CS Paper Radar

CrownFusion: 3D Dental Crown Generation Using Geometry Images and Latent Diffusion

Johan Ziruo Ye, Xingguang Yan, Søren Hauberg, Angel X. Chang, Hao Zhang, Peter Lempel Søndergaard

cs.CV cs.GR ·submitted 2026-11-23 18:00 UTC · v1
top venuecode/data

Abstract

We introduce CrownFusion, a latent diffusion model to generate 3D dental crown designs from geometry images, a 2D-grid encoding of surface coordinates. Departing from traditional approaches that use point clouds, our "CrownImage" representation not only unlocks the full power of image-based generative architectures, but also preserves fine geometric detail by operating at far higher spatial resolutions than point clouds to alleviate smoothing artifacts in the 3D generation. Conditioned on jointly learned embeddings of the surrounding dentition, our probabilistic diffusion model produces anatomically plausible crowns with morphological variations tailored to individual patient cases. To accommodate multiple valid designs, we propose an occlusal fit metric based on proximity to the antagonist teeth. We evaluate our method through quantitative experiments and qualitative studies involving expert testimonials. We also release the FDI 16 Crown Dataset, comprising 11,513 annotated intra-oral scans, to support future research in dental CAD.

Comment
Accepted at MICCAI 2026. 11 pages, 6 figures. Equal contribution: J. Z. Ye and X. Yan. Project page: https://crownfusion.github.io/
Journal ref
Medical Image Computing and Computer Assisted Intervention - MICCAI 2026. Lecture Notes in Computer Science, vol 16889, pp. 464-474. Springer (2026)
DOI
10.1007/978-3-032-38186-6_44

Closest papers

Nearest neighbours by meaning across the whole index.

CarDiff: Anatomically Aware Dental Caries Synthesis using Diffusion

cs.CV cs.LG ·2026-10-13 ·Sanyam Jain, Bruna Neves de Freitas, Alexandros Iosifidis, Ruben Pauwels
code/data similarity 0.67
Abstract

Synthetic medical image generation can help address limited annotated data in dental imaging, particularly for under-represented caries classes. In this work, we present CarDiff, a semi-supervised framework for dental caries synthesis in panoramic radiographs. The method combines paired mask-image learning with self-supervised generation from augmented masks, while incorporating anatomy-aware conditioning between lesion regions and surrounding structures. Semantic consistency is enforced through segmentation-guided supervision and adversarial anatomical alignment. Experiments on the MLUA-DC1000 dataset show that CarDiff achieves improved synthesis quality compared with existing semantic synthesis baselines, obtaining the best Fréchet Inception Distance (FID) (90.76) and Learned Perceptual Image Patch Similarity (LPIPS) (0.48) scores among evaluated methods. We further assess the generated radiographs for downstream segmentation augmentation across seven architectures. Using a 5x augmented training set improves average Dice score by up to 6.5%, with larger gains observed for medium and combined lesion classes. These results suggest that anatomically consistent diffusion synthesis may be useful for dental radiograph augmentation under limited supervision. The code is available at https://github.com/s4nyam/CarDiff.

0.32

Flow Matching Meets 3D Curvilinear Structure Segmentation in Medical Imaging

cs.CV cs.LGq-bio.QM ·2026-08-20 ·Sidi Mohamed Sid'El Moctar, Nicolas Vitry, Hélène Bouvrais
published similarity 0.62
Abstract · International Workshop on Machine Learning in Medical Imaging (MLMI 2026) @ MICCAI

Segmentation of curvilinear anatomical structures in 3D medical images remains challenging due to complex topology, severe class imbalance, weak contrast, and large variations in structure morphology. While deep learning approaches for 3D curvilinear segmentation have been proposed, they are often tailored to specific anatomies or modalities, limiting generalization across clinical settings and leaving room for improvement. Recent generative models have shown the benefits of iterative prediction for structured segmentation tasks, yet diffusion-based methods suffer from computationally expensive sampling, hindering their use on high-resolution 3D volumes. We present 3D-CurvSegFlow, a flow matching-based model for 3D curvilinear structure segmentation. The model learns a continuous transformation from a simple source distribution to the target vascular representation, enabling progressive refinement of complex curvilinear geometries with efficient inference. We evaluate our method on Three public challenging datasets covering distinct anatomies and modalities: portal vein, cerebral vessel, and coronary arteries. Using a common architecture and training strategy across all tasks, our method outperforms general-purpose and vessel-specific approaches, with strong preservation of thin branches and vascular continuity. This work not only advances the state-of-the-art in 3D curvilinear segmentation but also opens new avenues for efficient, generalizable, and clinically applicable methods in medical image analysis.

