluating the Effects of Inter-Observer and Model Variability on Radiological Peritoneal Cancer Index Assessment

eess.IV cs.CV ·2026-08-28 ·Savvas Saragiotis, Pieter C. Gort, Lotte J. S. Fleurkens-Ewals, Anna F. van Herwijnen, Marion Tops-Welten +3 more
published similarity 0.54
Abstract · Accepted as a CaPTion workshop paper at MICCAI 2026

Deep learning segmentation models are often evaluated using geometric metrics such as Dice, HD95, and ASD, yet it remains unclear to what extent improvements in these metrics translate into clinically meaningful changes in downstream decision-making. The metric-to-decision gap is examined using radiological Peritoneal Cancer Index (rPCI) region segmentation on contrast-enhanced CT, where a consensus definition provides anatomically grounded 3D regions and the clinically used PCI 20 threshold enables decision-level evaluation. Inter-observer variability is quantified across four experts on ten abdominal CT scans, and a published nnU-Net based rPCI segmentation model is benchmarked against this human reference using Dice, HD95, and ASD across all 13 regions. To relate geometric differences to clinical impact, a probabilistic peritoneal metastasis simulation is implemented on majority-vote rPCI maps, propagating region-boundary variability into variability of derived (r)PCI scores and classification at the PCI 20 cutoff. Observers showed high agreement (mean Dice $0.87$), while the model matched human performance in most regions but deviated more in regions 4, 8, and the small-bowel regions (9-12). Across simulations, score differences were typically small (mean $Δ$rPCI $\approx 0.3$-$0.6$) for both observers and the model, and decision flips occurred predominantly when the reference score was near 20. These results suggest that rPCI-derived scoring is generally robust to typical segmentation variability, while highlighting borderline cases as the main setting where expert review remains essential.

0.40