CS Paper Radar

FGSCalib: Targetless Camera-LiDAR Extrinsic Calibration from Foreground Segmentation

Marcell Kégl, Csaba Benedek

cs.CV ·submitted 2026-11-23 16:20 UTC · v1
code/data

Abstract

Camera-LiDAR pairs installed as fixed infrastructure need periodic recalibration, but a calibration target takes the installation out of service. We present FGSCalib, a targetless method that calibrates a stationary camera-LiDAR pair from the objects moving in its view. We only assume that arbitrary moving objects are present in the scene: each sensor separates the moving foreground from the static background, without relying on object classes. With the correct extrinsic, the LiDAR foreground points project onto the camera foreground. FGSCalib turns the camera mask into a boundary-proximity field and finds the extrinsic by two-stage simulated annealing over selected frame pairs. It needs no measured initial extrinsic (random starts give similar results) and works with both rotating and non-repetitive LiDARs. We evaluate it on 21 simulated scenarios with exact ground truth and on 72 real ones (nine camera-LiDAR pairs in eight scenes), with a reference averaged from 43 manual calibrations. In simulation the median error is 5.3 cm and 0.19°. On real data we use a tolerance of 18 cm and 1.8°, met by 93% of single manual calibrations. Keeping the lowest-cost of five runs, FGSCalib meets it in 51 of the 72 scenarios: in 20 of 24 with the Livox, where the strongest of five baselines reaches 11, and in 31 of 48 with the two rotating LiDARs, where only one baseline estimate does. Its median error is 9.5 cm and 0.9°, against 7.3 cm and 0.7° for a single manual calibration. The code and the dataset are available online.

Comment
12 pages, 5 figures, and 4 pages of supplementary material. Code: https://github.com/zsungi/fgscalib

Closest papers

Nearest neighbours by meaning across the whole index.

VeriCalib: Verifiable Target-Based LiDAR-Camera Calibration

cs.RO ·2026-10-20 ·Xiangcheng Hu, Xieyuanli Chen, Feiyi Chen, Shengli Ren, Shiyang Chen +6 more
similarity 0.70
Abstract · 35 pages, 20 figures, 13 tables

Target-based extrinsic calibration estimates the rigid transform between sensors from a few observations of a known target, and its result is commonly assessed by the root-mean-square error of the fitted residuals. However, this scalar error is computed on the same observations and therefore cannot indicate whether to accept the result, re-extract, recollect or add observations. This paper presents VeriCalib, which formulates extrinsic calibration as a verifiable estimation problem and reports a calibration state. The key insight is a two-level extrinsic compensation mechanism, in which the extrinsic compensates the rigid part of each observation error at the residual level, and rotation and translation compensate each other at the parameter level. Consequently, the fitted residual can reveal neither an inconsistency between the observations and the model nor whether the estimated extrinsic is reliable in every direction. Accordingly, we assess the calibration through a structured covariance that jointly propagates the uncertainty of the camera and LiDAR board features with a known-geometry prior, and estimate its scale as a variance component from the residuals. On this covariance, we decouple rotation and translation to resolve the precision along each direction and guide data collection toward the weakest one. Since this precision presumes consistent observations, we further develop within-view and cross-view checks that examine the internal residual and the rigid discrepancy between observations, respectively, with thresholds that hold their significance level under an unknown noise level. We also extend the minimal detectable bias to the extrinsic to bound the smallest detectable fault along each direction. These criteria form a calibration state that indicates whether to accept the result or how to collect the data...

0.22

MiCaDe: Online LiDAR-Camera Miscalibration Change Detection for Autonomous Driving

cs.CV cs.LG ·2026-11-03 ·Carlo Sgaravatti, Riccardo Pieroni, Matteo Corno, Sergio M. Savaresi, Luca Magri +1 more
code/datahot direction similarity 0.69
Abstract

Reliable multi-sensor perception in autonomous vehicles requires accurate calibration between cameras and LiDAR. However, calibration drift is often unavoidable in long-term deployments: vibrations, thermal effects, and minor mechanical shocks may alter the relative pose between sensors, leading to systematic errors in downstream fusion tasks. We propose MiCaDe (Miscalibration Change Detection), an online solution detecting when the extrinsic LiDAR-camera calibration parameters are no longer accurate by means of sequential change detection. MiCaDe requires no calibration targets, or modification of the perception stack, providing low false-alarm rates with negligible computational overhead. Our key insight is that 3D and 2D bounding boxes produced by standard object detectors should remain geometrically consistent under correct calibration. By matching cross-modal detections, we derive geometric consistency metrics that serve as sensitive indicators of extrinsic drift. These metrics are aggregated into fixed-size batches and scored against a reference distribution, producing a likelihood stream that is monitored by a Change Point Model (CPM). Crucially, the CPM accumulates statistical evidence over time, enabling detection of subtle drifts that would otherwise go unnoticed. Experiments on multiple long-sequence datasets and on a real-world dataset with physically induced miscalibration confirm reliable detection under diverse conditions. Code available at: https://github.com/CarloSgaravatti/MiCaDe.