0.23

Teeth2Point: A Two-Stage Dental CBCT ROI-to-Point Segmentation Framework

cs.CV ·2026-08-19 ·Qi Ma, Shipra Jain, Niko Benjamin Huber, Ender Konukoglu
similarity 0.62
Abstract

Modern deep learning architectures have demonstrated strong performance in dental CBCT segmentation. One remaining crucial challenge is accurate tooth labeling in cases with missing or malpositioned teeth, which are highly relevant for dental practice. Transformer-based architectures should in theory be able to resolve such ambiguities using global anatomical context. However, due to the high resolution of CBCT volumes and the wide spatial distribution of teeth within volumes, dense patch-based volumetric processing faces an inherent trade-off. Computational costs limit the number of patches that can be used in self-attention and thus, one can either increase the extent of the context captured in self-attention or capture fine-grained structural details by using small patches, but not both. In this work, we present Teeth2Point, an efficient point-based transformer framework for dental CBCT semantic segmentation that can avoid this trade-off. Teeth2Point first localizes volumetric regions of interest (ROIs) surrounding teeth using a convolutional model, then converts ROIs into point tokens using adaptive sampling. A transformer model predicts accurate segmentations using the point tokens, which allow capturing global context while retaining high resolution. The transformer is first pretrained using self-supervised learning (SSL), in the style of DINO but using domain-specific augmentation strategies, followed by supervised finetuning. The SSL pretraining, which includes random token masking, provides robustness to complex anatomical variations. Compared with the strongest two-stage baseline, Teeth2Point improves abnormal-case performance by 1.44 DSC points on average across four datasets; relative to the first-stage nnU-Net, the gain is 1.9 points.

0.32

Topology of a Smile: Persistent Homology in Dental Imaging

cs.CV math.AT ·2026-08-14 ·Leon Dahlmeier, Sara Kališnik, Albert Mehl, Bastian Rieck
similarity 0.61
Abstract

CBCT (Cone Beam Computed Tomography) scans provide detailed three-dimensional images, widely used in dentistry for diagnostic and treatment planning tasks. While invaluable, analyzing and documenting these scans is labor-intensive, prompting efforts to automate key steps like the classification and segmentation of anatomical structures to identify tooth types and associated pathologies. In this article, we propose an approach to automation that leverages persistent homology, a framework from topological data analysis that studies the shape of data by identifying features like connected components, holes, and voids across multiple scales. Persistent homology, together with a support vector machine, allows us to classify teeth in a CBCT scan and to perform diagnostics. Our method advances the state of the art, reaching average accuracy scores of 97.67% for tooth-labeling and 96.77% for diagnostic tasks, outperforming a CNN trained on the same data with accuracy of 70.27% and 86.67%, respectively.

0.04

Occlusal Geometry in Closed Form for Orthodontic Report Generation

cs.CV cs.CL ·2026-09-02 ·Ajo Babu George, Govind Arun, Sidharth N Krishna, Uma Ranjan
code/dataunusual similarity 0.60
Abstract · 10 pages, 4 figures. Third-place system in the ODIN 2026 Bite2Text test phase. Code and data processing resources: https://github.com/GIND12…

Orthodontic report generation from intraoral data is normally cast as multimodal captioning, yet the released Bite2Text scan pairs are supplied already registered in occlusion, which makes several core occlusal quantities directly measurable rather than inferable. The system reported here exploits that property: an anatomical frame is recovered per case from arch taper and arch closure instead of the stated RAS convention, which does not hold across the release, and each arch is reduced to an occlusal ridge profile in arch-angle coordinates yielding overbite, overjet, midline deviation, transverse overlap, crossbite extent, cusp interdigitation lag, and the occlusal curves in closed form. Gradient boosting maps 31 such measurements onto 13 template fields, a field being predicted only where patient-level cross-validation beats its own majority baseline, and a deterministic renderer emits the corpus six-part narrative; a ConvNeXt-Tiny classifier over the five standardised photographic views is fused per field, raising mean field accuracy from 0.601 to 0.683. Reimplementation of the challenge evaluator shows that its BLEU-4 and METEOR are local variants whose F-mean weights recall nine to one, that two clinicians agree on 47 percent of findings for the same patient, and that a constant report consequently outscores a genuine second clinician report by 0.165 captioning. Held-out scores reach BLEU-4 0.458 and METEOR 0.677 against intraoral scan references and 0.278 and 0.507 against photograph references, and the submitted system placed third in the ODIN 2026 Bite2Text test phase at 0.2680 and 0.4629, within 0.022 BLEU-4 of first, running on CPU in under ten seconds per case. The dataset and code are available at https://github.com/GIND123/ODIN_toothfairy4

0.41

Sparse-View 3D Coronary Reconstruction from Vessel Segmentations Using a Diffusion Prior

eess.IV cs.CV ·2026-11-03 ·Tianyuan Wang, Kenan Niu, Stefano Stramigioli
similarity 0.59
Abstract · 10 pages, 5 figures, 2 tables