0.32

Extending Ground-Constraint LiDAR-IMU Calibration to Tilted Surfaces in a Continuous-Time Framework

cs.RO ·2026-08-25 ·Vassili Korotkine, Pierre Chamoun, Mohammed Ayman Shalaby, James Richard Forbes
code/data similarity 0.66
Abstract · 8 pages, 13 figures. Submitted to Robotics & Automation Letters

This paper presents a novel method that extends targetless LiDAR-IMU calibration for ground vehicles to non- flat environments. Calibration typically necessitates full exci- tation of the sensor rig, a requirement that is not fulfilled by ground vehicles in normal operation. To address the degenerate planar motion, state-of-the-art methods propose residuals that assume the colinearity of the gravity and physical surface normal vectors, restricting usage to cases where the ground is assumed flat. This paper proposes ground-plane residuals that do not require this assumption, and are applicable for planar motion on a tilted surface. Results are demonstrated on a dataset collected from a Husky ground vehicle, on the M2DGR dataset, as well as on an offroad vehicle dataset. Repeatability is shown to be improved both in tilted and flat-ground scenarios, with strong improvement demonstrated for the tilted case. The implementation and experiments are open-sourced at https://github.com/vkorotkine/licalib_tilted_ground.

0.43

CalibSwitch: Observation-Driven Camera-LiDAR Extrinsic Recovery and Selective Maintenance for Multimodal Perception

cs.RO cs.CV ·2026-10-30 ·Haifa Zhang, Yijing Wang, Zhiqiang Zuo
similarity 0.66
Abstract

Camera--LiDAR perception on mobile robots and intelligent vehicles depends on reliable sensor geometry throughout deployment. Installation variations create uncertainty in the initial extrinsics, while changing observation quality makes frame-wise estimates fluctuate during operation. This paper presents CalibSwitch, an observation-driven framework that separates absolute extrinsic recovery from selective state maintenance. A cross-modal absolute extrinsic generator (CAEG) combines projection-free bidirectional feature interaction with geometry-regularized learning to recover complete SE(3) candidates from image--point observations and coarse view context, without a supplied numerical initial transform. A selective recurrent calibration policy (SRCP) combines observation quality and temporal history to determine when a candidate should replace the working geometry consumed by a frozen multimodal detector. On nuScenes, CAEG achieves mean translation and rotation errors of 0.248 m and 5.884$^\circ$. Under sustained geometric transitions, SRCP reaches a mean composite error of 1.46 with 9.70\% candidate commitments, outperforming quality-based and temporal-consistency gating at comparable commitment rates. Relative to unconditional per-frame updating, it improves frozen-detector mAP and NDS by 1.43 and 0.92 points. Paired geometry--observation uncertainty tests, two real-vehicle platforms, and 13.5-FPS single-camera Jetson execution demonstrate the system value of selective geometric-state maintenance for continuous perception.

0.16

Can a Display Be Used for Rapid LiDAR-Camera Extrinsic Calibration?

cs.CV ·2026-10-20 ·Zuhao Zou, Xiangcheng Hu, Jianhao Jiao, Jin Wu
benchmarkcode/data similarity 0.66
Abstract

ScreenCalib enables light detection and ranging (LiDAR)--camera extrinsic calibration using an ordinary programmable display, providing known visual markers and controlled geometry while reducing dedicated target preparation. The camera observes displayed AprilTags, whereas the LiDAR measures the physical screen surface and boundary, requiring indirect cross-modal association. Display geometry introduces association ambiguities, while indoor clutter complicates extraction. ScreenCalib addresses these challenges through tag-guided display extraction, geometric hypothesis generation and refinement, and surrounding scene edges for ambiguity resolution. The single-pose mode requires only one static placement. The joint multi-pose mode combines independent static observations through cross-pose consensus and jointly refines the shared extrinsics and tag scale, reducing sensitivity to tag-size measurement errors without requiring continuous motion or inter-pose trajectory estimation. Experiments in simulation and on three different sensor platforms cover mechanical and nonrepetitive LiDARs in clean and cluttered environments. Benchmark results show that ScreenCalib outperforms competitive calibration-board-based methods in translation accuracy. Joint multi-pose refinement further reduces mean rotation and translation errors across the three platforms and improves rendered-map alignment. Evaluation across readily available displays, including cell phones, tablets, laptops, computer monitors, and televisions, further examines ScreenCalib's versatility as a practical alternative to dedicated calibration targets. The source code is available at https://github.com/ZuhaoZou2026/ScreenCalib.

0.23

Online Target-less Radar-LiDAR-Camera Extrinsic Calibration via Joint Optimization

cs.RO ·2026-10-03 ·Gunhee Shin, Yunsoo Kim, Chanhyuk Lee, Wanhee Kim, Minwoo Lee +5 more
published similarity 0.65
Abstract · 6 pages, 2 figures, 3 tables. Accepted to the International Conference on Control, Automation and Systems (ICCAS 2026)

Fusing radar, LiDAR, and camera enables robust perception in diverse and adverse conditions, but the fusion performance critically depends on accurate extrinsic calibration among the three sensors. In this paper, we address the problem of online target-less extrinsic calibration for the radar-LiDAR-camera system. Existing target-less methods are mostly designed for a single sensor pair, and composing the pairwise results does not guarantee consistency across the three sensors. Moreover, the sparse and noisy radar measurements make the radar-involving pairs unreliable. To tackle these challenges, we propose a joint calibration framework that constructs residuals for each sensor pair and optimizes the extrinsics of all pairs together to minimize the overall residual. Furthermore, we introduce an adaptive radar noise filter that rejects spurious radar returns using a range-dependent margin, and a correspondence accumulation strategy that aggregates sparse radar correspondences over frames. We validate our method on an in-house radar-LiDAR-camera dataset covering diverse urban environments, where it reduces calibration errors across all sensor pairs over a state-of-the-art camera-LiDAR baseline.

0.23

Agreement Is Not Accuracy: LiDAR Elevation Errors Hidden in LiDAR-Camera Extrinsics

cs.CV ·2026-11-18 ·Yeon Kun Lee, Dongseok Yang, Deok-Kyeong Jang, Choongho Chung, Junyoung Lee +1 more
similarity 0.64
Abstract · 14 pages, 6 figures, including supplementary material

LiDAR and cameras provide complementary measurements for 3D vision, yet agreement between their observations does not establish the accuracy of either sensor's internal geometry. We show that systematic LiDAR elevation biases can be absorbed into the estimated extrinsics. Using synchronized LiDAR intensities and camera-estimated checkerboard poses, we jointly estimate a sensor-specific elevation correction shared across recordings and extrinsics for each recording. Ray-plane intersections locate the checker pattern without using reported ranges, preventing range errors from directly moving the lookup. Under matched intensity and correction models, this lookup gives smaller camera-consistency residuals than measured-point lookup. Across six identically designed rigs using the same sensor models, recording-excluded corrections reduce the mean translation-reference distance from 7.57 to 3.04 mm. On separate structures, they reduce inter-plane angle errors against references from independent dense camera scans and improve image-edge alignment. Rolling the rigs shifts the plane pairs exhibiting the largest angular improvements, as predicted for an elevation-only correction. Within the ray-plane model, calibration-target projections and loop-consistency residuals change little despite these geometric improvements. These findings show why agreement after extrinsic calibration need not establish correct internal LiDAR geometry. Synchronized observations of a familiar checkerboard provide a practical route to estimating and testing elevation corrections without a dedicated large calibration field. We plan to release code and data for reproducing the main results.

0.29

GeLiFiSH: Recursive LiDAR Keypoint Estimation with Ground and Moving Object Segmentation

cs.CV cs.RO ·2026-11-23 ·Nikolaos Stathoulopoulos, George Nikolakopoulos
similarity 0.64
Abstract · 8 pages, 3 figures, 3 tables, submitted

LiDAR registration and loop closure often rely on sparse keypoints, which must remain repeatable across sessions, viewpoints, and sensors. To handle differing scan patterns, detectors typically operate on accumulated submaps, which introduces latency and processes each submap independently, so repeated observations are never fused. Height-based detectors also reference structure to an estimated ground, so its inconsistency across sessions propagates into the keypoints. Moreover, dynamic objects leave ghost trails that can be mistaken for static structure. We present GeLiFiSH (Geometric LiDAR Filtering with Sequential Hypothesis testing), a learning-free filter that recursively estimates persistent keypoints at scan rate. A height-structure detector runs on a rolling voxel map, and detections initialize tracks with a position, covariance, and existence probability, accepted or rejected by a sequential probability ratio test. Ground segmentation provides a sensor-agnostic height reference, and moving object segmentation removes dynamic points before map insertion. On SemanticKITTI, HeLiMOS, and HeLiPR, spanning five LiDARs and multiple sessions, GeLiFiSH attains the highest average keypoint repeatability among the compared detectors and the second-highest cross-session registration recall from keypoints alone, behind ISS which extracts four times as many keypoints. With one parameter set and no sensor-height prior, both ground and moving object segmentation modules outperform their baselines on average.

0.23