Reconstructing three-dimensional (3D) coronary anatomy from sparse angiographic views could support percutaneous coronary intervention, but limited angular coverage and imperfect vessel segmentations introduce substantial geometric ambiguity. We propose a vessel-specific reconstruction framework combining a learned 3D diffusion prior, visual-hull initialization, and projection-based data consistency. The unconditional diffusion model is trained on coronary vessel masks without paired 2D--3D data and reused across different view counts without retraining. During inference, a scaled visual hull initializes reconstruction, while projection-based updates constrain diffusion refinement using patient-specific vessel observations. We evaluated the framework on simulated angiograms derived from ImageCAS computed tomography angiography volumes using two, four, and eight views at two contrast levels. Across 50 evaluation coronary-tree cases, the proposed method achieved higher mean Dice and clDice than visual hull, deep image prior (DIP), and hash-grid implicit neural representation (INR) at all view counts under reduced contrast. With eight views, improvements over DIP, the best-performing baseline at lower contrast, were approximately 0.13 in Dice and 0.22 in clDice. At higher contrast, performance remained competitive with hash-grid INR, the best-performing eight-view baseline. The preferred diffusion starting timestep depended on observation quality and view count, with excessive refinement reducing accuracy at higher contrast. Projection guidance improved both metrics across all conditions. Averaging stochastic reconstructions further improved accuracy, while sample disagreement localized errors with average-precision gains of 0.14--0.21 over error prevalence. These findings support diffusion-prior reconstruction from sparse vessel observations, although clinical validation remains necessary.

0.11

B-Spline Embedded Structure Learning for 3D Tooth Segmentation

cs.CV ·2026-08-18 ·Xianghan Wei, Jianwen Lou, Zhiguo Lu, Hairong Jin, Haihua Zhu
benchmark similarity 0.59
Abstract

Accurate 3D tooth segmentation forms the cornerstone of digital dentistry, yet it remains a formidable challenge due to the inherent intricacy of real-world dentitions, such as crowding, misaligned teeth and high morphological similarity between adjacent teeth. To resolve this, we present B-Spline Embedded Structure Learning, a novel framework that distills the inherent sequential arrangement of teeth into a continuous structural constraint to regularize representation space. Our approach parameterizes the global dental topology by fitting a parametric B-spline trajectory to tooth centers, assigning each point a continuous structural embedding that forces the shared backbone to capture global arch organization. To fully exploit these embedded priors, we introduce a Structure-Aware Dynamic Classifier (SADC) to substitute rigid static templates with adaptive, case-calibrated decision boundaries. SADC regularizes dynamic prototype pooling via a localized Gaussian proximity gate and contextually co-evolves them through an attention block modeling spatial relations and bilateral symmetries across teeth. Extensive evaluations on the 3DTeethSeg22 benchmark demonstrate that our method establishes a new state-of-the-art accuracy with exceptional structural robustness and efficiency in computational overhead, markedly enhancing the model's capacity to handle complex dental configurations.

0.40

Morphological Decoupling-Based Skeletal Classification for Clinical Assessment of Malocclusion

eess.IV cs.CV ·2026-09-09 ·Zhichun Jin, Zhicheng He, Hao Xu, Dongyang Li, Lin Wang +2 more
published similarity 0.59
Abstract · Accepted by Biocybernetics and Biomedical Engineering

Malocclusion skeletal grading is a fundamental task in orthodontics, critical for diagnosis and treatment planning. Traditionally, cone-beam computed tomography (CBCT) is used for visual measurement, and the reconstructed lateral cephalograms are handed over to expert dentists for diagnosis. However, manual review is time-consuming, labor-intensive, and subject to inter-operator variability. Therefore, an automatic CBCT-based system is needed for reliable malocclusion skeletal grading. In this case, we develop TeethGNN, a novel graph-based framework designed to combine CBCT image features with morphological information for accurate and efficient malocclusion grading. TeethGNN utilizes a decoupled learnable decoder to directly predict key morphological indicators from CBCT images, eliminating the need for manual measurements. These morphological features are then fused with image features using a graph neural network (GNN), which effectively models the relationships between the modalities. To further enhance robustness and calibration, we introduce a collaborative calibration strategy. This strategy combines multi-scale graph adversarial perturbation for explicit calibration and nonlinear topological graph calibration for implicit confidence adjustment. Extensive experiments and ablation studies on our collected clinical dataset demonstrate that our malocclusion measurement system achieves 77.08\% in accuracy and 89.61\% in AUC, outperforming the compared state-of-the-art methods. These results validate the effectiveness of graph-based multimodal fusion and collaborative calibration in improving malocclusion grading performance. Our system shows strong potential for advancing computer-aided orthodontic diagnosis, providing an accurate and reliable solution for vision-based clinical measurement and diagnosis.

0.36